Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval

The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the caval lumen detected on 3-D CV that were not detected on sCV (p < 0.001). Filter apex tilt detection differed significantly (p < 0.001) between sCV and 3-D CV, with 3-D CV being more accurate. The filter apex abutted the IVC wall in 10 patients (33%) on 3-D CV, but this was diagnosed in only 3 patients (10%) with sCV. Thrombus was detected in 8 patients (27%), 1 thrombus of which was seen only on 3-D CV, and treatment was changed in this patient because of thrombus size. Mean effective radiation doses for 3-D CV were approximately two times higher than for sCV (1.68 vs. 0.86 mSv), whereas skin doses were three times lower (12.87 vs. 35.86 mGy). Compared with sCV, performing 3-D CV before optional IVC filter retrieval has the potential to improve assessment of filter arms or legs projecting beyond the caval lumen, filter orientation, and thrombus burden.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Two Pseudoaneurysms Originating From the Left Ventricle

A 67-year-old woman resented with an acute type A aortic dissection, which was treated surgically with aortic valve replacement as a composite graft with reimplantation of the coronary arteries. At the end of surgery, a left-ventricular venting catheter was placed through the apex and closed with a buffered suture. Consecutive computed tomography (CT) examinations verified a growing apex pseudoaneurysm. Communication between the ventricle and the pseudoaneurysm was successfully closed with an Amplatz septal plug by the transfemoral route. Follow-up CT showed an additional pseudoaneurysm, which also was successfully closed using the same method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Apical sparing pattern of left ventricular myocardial {sup 99m}Tc-HMDP uptake in patients with transthyretin cardiac amyloidosis

Background: A decreased longitudinal strain in basal segments with a base-to-apex gradient has been described in patients with cardiac amyloidosis (CA). Objectives: Aim was to investigate the left ventricular (LV) regional distribution of early-phase {sup 99m}Tc-Hydroxymethylene diphosphonate ({sup 99m}Tc-HMDP) uptake in patients with transthyretin-related cardiac amyloidosis (TTR-CA). Methods: All patients underwent a whole-body planar {sup 99m}Tc-HMDP scintigraphy acquired at 10-min post-injection (early-phase) followed by a thorax SPECT/CT. The segmental uptake (expressed as % of maximal myocardial HMDP uptake) was investigated on the AHA 17-segment model and 3-segment model (basal, mid-cavity, apical). Results: Sixty-one TTR-CA patients were included of whom 29 were wild-type (wt-TTR-CA) and 32 had hereditary TTR-CA (m-TTR-CA). Early myocardial {sup 99m}Tc-HMDP uptake occurred in all TTR-CA. In all patients, segmental analysis of the LV myocardial distribution of {sup 99m}Tc-HMDP uptake showed an increased median uptake (interquartile range) in basal/mid-cavity segments compared to the lowest median uptake of apical segments (respectively, 79% [72%-86%] vs. 72% [64%-81%]; P < 10{sup −6}). This pattern was similar in wt-TTR-CA group (78% [70%-84%] vs. 70% [61%-81%]; P < 10{sup −6}), in m-TTR-CA group (80% [74%-86%] vs. 73 [66%-82%]; P < 10{sup −7}) and remained constant independently of the TTR mutation subtype with P ranging 10{sup −5} to 0.03. Conclusions: Early-phase myocardial scintigraphy identified regional distribution of {sup 99m}Tc-HMDP uptake characterized by a base-to-apex gradient, corroborating echocardiographic, and cardiac magnetic resonance findings. This apical sparing pattern was similar across TTR-CA and TTR mutation subtypes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of micro-fin tube geometry parameters on evaporator material savings

A Performance Evaluation Criteria (PEC) analysis is presented that explores the influence of the micro-fin tube geometry on the required material volume. The analysis was done using a local flow boiling model, which can quantify the effect of fin parameters and the tube diameter. The PEC was done while requiring that the compared surfaces satisfy the same heat duty and pressure drop. The following tube parameters and ranges were explored: tube diameter (3 mm ≤ D o ≤ 6 mm), fin base thickness (0.12 mm ≤ t bf ≤ 0.29 mm), helix angle (6° ≤ α ≤ 30°), fin apex angle (11° ≤ β ≤ 22°), total number of fins (43 ≤ n f ≤ 70), and the fin height (0.11 mm ≤ e ≤ 0.3 mm). The tube that provided the smallest material requirements within the examined parameter ranges had: D o = 3 mm, t bf = 0.12 mm, α = 6°, β = 11°, n f = 43, and e = 0.3 mm. In general, small D o and t bf and large n f and e provided the best performance and work to minimize the required material volume to provide a given heat duty and pressure drop. The helix and the fin-tip apex angles were found to have very little influence on the performance for the examined range of parameters and angles associated with the lowest production cost should be chosen.

