Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Thermal protection system ablation sensor

An isotherm sensor tracks space vehicle temperatures by a thermal protection system (TPS) material during vehicle re-entry as a function of time, and surface recession through calibration, calculation, analysis and exposed surface modeling. Sensor design includes: two resistive conductors, wound around a tube, with a first end of each conductor connected to a constant current source, and second ends electrically insulated from each other by a selected material that becomes an electrically conductive char at higher temperatures to thereby complete an electrical circuit. The sensor conductors become shorter as ablation proceeds and reduced resistance in the completed electrical circuit (proportional to conductor length) is continually monitored, using measured end-to-end voltage change or current in the circuit. Thermocouple and/or piezoelectric measurements provide consistency checks on local temperatures.

Gorbunov, Sergey↗

Thermal Evaluation of Fiber Bragg Gratings at Extreme Temperatures

The development of integrated fiber optic sensors for use in aerospace health monitoring systems demands that the sensors be able to perform in extreme environments. In order to use fiber optic sensors effectively in an extreme environment one must have a thorough understanding of the sensor's capabilities, limitations, and performance under extreme environmental conditions. This paper reports on our current sensor evaluation examining the performance of freestanding fiber Bragg gratings (FBG) at extreme temperatures. While the ability of FBGs to survive at extreme temperatures has been established, their performance and long term survivability is not well documented. At extreme temperatures the grating structure would be expected to dissipate, degrading the sensors performance and eventually ceasing to return a detectable signal. The fiber jacket will dissipate leaving a brittle, unprotected fiber. For FBGs to be used in aerospace systems their performance and limitations need to be thoroughly understood at extreme temperatures. As the limits of the FBGs performance are pushed the long term survivability and performance of the sensor comes into question. We will not only examine the ability of FBGs to survive extreme temperatures but also look at their performance during many thermal cycles. This paper reports on test results of the performance of thermal cycling commercially available FBGs, at temperatures up to 1000 C, seen in aerospace applications. Additionally this paper will report on the performance of commercially available FBGs held at 1000 C for hundreds of hours. Throughout the evaluation process, various parameters of the FBGs performance were monitored and recorded. Several test samples were subjected to identical test conditions to allow for statistical analysis of the data. Test procedures, calibrations, referencing techniques, performance data, and interpretations and explanations of results are presented in the paper along with directions for future research.

Juergens, Jeffrey↗

All-digital Sensor System for Distributed Downhole Pressure Monitoring in Unconventional Fields

This project developed and validated (through field tests) a new low-cost all-digital pressure sensing technology for in situ distributed downhole pressure monitoring in unconventional oil and gas (UOG) fields. The all-digital sensing technology uses a built-in non-electric analog-to-digital converter (ADC) to transform the pressure information into a combination of binary (ON/OFF) states. As such, the system does not need downhole electronics for signal conditioning and telemetry. The all-digital sensors can be remotely logged over a long distance, and many sensors can be multiplexed for distributed sensing. Based on a review of unconventional wells in the Lower 48 states, the specification of the sensor is to measure pressure up to 69 MPa (10,000 psi) and temperature up to 250°C. A sensor with a helical bourdon sensing element and a digital signal decoder of 50 mm diameter and 109 mm length was constructed. The helical bourdon sensing element was made of 304L stainless steel and filled with motor oil. The digital converter was made up of 8 digital reading pads constructed of high-temperature epoxy with conductive inserts made of stainless steel. The sensor had a linear response to pressure with an accuracy of 0.14 MPa (20 psi). To withstand the high pressure, the sensor was enclosed in a stainless-steel pressure housing with a wall thickness of 5.5 mm, a diameter of 73 mm, and a length of 724 mm. In the laboratory tests, the sensor exhibited no temperature-related effects on the results. The sensor did not show drift over a 14-day test period at elevated pressure. A field test was conducted where the sensor was deployed in a test wellbore at the Quest drilling test facility to a depth of 0 feet over three weeks. The sensor was attached to the production rods, along with a downhole reference sensor of PPS27 type, which is a permanent downhole monitoring system. During the testing phase, the test well annular blow-out preventer was closed, and the well was pressurized at the surface to 11 MPa (1600 psi). The sensor read the elevated bottom hole pressure of 1500 psi. A multiplexing unit was created for the sensor to deploy multiple sensors on one data transmission line in a distributed approach. The multiplexing unit was tested in a simulated environment of 3048 m (10,000 ft) with five sensors distributed. The sensors were pressurized at different intervals. The multiplexed sensors recorded the correct pressure, and the multiplexing did not interfere with the readings. The proposed concept of an all-digital pressure sensor for harsh downhole environments was designed, manufactured, and tested in the laboratory and tested at the field to a up to 69 MPa and 250°C. This technology has high-temperature tolerance and has potential in downhole areas outside oil and gas, such as carbon capture and storage (CCS) and geothermal wells. The sensor concept has been proven in this project, but to create a commercially viable product, manufacturing a sensor with a smaller diameter needs to be performed.

