A study on computational fluid dynamics modeling of a refrigerated container for COVID-19 vaccine distribution with experimental validation

A key issue with the distribution of vaccines to prevent COVID-19 is the temperature level required during transport, storage, and distribution. Typical refrigerated transport containers can provide a temperature-controlled environment down to -30 °C. However, the Pfizer vaccine must be carefully transported and stored under a lower temperature between -80 °C and -60 °C. One way to provide the required temperature is to pack the vaccine vials into small packages containing dry ice. Dry ice sublimates from a solid to a gas, which limits the allowable transport duration. This can be mitigated by transporting in a -30 °C refrigerated container. Moreover, because the dry ice will sublimate and thereby release CO 2 gas into the transport container, monitoring the CO 2 concentration within the refrigerated container is also essential. In the present work, a 3D computational fluid dynamics model was developed based on a commercially available refrigerated container and validated with experimental data. The airflow, temperature distribution, and CO 2 concentration within the container were obtained from the simulations. The modeling results can provide guidance on preparing experimental setups, thus saving time and lowering cost, and also provide insight into safety precautions needed to avoid hazardous conditions associated with the release of CO 2 during vaccine distribution.

59 BASIC BIOLOGICAL SCIENCES↗

Numerical analysis of air dehumidification through electrospray-enhanced vortical flow cyclone separator

The dehumidification of air is a highly energy-intensive process, typically requiring vapor compression systems to cool the air significantly below its dew point temperature. Here, this study numerically investigates air dehumidification achieved by electrostatic and dielectrophoresis forces in a converging duct and centrifugal principles in cyclone separators. An electrospray was employed to energize water droplets, which then captured water vapor via dielectrophoresis. A novelty of the present study is the inclusion of a cyclone separator positioned downstream of the electrospray. This combination increased the dehumidification efficiency and controlled the flow of the condensate. By integrating electrospray technology and applying an electric field, this study examines the impact of particle separation efficiency, pressure drops, and cyclone performance on air dehumidification. The control parameters for air dehumidification were investigated. Three cyclones were modelled for airflow rates of 5 cubic feet per minute [cfm] (0.0024 m 3 /s), 38 cfm (0.0179 m 3 /s), and 200 cfm (0.094 m 3 /s). The results indicated air dehumidification was up to 5.7 % under environmental conditions, similar to those used to validate the CFD model. The degree of air dehumidification was primarily influenced by the electric charge acquired by the water droplets, their flight trajectory, and the vorticity intensity within the cyclone. Air dehumidification could increase by up to 13 % by increasing the number of droplets injected into the air stream, the flight time, and the electrical charge. The breakdown electric field strength threshold near the electrospray was a limiting factor for further enhancing dehumidification performance. This study examines the optimization of an electro-assisted dehumidification system that includes cyclone-based droplet separation through numerical analysis. The results provide insights into the design of energy-efficient air treatment technologies.

42 ENGINEERING↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Particle-wall heat transfer in narrow-channel bubbling fluidized beds for thermal energy storage

Robust metal oxide particles can provide low-cost and stable thermal energy storage (TES) to temperatures up to 1200 °C or higher. The transfer of heat into and out of the particles in cost-effective high-temperature particle heat exchangers remains a principal challenge to implementing particle-based TES. The present work expands on prior studies of particle-wall heat transfer in narrow-channel fluidized beds operated in the bubbling fluidization regime. Batch-mode experiments with various oxide particles over a range of temperatures and airflow rates indicate that particle-wall heat transfer increases with higher bed temperature and decreasing particle size. Measured particle-wall heat transfer coefficients in a 12 mm deep channel are fit to a Nusselt number correlation proportional to a non-monotonic function of excess fluidization velocity. Particle-wall heat transfer coefficients rise rapidly with excess fluidization velocities until reaching a maximum at intermediate air velocities due to a trade-off between enhanced transverse particle mixing and decreasing particle volume fraction with increased fluidization velocity. The heat transfer coefficient reaches a maximum of ≈ 400% of values without fluidization for oxide particles ranging in diameter d p from 159 to 408 μm. For the smallest particles tested, composed of olivine sand, particle-wall heat transfer coefficients peak above 1100 Wm –2 K –1 at 450 °C. 100-h tests at 500 °C and near-optimal heat transfer fluidization velocities indicated minimal wall wear or oxide scaling. Furthermore, high particle-wall heat transfer coefficients suggest narrow channel fluidized beds as a potential pathway for reducing the required surface area and cost of high-temperature particle heat exchangers, as needed in large-scale thermal energy storage applications.

