Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABSORB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Automated Hybridization of X-ray Absorber Elements-A Path to Large Format Microcalorimeter Arrays

In the design of microcalorimeters, it is often desirable to produce the X-ray absorber separately from the detector element. In this case, the attachment of the absorber to the detector element with the required thermal and mechanical characteristics is a major challenge. In such arrays, the attachment has been done by hand. This process is not easily extended to the large format arrays required for future X- ray astronomy missions such as the New x-ray Telescope or NeXT. In this paper we present an automated process for attaching absorber tiles to the surface of a large-scale X-ray detector array. The absorbers are attached with stycast epoxy to a thermally isolating polymer structure made of SU-8. SU-8 is a negative epoxy based photo resist produced by Microchem. We describe the fabrication of the X-ray absorbers and their suspension on a handle die in an adhesive matrix. We describe the production process for the polymer isolators on the detector elements. We have developed a new process for the alignment, and simultaneous bonding of the absorber tiles to an entire detector array. This process uses equipment and techniques used in the flip-chip bonding industry and approaches developed in the fabrication of the XRS-2 instrument. XRS-2 was an X-ray spectrometer that was launched on the Suzaku telescope in July 10, 2005. We describe the process and show examples of sample arrays produced by this process. Arrays with up to 300 elements have been bonded. The present tests have used dummy absorbers made of Si. In future work, we will demonstrate bonding of HgTe absorbers.

Moseley, S.↗

The Peak Absorbance Wavelength of Photosynthetic Pigments Around Other Stars From Spectral Optimization

In the search for life on other planets, the presence of photosynthetic surface vegetation may be detectable from the colors of light it reflects, which on the modern Earth is a steep increase in reflectance between the red and near-infrared wavelengths, a “red edge.” This edge-like signature occurs at wavelengths of peak photon absorbance, which are the result of adaptations of the phototroph to their spectral environment. On planets orbiting different stellar types, red edge analogs may occur at other colors than red. Thus, knowing the wavelengths at which photosynthetic organisms preferentially absorb and reflect photons is necessary to detect red edge analogs on other planets. Using a numerical model that predicts the absorbance spectrum of extant photosynthetic pigments on Earth from Marosvolgyi & van Gorkom (2010), we calculate the absorbance spectrum for pigments on an Earth-like planet around F through late M type stars that are adapted for maximal energy production. In this model, cellular energy production is maximized when pigments are tuned to absorb at the wavelength that maximizes energy input from incident photons while minimizing energy losses due to thermal emission and building cellular photosynthetic apparatus. We find that peak photon absorption for photosynthetic organisms around F type stars tends to be in the blue while for G, K, and early M type stars, red or just beyond is preferred. Around the coolest M type stars, these organisms may preferentially absorb in the near-infrared, possibly past 1 micron. These predictions are consistent with previous, qualitative estimates of pigment absorptance. Our predicted absorbance spectra for photosynthetic surface organisms depend on both the stellar type and planetary atmospheric composition, especially atmospheric water vapor concentrations, which alter the availability of surface photons and thus the predicted pigment absorption. By constraining the absorbance spectra of alien, photosynthetic organisms, future observations may be better equipped to detect the weak spectral signal of red edge analogs.

astrobiology↗

Method of absorbance correction in a spectroscopic heating value sensor

A method and apparatus for absorbance correction in a spectroscopic heating value sensor in which a reference light intensity measurement is made on a non-absorbing reference fluid, a light intensity measurement is made on a sample fluid, and a measured light absorbance of the sample fluid is determined. A corrective light intensity measurement at a non-absorbing wavelength of the sample fluid is made on the sample fluid from which an absorbance correction factor is determined. The absorbance correction factor is then applied to the measured light absorbance of the sample fluid to arrive at a true or accurate absorbance for the sample fluid.

