Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “47 OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

3D-printed B 4 C collimation for neutron pressure cells

A design for an incident-beam collimator for the Paris–Edinburgh pressure cell is described here. This design can be fabricated from reaction-bonded B 4 C but also through fast turnaround, inexpensive 3D-printing. 3D-printing thereby also offers the opportunity of composite collimators whereby the tip closest to the sample can exhibit even better neutronic characteristics. Here, we characterize four such collimators: one from reaction-bonded B 4 C, one 3D-printed and fully infiltrated with cyanoacrylate, a glue, one with a glue-free tip, and one with a tip made from enriched 10 B 4 C. The collimators are evaluated on the Spallation Neutrons and Pressure Diffractometer of the Spallation Neutron Source and the Wide-Angle Neutron Diffractometer at the High Flux Isotope Reactor, both at Oak Ridge National Laboratory. This work clearly shows that 3D-printed collimators perform well and also that composite collimators improve performance even further. Beyond use in the Paris–Edinburgh cell, these findings also open new avenues for collimator designs as clearly more complex shapes are possible through 3D printing. An example of such is shown here with a collimator made for single-crystal samples measured inside a diamond anvil cell. These developments are expected to be highly advantageous for future experimentation in high pressure and other extreme environments and even for the design and deployment of new neutron scattering instruments.

47 OTHER INSTRUMENTATION↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

Broadband Fourier-Transform-Detected EPR at W-Band

This manuscript reports development of wideband Fourier transform (FT) electron paramagnetic resonance (EPR) detection capability at the uniquely high frequency of 94 GHz. Here, this technique is based on the HiPER spectrometer developed at the University of St. Andrews, into which we have integrated an arbitrary waveform generator (AWG) that is used to modulate the output from a solid-state multiplier chain prior to amplification, generating up to 1 kW microwave power with 1 GHz bandwidth. Benchmark experiments are presented for a standard TEMPOL radical, which comprises a 500 MHz broad EPR spectrum at 94 GHz. Using a single frequency-swept microwave pulse, efficient inversion of this spectrum is demonstrated, enabling frequency-dependent studies of the magnetization relaxation in the time-domain, again via broadband echo detection. From these measurements, an anisotropy in the spin–lattice relaxation time, T 1 , can be determined with ease for TEMPOL. In addition, we implement the FT detection scheme for multi-dimensional (electron–electron double resonance, or ELDOR) experiments, demonstrating the full capabilities of the HiPER spectrometer. As an example, we present FT-detected version of the ELDOR-detected nuclear magnetic resonance technique for the TEMPOL radical. We also describe potential applications of the new instrumentation for studies of gadolinium qubits.

36 MATERIALS SCIENCE↗

Instrument for in situ hard x-ray nanobeam characterization during epitaxial crystallization and materials transformations

Solid-phase epitaxy (SPE) and other three-dimensional epitaxial crystallization processes pose challenging structural and chemical characterization problems. The concentration of defects, the spatial distribution of elastic strain, and the chemical state of ions each vary with nanoscale characteristic length scales and depend sensitively on the gas environment and elastic boundary conditions during growth. The lateral or three-dimensional propagation of crystalline interfaces in SPE has nanoscale or submicrometer characteristic distances during typical crystallization times. Here, an in situ synchrotron hard x-ray instrument allows these features to be studied during deposition and crystallization using diffraction, resonant scattering, nanobeam and coherent diffraction imaging, and reflectivity. The instrument incorporates a compact deposition system allowing the use of short-working-distance x-ray focusing optics. Layers are deposited using radio-frequency magnetron sputtering and evaporation sources. The deposition system provides control of the gas atmosphere and sample temperature. The sample is positioned using a stable mechanical design to minimize vibration and drift and employs precise translation stages to enable nanobeam experiments. Results of in situ x-ray characterization of the amorphous thin film deposition process for a SrTiO 3 /BaTiO 3 multilayer illustrate implementation of this instrument.