Evaporation↗

Radiographic and Anatomic Basis for Prostate Contouring Errors and Methods to Improve Prostate Contouring Accuracy

Purpose: Use of highly conformal radiation for prostate cancer can lead to both overtreatment of surrounding normal tissues and undertreatment of the prostate itself. In this retrospective study we analyzed the radiographic and anatomic basis of common errors in computed tomography (CT) contouring and suggest methods to correct them. Methods and Materials: Three hundred patients with prostate cancer underwent CT and magnetic resonance imaging (MRI). The prostate was delineated independently on the data sets. CT and MRI contours were compared by use of deformable registration. Errors in target delineation were analyzed and methods to avoid such errors detailed. Results: Contouring errors were identified at the prostatic apex, mid gland, and base on CT. At the apex, the genitourinary diaphragm, rectum, and anterior fascia contribute to overestimation. At the mid prostate, the anterior and lateral fasciae contribute to overestimation. At the base, the bladder and anterior fascia contribute to anterior overestimation. Transition zone hypertrophy and bladder neck variability contribute to errors of overestimation and underestimation at the superior base, whereas variable prostate-to-seminal vesicle relationships with prostate hypertrophy contribute to contouring errors at the posterior base. Conclusions: Most CT contouring errors can be detected by (1) inspection of a lateral view of prostate contours to detect projection from the expected globular form and (2) recognition of anatomic structures (genitourinary diaphragm) on the CT scans that are clearly visible on MRI. This study shows that many CT prostate contouring errors can be improved without direct incorporation of MRI data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effectiveness of Using Fewer Implanted Fiducial Markers for Prostate Target Alignment

Purpose: To evaluate the impact of the number and location of intraprostatic fiducial markers on the accuracy and reproducibility of daily prostate target alignment and to evaluate the migration of such markers. Methods and Materials: Three gold fiducial markers were implanted transrectally under ultrasound guidance near the apex, middle, and base of the prostate in 10 prostate cancer patients. The patients had pretreatment in-room computed tomography (CT) scans three times a week, for approximately 25 CT scans per patient during the 8-week treatment course. A total of 1280 alignments were performed using different alignment scenarios: whole-prostate soft tissue alignment (the gold standard), bone alignment, and seven permutations of alignments using one, two, or three fiducial markers. The results of bone alignment and fiducial alignment were compared with the results of whole-prostate alignment. Fiducial migration was also evaluated. Results: Single-fiducial-marker alignment was more accurate and reproducible than bone alignment. However, due to organ deformation, single fiducial markers did not always reliably represent the position of the entire prostate. The use of two-fiducial combinations was more accurate and reproducible than single-fiducial alignment, and use of all three fiducials was the best. Use of an apex fiducial together with a base fiducial rivaled the use of all three fiducials markers together. Fiducial migration was minimal. Conclusions: The number and the location of implanted fiducial markers affect the accuracy and reliability of daily prostate target alignment. The use of two or more fiducial markers is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alternative Dose for Choroidal Melanoma Treated With an Iodine-125 Radioactive Plaque: A Single-Institution Retrospective Study

Purpose: The Collaborative Ocular Melanoma Study (COMS) established iodine-125 plaque brachytherapy as an accepted standard treatment for medium-size choroidal melanoma. In the COMS, the prescription dose was 85 Gy. This is a retrospective review of our outcomes in patients treated with lower doses than those used in the COMS. Methods and Materials: From 1990 to 2004, 62 patients were treated with iodine-125 plaque brachytherapy for choroidal melanoma. COMS eye plaques were used with dose prescribed to the apex of the tumor. The median and average dose rates at the tumor apex were 63.5 cGy/h and 62.7 cGy/h, respectively. The median and average total doses were 63.0 Gy and 62.5 Gy (range, 56-69 Gy), respectively. The median and mean durations of implant were 100.0 hours and 101.1 hours (range, 71-165 hours). Results: Median follow-up time was 58.2 months. The 5-year outcomes including overall survival, disease-free survival, cause-specific survival, local failure, secondary enucleation rate, and visual acuity (VA) <20/200 were estimated using the Kaplan-Meier method. Overall, there were 7 local failures, 4 distant failures, and 10 secondary enucleations (6 due to local failure and 4 due to treatment complications). Univariate analysis was performed to identify significant prognostic factors associated with disease-free survival (baseline VA in tumor eye, tumor shape), cause-specific survival (diabetic retinopathy), local failure (none found), secondary enucleation rate (diabetic retinopathy, basal tumor dimension) and VA <20/200 (diabetic retinopathy, tumor shape, age, retinal detachment, treatment depth, and history of vision-limiting condition). Conclusions: Our survival and local control outcomes are comparable to those of the COMS. However, VA at 5 years seems to be better. Lower doses of radiation could potentially lead to better visual outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnitude of Interfractional Vaginal Cuff Movement: Implications for External Irradiation