47 OTHER INSTRUMENTATION↗

Absorber for terahertz radiation management

A method and apparatus for minimizing the degradation of power in a free electron laser (FEL) generating terahertz (THz) radiation. The method includes inserting an absorber ring in the FEL beam path for absorbing any irregular THz radiation and thus minimizes the degradation of downstream optics and the resulting degradation of the FEL output power. The absorber ring includes an upstream side, a downstream side, and a plurality of wedges spaced radially around the absorber ring. The wedges form a scallop-like feature on the innermost edges of the absorber ring that acts as an apodizer, stopping diffractive focusing of the THz radiation that is not intercepted by the absorber. Spacing between the scallop-like features and the shape of the features approximates the Bartlett apodization function. The absorber ring provides a smooth intensity distribution, rather than one that is peaked on-center, thereby eliminating minor distortion downstream of the absorber.

43 PARTICLE ACCELERATORS↗

LBNF Hadron Absorber: Updated Mechanical Design and Analysis for 2.4 MW Operation

The Long-Baseline Neutrino Facility (LBNF) Hadron Absorber is located downstream of the decay pipe. It consists of actively cooled aluminum and steel blocks surrounded by steel and concrete shielding. Majority of the beam power is deposited in the absorber core which is water cooled. The surrounding steel and concrete shielding are air-cooled. The absorber provides radiation protection to personnel and keeps soil and ground activation levels below allowable limits. It is designed for 2.4 MW beam operations. The total heat load deposited into the absorber is approximately 400 kW. The current design considers the longer 4-interaction length target of the optimized beam design. In addition, the ‘bafflette’ around the target reduces the energy deposited into the absorber. For this reason, the sculpting in the aluminum core blocks, which was in the previous design, was removed, making the design uniform and less complicated. In addition, the uniformity of the absorber makes it easier to understand the muon monitor data. Steady state thermal, structural, and Computational Fluid Dynamics (CFD) analysis of critical absorber aluminum and steel components during steady state operations is discussed herein. A similar analysis for a 120 GeV, 10 μs pulse, accident condition is also discussed. A preliminary design for the accident pulse prevention system that protects the absorber is also described.

43 PARTICLE ACCELERATORS↗

Simultaneous removal of SO{sub 2} and NO by highly reactive absorbent containing calcium hypochlorite

Fly ash, industrial lime, and an additive (calcium hypochlorite )) were used to prepare a highly reactive absorbent. Simultaneous desulfurization and denitrification were carried out in a flue gas circulating fluidized bed (CFB). The effects of influencing factors on the removal efficiencies of SO{sub 2} and NO were also investigated. Removal efficiencies of 94.5% for SO{sub 2} and 65.5% for NO were obtained under the optimal experimental conditions. The component of the spent absorbent was analyzed with chemical analysis methods. The results indicated that more nitrogen than sulfur species appeared in the spent absorbent. A scanning electron microscope (SEM) and an accessory X-ray energy spectrometer (EDS) were used to observe the microproperties of the samples, including fly ash, highly reactive absorbent, and spent absorbent. The removal products of spent absorbent were analyzed using ion chromatography and chemical analysis. The simultaneous removal mechanism of SO{sub 2} and NO based on this absorbent was proposed according to the experimental results.

01 COAL, LIGNITE, AND PEAT↗

SU-E-T-516: Measurement of the Absorbed Dose Rate in Water Under Reference Conditions in a CyberKnife Unit