14 SOLAR ENERGY↗

Experimental measurements of fuel and water crossover in an active DMFC

This work measured polarization curves as well as the high-frequency resistance of active direct methanol fuel cell (DMFC) operates at around 80 °C with active controls of temperature, methanol concentration, airflow rate, and relative humidity. The relative humidity of the air did not have noticeable impacts on the fuel cell unless the operating temperature was near the evaporation temperature of water (100 °C). The hydrophobic water management layer (WML) between the membrane electrode assembly (MEA) and cathode air channel increases the mass transfer resistance and improves the water retention in MEA. Adding a WML increased the peak power density, decreased the ohmic resistance, and improved the fuel efficiency of the fuel cell, especially when it operated near 100 °C. This study also quantitatively measured methanol and water crossover as well as the fuel efficiency at different operating currents. The fuel efficiency increased significantly with the increase of the current density. Using a hydrophobic fuel management layer (FML) between the anode fuel channel and MEA reduced the fuel and water crossover rates and increased the ohmic resistance due to the decrease of the water content of the Nafion membrane. The FML improved fuel efficiency by reducing the methanol crossover. The combination of the FML and WML enabled the steady operation of DMFC using highly concentrated methanol solutions (up to 75 wt%).

08 HYDROGEN↗

Excipient screening by lyophilization provides insights into spray drying formulations for nanoparticle vaccines

Nanoparticles have shown great promise as delivery platforms in the development of tunable and safe vaccines. Nanolipoprotein particles (NLPs), also known as nanodiscs, are discoidal nanoparticles composed of a lipid bilayer stabilized at their periphery by apolipoproteins. Under the right conditions, the NLP self-assembly process is highly customizable in terms of lipids and apolipoprotein constituents, allowing for tunable physical and chemical characteristics. This flexibility allows a wide range of vaccine antigens and adjuvants to be incorporated onto the NLP platform for tailored vaccine design. The stability of NLPs during long term storage is a very important factor in developing a vaccine delivery platform suitable for widespread global use. When stored in a solution for extended periods of time, NLPs dissociate into their corresponding lipids and protein constituents, leading to particle degradation. Proper stabilization of NLPs can often be achieved by lyophilization (i.e. freeze-drying), a method widely used for various applications including pharmaceuticals. This process, however, can be damaging to particles without the presence of lyoprotectants or excipients that help maintain particle stability during lyophilization. Another method used to stabilize vaccines and pharmaceuticals is spray drying, a process that converts liquid formulations into dry powders through controlled heating and airflow. While spray drying is rapid, scalable, and cost-effective, lyophilization is typically a gentler process that better retains biomolecule structure and function. Both processes use excipients for particle stabilization, so lyophilization can be used as a surrogate to test stability of NLPs, to down-select formulations that may withstand the harsher conditions of spray drying. To screen different formulations, NLPs were synthesized and purified to homogeneity by size exclusion chromatography (SEC) and samples were prepared with a wide range of lyoprotectants and/or excipients. To assess the protective effects of excipients on NLPs upon spray drying, both pre- and post-lyophilized samples were analyzed by SEC. To assess the protective effects upon heating (encountered during the spray drying process), NLP samples were incubated at elevated temperatures prior to SEC analysis. The lyoprotectants and excipients evaluated in this study had different efficiencies in protecting NLPs during lyophilization and heating tests. Trehalose, for example, exhibits stabilization on NLPs both upon lyophilization and heating whereas leucine accelerated NLP dissociation. Although some lyoprotectants are effective by themselves, different combinations can decrease the stabilization of NLPs. Shelf-stable vaccines that do not require cold-chain storage are essential for global accessibility and our findings provide fundamental insight into how to advance NLP-based vaccines for these applications.

Serrano, Litzay J [Lawrence Livermore National Lab↗

Development of window scheduler algorithm exploiting natural ventilation and thermal mass for building energy simulation and smart home controls

Building energy simulations often rely on abstract assumptions when it comes to natural ventilation, such as ‘windows always open [or closed]’ or ‘windows open when outdoor temperature is below a certain threshold.’ However, simulations based on these assumptions fail to fully exploit the cooling potential of natural ventilation, as its effectiveness can be enhanced or diminished by various factors, including the presence of thermal mass. This issue also extends to smart home controls, where determining the window schedule becomes challenging without information about the building's response to outdoor conditions. To address these issues, this study has developed an analytical model for window operation schedules that leverages the passive cooling from natural ventilation. The analytical model was validated against a Modelica simulation. A case study utilizing the BESTEST model of ANSI/ASHRAE Standard 140 underwent validation with EnergyPlus simulations, showing strong concordance. The algorithm provides window schedule recommendations adapted to various airflow rates, thermal masses, and climate variations. Notably, the case study demonstrated that proper window scheduling could reduce indoor temperature by up to 8 °C under the given simulation settings, thereby improving resilience and indicating potential energy savings. Furthermore, the paper explores the potential opportunities and challenges this approach presents, especially for building simulation and smart home applications.

