Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind resource”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Voices from Rural Electric Cooperatives: A Call for a DER Integration Playbook for Rural and Agricultural Income & Savings from Renewable Energy (RAISE)

Rural-serving electric utilities (RSEUs)—including electric cooperatives, municipal systems, and small investor-owned utilities—are essential players in the evolving energy landscape. These community-focused entities are increasingly being asked to consider distributed energy resources (DERs) such as rooftop and ground-mounted solar, wind, battery storage, smart water heaters, and demand response programs (NRECA 2025; Lenhart et al. 2020). Yet the path to DER adoption is far from straightforward in the rural context. This report is based on in-depth interviews with managers of rural electric cooperatives across the United States. These conversations offer a grounded, unvarnished look at how DERs are perceived, what barriers exist, and what conditions might enable integration and adoption. While the utilities interviewed vary in geography, size, and DER experience, several clear and common themes emerged across electric cooperatives such that the report recommends the development of a DER Integration Runbook to help utilities assess readiness, define local use cases, engage stakeholders, pilot projects, and iterate, expanding over time.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluating the Potential for Tidal Phase Diversity to Produce Smoother Power Profiles

Although tidal energy conversion technologies are not yet commercially available or cost-competitive with other renewable energy technologies like wind turbines and solar panels, tides are a highly predictable resource. Tidal energy’s predictability indicates that the resource could introduce less volatility into balancing the electric grid when compared to other renewables, a fundamentally desirable attribute for the electric system. More specifically, tidal energy resources are unique in that they have the potential to produce relatively smoother power profiles over time through aggregation. In order to generate smooth power profiles from tidal resources, sufficient complexity within the timing of tides is necessary within electrical proximity. This study evaluates the concept of aggregating diverse tides for the purpose of reducing periods of no and low energy production and creating smoother power profiles in regions around Alaska and Washington by calculating cross-correlations of tidal current velocity time series. Ultimately, study results show limited potential to exploit the resources for this purpose and describe the institutional mechanisms necessary to realize the benefits in practice.

16 TIDAL AND WAVE POWER↗

Conversion Kinetics and Ionic Conductivity in Na-β”-Alumina + YSZ (Naβ”AY) Sodium Solid Electrolyte via Vapor Phase Conversion Process

Sodium ion batteries have been receiving increasing attention and may see potential revival in the near future, particularly in large-scale grid energy storage coupling with wind and solar power generation, due to the abundant sodium resources, low cost, and sufficiently high energy density. Among the known sodium ion conductors, the Na-β”-alumina electrolyte remains highly attractive because of its high ionic conductivity. This study focuses on the vapor phase synthesis of a Na-β”-Alumina + YSZ (Naβ”AY) composite sodium electrolyte, which has higher mechanical strength and stability than conventional single phase β”-Alumina. The objectives are the measurement of conversion kinetics through a newly developed weight-gain based model and the determination of sodium ionic conductivity in the composite electrolyte. Starting samples contained ~70 vol% α-Alumina and ~30 vol% YSZ (3 mol% Y 2 O 3 stabilized Zirconia) with and without a thin alumina surface layer made by sintering in air at 1600 °C. The sintered samples were placed in a powder of Na-β”-alumina and heat-treated at 1250 °C for various periods. Sample dimensions and weight were measured as a function of heat treatment time. The conversion of α-Alumina in the α-Alumina + YSZ composite into Naβ”AY occurred by coupled diffusion of sodium ions through Na-β”-alumina and of oxygen ions through YSZ, effectively diffusing Na2O. From the analysis of the time dependence of sample mass and dimensions, the effective diffusion coefficient of Na 2 O through the sample, D eff , was estimated to be 1.74 x 10 -7 cm2 s -1 , and the effective interface transfer parameter, k eff , was estimated as 2.33 x 10 -6 cm s -1 . By depositing a thin alumina coating layer on top of the bulk composite, the chemical diffusion coefficient of oxygen through single phase Na-β”-alumina was estimated as 4.35 x 10 -10 cm 2 s -1 . An AC impedance measurement was performed on a fully converted Naβ”AY composite, and the conductivity of the composite electrolyte was 1.3 x 10 -1 S cm -1 at 300 °C and 1.6 x 10 -3 S cm -1 at 25 °C, indicating promising applications in solid state or molten salt batteries at low to intermediate temperatures.