Purpose: This paper aims to measure the absorbed-dose-rate in a CyberKnife unit reference-field (6cm diameter) using three ionization chambers (IC) following the new IAEA/AAPM formalism and Gafchromic film (MD-V3-55 and EBT3) protocol according to our work reported previously. Methods: The absorbed-dose-rates were measured at 90cm and 70cm SSD in a 10cmx10cm field and at 70cm SSD in a 5.4cmx5.4cm equivalent to 6cm diameter field using a linac Varian iX. All measurements were performed at 10cm depth in water. The correction factors that account for the difference between the IC response on the reference field and the CyberKnife reference field, k-(Q-msr,Q)^(f-msr,f-ref), were evaluated and Gafchromic film were calibrated using the results obtained above. Under the CyberKnife reference conditions, the factors were used to measure the absorbed-dose-rate with IC according to the new formalism and the calibrated film was irradiated in water. The film calibration curve was used to evaluate the absorbed-dose-rate in the CyberKnife unit. Results: Difference up to 2.56% is observed between dose-rate measured with IC in the reference 10cmx10cm field, depending where the chamber was calibrated, which was not reflected in the correction factor k-(Q-msr,Q)^(f-msr,f-ref ) where variations of ~0.15%-0.5% were obtained. Within measurements uncertainties, maximum difference of 1.8% on the absorbed-dose-rate in the CyberKnife reference field is observed between all IC and the films Conclusion: Absorbed-dose-rate to water was measured in a CyberKnife reference field with acceptable accuracy (combined uncertainties ~1.32%-1.73%, k=1) using three IC and films. The MD-V3-55 film as well as the new IAEA/AAPM formalism can be considered as a suitable dosimetric method to measure absorbed-dose-rate to water in small and non-standard CyberKnife fields used in clinical treatments However, the EBT3 film is not appropriated due to the high uncertainty provided (combined uncertainty ~9%, k=1) This work is partially supported by Conacyt grant 127409 and PAPIITUNAM grant IN10581.

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-I-06: Y90 PET/CT for the Instantaneous Determination of Both Target and Non-Target Absorbed Doses Following Hepatic Radioembolization

Purpose The process of converting Yttrium-90 (Y90) PET/CT images into 3D absorbed dose maps will be explained. The simple methods presented will allow the medical physicst to analyze Y90 PET images following radioembolization and determine the absorbed dose to tumor, normal liver parenchyma and other areas of interest, without application of Monte-Carlo radiation transport or dose-point-kernel (DPK) convolution. Methods Absorbed dose can be computed from Y90 PET/CT images based on the premise that radioembolization is a permanent implant with a constant relative activity distribution after infusion. Many Y90 PET/CT publications have used DPK convolution to obtain 3D absorbed dose maps. However, this method requires specialized software limiting clinical utility. The Local Deposition method, an alternative to DPK convolution, can be used to obtain absorbed dose and requires no additional computer processing. Pixel values from regions of interest drawn on Y90 PET/CT images can be converted to absorbed dose (Gy) by multiplication with a scalar constant. Results There is evidence that suggests the Local Deposition method may actually be more accurate than DPK convolution and it has been successfully used in a recent Y90 PET/CT publication. We have analytically compared dose-volume-histograms (DVH) for phantom hot-spheres to determine the difference between the DPK and Local Deposition methods, as a function of PET scanner point-spread-function for Y90. We have found that for PET/CT systems with a FWHM greater than 3.0 mm when imaging Y90, the Local Deposition Method provides a more accurate representation of DVH, regardless of target size than DPK convolution. Conclusion Using the Local Deposition Method, post-radioembolization Y90 PET/CT images can be transformed into 3D absorbed dose maps of the liver. An interventional radiologist or a Medical Physicist can perform this transformation in a clinical setting, allowing for rapid prediction of treatment efficacy by comparison to published tumoricidal thresholds.

60 APPLIED LIFE SCIENCES↗

The Gd based Neutron Absorber for Spent Fuel Storage and Transport Cask - 17636

The criticality safety calculations were performed for integral model which has single rack wall of stainless steel added neutron absorber material. The integral model was verified by reference model composed of 3 layer; basket cell, neutron absorber and sheath. For the neutron absorber material, Gd was selected due to its high neutron absorption cross section in thermal region compared to B. The mathematical model based on validated code, KENO-Va in SCALE was used and the data library is ENDF/B-VII 238-Group. The k{sub eff} was calculated for changes in Gd and B contents in flooded condition. The Gd added stainless steel shows higher performance than B at same atomic percent and reactivity reduction decreases as absorber content increases. Therefore, the Gd 0.47 at% was selected for 'optimum Gd content' for effective use of neutron absorber. With Gd 0.47 at%, B, Sm, Er and Eu was considered for additional neutron absorber and B shows the best performance among them. The Gd 0.47 at% with B 2.05 at% was selected for (optimum neutron absorber content'. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Understanding ERE and iVOC Metrics for Graded CdSeTe Absorbers