Purpose: To quantify the extent of interfractional vaginal cuff movement in patients receiving postoperative irradiation for cervical or endometrial cancer in the absence of bowel/bladder instruction. Methods and Materials: Eleven consecutive patients with cervical or endometrial cancer underwent placement of three gold seed fiducial markers in the vaginal cuff apex as part of standard of care before simulation. Patients subsequently underwent external irradiation and brachytherapy treatment based on institutional guidelines. Daily megavoltage CT imaging was performed during each external radiation treatment fraction. The daily positions of the vaginal apex fiducial markers were subsequently compared with the original position of the fiducial markers on the simulation CT. Composite dose-volume histograms were also created by summing daily target positions. Results: The average ({+-} standard deviation) vaginal cuff movement throughout daily pelvic external radiotherapy when referenced to the simulation position was 16.2 {+-} 8.3 mm. The maximum vaginal cuff movement for any patient during treatment was 34.5 mm. In the axial plane the mean vaginal cuff movement was 12.9 {+-} 6.7 mm. The maximum vaginal cuff axial movement was 30.7 mm. In the craniocaudal axis the mean movement was 10.3 {+-} 7.6 mm, with a maximum movement of 27.0 mm. Probability of cuff excursion outside of the clinical target volume steadily dropped as margin size increased (53%, 26%, 4.2%, and 1.4% for 1.0, 1.5, 2.0, and 2.5 cm, respectively.) However, rectal and bladder doses steadily increased with larger margin sizes. Conclusions: The magnitude of vaginal cuff movement is highly patient specific and can impact target coverage in patients without bowel/bladder instructions at simulation. The use of vaginal cuff fiducials can help identify patients at risk for target volume excursion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-Based Evaluation of the Vaginal Cuff in Brachytherapy Planning: Are We Missing the Target?

Purpose: Although recurrences and toxicity occur after vaginal cuff (VC) brachytherapy, little is known about dosimetry due to the inability to clearly visualize the VC on computed tomography (CT). T2-weighted (T2W) magnetic resonance imaging (MRI) is superior to CT in this setting, and we hypothesized that it could provide previously unascertainable dosimetric information. Methods and Materials: In a cohort of 32 patients who underwent cylinder-based brachytherapy for endometrial cancer with available MR simulation images, the VC was retrospectively contoured on T2W images, and cases were replanned to treat the upper VC to a dose of 7 Gy/fraction prescribed to 5 mm. Relevant dose-volume parameters for the VC were calculated. Results: T2W MRI identified significant underdosing not observed on CT or T1-weighted imaging. Over two-thirds (69%) of patients had at least 1 cm{sup 3} of VC that received less than 75% of the prescription dose and half (50%) of patients had a least 1 cm{sup 3} of VC that received less than 50% of the prescription dose. The mean minimum point dose to the VC was 2.4 Gy, or 34% of the intended prescription dose (range: 0.53-6.4 Gy). Conclusions: We identified previously unreported VC underdosing in over two-thirds of our patients, with most of these patients having volumes of undistended VC that received less than half of the prescription dose. The maximum dimension was along the craniocaudal axis in some patients or left-right/anterior-posterior axis in others, suggesting that suture material may be restricting access to the vaginal apex and that alternative applicators may be needed when the diameter of the apex is larger than the introitus. Additional follow-up will be needed to determine whether underdosing is associated with isolated VC failure or whether low failure rates across the cohort suggest that some patients are being exposed to excessive dose and unnecessary risk of toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anion vacancy ordering in Sr{sub 7}Mn{sub 4}O{sub 15-x} phases