36 MATERIALS SCIENCE↗

Lunar Resources

This slide presentation reviews the lunar resources that we know are available for human use while exploration of the moon. Some of the lunar resources that are available for use are minerals, sunlight, solar wind, water and water ice, rocks and regolith. The locations for some of the lunar resouces and temperatures are reviewed. The Lunar CRater Observation and Sensing Satellite (LCROSS) mission, and its findings are reviewed. There is also discussion about water retention in Permament Shadowed Regions of the Moon. There is also discussion about the Rock types on the lunar surface. There is also discussion of the lunar regolith, the type and the usages that we can have from it.

Edmunson, Jennifer↗

Representation of the Solar Capacity Value in the ReEDS Capacity Expansion Model: Preprint

An important emerging issue is the estimation of renewables' contributions to reliably meeting system demand, or their capacity value. While the capacity value of thermal generation can be estimated easily, assessment of wind and solar requires a more nuanced approach due to resource variability. Reliability-based methods, particularly, effective load-carrying capacity (ELCC), are considered to be the most robust techniques for addressing this resource variability. The Regional Energy Deployment System (ReEDS) capacity expansion model and other long-term electricity capacity planning models require an approach to estimating CV for generalized PV and system configurations with low computational and data requirements. In this paper we validate treatment of solar photovoltaic (PV) capacity value by ReEDS capacity expansion model by comparing model results to literature for a range of energy penetration levels. Results from the ReEDS model are found to compare well with both comparisons--despite not being resolved at an hourly scale.

14 SOLAR ENERGY↗

Five Indisputable Facts on Modern Power Systems

This presentation overviews five indisputable facts about modern power systems: Fact one: The grid can handle more renewable generation than previously thought. Fact two: Geographic and resource diversity provide additional reliability to the system. Fact three: Wind and solar forecasting provide significant value. Fact four: Our electric power markets were not originally designed for variable renewables -- but they could be adapted. Fact five: Modern power electronics are creating new sources of essential reliability services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Turkey opens electricity markets as demand grows

Turkey's growing power market has attracted investors and project developers for over a decade, yet their plans have been dashed by unexpected political or financial crises or, worse, obstructed by a lengthy bureaucratic approval process. Now, with a more transparent retail electricity market, government regulators and investors are bullish on Turkey. Is Turkey ready to turn the power on? This report closely examine Turkey's plans to create a power infrastructure capable of providing the reliable electricity supplies necessary for sustained economic growth. It was compiled with on-the-ground research and extensive interview with key industrial and political figures. Today, hard coal and lignite account for 21% of Turkey's electricity generation and gas-fired plants account for 50%. The Alfin Elbistan-B lignite-fired plant has attracted criticism for its lack of desulfurization units and ash dam facilities that have tarnished the industry's image. A 1,100 MW hard-coal fired plant using supercritical technology is under construction. 9 figs., 1 tab.

20 FOSSIL-FUELED POWER PLANTS↗

Identifying Potential Sub-Synchronous Oscillations Using Impedance Scan Approach: Preprint

This paper presents an impedance scan study on the real-world power system in Australia that has observed 17 to 20 Hz intermittent subsynchronous oscillations. Through the impedance scan of each of the IBRs, both individually and collectively, potential resonance modes are identified. The impedance scans were carried out using electromagnetic transient PSCAD models of the network. The network comprises of site-specific, black-boxed models of IBRs supplied by the generators. The impedance scan approach was divided in three major steps: (1) the first step is to identify IBRs where impedance analysis needs to be performed based on the magnitude of oscillations observed at their points of interconnection (POIs); (2) the second step focuses on performing impedance scans at selected IBRs in single-machine infinite-bus (SMIB) configuration to identify internal resonance modes of an IBR and to evaluate if any of these modes become unstable under certain grid conditions; (3) the third step performs impedance scans at a few selected IBRs while connected to the wider network model to obtain the impedance response of both the IBR and the grid - this step evaluates control interactions among IBRs. The impedance scan study found that a few IBRs have an underdamped resonance mode at around 17 Hz, which becomes unstable under a certain operating condition. Another interesting finding was that certain IBRs increase the effective grid impedance seen by another IBR in proximity for a particular operating condition. Under this operating condition, the resulting subsynchronous oscillation mode is more pronounced due to a combination of control interactions among IBRs through the transmission network under study and a resonance mode inside the IBRs.

