On the Alleviation of Background Noise for the High-Lift Common Research Model Aeroacoustic Test

Microphone array measurements of the airframe noise from the High-Lift Common Research Model (CRM-HL) in the NASA Langley 14- by 22- Foot Subsonic Tunnel were initially hindered by extraneous noise sources. The steps taken to reduce the background noise in the open-jet test section for the aeroacoustic test are described in this paper. Adhesive-backed felt was used to attenuate noise resulting from the interaction of the test section shear layer with the collector and diffuser surfaces, scrubbing noise from the floor perforated panels, as well as an extraneous noise source produced near the junction of the model and the floor when the model was producing significant lift. The effects of the felt on noise attenuation and acoustic reflections are discussed. Following the CRM-HL test, scrubbing noise measurements from a floor basket with a perforated top panel were acquired in the Quiet Flow Facility to compare the performance of different perforated panel covers and their respective effects on the noise spectra. Aside from a smooth, hard wall, the felt cover was found to produce the minimum scrubbing noise of all the materials tested.

background noise

Spinning mode sound propagation in ducts with acoustic treatment

Recent acoustic data show larger noise attenuations than predicted for acoustically treated aircraft engine inlets without splitter rings. A theoretical study of the acoustic propagation of spinning modes in acoustically treated open circular ducts is presented, and a suppressor with splitter rings was modeled by using the rectangular approximation to the annular duct. Theoretical models were used to determine optimum impedance and maximum attenuation for several spinning lobe numbers from 0 to 50. Results of the analysis indicate that for circular ducts the maximum possible attenuation and the optimum wall impedance are strong functions of the lobe number, and for annular ducts the attenuation and optimum wall impedance are insensitive to the spinning lobe number for well cut-on modes. These results explain why suppressors with splitter rings were quite effective in spite of the lack of detailed information on the noise source modal structure. Conversely, effective use of outer wall treatment alone will require expanded knowledge of the noise source structure. Approximate solutions are presented to help interpret the more exact theoretical results.

Rice, E. J.

The acoustics of aircraft engine-duct systems

Noise generated in aircraft engines is usually suppressed by acoustically treating the engine ducts. The optimization of this treatment requires an understanding of the transmission and attenuation of the acoustic waves. A critical review is presented of the state of the art regarding methods of determining the transmission and attenuation parameters and the effect on these parameters of (1) acoustic properties of liners, (2) the mean velocity, including uniform and shear profiles and nonparallel flow, (3) axial and transverse temperature gradients, (4) slowly and abruptly varying cross sections, and (5) finite-amplitude waves and nonlinear duct liners.

Nayfeh, A. H.

Spinning mode sound propagation in ducts with acoustic treatment

Recent acoustic data have shown larger noise attenuations than predicted for acoustically treated aircraft engine inlets without splitter rings. These data have stimulated a more detailed theoretical study of the acoustic propagation of spinning modes in acoustically treated open circular ducts. In addition, the suppressor with splitter rings was modeled by using the rectangular approximation to the annular duct. The theoretical models were used to determine optimum impedance and maximum attenuation for several spinning lobe numbers from 0 to 50. It is found that for circular ducts the maximum possible attenuation and the optimum wall impedance are strong functions of the lobe number. For annular ducts the attenuation and optimum wall impedance are insensitive to the spinning lobe number for well cut-on modes. The results help explain why suppressors with splitter rings have been quite effective in spite of the lack of detailed information on the noise-source modal structure. Conversely, effective use of outer-wall treatment alone will require expanded knowledge of the noise-source structure. Approximate solutions are presented to help interpret the more exact theoretical results.

Rice, E. J.