47 OTHER INSTRUMENTATION↗

Aerosol Inlets for a Mid-Sized Uncrewed Aerial System (UAS)

The purpose of this technical report is to document the efforts to design and test two inlet systems for aerosol sampling suitable for deployment on a medium-sized fixed-wing Uncrewed Aerial System (UAS). This work, which was supported by the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility, was conducted at the Pacific Northwest National Laboratory (PNNL) for the ARM Aircraft Facility (AAF) starting in November 2017. The current work is a part of AAF efforts to instrument the ArcticShark (a mid-sized UAS owned and operated by the AAF) for atmospheric research and develop a scientific payload for deployment on a similar-sized UAS with minimal adaptation and integration. An aerosol inlet system is necessary to sample and transport ambient air sample to the scientific instrumentation with minimal distortions to the aerosols. Two isokinetic aerosol inlets were designed: the first is a simple passive system for a single instrument suitable to be installed in a wing pylon; the second is a system with active control designed to sample and distribute air among several heterogeneous instruments and to provide basic humidity control of the air sample so that the measured aerosol parameters should correspond to “dry” conditions (a common requirement). Both systems could be easily adapted for deployment on another platform and/or with a different set of instrumentation. Several conducted flight tests showed that the inlets’ performance met our design goals.

42 ENGINEERING↗

Simulating and benchmarking neutron total scattering instrumentation from inception of events to reduced and fitted data

In the design and realization of modern neutron scattering instrumentation, particularly when designing beamline concepts from the ground up, it is desirable to fully benchmark against realistically simulated data. This is especially true for total scattering beamlines, where the future deliverable data is to be analysed in both reciprocal- and real-space representations, and needs must be carefully balanced to ensure sufficient range, resolution and flux of the instrument. An approach to optimize the design of neutron scattering instrumentation via a workflow including ray-tracing simulations, event-based data reduction, heuristic analysis and fitting against realistically simulated spectra is demonstrated here. The case of the DISCOVER beamline concept at the Spallation Neutron Source is used as an example. The results of the calculations are benchmarked through simulation of existing instrumentation and subsequent direct comparison with measured data. Finally, on the basis of the validated models, the ability to explore design characteristics for future beamline concepts or future instrument improvements is demonstrated through the examples of detector tube size and detector layout.

47 OTHER INSTRUMENTATION↗

Software on Mars [Slides]

This community outreach presentation for high school students discusses instrumentation and software developed by Los Alamos National Laboratory for NASA's Perseverance rover that landed on Mars February 2021.

47 OTHER INSTRUMENTATION↗

Wind Energy Instrumentation Development Roadmap

The current instrumentation for observing the complex flow fields in and around wind plants struggles to match the fidelity of existing simulation tools. As a result, these measurement limitations create a hurdle for validating and assessing the quality of the wind plant numerical models. This roadmap for instrumentation development recommendations was created to offer guidance on narrowing the gap between measurement and simulation fidelity. A process was established to identify where gaps in instrumentation exist for wind energy test campaigns by analyzing the capabilities of instrumentation for capturing the various important phenomena at the necessary resolution for both the science goal and validation objectives. To this end, a multi-disciplinary team of experts on instrumentation, wind energy, and atmospheric science was assembled to identify these significant instrumentation needs. A recommendation for instrumentation to be developed is provided, and the framework developed through this process is expected to be useful to the design of future test campaigns. The mapping tools developed for this process will be distributed as part of a future International Energy Agency Wind Technology Collaboration Program task on instrumentation development.

17 WIND ENERGY↗

An automated multi-component gas adsorption system (MC GAS)

The knowledge gap on adsorption of complex mixtures in the literature relative to single component data represents a persistent obstacle to developing accurate process models for adsorption separations. The collection of mixed gas adsorption data is an imminent need for improved understanding of the behavior of adsorbent systems in these diverse adsorption applications. Current approaches to understanding mixture adsorption using predictive theories based on pure component adsorption experiments often fail to capture the behavior of more complex, non-ideal systems. In this work, we present an automated volumetric instrument for the measurement of mixed gas adsorption isotherms. This instrument was validated by comparison to other in-house instruments and data available in the literature, and the binary adsorption measurements were found to be thermodynamically consistent. The automation of this instrument allows for rapid collection of high-quality mixture adsorption data.