The synthesis of phases of composition Sr{sub 7}Mn{sub 4}O{sub 15-x} 0<x<3 is reported via the topotactic manipulation of the anion lattice of Sr{sub 7}Mn{sub 4}O{sub 15}. In addition the reduced, cation substituted phases BaSr{sub 6}Mn{sub 4}O{sub 13} and Sr{sub 6}CaMn{sub 4}O{sub 13} are described. Structural characterisation using powder X-ray and neutron diffraction data reveals that in all phases anions are selectively removed from sites which link the MnO{sub 6} octahedra in the structure in an apex-sharing manner. An explanation based on the total lattice energy of the anion deficient phases is presented to account for this unusual selectivity. - Graphical abstract: Topotactic reduction of Sr{sub 7}Mn{sub 4}O{sub 15} selectively removes apex-linked oxide ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The synthesis and characterisation of LaCa{sub 2}Fe{sub 2}GaO{sub 8}

The synthesis and characterisation of LaCa{sub 2}Fe{sub 2}GaO{sub 8} is described. Neutron powder diffraction data reveal LaCa{sub 2}Fe{sub 2}GaO{sub 8} adopts an anion-vacancy ordered, 'triple layer' structure consisting of an OOT{sub L}OOT{sub R} stacking sequence of layers of (Fe/Ga)O{sub 6} octahedra (O) and (Fe/Ga)O{sub 4} tetrahedra (T), related to that of the 4-layer brownmillerite structures (a=5.4784(1) A, b=22.6780(4) A, c=5.6007(1) A, space group Pbma). The apex-linked chains of tetrahedra within structure of LaCa{sub 2}Fe{sub 2}GaO{sub 8} exhibit a cooperative twisting distortion which alternates in direction between adjacent layers of tetrahedra, the first time such an arrangement has been seen in a triple-layer phase. Magnetisation and neutron diffraction data reveal that LaCa{sub 2}Fe{sub 2}GaO{sub 8} exhibits two magnetic ordering transitions. On cooling below 550 K the phase adopts a state with short range antiferromagnetic coupling within each double layer of (Fe/Ga)O{sub 6} octahedra, but only weak coupling between layers. On cooling below 470 K full three-dimensional, G-type antiferromagnetic order is observed. - Graphical abstract: LaCa{sub 2}Fe{sub 2}GaO{sub 8} adopts an anion-vacancy ordered, 'triple layer' structure consisting of an OOT{sub L}OOT{sub R} stacking sequence of layers of FeO{sub 6} octahedra (O) and GaO{sub 4} tetrahedra (T), in which the chains of apex-linked tetrahedra exhibit a cooperative twisting distortion which alternates in direction between adjacent layers of tetrahedra. On cooling below 550 K, LaCa{sub 2}Fe{sub 2}GaO{sub 8} adopts a state with strong two-dimensional antiferromagnetic order within each double layer of FeO{sub 6} octahedra, but only weak coupling between layers. On cooling below 470 K full three-dimensional antiferromagnetic order is observed. Highlights: Black-Right-Pointing-Pointer LaCa{sub 2}Fe{sub 2}GaO{sub 8} exhibits a novel anion-vacancy ordered triple-layer structure type. Black-Right-Pointing-Pointer New structure variant rationalised on the basis of strucutral parameters. Black-Right-Pointing-Pointer Multiple magnetic transitions: paramagnetic-two-dimensional-three-dimensional.

36 MATERIALS SCIENCE↗

Transformation of c-oriented nanowall network to a flat morphology in GaN films on c-plane sapphire

Highlights: {yields} High quality wurtzite structures GaN nanowall network formed on c-plane sapphire. {yields} Tapering of nanowalls at the apex cause electron confinement effects. {yields} Temperature dependent transformation of the six fold nanowall network to a flat morphology. {yields} Growth kinetics is influenced by adatom diffusion, interactions and bonding for GaN layer. -- Abstract: The work significantly optimizes growth parameters for nanostructured and flat GaN film in the 480-830 {sup o}C temperature range. The growth of ordered, high quality GaN nanowall hexagonal honeycomb like network on c-plane sapphire under nitrogen rich (N/Ga ratio of 100) conditions at temperatures below 700 {sup o}C is demonstrated. The walls are c-oriented wurtzite structures 200 nm wide at base and taper to 10 nm at apex, manifesting electron confinement effects to tune optoelectronic properties. For substrate temperatures above 700 {sup o}C the nanowalls thicken to a flat morphology with a dislocation density of 10{sup 10}/cm{sup 2}. The role of misfit dislocations in the GaN overlayer evolution is discussed in terms of growth kinetics being influenced by adatom diffusion, interactions and bonding at different temperatures. The GaN films are characterized by reflection high energy electron diffraction (RHEED), field emission scanning electron (FESEM), high resolution X-ray diffraction (HRXRD) and cathodoluminescence (CL).