02 PETROLEUM↗

High Temperature Testing with Sapphire Fiber White-Light Michelson Interferometers

In the design of new aerospace materials, developmental testing is conducted to characterize the behavior of the material under severe environmental conditions of high stress, temperature, and vibration. But to test these materials under extreme conditions requires sensors that can perform in harsh environments. Current sensors can only monitor high temperature test samples using long throw instrumentation, but this is inherently less accurate than a surface mounted sensor, and provides no means for fabrication process monitoring. A promising alternative is the use of sapphire optical fiber sensors. Sapphire is an incredibly rugged material, being extremely hard (9 mhos), chemically inert, and having a melting temperature (over 2000 C). Additionally, there is a extensive background of optical fiber sensors upon which to draw for sapphire sensor configurations.

Barnes, A.↗

Detection and Monitoring of Stratigraphic Markers and Temperature Trends at the Greenland Ice Sheet Project 2 Using Passive-Microwave Remote-Sensing Data

Satellite passive-microwave sensors provide a sensitive means of studying ice-sheet surface processes that assists ice-core interpretation and can extend local observations across regional scales. Analysis of special sensor microwave/imager (SSM/I) brightness temperature (TB) data supports ice-core research in two specific ways. First, the summer hoar complex layers used to date the Holocene portion of the Greenland Ice Sheet Project 2 ice core can be defined temporally and spatially by SSM/I 37-GHz vertically (V) and horizontally (H) polarized B ratio (V/H) trends. Second, comparison of automatic weather station temperatures to SSM/I 37-GHz V TB data shows that they are an effective proxy temperature record in this region. Also, the TB data can be correlated with proxy temperature trends from stable-isotope-ratio (delta O-18 and delta-D) profiles from snow pits and this allows the assignment of dates to specific snow depths.

Shuman, C. A.↗

Broadband IR Measurements for Modis Validation

The primary objective of this research was the development and deployment of autonomous shipboard systems for infrared measurement of ocean surface skin temperature (SST). The focus was on demonstrating long-term, all-weather capability and supplying calibrated skin SST to the MODIS Ocean Science Team (MOCEAN). A secondary objective was to investigate and account for environmental factors that affect in situ measurements of SST for validation of satellite products. We developed and extensively deployed the Calibrated, InfraRed, In situ Measurement System, or CIRIMS, for at-sea validation of satellite-derived SST. The design goals included autonomous operation at sea for up to 6 months and an accuracy of +/- 0.1 C. We used commercially available infrared pyrometers and a precision blackbody housed in a temperature-controlled enclosure. The sensors are calibrated at regular interval using a cylindro-cone target immersed in a temperature-controlled water bath, which allows the calibration points to follow the ocean surface temperature. An upward-looking pyrometer measures sky radiance in order to correct for the non-unity emissivity of water, which can introduce an error of up to 0.5 C. One of the most challenging aspects of the design was protection against the marine environment. A wide range of design strategies to provide accurate, all-weather measurements were investigated. The CIRIMS uses an infrared transparent window to completely protect the sensor and calibration blackbody from the marine environment. In order to evaluate the performance of this approach, the design incorporates the ability to make measurements with and without the window in the optical path.

Jessup, Andrew T.↗

Two-stage gas measurement system

A quick-response, real-time gaseous measurement system allows for the continuous sampling of a low pressure gaseous environment. A sample of test gas from the low pressure gaseous environment is continuously extracted and pumped to a structural tee joint which is open to the atmosphere at one end to maintain the test gas at a constant pressure. The structural tee joint communicates at the other end with a heater for maintaining the test gas at a constant temperature. From the heater, the test gas is sent to a sensor which develops a voltage that is proportional to the partial pressure of the gaseous component to be measured in the test gas, a constant flow rate of test gas being provided through the heater and sensor. Since test gas pressure, temperature, and flow rate are being held constant, changes in sensor voltage are attributable only to changes in the concentration of the measured gas component.