47 OTHER INSTRUMENTATION↗

A science-driven approach to optimize the design for a biological small-angle neutron scattering instrument

Biological small-angle neutron scattering (SANS) instruments facilitate critical analysis of the structure and dynamics of complex biological systems. However, with the growth of experimental demands and the advances in optical systems design, a new neutron optical concept is necessary to overcome the limitations of current instruments. This work presents an approach to include experimental objectives ( i.e. the science to be supported by a specific neutron scattering instrument) in the optimization of the neutron optical concept. The approach for a proposed SANS instrument at the Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory, USA, is presented here. Further, the instrument is simulated with the McStas software package. The optimization process is driven by an evolutionary algorithm using McStas output data, which are processed to calculate an objective function designed to quantify the expected performance of the simulated neutron optical configuration for the intended purpose. Each McStas simulation covers the complete instrument, from source to detector, including realistic sample scattering functions. This approach effectively navigates a high-dimensional parameter space that is otherwise intractable; it allows the design of next-generation SANS instruments to address specific scientific cases and has the potential to increase instrument performance compared with traditional design approaches.

47 OTHER INSTRUMENTATION↗

Effectiveness of Versalink 143 on Improving Shock Survival of Encapsulated Electronics

In the past, test-vehicle-mounted instrumentation modules that record sensor data during shock and vibration events have been coated with a polymer isolation layer to enhance survivability. This study uses finite element modeling to evaluate the effectiveness of the isolation material Versalink 143 on reducing stress in an instrumentation module. The modeling shows that while the isolation layer does attenuate stress due to high frequency shock and vibration, it also amplifies stress due to lower frequency shock and vibration. Thicker layers tend to attenuate high frequency stress more and amplify low frequency stress less. In addition, at higher test temperatures thermal expansion of the isolation layer can cause static stress in the module far greater than the stress due to shock, depending on how the module is constrained within the test vehicle. When designing and implementing vehicle- mounted instrumentation modules, the expected input shock spectrum, mounting constraints, and static effects of temperature must be carefully considered.

42 ENGINEERING↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy’s National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real- time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI’s Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: 1. Run in real-time on the edge (≥ 12 Hz) 2. Classification: Achieve less than 5% false positive detection 3. Classification: Achieve ≥ 95% methane plume detection rate 4. Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

AEcroscopy: A Software–Hardware Framework Empowering Microscopy Toward Automated and Autonomous Experimentation

Microscopy has been pivotal in improving the understanding of structure-function relationships at the nanoscale and is by now ubiquitous in most characterization labs. However, traditional microscopy operations are still limited largely by a human-centric click-and-go paradigm utilizing vendor-provided software, which limits the scope, utility, efficiency, effectiveness, and at times reproducibility of microscopy experiments. Here, in this work, a coupled software–hardware platform is developed that consists of a software package termed AEcroscopy (short for Automated Experiments in Microscopy), along with a field-programmable-gate-array device with LabView-built customized acquisition scripts, which overcome these limitations and provide the necessary abstractions toward full automation of microscopy platforms. The platform works across multiple vendor devices on scanning probe microscopes and electron microscopes. It enables customized scan trajectories, processing functions that can be triggered locally or remotely on processing servers, user-defined excitation waveforms, standardization of data models, and completely seamless operation through simple Python commands to enable a plethora of microscopy experiments to be performed in a reproducible, automated manner. This platform can be readily coupled with existing machine-learning libraries and simulations, to provide automated decision-making and active theory-experiment optimization to turn microscopes from characterization tools to instruments capable of autonomous model refinement and physics discovery.

47 OTHER INSTRUMENTATION↗

Instrument Control Software for Spectrophotometers

SRNL has developed instrument control software for diode array spectrophotometers that can be used for real time monitoring of dynamic systems. This software has evolved through several iterations as instruments have been developed for use in processing facilities at Savannah River Site. There are several noteworthy features of the software. The wavelength calibration is checked and updated in real time against reference emission lines that are designed into the instrument light source. Nonlinearities and offsets associated with the intensity response of the instruments are characterized, and absorbance spectra are appropriately corrected. These actions are necessary for accurate calculation of an absorbance spectrum from the intensity responses of two individual diode array detectors. The corrections also result in the spectra obtained for a particular sample by two (or more) different diode array detector pairs being nearly identical. This property assures consistent measurements at multiple locations with different instruments. It also permits the use of a single analyte calibration across many instruments without modification and without loss of accuracy

