Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Artifacts in time-resolved Kelvin probe force microscopy

Kelvin probe force microscopy (KPFM) has been used for the characterization of metals, insulators, and semiconducting materials on the nanometer scale. Especially in semiconductors, the charge dynamics are of high interest. Recently, several techniques for time-resolved measurements with time resolution down to picoseconds have been developed, many times using a modulated excitation signal, e.g. light modulation or bias modulation that induces changes in the charge carrier distribution. For fast modulation frequencies, the KPFM controller measures an average surface potential, which contains information about the involved charge carrier dynamics. Here, we show that such measurements are prone to artifacts due to frequency mixing, by performing numerical dynamics simulations of the cantilever oscillation in KPFM subjected to a bias-modulated signal. For square bias pulses, the resulting time-dependent electrostatic forces are very complex and result in intricate mixing of frequencies that may, in some cases, have a component at the detection frequency, leading to falsified KPFM measurements. Additionally, we performed fast Fourier transform (FFT) analyses that match the results of the numerical dynamics simulations. Small differences are observed that can be attributed to transients and higher-order Fourier components, as a consequence of the intricate nature of the cantilever driving forces. These results are corroborated by experimental measurements on a model system. In the experimental case, additional artifacts are observed due to constructive or destructive interference of the bias modulation with the cantilever oscillation. Also, in the case of light modulation, we demonstrate artifacts due to unwanted illumination of the photodetector of the beam deflection detection system. Lastly, guidelines for avoiding such artifacts are given.

36 MATERIALS SCIENCE↗

Evidence from the ancient world on long-term preservation of artifacts - 15442

As a cradle and crossroads of civilizations, a bridge between the ancient political and cultural centers of Mesopotamia and Egypt, and home to three major religions, the land of Israel is rich with archaeological artifacts. Dating back thousands of years, many such artifacts have been preserved in remarkable condition - enduring the tumultuous test of time, environment, and regional turmoil. The study of these artifacts can undoubtedly serve as an analogue for a modern, permanent marker system for a geologic nuclear waste repository, shedding light on how a marker can endure man-made and natural disasters over thousands of years. Indeed, these artifacts, and our ability to decipher their various messages, not only provide us with a rich knowledge of our ancestors from the past, but they likewise provide insight into the techniques and conditions needed for long-term preservation and endurance of man-made items over time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model-based iterative reconstruction with adaptive regularization for artifact reduction in electron tomography

Obtaining high-quality 3D reconstructions from electron tomography of crystalline particles embedded in lighter support elements is crucial for various material systems such as catalysts for fuel cell applications. However, significant challenges arise due to the limited tilt range, sparse and low signal-to-noise ratio of the measurements. In addition, small metal particles can cause strong streaking and shading artifacts in the 3D reconstructions when using conventional reconstruction algorithms due to the presence of Bragg diffraction and the large scattering cross-section difference between the materials of the particles and the background support regions. These artifacts lead to errors in the downstream characterization affecting extraction of critical features such as the size of the metal particles, their distribution and the volume of the lighter support regions. In this paper, we present a two-stage algorithm based on metal artifact reduction, utilizing model-based iterative reconstruction methods with adaptive adjustment of regularization parameters. Our approach yields high-quality 3D reconstructions compared to traditional algorithms, accurately capturing both the metal particles as well as the background support. We demonstrate the effectiveness of our algorithm through simulated and experimental bright-field electron tomography data, showing significant improvements in reconstruction quality compared to traditional methods.

97 MATHEMATICS AND COMPUTING↗

In situ compression artifact removal in scientific data using deep transfer learning and experience replay

The massive amount of data produced during simulation on high-performance computers has grown exponentially over the past decade, exacerbating the need for streaming compression and decompression methods for efficient storage and transfer of this data---key to realizing the full potential of large-scale computational science. Lossy compression approaches such as JPEG when applied to scientific simulation data realized as a stream of images can achieve good compression rates but at the cost of introducing compression artifacts and loss of information. This paper develops a unified framework for in situ compression artifact removal in which the fully convolutional neural network architectures are combined with scalable training, transfer learning, and experience replay to achieve superior accuracy and efficiency while significantly decreasing the storage footprint as compared with the traditional optimization-based approaches. We demonstrate the proposed approach and compare it with compressed sensing postprocessing and other baseline deep learning models using climate simulations and nuclear reactor simulations, both of which are driven by hyperbolic partial differential equations. Our approach when applied to remove the compression artifacts on the JPEG-compressed nuclear reactor simulation data (using a transfer-trained model that was pretrained on the climate simulation data and updated incrementally as the nuclear reactor simulation progressed), achieved a significant improvement---mean peak signal-to-noise ratio of 42.438 as compared with 27.725 obtained with the compressed sensing approach.