control interactions↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

Automated Boundary Conditions for Wind Tunnel Simulations

Computational fluid dynamic (CFD) simulations of models tested in wind tunnels require a high level of fidelity and accuracy particularly for the purposes of CFD validation efforts. Considerable effort is required to ensure the proper characterization of both the physical geometry of the wind tunnel and recreating the correct flow conditions inside the wind tunnel. The typical trial-and-error effort used for determining the boundary condition values for a particular tunnel configuration are time and computer resource intensive. This paper describes a method for calculating and updating the back pressure boundary condition in wind tunnel simulations by using a proportional-integral-derivative controller. The controller methodology and equations are discussed, and simulations using the controller to set a tunnel Mach number in the NASA Langley 14- by 22-Foot Subsonic Tunnel are demonstrated.

Carlson, Jan-Renee↗

Renewable Resource Handbook for Feasibility Studies at Selected Air Force Bases

This Handbook outlines and describes each of these renewable technologies and provides general information about each resource. The AF site-specific FS reports provide similar information, but only for resources that exist at each site. Therefore, this Handbook is primarily for installation personnel to understand more about resources and technologies that were determined to have no potential for development at their location. It also provides a single reference for general information on all renewable energy resources.

09 BIOMASS FUELS↗

Energy 101 - Wind [Slides]

The Energy 101: Wind presentation, developed for the Energy Technology Innovation Partnership Project (ETIPP), provides an overview of wind energy. It covers fundamental concepts, technologies, considerations, case studies, and additional resources.

17 WIND ENERGY↗

Water demand for electricity in deep decarbonisation scenarios: a multi-model assessment

This study assesses the effects of deep electricity decarbonisation and shifts in the choice of power plant cooling technologies on global electricity water demand, using a suite of five integrated assessment models. We find that electricity sector decarbonisation results in co-benefits for water resources primarily due to the phase-out of water-intensive coal-based thermoelectric power generation, although these co-benefits vary substantially across decarbonisation scenarios. Wind and solar photovoltaic power represent a win-win option for both climate and water resources, but further expansion of nuclear or fossil- and biomass-fuelled power plants with carbon capture and storage may result in increased pressures on the water environment. Further to these results, the paper provides insights on the most crucial factors of uncertainty with regards to future estimates of water demand. These estimates varied substantially across models in scenarios where the effects of decarbonisation on the electricity mix were less clear-cut. Future thermal and water efficiency improvements of power generation technologies and demand-side energy efficiency improvements were also identified to be important factors of uncertainty. We conclude that in order to ensure positive effects of decarbonisation on water resources, climate policy should be combined with technology-specific energy and/or water policies.

BIOENERGY↗

Significance of Dynamic and Transient Analysis in the Design and Operation of Hybrid Energy Systems

