Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

A Revised Exoplanet Yield from the Transiting Exoplanet Survey Satellite (TESS)

The Transiting Exoplanet Survey Satellite (TESS) has a goal of detecting small planets orbiting stars bright enough for mass determination via ground-based radial velocity observations. Here, we present estimates of how many exoplanets the TESS mission will detect, the physical properties of the detected planets, and the properties of the stars that those planets orbit. This work uses stars drawn from the TESS Input Catalog Candidate Target List and revises yields from prior studies that were based on Galactic models. We modeled the TESS observing strategy to select approximately 200,000 stars at 2-minute cadence, while the remaining stars are observed at 30-minute cadence in full-frame image data. We placed zero or more planets in orbit around each star, with physical properties following measured exoplanet occurrence rates, and used the TESS noise model to predict the derived properties of the detected exoplanets. In the TESS 2-minute cadence mode we estimate that TESS will find 1250 ± 70 exoplanets (90% confidence), including 250 smaller than 2 R(sub ⊕). Furthermore, we predict that an additional 3100 planets will be found in full-frame image data orbiting bright dwarf stars and more than 10,000 around fainter stars. We predict that TESS will find 500 planets orbiting M dwarfs, but the majority of planets will orbit stars larger than the Sun. Our simulated sample of planets contains hundreds of small planets amenable to radial velocity follow-up, potentially more than tripling the number of planets smaller than 4 R(sub ⊕) with mass measurements. This sample of simulated planets is available for use in planning follow-up observations and analyses.

Barclay, Thomas↗

SHERLOC Investigations at the Máaz and Séítah formations within Jezero crater

Introduction: The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument combines microscopic imaging, native fluorescence and Raman spectroscopy to better understand the mineral and chemical makeup of rocks on the martian surface. Native fluorescence emissions from aromatic organic species allow for detection and classification of aromatic organic molecules, whereas Raman scattered photons from molecules allow identification of functional groups of organics, chemicals, and minerals. These signatures are obtained on a 100 micron spatial scale and collocated to images so textures, minerals and chemicals can all be compared [1]. Results: SHERLOC has been operating on Mars since February 18, 2021. As of this writing, we have analyzed 3 natural surfaces, and 5 abraded rock patches created during the Crater Floor Campaign within Jezero crater [2]. The Guillaumes target (from the Roubion outcrop, Roubion member of the Máaz Formation) is dominated by Ca-sulfate with patches of perchlorate. The Bellegarde target (from the Rochette outcrop, Rochette member of the Máaz Formation) exhibits Raman peaks that match hydrated Ca-sulfate, amorphous/microcrystalline silicate (AMS), carbonate, and phosphate phases. A fluorescence doublet at ~305 and ~325 nm was detected and is most likely due to indigenous organic material in the sample. The Garde target (from the Bastide outcrop, Bastide member of the Séítah Formation) is dominated by olivine and carbonate with AMS occurring across the material. The Dourbes target (from the Brac outcrop, Bastide member of the Séítah Formation) is dominated by olivine and shows minor amounts of carbonate, hydrated Ca-sulfate, and AMS. The Quartier target exhibits a large sulfate feature, as well as carbonate, perchlorate, olivine and a fluorescence doublet at 305 and 325 nm and is very similar to that observed at Bellegarde. In each of these samples we have identified fluorescence features that are likely aromatic organics native to the rock interiors. Acknowledgments: This work was carried out at the Jet Propulsion Laboratory, The California Institute of Technology under a contract from NASA.

L W Beegle↗

Tissue-mimicking phantoms for performance evaluation of photoacoustic microscopy systems

Phantom-based performance test methods are critically needed to support development and clinical translation of emerging photoacoustic microscopy (PAM) devices. While phantoms have been recently developed for macroscopic photoacoustic imaging systems, there is an unmet need for well-characterized tissue-mimicking materials (TMMs) and phantoms suitable for evaluating PAM systems. Our objective was to develop and characterize a suitable dermis-mimicking TMM based on polyacrylamide hydrogels and demonstrate its utility for constructing image quality phantoms. TMM formulations were optically characterized over 400–1100 nm using integrating sphere spectrophotometry and acoustically characterized using a pulse through-transmission method over 8–24 MHz with highly confident extrapolation throughout the usable band of the PAM system. This TMM was used to construct a spatial resolution phantom containing gold nanoparticle point targets and a penetration depth phantom containing slanted tungsten filaments and blood-filled tubes. These phantoms were used to characterize performance of a custom-built PAM system. The TMM was found to be broadly tunable and specific formulations were identified to mimic human dermis at an optical wavelength of 570 nm and acoustic frequencies of 10–50 MHz. Imaging results showed that tungsten filaments yielded 1.1–4.2 times greater apparent maximum imaging depth than blood-filled tubes, which may overestimate real-world performance for vascular imaging applications. Nanoparticles were detectable only to depths of 120–200 µm, which may be due to the relatively weaker absorption of single nanoparticles vs. larger targets containing high concentration of hemoglobin. The developed TMMs and phantoms are useful tools to support PAM device characterization and optimization, streamline regulatory decision-making, and accelerate clinical translation.