PL-based external radiative efficiency (ERE) and implied open-circuit voltage (iVOC) metrics were introduced for thin-film solar absorbers to better understand the voltage deficit and diagnose losses in solar cells. Traditionally, elevated ERE and iVOC measurements are associated with diminished recombination within the solar device, a rationale heavily reliant on the assumption of a uniform bandgap and high carrier mobilities in the absorber. Recently, very low mobilities in CdSeTe absorbers (< 1 cm2/(V.s)) were measured using the light-induced transient grading technique. In this study, we use a detailed numerical model of iVOC to investigate the possible reasons of elevated iVOC in realistic CdSeTe absorbers with a graded Se profile. In particular, we examine how the bandgap nonuniformity and the reduced hole mobility in graded CdSeTe absorbers affect iVOC measurements. We show that high iVOC may result from inflated quasi-Fermi level splitting in the high-Se region in the front part of a CdSeTe absorber with slow hole transport. We reproduce the experimentally reported 360 mV increase in iVOC-VOC gap with reduced doping using a model with sub-1 cm2/(V.s) hole mobility in the high-Se region. Based on our results, we conclude that the iVOC metric (or ERE metric) should not be used as a sole metric of CdSeTe absorber quality. We discuss possible ways to extract useful information from the iVOC-VOC gap by supplementing the front-side illumination measurements with back-side illumination measurements.

14 SOLAR ENERGY↗

Optimal Design and Operation of Intensified Absorbers with 3D-Printed Packing for Solvent-Based CO 2 Capture

Many potential solvent-based carbon capture processes suffer from a high heat of absorption of CO 2 that adversely affects the thermodynamic driving force. While interstage coolers are often used for removing a portion of the generated heat by removing the solvent or a portion of the solvent from a stage and cooling and returning it back to the absorber, they can be placed only at discrete locations in the tower. This work investigates intensified absorbers with 3D-printed packing that includes an internal cooler and therefore can be potentially used for maximizing the operational efficiency of the absorbers for CO 2 capture. The intensified absorber is modeled by using a generic, first-principles, equation-oriented absorber column model. Since the placement of these intensified packings would cause a loss of area/volume used for mass transfer, optimization of the proposed intensified absorber is performed by optimally selecting the locations at which to place these devices and designing them such that the trade-off due to the addition of the heat removal area and the resulting loss in the mass transfer area is accounted for. Results show that optimally placed and designed intensified packings can lead to a significant increase in the capture efficiency of the process in comparison to a similar column with no internal cooling. It is also observed that by optimally placing and designing intensified packings, the lean solvent flow rate to the absorber can be decreased, and the CO 2 lean loading can be increased while still maintaining the same capture efficiency. These process changes can lead to a substantial reduction in the cost of capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Broad-band efficiency calibration of ITER bolometer prototypes using Pt absorbers on SiN membranes

The energy resolved efficiency of two bolometer detector prototypes for ITER with 4 channels each and absorber thicknesses of 4.5 μm and 12.5 μm, respectively, has been calibrated in a broad spectral range from 1.46 eV up to 25 keV. The calibration in the energy range above 3 eV was performed against previously calibrated silicon photodiodes using monochromatized synchrotron radiation provided by five different beamlines of Physikalische Technische Bundesanstalt at the electron storage rings BESSY II and Metrology Light Source in Berlin. For the measurements in the visible range, a setup was realised using monochromatized halogen lamp radiation and a calibrated laser power meter as reference. The measurements clearly demonstrate that the efficiency of the bolometer prototype detectors in the range from 50 eV up to ≈6 keV is close to unity; at a photon energy of 20 keV the bolometer with the thick absorber detects 80% of the photons, the one with the thin absorber about 50%. This indicates that the detectors will be well capable of measuring the plasma radiation expected from the standard ITER scenario. However, a minimum absorber thickness will be required for the high temperatures in the central plasma. At 11.56 keV, the sharp Pt-L{sub 3} absorption edge allowed to cross-check the absorber thickness by fitting the measured efficiency to the theoretically expected absorption of X-rays in a homogeneous Pt-layer. Furthermore, below 50 eV the efficiency first follows the losses due to reflectance expected for Pt, but below 10 eV it is reduced further by a factor of 2 for the thick absorber and a factor of 4 for the thin absorber. Most probably, the different histories in production, storage, and operation led to varying surface conditions and additional loss channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrathin triple-band polarization-insensitive wide-angle compact metamaterial absorber