42 ENGINEERING↗

Experimental investigation of air-fuel equivalence ratio effects on advanced dual-fuel ammonia/diesel combustion on a single-cylinder medium-duty diesel engine at high load

Ammonia (NH 3 ) has garnered significant interest as an alternative fuel for meeting international emissions reduction mandates in sectors with high weight and distance requirements, such as shipping. Technical barriers and unanswered questions remain on the combustion strategies that can maximize ammonia utilization and minimize emissions. Prior research studies at the US Department of Energy’s Oak Ridge National Laboratory have shown strong performance with NH 3 under dual-fuel mode using conventional diesel combustion (CDC) manifold air pressure settings. Diesel airflow was initially used to simplify retrofitting (no turbocharger modification), which resulted in air-fuel equivalence ratios (λ) greater than 1.5. To characterize potential improvements in dual-fuel NH 3 combustion performance at richer in-cylinder conditions, a global λ sweep compared the use of early (E-pilot) and late (L-pilot) single diesel injections. The experiments were conducted at 1200 RPM and 12.8 ± 0.2 bar (75 % load), and λ was varied by decreasing the commanded air flow to the engine at greater than 90 % ammonia energy substitution level. A diesel injection timing sweep was conducted for both the injection strategies at fixed λ, and the timing with the lowest engine-out N 2 O emissions was identified. The results indicated an optimal balance between CO 2,eq and thermal efficiency benefits both E-pilot and l-pilot injection strategy cases compared with CDC at a λ of 1.4. In conclusion, the indicated nitrogen-based emissions exhibited a strong correlation to the ratio of CA5–50 and ignition delay for l-pilot, but no apparent trend emerged for the E-pilot injection strategy at the tested boundary conditions.

Ammonia↗

Close roof-mounted system temperature estimation for compliance to IEC TS 63126

When photovoltaic (PV) modules are installed on rooftops, the module temperature depends primarily on the geographic location and the mounting configuration. If the mounting structure does not provide sufficient airflow in a hot environment, the 98th percentile temperature will exceed 70°C, which according to IEC TS 63126 ED. 1, requires higher levels of thermal stability testing. However, there is no clear way to determine the temperature level needed for a particular location and system design. Here, in this work, we identify a relationship between the module standoff to the rooftop and the module temperature and propose methods to describe a minimum standoff for typical PV modules in a simple mounting configuration installed in a given location. For more complex system designs, we show how to determine an equivalent “effective standoff” that can be applied to generic calculations. Lastly, we show measurements and calculations from several systems to demonstrate how this method could work.

14 SOLAR ENERGY↗

A novel sub-pilot-scale direct-contact ultrasonic dehydration technology for sustainable production of distillers dried grains (DDG)

DDG is a major source of protein, calcium, phosphorus, and sulfur is arguably the most important byproduct of the bioethanol industry with increasing demand over the past few years. Reducing energy consumption in the DDG production process and energy recovery from DDG is vital for sustainable bioethanol productions. In this paper, a novel direct-contact multi-frequency, multimode, and modulated (MMM) ultrasonic dryer (US) was developed for the first time and has been applied in dehydration of wet distillers' grain (WDG). Ultrasonic drying (US) was combined with a convective airflow (HA) at different temperatures of 25 (room temperature), 50 and 70 °C to evaluate the impact of US, HA, and US + HA on drying kinetics, activation energy, chemical compositions, microstructure, and color of DDG. Semi-empirical kinetic models were developed and evaluating drying performances showed that the application of ultrasound significantly enhanced the drying rate and decreased the drying time (by 46%), especially at low drying temperatures. The activation energy for moisture removal in the presence of ultrasound was about 50% of that without ultrasound. The final dried distillers' grains product processed by ultrasonic drying had a brighter color, a higher available protein, a higher digestible protein (the lowest acid detergent insoluble crude protein), and a better surface profile with no compromise on minerals and fiber contents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Air Capture Using Aqueous Amino Acid Solvents in a Crossflow Absorber