97 MATHEMATICS AND COMPUTING↗

Ring artifact reduction via multiscale nonlocal collaborative filtering of spatially correlated noise

X-ray micro-tomography systems often suffer severe ring artifacts in reconstructed images. These artifacts are caused by defects in the detector, calibration errors, and fluctuations producing streak noise in the raw sinogram data. In this work, these streaks are modeled in the sinogram domain as additive stationary correlated noise upon logarithmic transformation. Based on this model, a streak removal procedure is proposed where the Block-Matching and 3-D (BM3D) filtering algorithm is applied across multiple scales, achieving state-of-the-art performance in both real and simulated data. Specifically, the proposed fully automatic procedure allows for attenuation of streak noise and the corresponding ring artifacts without creating major distortions common to other streak removal algorithms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Separation of Artifacts from Spin–Torque Ferromagnetic Resonance Measurements of Spin–Orbit Torque for the Low–Symmetry Van der Waals Semi–Metal ZrTe 3

Spin-orbit torques generated by exfoliated layers of the low-symmetry semi-metal ZrTe 3 are measured using the spin-torque ferromagnetic resonance (ST-FMR) technique. When the ZrTe 3 has a thickness greater than about 10 nm, artifacts due to spin pumping and/or resonant heating can cause the standard ST-FMR analysis to overestimate the true magnitude of the torque efficiency by as much as a factor of 30, and to indicate incorrectly that the spin-orbit torque depends strongly on the ZrTe 3 layer thickness. Artifact-free measurements can still be achieved over a substantial thickness range by the method developed recently to detect ST-FMR signals in the Hall geometry as well as the longitudinal geometry. ZrTe 3 /Permalloy samples generate a conventional in-plane anti-damping spin torque efficiency ξ$^{FL}_{∥}$ = 0.014 ± 0.004, and an unconventional in-plane field-like torque efficiency |ξ$^{FL}_{∥}$| = 0.003 ± 0.001. As a result, the out-of-plane anti-damping torque is negligible. It is suggested that artifacts similarly interfere with the standard ST-FMR analysis for other van der Waals samples thicker than about 10 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Arms Down Cone Beam CT Hepatic Angiography Performance Assessment: Vascular Imaging Quality and Imaging Artifacts

IntroductionThe practice of positioning patients’ arms above the head during catheter-injected hepatic arterial phase cone beam CT (A-CBCT) imaging has been inherited from standard CT imaging due to image quality concerns, but interrupts workflow and extends procedure time. We sought to assess A-CBCT image quality and artifacts with arms extended above the head versus down by the side.MethodsWe performed an IRB approved retrospective evaluation of reformatted and 3D-volume rendered images from 91 consecutive A-CBCTs (43 arms up, 48 arms down) acquired during hepatic tumor arterial embolization procedures. Two interventional radiologists reviewed all A-CBCT imaging and assigned vessel visualization scores (VVS) from 1 to 5, ranging from non-diagnostic to optimal visualization. Streak artifacts across axial images were rated from 1 to 3 based on resulting image quality (none to significant). Presence of respiratory or cardiac motion during acquisition, body mass index and radiation dose area product (DAP) were also recorded and analyzed. Univariate and multivariate analyses were used to assess the impact of arm position on VVS and imaging artifacts.ResultsVVS were not significantly associated with arm position during A-CBCT imaging. One reader reported more streak artifacts across axial images in the arms down group (p = 0.005). DAP was not statistically different between the groups (23.9 Gy cm{sup 2} [6.1–73.4] arms up, 26.1 Gy cm{sup 2} [4.2–102.6] arms down, p = 0.54).ConclusionA-CBCT angiography performed with the arms above the head is not superior for clinically relevant hepatic vascular visualization compared to imaging performed with the arms by the patient’s side.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detecting and Removing Data Artifacts in Hadamard Transform Ion Mobility-Mass Spectrometry Measurements

Applying Hadamard transform multiplexing to ion mobility separations (IMS) can significantly improve the signal-to-noise ratio and throughput for IMS coupled mass spectrometry (MS) measurements by increasing the ion utilization efficiency. However, it has been determined that both fluctuations in ion intensity as well as spatial shifts in the multiplexed data lower the signal-to-noise ratios and appear as noise in downstream processing of the data. To address this problem, we have developed a novel algorithm that discovers and eliminates data artifacts. The algorithm uses knowledge of the true signal peaks derived from the encoded data and allows for both artifacts and noise to be removed with high confidence, decreasing the likelihood of false identifications in subsequent data processing. The result is that IMS-MS can be applied to increase measurement sensitivity while avoiding artifacts that have previously limited its utility.