Hsu, Hsun-Chia↗

TPSAS-NF1676L-11435-DND

Acoustical studies of atmospheric events like convective storms, shear-induced turbulence, acoustic gravity waves, microbursts, hurricanes, and clear air turbulence (CAT) over the past thirty years have established that these events are strong emitters of infrasound. Several mechanisms for the production of infrasound have been proposed, for example by the acceleration of vorticity or by space-time correlations of the turbulent Reynolds stresses (Lighthill theory). Electromagnetic (EM) sensors suffer two severe disadvantages in the detection of clear air turbulence and severe storms. The first is the inability to receive returns in clear air, where reflective targets (precipitation, particulate matter) are absent. The second disadvantage is that EM systems, being active, require scanning to locate an event, as opposed to a passive infrasonic array, which receives infrasonic radiation independently of event location. Further, EM systems, even weather radar ("NEXRAD"), do not have the extensive range (hundreds of miles) characteristic of infrasound. The leading laboratory for studies on atmospheric infrasound over the past thirty years has been the Environmental Technology Laboratory of the National Oceanic and Atmospheric Administration. This laboratory conducted measurements of infrasound from many sources, among which clear air turbulence was but a small part of the overall program. The summary of the results of this program suggests for development of a practical detection system. In other words, despite the progress made in this area, there does not exist today a National network of stations to monitor infrasound from turbulence. Under Innovative Partnership Program, Researchers at NASA Langley Research Center have been working to achieve that goal. As a first step, NASA Langley has designed and developed a portable infrasonic detection system which can be used to make useful infrasound measurements at a location where it was not possible previously. The design and results of the compact system, based upon laboratory and field experiments, will be presented.

Qamar Shams↗

De novo design of high-affinity binders of bioactive helical peptides

Many peptide hormones form an α-helix on binding their receptors, and sensitive methods for their detection could contribute to better clinical management of disease. De novo protein design can now generate binders with high affinity and specificity to structured proteins. However, the design of interactions between proteins and short peptides with helical propensity is an unmet challenge. Here we describe parametric generation and deep learning-based methods for designing proteins to address this challenge. We show that by extending RFdiffusion to enable binder design to flexible targets, and to refining input structure models by successive noising and denoising (partial diffusion), picomolar-affinity binders can be generated to helical peptide targets by either refining designs generated with other methods, or completely de novo starting from random noise distributions without any subsequent experimental optimization. The RFdiffusion designs enable the enrichment and subsequent detection of parathyroid hormone and glucagon by mass spectrometry, and the construction of bioluminescence-based protein biosensors. The ability to design binders to conformationally variable targets, and to optimize by partial diffusion both natural and designed proteins, should be broadly useful.

59 BASIC BIOLOGICAL SCIENCES↗

Using CRISPR/Cas13a technologies to detect miRNA [DOE SULI Internship Report]

Micro ribonucleic acids (miRNA) give our immune systems the ability to recognize viruses and other pathogens by their complementary single-stranded RNA (ssRNA) produced in the reproduction of the pathogen in our cells. When miRNA of a specific sequence is detected in a cell sample, it can be assumed that the immune system is activated and attempting to track down the infection. This pathway can be utilized to diagnose infection from a pathogen before the individual even develops symptoms, aiding in early disease detection and proper treatment. One of the ways that we can detect miRNA is through an assay of clustered regularly interspaced short palindromic repeats or “CRISPR” and the bacterial protein Cas13a. This report details discoveries made while attempting to optimize this assay for miRNA detection. After looking at several different factors within the assay, it was determined that some factors, such as reporter type and metallic ion concentration, are more impactful on the overall assay sensitivity than other factors, such as the overall concentration of Cas13a, CRISPR RNA (crRNA), or ssRNA reporter. It was also discovered that different sequences with different lengths require renewed optimization efforts, as each target has a unique binding affinity determined by the sequence length and composition. This information is crucial in the development of point of care molecular detection devices as they become sensitive enough to identify pathogens before they spread.