Experimental study of noise transmission into a general aviation aircraft

The effect of add-on treatments on noise transmission into a cabin of a light aircraft was studied under laboratory conditions for diffuse and localized noise inputs. Results indicate that stiffening skin panels with honeycomb would provide on the average 3dB to 7 dB insertion loss over the most of selected frequency range H1 to 1000 Hz. Addition of damping tape on top of the honeycomb treatment increases insertion loss by 2dB to 3dB. Porous acoustic blankets show no attenuation of transmitted noise for frequencies below 300 Hz. Insertion of impervious vinyl septa between the layers of porous acoustic blankets do not provide additional noise reduction for frequencies up to about 500 Hz. Similar behavior was observed for noise barriers composed of urethane elastomer, decoupler foam and acoustic foam. A treatment composed from several layers of acoustic foams does not increase noise attenuation for the entire frequency range studied. An acoustic treatment composed of honeycomb panels, constrained layer damping tape, 2 to 3 inches of porous acoustic blankets, and limptrim which is isolated from the vibrations of the main fuselage structure seems to provide the best option for noise control.

Vaicaitis, R.

Tuned optimization of extended reacting acoustic liners

A finite element Galerkin formulation was employed to study the optimum attenuation and reflection characteristics of acoustic waves propagating in tw0 dimensional straight ducts with extended reacting absorbing walls without a mean flow. The reflection and transmission of acoustic energy at the entrance and the exit of the duct were determined by coupling the finite element solutions in the absorbing portion of the duct to the eigenfunctions of an infinite, uniform, hard wall duct. In the frequency range where the duct height and acoustic wave length are nearly equal, power attenuation contours were examined to determine conditions for minimizing acoustic transmission through the duct. The extended reacting liners were found to significantly minimize the reflective characteristics of the duct rather than to increase absorption in the liner. Thus, extended reacting wall liner properties can be theoretically chosen to yield large impedance mismatches in an open straight duct.

Baumeister, Kenneth J.

Active minimization of energy density in three-dimensional enclosures

The objective of this study was to further investigate and develop a novel approach for actively controlling the sound field in enclosures that is based on the acoustic energy density. Typically the acoustic field in an enclosure has been controlled by minimizing the sum of the squared pressures from several microphones distributed throughout the enclosure. The approach investigated in this study involved minimizing the acoustic energy density at the sensor locations, rather than the squared pressure. Research previous to this study in a simple one-dimensional enclosure showed that improved global attenuation of the acoustic field is often obtained by minimizing the energy density, rather than the pressure. The current study built on the previous research by extending the method of controlling the acoustic energy density to three-dimensional enclosures. The study was intended to help establish if improved control can still be expected in a more general enclosure. The study was designed to be both analytical/numerical and experimental in nature.

Sommerfeldt, Scott D.

On the attenuation of sound by three-dimensionally segmented acoustic liners in a rectangular duct

Axial segmentation of acoustically absorbing liners in rectangular, circular or annual duct configurations is a very useful concept for obtaining higher noise attenuation with respect to the bandwidth of absorption as well as the maximum attenuation. As a consequence, advanced liner concepts are proposed which induce a modal energy transfer in both cross-sectional directions to further reduce the noise radiated from turbofan engines. However, these advanced liner concepts require three-dimensional geometries which are difficult to treat theoretically. A very simple three-dimensional problem is investigated analytically. The results show a strong dependence on the positioning of the liner for some incident source modes while the effect of three-dimensional segmentation appears to be negligible over the frequency range considered.

Koch, W.

Acoustic guide for noise-transmission testing of aircraft

Selective testing of aircraft or other vehicular components without requiring disassembly of the vehicle or components was accomplished by using a portable guide apparatus. The device consists of a broadband noise source, a guide to direct the acoustic energy, soft sealing insulation to seal the guide to the noise source and to the vehicle component, and noise measurement microphones, both outside the vehicle at the acoustic guide output and inside the vehicle to receive attenuated sound. By directing acoustic energy only to selected components of a vehicle via the acoustic guide, it is possible to test a specific component, such as a door or window, without picking up extraneous noise which may be transmitted to the vehicle interior through other components or structure. This effect is achieved because no acoustic energy strikes the vehicle exterior except at the selected component. Also, since the test component remains attached to the vehicle, component dynamics with vehicle frame are not altered.