36 MATERIALS SCIENCE↗

Dosimetric differences between intraoperative and postoperative plans using Cs-131 in transrectal ultrasound–guided brachytherapy for prostatic carcinoma

The aim of the study was to investigate the differences between intraoperative and postoperative dosimetry for transrectal ultrasound–guided transperineal prostate implants using cesium-131 ({sup 131}Cs). Between 2006 and 2010, 166 patients implanted with {sup 131}Cs had both intraoperative and postoperative dosimetry studies. All cases were monotherapy and doses of 115 were prescribed to the prostate. The dosimetric properties (D{sub 90}, V{sub 150}, and V{sub 100} for the prostate) of the studies were compared. Two conformity indices were also calculated and compared. Finally, the prostate was automatically sectioned into 6 sectors (anterior and posterior sectors at the base, midgland, and apex) and the intraoperative and postoperative dosimetry was compared in each individual sector. Postoperative dosimetry showed statistically significant changes (p < 0.01) in every dosimetric value except V{sub 150}. In each significant case, the postoperative plans showed lower dose coverage. The conformity indexes also showed a bimodal frequency distribution with the index indicating poorer dose conformity in the postoperative plans. Sector analysis revealed less dose coverage postoperatively in the base and apex sectors with an increase in dose to the posterior midgland sector. Postoperative dosimetry overall and in specific sectors of the prostate differs significantly from intraoperative planning. Care must be taken during the intraoperative planning stage to ensure complete dose coverage of the prostate with the understanding that the final postoperative dosimetry will show less dose coverage.

61 RADIATION PROTECTION AND DOSIMETRY↗

The BTFEL, an infrared free-electron laser amplifier based on a new-design short-period superconducting tape undulator

The development of undulator technologies capable of generating sub-cm undulator periods is assuming an increasing importance in X-ray free electron laser (FEL) applications. Indeed, such devices jointly with the high brightness electron beams already demonstrated at operating facilities would allow for lower energy, more compact electron linacs with a beneficial impact on the size and cost of X-ray FEL facilities. A novel design super-conducting undulator is being developed at the Lawrence Berkeley National Laboratory (LBNL) with the potential of sub-cm periods with reasonably large undulator parameter and gap. The potential and capability of such undulator technology need to be experimentally demonstrated. In this paper, the possibility of constructing an infrared FEL by combining the new undulator with the high brightness beam from the APEX injector facility at LBNL is investigated. Calculations show that the resulting FEL, when operated in self-amplified-spontaneous-emission mode, is expected to deliver a saturated power of almost a MW within a ~4m undulator length, in a single-spike of coherent radiation at ~2μm wavelength. It will be also shown that the small-period of the undulator associated with the relatively low energy of the APEX beam, forces the FEL to operate in a regime with unusual and interesting characteristics. The alternative option of laser seeding the FEL is also briefly examined, showing the potential to reduce the saturation length even further.

47 OTHER INSTRUMENTATION↗

RF design of APEX2 two-cell continuous-wave normal conducting photoelectron gun cavity based on multi-objective genetic algorithm

High brightness, high repetition rate electron beams are key components for optimizing the performance of next generation scientific instruments, such as MHz-class X-ray Free Electron Laser (XFEL) and Ultra-fast Electron Diffraction/Microscopy (UED/UEM). In the Advanced Photo-injector EXperiment (APEX)at Berkeley Lab, a photoelectron gun based on a 185.7 MHz normal conducting re-entrant RF cavity, has been proven to be a feasible solution to provide high brightness, high repetition rate electron beam for both XFEL and UED/UEM. Based on the success of APEX, a new electron gun system, named APEX2, has been under development to further improve the electron beam brightness. For APEX2, we have designed a new 162.5 MHz two-cell photoelectron gun and achieved a significant increase on the cathode launching field and the beam exit energy. For a fixed charge per bunch, these improvements will allow for the emittance reduction and hence to an increased beam brightness. The design of APEX2 gun cavity is a complex problem with multiple design goals and restrictions, some even competing each other. In conclusion, for a systematic and comprehensive search for the optimized cavity geometry, we have developed and implemented a novel optimization method based on the Multi-Objective Genetic Algorithm (MOGA).