Energy systems were historically designed and operated with a specific energy conversion objective, while managing loads and resources. In the recent years, the increased utilization of non-dispatchable renewable sources such as wind and solar has played a role in power quality and the reliability of power systems. In order to mitigate the risk associated with the non-dispatchable resources an integrated approach, such as Hybrid Energy Systems (HES), has to be taken, integrating the loads and resource management between the traditional thermal power plants and the non-dispatchable resources. As our electric energy becomes more diverse in its generation resources, the HES with its operational control system, its real-time view and its dynamic decisions making will become an essential part of the integrated energy systems and improve the overall grid reliability. The operational constraints of the energy sources on both the thermal power plants and the non-dispatchable resources in HES, plays a vital role in the planning and design stage. It is an established fact that the choice of energy source depends on the available natural resources and possible infrastructure. A critical component of decision-making depends on the complementary nature and controllability of the energy sources to supply the load demands with high reliability. Controllability of complex HES to achieve desired performance and flexibility is implemented via coordinated control systems while simultaneously generating electricity and other useful products such as useful heat or hydrogen. These systems are based on instrumentation, signal processing, control theory, and engineering system design. The entire HES along with the control systems are characterized by widely varying time constants. Hence, for a well-coordinated control and operation, we propose physics based modeling of the subsystems to assist in a dynamic and transient analysis. Dynamic and transient analysis in real and non-real time domain of the potential sources is capable of providing satisfactory results at the feasibility analysis stage. A simplified HES consisting of complementary energy sources is used to demonstrate the proposed approach. Suitable real time simulations to perform dynamic and transient analysis will be performed to verify results from the non-real time analysis. The role of such analyses, especially the real time dynamic and transient analysis for manual controls is elaborated. It is also discussed that faster than real time simulation will pave the future for controller rooms and hence manual control procedures. Multiple tools such as Real Time Simulator, Matlab®, Simulink®, PSCAD®, MOOSE, etc. are expected to be used for the HES analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demand Response Resources for Energy and Ancillary Services (Presentation)

Demand response (DR) resources present a potentially important source of grid flexibility particularly on future systems with high penetrations of variable wind an solar power generation. However, DR in grid models is limited by data availability and modeling complexity. This presentation focuses on the co-optimization of DR resources to provide energy and ancillary services in a production cost model of the Colorado test system. We assume each DR resource can provide energy services by either shedding load or shifting its use between different times, as well as operating

14 SOLAR ENERGY↗

10MW Class Direct Drive HTS Wind Turbine: Cooperative Research and Development Final Report, CRADA Number CRD-08-00312

This paper summarizes the work completed under the CRADA between NREL and American Superconductor (AMSC). The CRADA combined NREL and AMSC resources to benchmark high temperature superconducting direct drive (HTSDD) generator technology by integrating the technologies into a conceptual wind turbine design, and comparing the design to geared drive and permanent magnet direct drive (PMDD) windturbine configurations. Analysis was accomplished by upgrading the NREL Wind Turbine Design Cost and Scaling Model to represent geared and PMDD turbines at machine ratings up to 10 MW and then comparing cost and mass figures of AMSC's HTSDD wind turbine designs to theoretical geared and PMDD turbine designs at 3.1, 6, and 10 MW sizes.

17 WIND ENERGY↗

Solar, Wind, and Load Forecasting Dataset for MISO, NYISO, and SPP Balancing Areas

The Performance-based Energy Resource Feedback, Optimization, and Risk Management (PERFORM) program is an initiative intended to foster "a fundamental shift in grid management rooted in an understanding of asset risk and system risk" (ARPA-E 2020). Launched by the Advanced Research Projects Agency-Energy (ARPA-E), the program supports efforts to incorporate uncertainty in electric power decision making. In support of PERFORM, the National Renewable Energy Laboratory (NREL) has produced a set of time-coincident forecasts of solar, wind, and load profiles. As part of Phase I of the PERFORM effort, NREL created a dataset that consists of one year of time-coincident load, wind, and solar actuals and probabilistic forecasts based on data from the Electric Reliability Council of Texas (ERCOT) (Bryce et al. 2023). In Phase II, NREL developed similar datasets for three other U.S. Independent System Operators (ISO): the Midcontinent Independent System Operator (MISO), the New York Independent System Operator (NYISO), and the Southwest Power Pool (SPP).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Marginal Soils Index Analysis & Geospatial Data