Vaicaitis, Rimas

Progress on Acoustic Measurements of the Bulk Viscosity of Near-Critical Xenon (BVX)

We plan to determine the bulk viscosity of xenon 10 times closer [in reduced temperature tau = (T-Tc)/Tc] to its liquid-vapor critical point than ever before. (Tc is the critical temperature.) To do so, we must measure the dispersion and attenuation of sound at frequencies 1/100 of those used previously. In general, sound attenuation has contributions from the bulk viscosity acting throughout the volume of the xenon as well as contributions from the thermal conductivity and the shear viscosity acting within thin thermoacoustic boundary layers at the interface between the xenon and the solid walls of the resonator. Thus, we can determine the bulk viscosity only when the boundary layer attenuation is small and well understood. We present a comparison of calculations and measurements of sound attenuation in the acoustic boundary layer of xenon near its liquid-vapor critical point.

Gillis, Keith A.

My Internship at NASA

My name is Isaac Lopez and I am a junior at the University of Houston majoring in Mechanical Engineering Technology. I will be completing my first tour at the NASA-Johnson Space Center ("JSC") as a Mechanical Engineer within the Human Interfaces Branch. Throughout my tour, I was given the opportunity to work on multiple projects that have expanded my knowledge and interest in acoustics and engineering design. One of the projects I worked on at JSC consisted of doing acoustic simulation of the EVA comm. cap. While working on the comm. cap headset, my main duty consisted of simulating the acoustics of the headset to find a solution to the condensing water that can accumulate and block the acoustic tube, causing attenuation or complete loss of audio in one ear for an astronaut using the EVA. For this project, I had to create a Creo model of the comm. cap so that I would be able to import it into Comsol for acoustic simulation. I also had the opportunity to design a portable and lightweight beam degrader for the EEE Parts and Radiation team. With the help of Creo, I was able to make a CAD design and put together a small working prototype for the radiation team to demonstrate the capabilities that the beam degrader had. In addition to these projects, JSC allowed me to work closely on projects with other interns. I had the opportunity to help another intern with his acoustic diverter, intended to improve the sound quality in Node 1 of the ISS. During this project, I helped with some of the acoustic testing inside the anechoic chamber as well as helping record data during testing at the ISS mock up. During the course of my first tour, I was able to learn and continually improve on my CAD drafting skills. With each project I worked on, I acquired new ways to create and improve various designs with various constraints. Furthermore, I also had the opportunity to work with electrical engineers and learn about the electronic components that would provide control of the beam degrader functions. I was able to take the knowledge, skills and designs I had acquired during my tour at JSC (such as Finite Element Analysis) and apply them to my work on the Comsol Multiphysics software for acoustics simulation. I was also able to use it to do some stress analysis on a proposed design for a proposed Habitat structure. My time at JSC has been invaluable as it helped me grow and more fully-comprehend my major as well as spark an interest in acoustics and how much it relates to mechanical engineering. This internship has taught me that engineering is much more than a profession - it is embedded in our daily lives as a puzzle that requires critical thinking as an everyday challenge that makes life more interesting.

Lopez, Isaac

Noise radiation directivity from a wind-tunnel inlet with inlet vanes and duct wall linings

The acoustic radiation patterns from a 1/15th scale model of the Ames 80- by 120-Ft Wind Tunnel test section and inlet have been measured with a noise source installed in the test section. Data were acquired without airflow in the duct. Sound-absorbent inlet vanes oriented parallel to each other, or splayed with a variable incidence relative to the duct long axis, were evaluated along with duct wall linings. Results show that splayed vans tend to spread the sound to greater angles than those measured with the open inlet. Parallel vanes narrowed the high-frequency radiation pattern. Duct wall linings had a strong effect on acoustic directivity by attenuating wall reflections. Vane insertion loss was measured. Directivity results are compared with existing data from square ducts. Two prediction methods for duct radiation directivity are described: one is an empirical method based on the test data, and the other is a analytical method based on ray acoustics.

Soderman, P. T.