In this study, the design, realization, and characterization of an ultrathin triple-band polarization-insensitive wide-angle metamaterial absorber are reported. The metamaterial absorber comprises a periodic array of modified six-fold symmetric snowflake-shaped resonators with strip spiral line load, which is printed on a dielectric substrate backed by a metal ground plane. It is shown that the absorber exhibits three distinct near-unity absorption peaks, which are distributed across C, X, Ku bands, respectively. Owing to the six-fold symmetry, the absorber is insensitive to the polarization of the incident radiation. In addition, the absorber shows excellent absorption performance over wide oblique incident angles for both transverse electric and transverse magnetic polarizations. Simulated surface current and field distributions at the three absorption peaks are demonstrated to understand the absorption mechanism. Particularly, the absorption modes come from the fundamental and high-order dipole resonances. Furthermore, the experimental verification of the designed absorber is conducted, and the measured results are in reasonable agreement with the simulated ones. The proposed ultrathin (∼0.018λ{sub 0}, λ{sub 0} corresponding to the lowest peak absorption frequency) compact (0.168λ{sub 0}×0.168λ{sub 0} corresponding to the area of a unit cell) absorber enables potential applications such as stealth technology, electromagnetic interference and spectrum identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE TWO-PHASE, TWO-VELOCITY IONIZED ABSORBER IN THE SEYFERT 1 GALAXY NGC 5548

We present an analysis of X-ray high-quality grating spectra of the Seyfert 1 galaxy NGC 5548 using archival Chandra-High Energy Transmission Grating Spectrometer and Low Energy Transmission Grating Spectrometer observations for a total exposure time of 800 ks. The continuum emission (between 0.2 keV and 8 keV) is well represented by a power law (GAMMA = 1.6) plus a blackbody component (kT = 0.1 keV). We find that the well-known X-ray warm absorber (WA) in this source consists of two different outflow velocity systems. One absorbing system has a velocity of -1110 +- 150 km s{sup -1} and the other of -490 +- 150 km s{sup -1}. Recognizing the presence of these kinematically distinct components allows each system to be fitted independently, each with two absorption components with different ionization levels. The high-velocity system consists of two components, one with a temperature of 2.7 +- 0.6 x 10{sup 6} K, log U = 1.23, and another with a temperature of 5.8 +- 1.0 x 10{sup 5} K, log U = 0.67. The high-velocity, high-ionization component produces absorption by charge states Fe XXI-XXIV, while the high-velocity, low-ionization component produces absorption by Ne IX-X, Fe XVII-XX, and O VII-VIII. The low-velocity system also required two absorbing components, one with a temperature of 5.8 +- 0.8 x 10{sup 5} K, log U = 0.67, producing absorption by Ne IX-X, Fe XVII-XX, and O VII-VIII, and the other with a lower temperature of 3.5 +- 0.35 x 10{sup 4} K and a lower ionization of log U = -0.49, producing absorption by O VI-VII and the Fe VII-XII M-shell Unresolved Transitions Array. Once these components are considered, the data do not require any further absorbers. In particular, a model consisting of a continuous radial range of ionization structures (as suggested by a previous analysis) is not required. The two absorbing components in each velocity system are in pressure equilibrium with each other. This suggests that each velocity system consists of a multi-phase medium. This is the first time that different outflow velocity systems have been modeled independently in the X-ray band for this source. The kinematic components and column densities found from the X-rays are in agreement with the main kinematic components found in the UV absorber. This supports the idea that the UV and X-ray absorbing gas is part of the same phenomenon. NGC 5548 can now be seen to fit in a pattern established for other WAs: two or three discrete phases in pressure equilibrium. There are no remaining cases of a well-studied WA in which a model consisting of a multi-phase medium is not viable.