47 OTHER INSTRUMENTATION↗

DeepShadows: Separating low surface brightness galaxies from artifacts using deep learning

Searches for low-surface-brightness galaxies (LSBGs) in galaxy surveys are plagued by the presence of a large number of artifacts (e.g., objects blended in the diffuse light from stars and galaxies, Galactic cirrus, star-forming regions in the arms of spiral galaxies, etc.) that have to be rejected through time consuming visual inspection. In future surveys, which are expected to collect hundreds of petabytes of data and detect billions of objects, such an approach will not be feasible. We investigate the use of convolutional neural networks (CNNs) for the problem of separating LSBGs from artifacts in survey images. We take advantage of the fact that we have available a large number of labeled LSBGs and artifacts from the Dark Energy Survey, that we use to train, validate, and test a CNN model. That model, which we call DeepShadows , achieves a test accuracy of 92.0%, a significant improvement relative to feature-based machine learning models. We also study the ability to use transfer learning to adapt this model to classify objects from the deeper Hyper-Suprime-Cam survey, and we show that after the model is retrained on a very small sample from the new survey, it can reach an accuracy of 87.6%. Finally, these results demonstrate that CNNs offer a very promising path in the quest to study the low-surface-brightness universe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Novel Fast Helical 4D-CT Acquisition Technique to Generate Low-Noise Sorting Artifact–Free Images at User-Selected Breathing Phases

Purpose: To develop a novel 4-dimensional computed tomography (4D-CT) technique that exploits standard fast helical acquisition, a simultaneous breathing surrogate measurement, deformable image registration, and a breathing motion model to remove sorting artifacts. Methods and Materials: Ten patients were imaged under free-breathing conditions 25 successive times in alternating directions with a 64-slice CT scanner using a low-dose fast helical protocol. An abdominal bellows was used as a breathing surrogate. Deformable registration was used to register the first image (defined as the reference image) to the subsequent 24 segmented images. Voxel-specific motion model parameters were determined using a breathing motion model. The tissue locations predicted by the motion model in the 25 images were compared against the deformably registered tissue locations, allowing a model prediction error to be evaluated. A low-noise image was created by averaging the 25 images deformed to the first image geometry, reducing statistical image noise by a factor of 5. The motion model was used to deform the low-noise reference image to any user-selected breathing phase. A voxel-specific correction was applied to correct the Hounsfield units for lung parenchyma density as a function of lung air filling. Results: Images produced using the model at user-selected breathing phases did not suffer from sorting artifacts common to conventional 4D-CT protocols. The mean prediction error across all patients between the breathing motion model predictions and the measured lung tissue positions was determined to be 1.19 ± 0.37 mm. Conclusions: The proposed technique can be used as a clinical 4D-CT technique. It is robust in the presence of irregular breathing and allows the entire imaging dose to contribute to the resulting image quality, providing sorting artifact–free images at a patient dose similar to or less than current 4D-CT techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental procedures to mitigate electron beam induced artifacts during in situ fluid imaging of nanomaterials

Currently there are few standardized experimental practices in the field of fluid stage transmission electron microscopy. To obtain consistency in this emerging field, a crucial step is to establish the common artifacts and electron beam-sample interactions that can occur. Recently many unintended phenomena have been observed during in situ fluid stage scanning transmission electron microscopy (STEM) experiments, including growth of crystals on the fluid stage windows, repulsion of particles from the irradiated area, bubble formation, and the loss of atomic information during prolonged imaging of individual nanoparticles. Here we provide a comprehensive review of these fluid stage artifacts, and we present new experimental evidence that sheds light on their origins in terms of experimental apparatus issues and indirect electron beam sample interactions with the fluid layer. The results here will provide a methodology for minimizing fluid stage imaging artifacts and acquiring quantitative in situ observations of nanomaterial behavior in a liquid environment.