47 OTHER INSTRUMENTATION↗

Effect of Near-field Distribution on Transmission Characteristics of Fiber-fed Fabry–Perot Etalons

Fiber-fed etalons are widely employed in advanced interferometric instruments such as gravitational-wave detectors, ultrastable lasers and calibration reference for high-precision spectrographs. We demonstrate that variation in near-field distribution of the feeding fiber would deteriorate the spectrum precision of the fiber-fed Fabry–Perot etalon, especially when precision at the order of 3 × 10{sup -10} or higher is required. The octagonal fiber reinforced with double scrambler could greatly improve the steadiness and uniformness of the near-field distribution. When building wavelength calibrators for sub-m s{sup -1} precision radial-velocity instruments, the double scrambler should be considered meticulously.

47 OTHER INSTRUMENTATION↗

Velocity Profiling of a Gas–Solid Fluidized Bed Using Electrical Capacitance Volume Tomography

In this study, a method of producing velocity profile maps from electrical capacitance volume tomography (ECVT) measurements by reconstructing displacement from measured changes in capacitance is developed and applied to fluidized bed systems. The mapping of the reconstruction leverages the gradient of the sensitivity distribution of the ECVT sensor to circumvent the need for image cross correlation techniques. Experimental data of both bubbling and slugging fluidized beds are collected in a cold flow model. Adaptation of the technique is discussed in detail, and velocity profiles are obtained for a range of gas flow rates. The produced velocity maps are compared against the established methods of cross correlation and against empirical correlations from the literature and are found to agree well in tracking slug and bubble velocity. The exception is when the tracked object is large relative to the ECVT sensor dimensions, a scenario that can be avoided through proper sensor design. The quantities of average velocity, momentum, and solid and gas volume fraction are derived from the image and velocity profiles. The results demonstrate and extend the power of ECVT as a measurement tool for the study and monitoring of gas–solid fluidized beds by providing a computationally cheaper alternative to 3-D cross correlation for deriving velocity profiles.

47 OTHER INSTRUMENTATION↗

Reducing ion diffusion at atmospheric pressure through intermingled positive and negative ions

Increasing ion molecule reaction times for ambient ionization techniques can increase sensitivity of detection. Longer reaction times result in an increase in analyte signal relative to the reactant ion signal, however with a subsequent decrease in the total ion intensity. This loss in the total number of ions reaching the detector limits the extent to which increased reaction time can improve detection in practical applications. In this study ion loss was measured using either electric fields or gas flow to control ion transit time. Ion transit times ranged from 40 ms to 8s, which resulted in ion densities ranging from 5 x 10 6 to 2 x 10 4 ions/cm 3 , respectively. These results provide insights into practical reaction time limitations or experimental boundaries when exploring sensitivity enhancements in ambient ionization. When exploring longer reaction times with an atmospheric flow tube coupled to a mass spectrometer (AFT-MS), an additional corona discharge ionization source of the same polarity was added in an attempt to increase total ion signal, but no improvement in signal was observed. This observation suggested that there was a maximum ion density being reached by the corona discharge that could not be increased by adding more of the same polarity ions. A hypothesis was that intermingling both polarities of ions would reduce ion loss and increase the measured ion signal. When two corona discharge sources—one each of positive and negative polarity—were used simultaneously in an AFT-MS, the total ion signal of either polarity measured by the MS was approximately double the current from a single corona discharge source. An increase in the negative ion signal was also observed when ~10 parts-per-trillion vapor levels of an explosive (RDX) were introduced. In this case both the nitrate reactant ions and the RDX signal more than doubled with the addition of a corona discharge source producing positive ions. When intermingling positive and negative ions, an increase in ion current was also observed when the AFT was coupled directly to a Faraday detector or to an ion mobility spectrometer. This was the first demonstration of interfacing the AFT to an IMS. The observations and developments from this work will help in creating more portable instruments with improved sensitivity for detection of chemicals.

47 OTHER INSTRUMENTATION↗