This data package contains output files associated with the Mongird et al. paper entitled "Can US power grid expansion avoid prime agricultural lands?" and is organized into four dataset directories. Each dataset is described in more detail below. 1. Marginal Soils Index Analysis Description: This folder contains a csv file with land needs and availability by state, power generating technology type, and scenario in 2050 when suitable siting areas are additionally constrained to areas with increasing levels of soil marginality. Files: msi_constrained_siting_availability_2050.csv Variables: Scenario - Projected 2050 scenario name State - US state abbreviation Technology - Generating technology type solar = solar photovoltaic gas_cc_re = natural gas combined cycle (recirculating cooling) wind = onshore wind gas_cc_ccs_re = natural gas combined cycle with carbon capture sequestration (recirculating cooling) gas_cc_dry = natural gas combined cycle with (dry cooling) gas_cc_pond = natural gas combined cycle with (pond cooling) coal_conv_ccs_re = conventional coal with carbon capture sequestration (recirculating cooling) Req_Capacity_MW - The amount of rated capacity required in 2050 of the given technology type in the given state and under the given scenario from the capacity expansion plan Req_Capacity_Factor - The assumed capacity factor (fraction between 0 and 1) for the given technology type in the given state and under the given scenario by the capacity expansion plan Req_Land_km2 - The amount of land required (in km-squared) to host the required generating capacity that is capable of meeting the specified capacity factor for the given technology type in the given state and under the given scenario Req_Energy_TWh - Product of Req_Capacity_MW, Req_Capacity_Factor, and 8760/1e6 for the given technology type in the given state and under the given scenario MSI_Case - The level of MSI that siting the given technology is additionally constrained to, where >0 means siting is additionally constrained to suitable land areas that have an MSI value greater than 0 >=1 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 1 >=2 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 2 >=3 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 3 Soil Attribute Rasters Description: This folder contains geospatial raster files for individual soil parameters upscaled to the listed grid resolution (30m or 1 km). 1 km resolution files are a spatial average of non-missing 30m resolution values. All raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. Files: avg_cond_raster_ .tif - Average conductivity of the saturation extract across all soil horizons within a depth of 40 inches, measured in mmhos/cm max_cond_raster_ .tif - Maximum conductivity of the saturation extract across all soil horizons within a depth of 40 inches, measured in mmhos/cm min_ph_raster_ .tif- Min pH values across all soil horizons within a depth of 40 inches. avg_ph_raster_ .tif - Average pH value across all soil horizons within a depth of 40 inches. max_ph_raster_ .tif- Max pH value across all soil horizons within a depth of 40 inches. erosion_factor_raster_ .tif - Product of k-factor and percent slope flood_freq_raster_ .tif - Number of months of the year during which the area is commonly, frequently, or very frequently flooded. max_sar_raster_ .tif - Maximum sodium adsorption ratio across all horizons within a depth of 40 inches rock_frac_raster_ .tif - Fraction of the upper 6 inches of soil composed of rock fragments larger than 3 inches. temp_regime_raster_ .tif - Soil temperature regime with the following key: 0 = pergelic 1 = gelic 2 = cryic 3 = frigid 4 = isofrigid 5 = mesic 6 = isomesic 7 = thermic 8 = isothermic 9 = hyperthermic 10 =isohyperthermic Marginal Soils Index Rasters Description: This folder contains geospatial raster files of the Marginal Soils Index at the listed grid resolution (30m or 1 km). 1 km resolution files are a spatial average of 30m resolution. Both raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. A value of 0 indicates that there were no soil attributes present that indicate marginal soil. NA values indicate that data was unavailable or bodies of water. Files: marginal_soils_index_30m_raster.tif marginal_soils_index_1km_raster.tif Marginal Soils Index Resource Potential Rasters Description: This folder contains geospatial raster files of the Marginal Soils Index + Resource Potential (MSIxRP) score at 1km resolution for geothermal, solar, and wind technologies. Raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. NA values indicate that the location is not suitable for siting the given technology due to policy, environmental, socioeconomic, topological, and other constraints regardless of soil marginality level. Areas with values greater than or equal to zero represent the product of the normalized MSI value and the normalized resource potential value. Files: geothermal_msi_rp_score_raster.tif solar_msi_rp_score_raster.tif wind_msi_rp_score_raster.tif Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Agriculture↗