Sprinkle, Danny R.↗

Multiplexable high-temperature stable and low-loss intrinsic Fabry-Perot in-fiber sensors through nanograting engineering

This paper presents a method of using femtosecond laser inscribed nanograting as low-loss– and high-temperature–stable in-fiber reflectors. By introducing a pair of nanograting inside the core of a single-mode optical fiber, an intrinsic Fabry-Perot interferometer can be created for high-temperature sensing applications. The morphology of the nanograting inscribed in fiber cores was engineered by tuning the fabrication conditions to achieve a high fringe visibility of 0.49 and low insertion loss of 0.002 dB per sensor. Using a white light interferometry demodulation algorithm, we demonstrate the temperature sensitivity, cross-talk, and spatial multiplexability of sensor arrays. Both the sensor performance and stability were studied from room temperature to 1000°C with cyclic heating and cooling. Our results demonstrate a femtosecond direct laser writing technique capable of producing highly multiplexable in-fiber intrinsic Fabry-Perot interferometer sensor devices with high fringe contrast, high sensitivity, and low-loss for application in harsh environmental conditions.

Wang, Mohan (ORCID:0000000166784993)↗

Temperature or pressure controller

Silicon chip thermal sensor coupled into a solid state power source controls temperature or pressure in combustion research. The silicon chip sensing element is embedded in a ceramic support for insulation, and connected to a high resistance bridge which operates the solid state power amplifiers.

Gillett, J. D.↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aerosol jet printed 3 omega sensors for thermal conductivity measurement

The 3 omega (3ω) method is a trusted technique for measuring thermal conductivity—a fundamental material property of critical importance in a broad range of applications. However, traditional 3ω sensor processing requires some form of physical vapor deposition, such as metal evaporation or sputtering. These 3ω sensor deposition techniques limit the materials and sample sizes applicable to the 3ω method. This work demonstrates an aerosol jet printing method to directly print silver 3ω sensors that yield accurate temperature-dependent measurement up to 300 °C on materials with thermal conductivity ranging from 1 to 150 W/m K. The interrelationship between printed sensor geometry, sensor thermal stability, and applicability to the 3ω method is examined. Thermal conductivity measurement with 3ω sensors conventionally sintered at 300 °C agrees to independent laser flash measurement within 4% from room temperature to 150 °C. An unconventional rapid high-temperature sintering method is shown to produce sensors that agree within 3% of the laser flash measurements from room temperature to 300 °C. The rapid sintering profiles also reduced the sensor–substrate thermal boundary resistance of the printed sensors by as much as 88%. The direct printing of 3ω sensors creates opportunities for measurement of thermal transport properties in applications previously inapplicable to the 3ω method.

47 OTHER INSTRUMENTATION↗

Conceptual Design of Neutron Sensor Qualification Device

The Advanced Sensors and Instrumentation Program at Idaho National Laboratory has been formulating strategies to qualify sensors for use in nuclear environments, particularly in irradiation experiments and advanced reactors. When qualifying neutron sensors for use in high-temperature environments, the wide range of neutron flux levels and representative energy spectra presents significant challenges. This paper discusses the development of the Neutron Sensor Qualification Device (NQD), which is designed to test neutron sensors in high temperature controlled environments with known neutron spectra, addressing the spatial and spectral complexities of neutron fluxes in reactor cores. The proposed NQD will be situated in the exposure room at the Armed Forces Radiobiology Research Institute, thus affording a unique capability to expose sensors to high neutron and gamma fluxes. To achieve thermal control, the device will utilize a radiation-hardened tube furnace, accommodating multiple sensors and neutron activation dosimetry wires. Titanium, iron, and cobalt dosimeter wires are chosen from the American Society for Testing and Materials and International Reactor Dosimetry and Fusion File libraries as references for providing energy-dependent fluence measurements. The design ensures precise sensor positioning to minimize mutual shielding and flux perturbation, which are evaluated via Monte Carlo N particle Transport Code (MCNP) simulations. These simulations have informed the development of guidelines on sensor placement within the NQD. The NQD is essential to the qualification of neutron sensors for advanced reactor technologies. It enables controlled testing of a statistically significant number of sensors, thereby supporting assessments of sensor performance across various neutron flux levels and temperatures. This paper highlights the detailed planning for the NQD prototype, along with its inaugural irradiation (scheduled for fiscal year [FY] 2025). The results from this initial testing will be fundamental in evaluating the device’s performance and establishing measurement uncertainty for in-pile neutron sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of A Multi-Spectral Pyrometry Sensor for High-Speed Transient Surface-Temperature Measurements in Combustion-Relevant Harsh Environments