59 BASIC BIOLOGICAL SCIENCES↗

Space Debris Symposium (A6.) Measurements and Space Surveillance (1.): Measurements of the Small Particle Debris Cloud from the 11 January, 2007 Chinese Anti-satellite Test

On January 11, 2007, the Chinese military conducted a test of an anti-satellite (ASAT) system, destroying their own Fengyun-1C spacecraft with an interceptor missile. The resulting hypervelocity collision created an unprecedented number of tracked debris - more than 2500 objects. These objects represent only those large enough for the US Space Surveillance Network (SSN) to track - typically objects larger than about 5-10 cm in diameter. There are expected to be even more debris objects at sizes too small to be seen and tracked by the SSN. Because of the altitude of the target satellite (865 x 845 km orbit), many of the debris are expected to have long orbital lifetimes and contribute to the orbital debris environment for decades to come. In the days and weeks following the ASAT test, NASA was able to use Lincoln Laboratory s Haystack radar on several occasions to observe portions of the ASAT debris cloud. Haystack has the capability of detecting objects down to less than one centimeter in diameter, and a large number of centimeter-sized particles corresponding to the ASAT cloud were clearly seen in the data. While Haystack cannot track these objects, the statistical sampling procedures NASA uses can give an accurate statistical picture of the characteristics of the debris from a breakup event. For years computer models based on data from ground hypervelocity collision tests (e.g., the SOCIT test) and orbital collision experiments (e.g., the P-78 and Delta-180 on-orbit collisions) have been used to predict the extent and characteristics of such hypervelocity collision debris clouds, but until now there have not been good ways to verify these models in the centimeter size regime. It is believed that unplanned collisions of objects in space similar to ASAT tests will drive the long-term future evolution of the debris environment in near-Earth space. Therefore, the Chinese ASAT test provides an excellent opportunity to test the models used to predict the future debris environment. For this study, Haystack detection events are compared to model predictions to test the model assumptions, including debris size distribution, velocity distribution, and assumptions about momentum transfer between the target and interceptor. In this paper we will present the results of these and other measurements on the size and extent of collisional breakup debris clouds.

Matney, Mark J.↗

Accelerating template generation in resonant anomaly detection searches with optimal transport

We introduce Resonant Anomaly Detection with Optimal Transport (RAD-OT), a method for generating signal templates in resonant anomaly detection searches. RAD-OT leverages the fact that the samples from the conditional probability density of the target features vary approximately linearly along the optimal transport path connecting the resonant feature. This does not assume that the conditional density itself is linear with the resonant feature, allowing RAD-OT to efficiently capture multimodal relationships, changes in resolution, etc. By solving the optimal transport problem, RAD-OT can quickly build a template by interpolating between the background distributions in two sideband regions. We demonstrate the performance of RAD-OT using the LHC Olympics R&D dataset, where we find comparable sensitivity and improved stability with respect to deep learning-based approaches.

Automation↗

First bromine doped cryogenic implosion at the National Ignition Facility

We report on the first experiment dedicated to the study of nuclear reactions on dopants in a cryogenic capsule at the National Ignition Facility (NIF). This was accomplished using bromine doping in the inner layers of the CH ablator of a capsule identical to that used in the NIF shot N140520. The capsule was doped with 3 × 1016 bromine atoms. The doped capsule shot, N170730, resulted in a DT yield that was 2.6 times lower than the undoped equivalent. The Radiochemical Analysis of Gaseous Samples (RAGS) system was used to collect and detect 79Kr atoms resulting from energetic deuteron and proton ion reactions on 79Br. RAGS was also used to detect 13N produced dominantly by knock-on deuteron reactions on the 12C in the ablator. High-energy reaction-in-flight neutrons were detected via the 209Bi(n,4n)206Bi reaction, using bismuth activation foils located 50 cm outside of the target capsule. The robustness of the RAGS signals suggests that the use of nuclear reactions on dopants as diagnostics is quite feasible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beyond the Hype: An Evaluation of Commercially Available Machine-Learning-Based Malware Detectors