in situ fluid↗

Toward artifact-free data in Hadamard transform-based double multiplexing of ion mobility-Orbitrap mass spectrometry

The integration of ion mobility spectrometry (IMS) with trap-based mass spectrometer (MS) such as Orbitrap using the dual gate approach suffers from low duty cycle. Efforts to improve the duty cycle involve the utilization of Hadamard transform based double multiplexing which significantly improve the signal to noise ratio and duty cycle of the ion mobility – Orbitrap mass spectrometry (IM – Orbitrap MS) platform. However, significant fluctuations in ion intensity and the temporal shifts in the encoded data give rise to artifacts and noise in the demultiplexed data which significantly reduce the data quality and negate the benefits of multiplexing. We propose a new approach that identifies the true IM peaks and helps in eliminating the artifacts in the demultiplexed data leading to a decrease in false positives in subsequent data processing. The algorithm takes an analytical approach to first identify the position of the IM peak in the temporal domain, and then demultiplex and identify the true data making it easier for subsequent data processing. After the application of the algorithm, the quality of the IM-Orbitrap MS measurements was greatly improved because of the reduction in artifacts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards the development of high temperature comparison artifacts for radiation thermometry

This paper describes the methodology and first results of the development of high temperature fixed point artifacts of unknown temperature suitable for scale comparison purposes. This study is being undertaken at the Thermal Metrology Division of Inmetro, Brazil, as part of PhD studies. In this initial phase of the study two identical cobalt carbon eutectic cells were constructed and one doped with a known amount of copper. This was an attempt to achieve a controlled change in the transition temperature of the alloy during melting. Copper was chosen due to the relatively simple phase diagram it forms with carbon and cobalt. The cobalt, in powder form, was supplied by Alfa Aesar at 99.998 % purity, and was mixed with carbon powder (1,9 % by weight) of 99.9999 % purity. Complete filling of the crucible took 6 steps and was performed in a vertical furnace with graphite heating elements, in an inert gas atmosphere. The temperature measurements were performed using a KE LP3 radiation thermometer, which was previously evaluated for spectral responsivity, linearity and size-of-source effect (SSE). During these measurements, the thermometer stability was periodically checked using a silver fixed point blackbody maintained in a three zone furnace. The main purpose of the first part of this study is to dope a series of Co-C blackbody with differing amounts of copper, in order to alter their temperatures whilst still retaining good melting plateau performance. The long-term stability of the adjusted transition temperatures will also be investigated. Other dopants will be studied as the research progresses, and thermo chemical modeling will be performed in an attempt to understand the change in temperature with dopant concentration and so help select suitable dopants in the future. The overall objective is to construct comparison artifacts that have good performance, in terms of plateau shape and long-term temperature stability, but with unknown temperatures. These can then be used as comparison artifacts with no participant, except the pilot, knowing the temperature a priori.

36 MATERIALS SCIENCE↗

Neutron measurements of stresses in a test artifact produced by laser-based additive manufacturing

A stainless steel test artifact produced by Direct Metal Laser Sintering and similar to a proposed standardized test artifact was examined using neutron diffraction. The artifact contained a number of structures with different aspect ratios pertaining to wall thickness, height above base plate, and side length. Through spatial resolutions of the order of one millimeter the volumetric distribution of stresses in several was measured. It was found that the stresses peak in the tensile region around 500 MPa near the top surface, with balancing compressive stresses in the interior. The presence of a support structure (a one millimeter high, thin walled, hence weaker, lattice structure deposited on the base plate, followed by a fully dense AM structure) has only minor effects on the stresses.