79 ASTRONOMY AND ASTROPHYSICS↗

WARM GAS IN THE VIRGO CLUSTER. I. DISTRIBUTION OF Ly{alpha} ABSORBERS

The first systematic study of the warm gas (T = 10{sup 4-5} K) distribution across a galaxy cluster is presented using multiple background QSOs in and around the Virgo Cluster. We detect 25 Ly{alpha} absorbers (N{sub HI} = 10{sup 13.1-15.4} cm{sup -2}) in the Virgo velocity range toward 9 of 12 QSO sightlines observed with the Cosmic Origin Spectrograph, with a cluster impact parameter range of 0.36-1.65 Mpc (0.23-1.05 R{sub vir}). Including 18 Ly{alpha} absorbers previously detected by STIS or GHRS toward 7 of 11 background QSOs in and around the Virgo Cluster, we establish a sample of 43 absorbers toward a total of 23 background probes for studying the incidence of Ly{alpha} absorbers in and around the Virgo Cluster. With these absorbers, we find (1) warm gas is predominantly in the outskirts of the cluster and avoids the X-ray-detected hot intracluster medium (ICM). Also, Ly{alpha} absorption strength increases with cluster impact parameter. (2) Ly{alpha}-absorbing warm gas traces cold H I-emitting gas in the substructures of the Virgo Cluster. (3) Including the absorbers associated with the surrounding substructures, the warm gas covering fraction (100% for N{sub HI} > 10{sup 13.1} cm{sup -2}) is in agreement with cosmological simulations. We speculate that the observed warm gas is part of large-scale gas flows feeding the cluster both in the ICM and galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct absorbed dose to water determination based on water calorimetry in scanning proton beam delivery

Purpose: The aim of this manuscript is to describe the direct measurement of absolute absorbed dose to water in a scanned proton radiotherapy beam using a water calorimeter primary standard. Methods: The McGill water calorimeter, which has been validated in photon and electron beams as well as in HDR {sup 192}Ir brachytherapy, was used to measure the absorbed dose to water in double scattering and scanning proton irradiations. The measurements were made at the Massachusetts General Hospital proton radiotherapy facility. The correction factors in water calorimetry were numerically calculated and various parameters affecting their magnitude and uncertainty were studied. The absorbed dose to water was compared to that obtained using an Exradin T1 Chamber based on the IAEA TRS-398 protocol. Results: The overall 1-sigma uncertainty on absorbed dose to water amounts to 0.4% and 0.6% in scattered and scanned proton water calorimetry, respectively. This compares to an overall uncertainty of 1.9% for currently accepted IAEA TRS-398 reference absorbed dose measurement protocol. The absorbed dose from water calorimetry agrees with the results from TRS-398 well to within 1-sigma uncertainty. Conclusions: This work demonstrates that a primary absorbed dose standard based on water calorimetry is feasible in scattered and scanned proton beams.

60 APPLIED LIFE SCIENCES↗

SU-D-19A-02: Electron and Photon Absorbed Fractions for Tumors of Varying Sizes and Compositions