47 OTHER INSTRUMENTATION↗

Bioinformatic analysis of neurotropic HIV envelope sequences identifies polymorphisms in the gp120 bridging sheet that increase macrophage-tropism through enhanced interactions with CCR5

Macrophages express low levels of the CD4 receptor compared to T-cells. Macrophage-tropic HIV strains replicating in brain of untreated patients with HIV-associated dementia (HAD) express Envs that are adapted to overcome this restriction through mechanisms that are poorly understood. Here, bioinformatic analysis of env sequence datasets together with functional studies identified polymorphisms in the β3 strand of the HIV gp120 bridging sheet that increase M-tropism. D197, which results in loss of an N-glycan located near the HIV Env trimer apex, was detected in brain in some HAD patients, while position 200 was estimated to be under positive selection. D197 and T/V200 increased fusion and infection of cells expressing low CD4 by enhancing gp120 binding to CCR5. These results identify polymorphisms in the HIV gp120 bridging sheet that overcome the restriction to macrophage infection imposed by low CD4 through enhanced gp120–CCR5 interactions, thereby promoting infection of brain and other macrophage-rich tissues. - Highlights: • We analyze HIV Env sequences and identify amino acids in beta 3 of the gp120 bridging sheet that enhance macrophage tropism. • These amino acids at positions 197 and 200 are present in brain of some patients with HIV-associated dementia. • D197 results in loss of a glycan near the HIV Env trimer apex, which may increase exposure of V3. • These variants may promote infection of macrophages in the brain by enhancing gp120–CCR5 interactions.

60 APPLIED LIFE SCIENCES↗

Effect of Single-Layer MoS 2 on the Geometry, Electronic Structure, and Reactivity of Transition Metal Nanoparticles

We present results of ab initio density functional theory (DFT) based calculations of the geometry, electronic structure, and reactivity of subnanometer-sized (29-atom) transition metal nanoparticles (NPs) (Cu 29 , Ag 29 , and Au 29 ) supported on single-layer MoS 2 . As compared to its pristine form, defect-laden MoS 2 (with a S vacancy row) has relatively larger effect on the above properties of the NPs. The NPs bind more strongly on defect-laden than on pristine MoS 2 (in the order Cu 29 > Ag 29 > Au 29 ), confirming the important role of vacancies in stabilizing the NPs on the support. The presence of vacancies also leads to an increase in charge transfer from the NPs to MoS 2 (with the same elemental trend as for their binding energy) and to a shift of the d-band center of the NPs further toward the Fermi level, in turn influencing their propensity toward chemical activity. We examine the adsorption and dissociation of O 2 as the prototype reactions and find that there is no barrier for O 2 to adsorb on top of an atom at the NP apex, where the frontier orbitals are localized, and that the dissociation channel proceeds through a chemisorbed state. The presence of the support leads to increase in the number of sites at which O 2 can adsorb with similar binding energy (<0.1 eV difference). Interestingly, energy barriers for both dissociation and recombination of O 2 , when adsorbing at the NP apex, increase in the presence of the MoS 2 support. However, since the increase in the barrier for recombination is much larger than for dissociation, the latter should be more favored. Lastly, in particular, for defect-laden MoS 2 supported Au 29 the recombination faces a barrier of 1.36 eV whereas the dissociation does 0.5 eV, implying that the defect-laden support may significantly improve the catalytic performance of Au29 toward oxidation reaction.

36 MATERIALS SCIENCE↗

Imaging Plasmons with Sub-2 nm Spatial Resolution via Tip-Enhanced Four-Wave Mixing

Four-wave mixing at plasmonic tip-sample nanojunctions may be used to visualize plasmonic fields with sub-2nm spatial resolution under ambient laboratory conditions. We illustrate the latter using a gold-coated atomic force microscopy probe irradiated with a pair of near-IR femtosecond laser pulses and used to interrogate plasmonic gold nanoplates and silver nanocubes. Through diagnostic polarization-dependent tip-only measurements, we illustrate that the 4-wave mixing signal is localized to the tip apex. The apex-bound signal is further enhanced when the tip is located near plasmonic nanoparticles. Overall, this work paves the way for visualizing coherent electronic and vibrational dynamics with joint femtosecond temporal and few-nanometer spatial resolution under ambient conditions.

Wang, Chih-Feng↗