Carbon dioxide (CO 2 ) is the most abundant of all greenhouse gases (GHGs). CO 2 levels in the atmosphere are 50% higher than in the preindustrial era, trapping heat. CO 2 removal from the atmosphere by direct air capture (DAC) is needed to achieve the internationally agreed global temperature goals. The most common CO 2 capture technology is absorption by aminebased solvents in packed columns. Amino acid solutions have recently gained attention due to their advantages over traditional amine solvents. To be implemented effectively, DAC industrial processes need to handle large airflow rates in separation absorbers. The large air and solvent flow rates preclude the use of countercurrent columns due to high-pressure drops and the occurrence of flooding. Crossflow air−liquid absorbers are used to handle large air and liquid volumes due to their lower-pressure drop. The objective of this work is to study the influence of crossflow absorber geometric parameters and operating conditions on product formation and process efficiency. An already derived theoretical model for countercurrent absorbers has been modified to simulate the operation of a crossflow DAC absorber. The predictive model was implemented into a computer code that was used to study the efficiency of the processes as geometric equipment dimensions and operating parameters vary. Practical suggestions are made to design more efficient DAC processes.

Absorption↗

Measured air quality impacts after teaching parents about cooking ventilation with a video: a pilot study

BackgroundCooking-related emissions contribute to air pollutants in the home and may influence children’s health outcomes.ObjectiveIn this pilot study, we investigate the effects of a cooking ventilation intervention in homes with gas stoves, including a video-based educational intervention and range hood replacement (when needed) in children’s homes.MethodsThis was a pilot (n = 14), before-after trial (clinicaltrials.gov #NCT04464720) in homes in the San Francisco Bay Area that had a school-aged child, a gas stove, and either a venting range hood or over-the-range microwave/hood. Cooking events, ventilation use, and indoor air pollution were measured in homes for 2–4 weeks, and children completed respiratory assessments. Midway, families received this intervention: (1) education about the hazards of cooking-related pollutants and benefits of both switching to back burners and using the range hood whenever cooking and (2) ensuring the range hood met airflow and sound performance standards. The educational intervention was delivered via a video developed in conjunction with local youth.ResultsWe found substantially increased use of back burners and slight increases in range hood use during cooking after intervening. Even though there was no change in cooking frequency or duration, these behavior changes resulted in decreases in nitrogen dioxide (NO2), including significant decreases in the total integrated concentration of NO2 over all cooking events from 1230 ppb*min (IQR 336, 7861) to 756 (IQR 84.0, 4210; p < 0.05) and NO2 collected on samplers over the entire pre- and post-intervention intervals from 10.4 ppb (IQR 3.5, 47.5) to 9.4 (IQR 3.0, 36.1; p < 0.005). There were smaller changes in PM2.5, and no changes were seen in respiratory outcomes.ImpactThis pilot before-after trial evaluated the use of a four-minute educational video to improve cooking ventilation in homes with gas stoves and one or more school-aged children. Participant behavior changed after watching the video, and there were decreases in indoor air pollutant concentrations in the home, some of which were significant. This brief video is now publicly available in English and Spanish (wspehsu.ucsf.edu/projects/indoor-air-quality), and this provides suggestive evidence of the utility of this simple intervention, which could be particularly beneficial for households that have children with asthma.

Holm, Stephanie M↗

Thermomagnetic generators for ultra-low-grade marine thermal energy harvesting

Low-grade thermal gradients in marine environments represent an underexploited energy source for autonomous sensing and monitoring. Converting such small temperature differences into usable electrical power remains a key challenge for ocean-deployed systems. We present a deployable thermomagnetic generator thoroughly characterized for marine-relevant energy harvesting. The device powers an internet-connected sensor and harvests ultra-low temperature differences akin to those at the ocean surface. It draws heat from water and rejects it to ambient air, operating optimally at a temperature difference (ΔT) of ~7.5 °C. Laboratory prototypes generated up to 6.7 mW at ΔT ~ 10 °C with gentle airflow (~1 m s -1 ). A separate controlled wave-tank demonstration validated stable operation and sensor powering under marine-like boundary conditions. Given its voltage and power margins, the generator could sustain multiple sensor nodes. Scalability and material assessments identify modular deployment and non-rare-earth alternatives as pathways toward practical marine energy harvesting and low-grade waste-heat recovery.