36 MATERIALS SCIENCE↗

Artifact reduction in industrial computed tomography via data fusion

As the most stressed part of a gas turbine the first row of turbine blades is not only a challenge for the materials used. Also the testing of these parts have to meet the highest standards. Computed tomography (CT) as the technique which could reveal the most details also provides the biggest challenges [1]: A full penetration of large sized turbine blades is often only possible at high X-ray voltages causing disproportional high costs. A reduction of the X-ray voltage is able to reduce these arising costs but yields non penetration artifacts in the reconstructed CT image. In most instances, these artifacts manifests itself as blurred and smeared regions at concave edges due to a reduced signal to noise ratio. In order to complement the missing information and to increase the overall image quality of our reconstruction, we use further imaging modalities such as a 3-D Scanner and ultrasonic imaging. A 3-D scanner is easy and cost effective to implement and is able to acquire all relevant data simultaneously with the CT projections. If, however, the interior structure is of supplemental interest, an ultrasonic imaging method is additionally used. We consider this data as a priori knowledge to employ them in an iterative reconstruction. To do so, standard iterative reconstruction methods are modified to incorporate the a priori data in a regularization approach in combination with minimizing the total variation of our image. Applying this procedure on turbine blades, we are able to reduce the apparent artifacts almost completely.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A TEMPORAL MAP IN GEOSTATIONARY ORBIT: THE COVER ETCHING ON THE EchoStar XVI ARTIFACT

Geostationary satellites are unique among orbital spacecraft in that they experience no appreciable atmospheric drag. After concluding their respective missions, geostationary spacecraft remain in orbit virtually in perpetuity. As such, they represent some of human civilization's longest lasting artifacts. With this in mind, the EchoStar XVI satellite, to be launched in fall 2012, will play host to a time capsule intended as a message for the deep future. Inspired in part by the Pioneer Plaque and Voyager Golden Records, the EchoStar XVI Artifact is a pair of gold-plated aluminum jackets housing a small silicon disk containing 100 photographs. The Cover Etching, the subject of this paper, is etched onto one of the two jackets. It is a temporal map consisting of a star chart, pulsar timings, and other information describing the epoch from which EchoStar XVI came. The pulsar sample consists of 13 rapidly rotating objects, 5 of which are especially stable, having spin periods <10 ms and extremely small spin-down rates. In this paper, we discuss our approach to the time map etched onto the cover and the scientific data shown on it, and we speculate on the uses that future scientists may have for its data. The other portions of the EchoStar XVI Artifact will be discussed elsewhere.

79 ASTRONOMY AND ASTROPHYSICS↗

Cusp-artifacts in high order Superresolution Optical Fluctuation Imaging

Superresolution optical fluctuation imaging (SOFI) is a simple and affordable super-resolution imaging technique, and attracted a growing community over the past decade. However, the theoretical resolution enhancement of high order SOFI is still not fulfilled. In this study, we identify “cusp artifacts” in high order SOFI images, and show that the high-order cumulants, odd-order moments and balanced-cumulants (bSOFI) are highly vulnerable to cusp artifacts. Our study provides guidelines for developing and screening for fluorescence probes, and improving data acquisition for SOFI. The new insight is important to inspire positive utilization of the cusp artifacts.

47 OTHER INSTRUMENTATION↗

Calibration of megavoltage cone-beam CT for radiotherapy dose calculations: Correction of cupping artifacts and conversion of CT numbers to electron density

Megavoltage cone-beam CT (MV CBCT) is used for three-dimensional imaging of the patient anatomy on the treatment table prior to or just after radiotherapy treatment. To use MV CBCT images for radiotherapy dose calculation purposes, reliable electron density (ED) distributions are needed. Patient scatter, beam hardening and softening effects result in cupping artifacts in MV CBCT images and distort the CT number to ED conversion. A method based on transmission images is presented to correct for these effects without using prior knowledge of the object's geometry. The scatter distribution originating from the patient is calculated with pencil beam scatter kernels that are fitted based on transmission measurements. The radiological thickness is extracted from the scatter subtracted transmission images and is then converted to the primary transmission used in the cone-beam reconstruction. These corrections are performed in an iterative manner, without using prior knowledge regarding the geometry and composition of the object. The method was tested using various homogeneous and inhomogeneous phantoms with varying shapes and compositions, including a phantom with different electron density inserts, phantoms with large density variations, and an anthropomorphic head phantom. For all phantoms, the cupping artifact was substantially removed from the images and a linear relation between the CT number and electron density was found. After correction the deviations in reconstructed ED from the true values were reduced from up to 0.30 ED units to 0.03 for the majority of the phantoms; the residual difference is equal to the amount of noise in the images. The ED distributions were evaluated in terms of absolute dose calculation accuracy for homogeneous cylinders of different size; errors decreased from 7% to below 1% in the center of the objects for the uncorrected and corrected images, respectively, and maximum differences were reduced from 17% to 2%, respectively. The presented method corrects the MV CBCT images for cupping artifacts and extracts reliable ED information of objects with varying geometries and composition, making these corrected MV CBCT images suitable for accurate dose calculation purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