Active control of sound radiation from a vibrating rectangular panel by sound sources and vibration inputs - An experimental comparison

Active control of sound radiation from a rectangular panel by two different methods has been experimentally studied and compared. In the first method a single control force applied directly to the structure is used with a single error microphone located in the radiated acoustic field. Global attenuation of radiated sound was observed to occur by two main mechanisms. For 'on-resonance' excitation, the control force had the effect of increasing the total panel input impedance presented to the nosie source, thus reducing all radiated sound. For 'off-resonance' excitation, the control force tends not significantly to modify the panel total response amplitude but rather to restructure the relative phases of the modes leading to a more complex vibration pattern and a decrease in radiation efficiency. For acoustic control, the second method, the number of acoustic sources required for global reduction was seen to increase with panel modal order. The mechanism in this case was that the acoustic sources tended to create an inverse pressure distribution at the panel surface and thus 'unload' the panel by reducing the panel radiation impedance. In general, control by structural inputs appears more effective than control by acoustic sources for structurally radiated noise.

Fuller, C. R.

Assessment of Bulk Absorber Properties for Multi-Layer Perforates in Porous Honeycomb Liners

CONTINUING progress in materials technology provides potential for improved acoustic liners for attenuating broadband fan noise emissions from aircraft engine nacelles. Conventional liners (local-reacting perforate-over-honeycomb structures) provide significant narrow-band attenuation, but limited attenuation over wide bandwidths. Two approaches for increasing attenuation bandwidth are to (1) replace the honeycomb structure with bulk material, or (2) cascade multiple layers of perforate/honeycomb structures. Usage of the first approach is limited because of mechanical and maintenance reasons, while multi-layer liners are limited to about three layers because of their additional mechanical complexity, depth and weight. The current research concerns a novel approach reported by the University of Cincinnati, in which a single-layer conventional liner is converted into an extended-reaction, broadband absorber by making the honeycomb core structure porous. This modified single-layer liner requires no increase in depth and weight, and minimal increase in mechanical complexity. Langley has initiated research to identify potential benefits of liner structures with porous cell walls. This research has two complementary goals: (1) develop and validate experimental techniques for treating multi-layer perforates (representative of the internal cells of a liner with porous cell walls) as 1-D bulk materials, and (2) develop analytical approaches to validate this bulk material assumption. If successful, the resultant model can then be used to design optimized porous honeycomb liners. The feasibility of treating an N-layer perforate system (N porous plates separated by uniform air gaps) as a one-dimensional bulk absorber is assessed using the Two-Thickness Method (TTM), which is commonly used to educe bulk material intrinsic acoustic parameters. Tests are conducted with discrete tone and random noise sources, over an SPL range sufficient to determine the nonlinearity of the test specimens, for test specimens consisting of 5, 10 and 15% porous plates. Measured impedances for two liner thicknesses (e.g., 12 and 24 layers) are used as input to the TTM to determine the characteristic impedance and propagation constant that characterize these liners as bulk absorbers. These parameters are then used to calculate the predicted impedance of liners with different thicknesses (e.g., 36 layers), and a comparison of predicted and measured impedances for these other thicknesses is used to determine the efficacy of this approach. Finally, an independent method is used to educe the propagation constant for a single representative sample, and excellent comparison between the results for this method and those for the TTM provides increased confidence in the results achieved with the TTM. In general, the results demonstrate these multi-layer perforates can be acceptably treated as bulk absorbers.

Jones, Michael G.

Heating of the lower thermosphere by the dissipation of acoustic waves

Infrasound of 0.2 Hz known as microbaroms, generated by interfering ocean waves, propagates into the lower thermosphere where it is dissipated between 110 and 140 km. It is shown here that under average conditions in winter the energy input into this region is of the order of 0.33 W/kg, the same as that estimated for gravity wave dissipation, and capable of producing a heating of at least 30 K/day. To arrive at this result different dissipation mechanisms are discussed, with the calculated attenuation compared to previously published observations and observations of natural infrasound at Palisades, N.Y. Increased acoustic attenuation due to the presence of turbulence is not, in general, in evidence.

Rind, D.