16 TIDAL AND WAVE POWER↗

Measurement and analysis of clothes dryer air leakage

Each year clothes dryer appliances are sold globally in the tens of millions. Both vented and ventless types are common and are heated by combustion, electric resistance, or electric heat pumps. In the dyer air path, segments can be defined between components such as the drum, blower, filter, screens or grills, and heat exchangers (where applicable). In this work, a technique was developed to experimentally measure air leakage into and from the segments of a clothes dryer. Detailed leakage measurements were taken on two vented and one ventless residential clothes dryer. The measurements were quantified as a leakage flow coefficient for each segment. For two dryers (one vented and one ventless), these flow coefficients were combined with in situ operating pressure measurements to determine leakage flow rates for each segment. For these two units under normal operation with air pressures within 0.5 kPa (50 mm water column) of ambient pressure, volumetric system air leakage was found to be about 20–60% of the blower airflow. Furthermore, a quasi–steady state psychrometric analysis was conducted on vented dryers with negatively pressurized drums. The analysis revealed that leakage quantity, location, and direction are essential to achieving an acceptable energy balance and accurate modeling results for a vented heat pump clothes dryer but are of limited significance for vented electric resistance clothes dryers.

42 ENGINEERING↗

Effect of air path heat losses at different locations in vapor compression-based clothes dryer: Quasi-steady modeling and design implications

Clothes drying is among the most power-intensive household end uses, and vapor compression-based clothes dryers offer substantial energy cost savings compared with conventional electric heater dryers. However, parasitic heat losses along the air path, that is, heat loss at the upstream of the drum, inside the drum, and at downstream of the drum, remain rarely quantified, but can strongly affect overall performance according to experiments. Here, this study enhances a vapor compression simulation model by integrating a validated drum model using a dimensionless heat-and-mass-transfer effectiveness correlation derived from 63 drying tests in the literature to form a quasi-steady dryer simulation model. The model is validated against laboratory measurements of a baseline dryer. The impact of heat losses is simulated at three locations and explored through 16 heat loss cases spanning two loads (2 and 5 kg), two airflow rates, and multiple loss distributions. For a 5 kg wet load, eliminating pre-drum and in-drum losses reduces total energy use by up to 34–35% and shortens drying time by 27–38% compared with the baseline. At a 2 kg wet load, introducing post-drum heat loss lowers energy costs by up to 23% and reduces operation time by up to 57% compared with the baseline. The results demonstrate that the impact of heat loss is location dependent. Vapor compression dryers should minimize pre-drum and in-drum losses while potentially exploiting post-drum heat dissipation to enhance the drying rate and energy cost savings.

Dryer↗

A computational analysis of effective R-values of buried ducts – the dynamic performance of buried ducts

Here, this paper evaluates the thermal performance of ducts partially or fully buried in loose-fill attic insulation. The overall thermal resistance between the ducts and the attic is referred to as an effective R-value. This paper shows a strong dependency of assumed attic temperature on the effective R-value. Based on the results, the effective R-value can be about twice as much with an attic temperature of 130 °F [54.4 °C], compared to when the attic temperature is 80 °F [26.7 °C]. Thus, this paper provides a polynomial regression equation based on a large set of simulations to determine the effective R-value of buried ducts depending on attic temperature and whether the HVAC system runs in cooling or heating mode. Further, the work presented in this paper investigated the potential impact of convective airflow within the attic insulation, particularly around the ducts. The analysis was based on computational fluid dynamics (CFD) and indicated that convectional forces are presented around the exterior surface of the ducts, but with negligible impact on the overall heat balance between the duct and the attic space.

97 MATHEMATICS AND COMPUTING↗

Experimental testing of additively manufactured embedded fiber optic smart devices for clean energy applications

Abstract An additively manufactured prototype smart device was created to investigate in-flow temperature distributions using embedded high-definition fiber optic sensors within a component for clean energy systems. The devices were created using Ultrasonic Additive Manufacturing to create a unique embedded pathway within a flow conditioner for the high-definition fiber optic sensors to be placed within. The fibers used allowed for temperature measurements to be taken every 0.65 mm along the fiber. The high-resolution fibers were thermally calibrated enable the 2D reconstruction of the temperature profile in the flow path of the structure. This is due to the temperature-related strain response of the material and strain measurements of the fibers. Hot airflow testing of these devices showed the ability to identify localized temperature differences in the flow. The observed strain response within the smart device had higher strain concentrations in the thicker web regions than in the thinner web regions. These higher strain regions resulted in higher uncertainties for the temperature responses. Further calibration is needed to improve the accuracy of the smart devices, specifically within the inner web structures of a flow straightening component. Further investigations of the devices within flow showed the temperature sensing to be independent of the effects of flow velocity. The devices were able to distinguish temperature differences within single and two-phase flow and showed local sensitivity to the temperature changes with the identification of hot and cold spots. The presented results showed the viability of the smart device for obtaining detailed temperature distributions using common industrial components. Eventually, the goal for these smart devices will be to withstand higher temperature and pressure environments such as those experienced in nuclear, fusion, and concentrated solar energy systems.

Donlan, Connor F. (ORCID:0000000223317882)↗