Purpose: To calculate absorbed fractions for mono-energetic photons and electrons in tumors of varying compositions using Monte Carlo simulations in MCNPX. Although tumor dosimetry has been previously investigated, these studies are very limited as they only consider absorbed fractions for soft-tissue tumors. Methods: The tumors were modeled as spheres with radii ranging from 0.10 cm to 6.0 cm and with compositions varying from 100% soft tissue to 100% bone. The energies of both the photons and electrons were varied from 10 keV to 10 MeV and were homogenously distributed throughout the tumor volume. Furthermore, this investigation addresses the issue of spherical versus elliptical tumors. Both prolate and oblate spheroid tumors of different compositions were modeled, and absorbed fractions were calculated for various electron and photon energies. Results: The data clearly shows an absorbed fraction dependence on tumor composition. For example, a soft-tissue model for a 3 MeV electron emitted in a 1 cm diameter bone tumor would have an 83% error, and this same assumption for a 500 keV photon would yield a 74% error. Ultimately, empirical fits were created for each of the five material compositions in order to facilitate the absorbed fraction calculation, requiring only the tumor size and particle energy. Furthermore, the data shows that absorbed fractions for moderate spheroids can be well approximated by spherical tumors of equal mass to within 8%, but in the extreme cases where the spheroid resembles more of a disk, the errors can be as high as 30%. Conclusion: This comprehensive data set is most valuable for nuclear medicine dosimetry because it incorporates particle type, particle energy, tumor size, and tumor composition. Although mono-energetic particles were modeled, absorbed fractions and S-values may be calculated for any radionuclide via linear interpolation, as long as the particle energies or spectra are known.

60 APPLIED LIFE SCIENCES↗

Preliminary Design of a New Pulsed-Neutron Die--Away Experiments with Absorbers (IER-552 CED-1)

This report presents the preliminary design (CED-1) of IER-552, pulsed-neutron die-away (PNDA) experiments with absorbers, to be conducted by Lawrence Livermore National Laboratory (LLNL). The goal of the PNDA experiments with absorbing materials is to produce high-quality, low-cost integral benchmarks that can be used to validate cross sections that are high priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). PNDA experiments can be used to generate nuclear data validation benchmarks quickly and cheaply, as they do not require fissile material or a nuclear facility to conduct them. The original PNDA experiments were set up at LLNL under IER-501. Extending the PNDA experiments to include absorbing materials leverages existing facilities and resources at LLNL to validate cross sections, with a basic experiment design that uses a neutron generator to impinge a short, mono-energetic neutron pulse on a poisoned, moderating target sample. The neutron pulse lasts 100 µs, after which the neutron population in the sample reaches thermal equilibrium and later spatial equilibrium. In this fully equilibrized state, the neutron population has a characteristic decay-time eigenvalue. The eigenvalue can be used as an integral parameter to validate nuclear data involved with neutron scattering and absorption. Two observables can be measured: the neutron population and the population of secondary γ-rays produced by inelastic and capture reactions. This report explores the feasibility of both approaches. For γ-ray measurements, this allows for direct measurement of reactions of interest for validation. During the neutron burst time, inelastic (prompt) γ-rays dominate, and these data can be isolated for validation of neutron inelastic scattering data. After the pulse ends, neutron capture (delayed) γ-rays dominate and are produced by many reaction channels as neutrons slow down to thermal energies. Two sets of γ-ray spectra (inelastic, capture) can be produced for validation. Additionally, the time-dependent decay of the capture γ-ray population when the neutron population is thermalized and in its fundamental mode can be used for validation. Two experiments can be imagined where pulsed neutrons are used to validate the nuclear data of absorbing materials. The first integrates well into the existing PNDA testbed at LLNL. The absorber material would be introduced into a moderating target and the same neutron generator, neutron detectors, electronics, and shielding box used for IER-501 would be employed. From the same experimental setup, many absorbing materials can be validated by simply changing the neutron poison in the moderator. The only significant modification would be the introduction of a γ-ray detector. Such an experiment would primarily serve to validate nuclear data in the thermal energy range. The second kind of experiment would validate the fast and epithermal energy range. It would involve pulsing neutron into a bare assembly of the absorber material and measuring the die-away of neutrons. The fast leakage of such an assembly requires nanosecond neutron-generator pulse widths and fast detectors/electronics that could measure ~200 ns die-away curves. This kind of experiment would ideally be performed at a cyclotron, like that available at Lawrence Berkeley National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