There is a lack of scientific testing of commercially available malware detectors, especially those that boast accurate classification of never-before-seen (i.e., zero-day) files using machine learning (ML). Consequently, efficacy of malware detectors is opaque, inhibiting end users from making informed decisions and researchers from targeting gaps in current detectors. In this paper, we present a scientific evaluation of four prominent commercial malware detection tools to assist an organization with two primary questions: To what extent do ML-based tools accurately classify previously and never-before-seen files? Is purchasing a network-level malware detector worth the cost? To investigate, we tested each tool against 3,536 total files (2,554 or 72% malicious, 982 or 28% benign) of a variety of file types, including hundreds of malicious zero-days, polyglots, and APT-style files, delivered on multiple protocols. We present statistical results on detection time and accuracy, consider complementary analysis (using multiple tools together), and provide two novel applications of the recent cost-benefit evaluation procedure of Iannacone & Bridges. Although the ML-based tools are more effective at detecting zero-day files and executables, the signature-based tool might still be an overall better option. Both network-based tools provide substantial (simulated) savings when paired with either host tool, yet both show poor detection rates on protocols other than HTTP or SMTP. Our results show that all four tools have near-perfect precision but alarmingly low recall, especially on file types other than executables and office files—37% of malware, including all polyglot files, were undetected. Priorities for researchers and takeaways for end users are given. Code for future use of the cost model is provided.

97 MATHEMATICS AND COMPUTING↗

Optimization of the BDX experiment for Light Dark Matter searches at JLab

The Light Dark Matter (LDM) hypothesis postulates the existence of a new class of sub GeV particles, neutral under Standard Model (SM) interactions. In its simplest form, LDM consists of particles ¿ with masses below 1 GeV/c2, interacting with SM particles via a new force mediated by a light, spin-1 boson A0, commonly referred to as “Dark Photon”. This framework envisions a distinct “Dark Sector” with its own particles and interactions, offering a theoretically well motivated explanation for Dark Matter, consistent with astrophysical observations and a thermal production mechanism. The Beam Dump eXperiment (BDX) is an approved experiment at Jefferson Lab designed to search for Light Dark Matter. BDX will utilize an 11 GeV electron beam impinging on a thick target to produce a forward-boosted secondary beam of Light Dark Matter particles, which will then be detected by a dedicated downstream detector. Approved in 2018, BDX is expected to be commissioned in 2026 and run in 2027-2029. My thesis focuses on the preparatory work to deploy the BDX experiment. The detector design has been optimized to balance practicality with enhanced Light Dark Matter detection capabilities. Extensive characterization of detector components has been performed to ensure a precise understanding of detector response. A custom Monte Carlo framework has been developed to simulate Light Dark Matter signal and explore various theoretical models of interest. Additionally, a comprehensive data analysis framework has been developed to maximize the experiment sensitivity to Light Dark Matter, with optimizations based on expected detector performance. The ultimate goal of this thesis is to optimize BDX as a flagship experiment in Light Dark Matter searches, enabling it to probe different Dark Matter models.

Spreafico, M. [Univ. of Genova (Italy)]↗

Scoping Study: Scintillator Array for Fission Correlation Studies

This scoping study uses a simulation based on the PROSPECT (1) detector to assess the conceptual design of a modular system that could efficiently and simultaneously measure the Prompt Fast Neutron Spectrum (PFNS), the prompt fission neutron multiplicity, the prompt fission gamma-ray multiplicity and total energy, as well as temporal and angular correlations between the detected particles. The proposed experiment would require a mono-energetic pulsed neutron beam incident on an actinide target in the center of the detector. Beam induced backgrounds due to elastic and inelastic neutron scattering on the target are considered, while other backgrounds are ignored for this study.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Computed Tomography Scanning and Geophysical Measurements of UW Enterprises LP 1-250512-129 Well in Southwestern Indiana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Illinois Basin core of the Upper Devonian-Early Mississippian New Albany Shale Formation from Posey County, Indiana. The primary impetus of this work is a collaboration between Indiana Geological and Water Survey at Indiana University Bloomington, NETL, and Woolsey Operating Company LLC to characterize and make publicly available core information from the New Albany Shale of the Illinois Basin. Core characterization of this unconventional oil/gas well will aid in understanding the lithology changes and the fracture complexity of the New Albany Shale. There is a potential for this formation to be developed in the future for critical mineral and rare earth element (CM/REE) extraction. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/uw-enterprises. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on this core. None of the equipment used was suitable for direct visualization of the pore space in the fine-grained structures studied; however, fractures, discontinuities, and millimeter-scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Targeted higher resolution CT scanning of select sections was performed with NETL’s industrial and micro-CT scanner. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