Accurate and high-speed transient surface-temperature measurements of combustion devices including internal combustion (IC) engines, gas turbines, etc., provide validation targets and boundary conditions for computational fluid dynamics models, and are broadly relevant to technology advancements such as performance improvement and emissions reduction. Development and demonstration of a multi-infrared-channel pyrometry-based optical instrument for high-speed surface-temperature measurement is described. The measurement principle is based on multi-spectral radiation thermometry (MRT) and uses surface thermal radiation at four discrete spectral regions and a corresponding emissivity model to obtain surface temperature via non-linear least squares (NLLS) optimization. Rules of thumb for specifying the spectral regions and considerations to avoid interference with common combustion products are developed; the impact of these along with linear and non-linear MRT analysis are assessed as a function of temperature and signal-to-noise ratio. A multi-start method to determine the MRT-solution global optimum is described and demonstrated. The resulting multi-channel transient pyrometry instrument is described along with practical considerations including optical-alignment drift, matching intra-channel transient response, and solution-confidence indicators. The instrument demonstrated excellent >97% accuracy and >99% 2-sigma precision over the 400–800 °C range, with ~20 µs (50 kHz, equivalent to 0.2 cad at 2000 RPM IC-engine operation) transient response in the bench validation.

47 OTHER INSTRUMENTATION↗

Cryogenic Selective Surfaces

There are many challenges involved in deep-space exploration, but several of these can be mitigated, or even solved, by the development of a coating that can reject most of the Sun's energy and yet still provide some far-infrared heat emission. Such a coating would allow non-heat-generating objects in space to reach cryogenic temperatures without using an active cooling system. This would be a benefit to deep-space sensors that require low temperatures, such as the James Webb Telescope focal plane array. It would also allow the use of superconductors in deep space, which could lead to magnetic energy storage rings, lossless power delivery, or perhaps a large-volume magnetic shield against galactic cosmic radiation. But perhaps the most significant enablement achieved from such a coating would be the long-term storage in deep space of cryogenic liquids, such as liquid oxygen (LOX).In this report, we review the state of the art in low-temperature coatings and calculate the lowest temperatures each of these can achieve, demonstrating that cryogenic temperatures cannot be reached in deep space in this fashion. We then propose a new coating that does allow coated objects in deep space to achieve the very low temperatures required to store liquid oxygen or nitrogen. These new coatings consist of a moderately thick scattering layer (typically 5 mm) composed of a material transparent to most of the solar spectrum. This layer acts as a scatterer to the Sun's light, performing the same process as titanium dioxide in white paint in the visible. Under that layer, we place a metallic reflector, e.g. silver, to reflect long-wave radiation that is not well scattered. The result is a coating we call "Solar White," in that it scatters most of the solar spectrum just as white paint does for the visible. Our modeling of these coatings has shown that temperatures as low as 50 K can be reached for a coated object fully exposed to sunlight at 1 AU from the Sun and far from the Earth.In the second half of the report we explore a mission application of this coating in order to show that it allows LOX to be carried on a mission to Mars. Heat can reach a LOX tank in five ways: direct radiation from the Sun, scattered or reflected radiation from the Sun off of spacecraft components, radiation from nearby planets or the Moon, radiation from the infrared emission of other parts of the spacecraft, and conduction along support struts and flow lines. We discuss these and sum their total contribution when using a Solar White coating to demonstrate an architecture that allows the transportation of LOX to Mars. After this, other applications of Solar White are listed.

Cryogenic Materials↗

Surface Acoustic Wave H2 and O2 Sensors Based on Conducting Metal Oxides/Langasite for Elevated Temperature Applications - presentation

<p style="text-align: justify;"><span style="font-family: Arial; font-size: 10pt;">• </span><span style="color: black; font-family: Arial; font-size: 10pt;">SAW reflective delay line devices were designed and successfully fabricated on Langasite by patterning platinum electrodes.</span><p style="text-align: justify;"><span style="font-family: Arial; font-size: 10pt;">• </span><span style="color: black; font-family: Arial; font-size: 10pt;">Fabricated devices successfully tested up to 500°C for temperature sensing applications.</span><p style="text-align: justify;"><span style="font-family: Arial; font-size: 10pt;">• </span><span style="color: black; font-family: Arial; font-size: 10pt;">Indium oxide (IO) and indium tin oxide (ITO) sensing layers were developed on the SAW devices using sputtering and sol-gel method.</span><p style="text-align: justify;"><span style="font-family: Arial; font-size: 10pt;">• </span><span style="color: black; font-family: Arial; font-size: 10pt;">IO- and ITO-functionalized langasite SAW reflective delay line devices were used for sensing H2 and O2 at 350°C. </span><br>

Mao, Elizabeth↗