Revisiting the δ Scuti star FG Virginis using Kepler K2 and TESS data

FG Virginis is a δ Scuti variable star that was the target of several ground-based multisite photometric campaigns from 1992 to 2004. Over 75 pulsation frequencies were detected (Breger et al., Astron. Astrophys., 2005, 435, 955–965), more than for any other δ Sct star before the era of space photometry. FG Vir was observed for 52 days in 30-minute cadence photometry by the NASA Kepler spacecraft K2 mission in 2016, and for 23 days in 2-minute cadence photometry by the NASA TESS spacecraft in 2021. We present light curves and amplitude spectra obtained from these space missions. We find around 30 significant frequencies in the K2 data, and more than 100 significant frequencies in the TESS data. There is good correspondence between the first 10 or so highest-amplitude modes found in the K2 and TESS data and those found from the ground-based multisite campaigns, although the amplitude order is slightly different, indicating some stability in mode frequencies and amplitudes spanning 20 years. However, the 9th highest-amplitude mode of Breger et al. has moved down considerably in amplitude rank, while the 35th highest-amplitude mode has moved up to near the top ten as seen in both the K2 and TESS data. We find several low frequencies between 0.3 and 3 cycles per day in the TESS data that were not detected using the ground-based data. If low-frequency pulsations are confirmed, FG Vir would be classified as a δ Sct/γ Dor hybrid variable star. We also review stellar model results and some of the challenges for asteroseismology for this well-studied δ Sct star.

79 ASTRONOMY AND ASTROPHYSICS↗

Impaired motion detection preceding smooth eye movements.

Experiments have been carried out that suggest that the observed psychophysical impairment of motion detection in man may not occur equally over the entire visual field. Instead, if impaired motion detection is a consequence of redirection of 'attention' to another portion of the visual field, then movement detection may be impaired the most in the fovea and the least in the region of the subsequent target.

Richards, W.↗

Experimental limits on the velocities of sodium atoms sputtered from solid surfaces by hydrogen ions

Optical emission at 589.0 nm by sodium atoms sputtered from solid targets by hydrogen molecular ions was observed, and no accompanying broadening or shifts of this line could be detected relative to that from a laboratory lamp. This allowed an upper limit of about 500,000 cm/sec on the mean speed of ejected sodium atoms to be calculated. The results are consistent with the hypothesis that the atomic sodium cloud surrounding Io is produced by this mechanism.

Stoner, J. O., Jr.↗

Evaluation of Ocean Color Scanner (OCS) photographic and digital data: Santa Barbara Channel test site, 29 October 1975 overflight

A summary of Ocean Color Scanner data was examined to evaluate detection and discrimination capabilities of the system for marine resources, oil pollution and man-made sea surface targets of opportunity in the Santa Barbara Channel. Assessment of the utility of OCS for the determination of sediment transport patterns along the coastal zone was a secondary goal. Data products provided 1975 overflight were in digital and analog formats. In evaluating the OCS data, automated and manual procedures were employed. A total of four channels of data in digital format were analyzed, as well as three channels of color combined imagery, and four channels of black and white imagery. In addition, 1:120,000 scale color infrared imagery acquired simultaneously with the OCS data were provided for comparative analysis purposes.

Kraus, S. P.↗

Forest Fire Mapping

The Fire Logistics Airborne Mapping Equipment (FLAME) system, mounted in a twin-engine and airplane operated by the U.S. Forest Service (USFS) of the U.S. Department of Agriculture (USDA), is an airborne instrument for detecting and pinpointing forest fires that might escape ground detection. The FLAME equipment rack includes the operator interface, a video monitor, the system's control panel and film output. FLAME's fire detection sensor is an infrared line scanner system that identifies fire boundaries. Sensor's information is correlated with the aircraft's position and altitude at the time the infrared imagery is acquired to fix the fire's location on a map. System can be sent to a fire locale anywhere in the U.S. at the request of a regional forester. USFS felt a need for a more advanced system to deliver timely fire information to fire management personnel in the decade of the 1990s. The Jet Propulsion Laboratory (JPL) conducted a study, jointly sponsored by NASA and USDA, on what advanced technologies might be employed to produce an end-to-end thermal infrared fire detection and mapping system. That led to initiation of the Firefly system, currently in development at JPL and targeted for operational service beginning in 1992. Firefly will employ satellite-reference position fixing and provide performance superior to FLAME.

Source record↗