‘Soft’ amplifier circuits based on field-effect ionic transistors

Soft materials can be used as the building blocks for electronic devices with extraordinary properties. We introduce a theoretical model for a field-effect transistor in which ions are the gated species instead of electrons. Our model incorporates readily-available soft materials, such as conductive porous membranes and polymer-electrolytes to represent a device that regulates ion currents and can be integrated as a component in larger circuits. By means of Nernst–Planck numerical simulations as well as an analytical description of the steady-state current we find that the responses of the system to various input voltages can be categorized into ohmic, sub-threshold, and active modes. This is fully analogous to what is known for the electronic field-effect transistor (FET). Pivotal FET properties such as the threshold voltage and the transconductance crucially depend on the half-cell redox potentials of the source and drain electrodes as well as on the polyelectrolyte charge density and the gate material work function. We confirm the analogy with the electronic FETs through numerical simulations of elementary amplifier circuits in which we successfully substitute the electronic transistor by an ionic transistor.

42 ENGINEERING↗

An unwanted guest in the electrochemical oxidation of high-voltage Li-ion battery electrolytes: the life of highly reactive protons

Lithium-ion batteries (LIBs) are central to the urgent societal need to decarbonize both transportation and energy storage on the grid. Unfortunately, despite their attractive energy/power density, as well as high coulombic and energy efficiencies, further improvement of this technology – especially their durability – is desperately needed. To support these efforts, our study focuses on fundamental understanding of the decomposition pathways for LIB electrolytes at the cathode–electrolyte interface (CEI), as the nature of these reactions directly controls the extent to which cell capacity and voltage decays in these systems. In this study, we employ electrochemical methods, coupled with product analysis using NMR spectroscopy and mass spectrometry, to determine the decomposition mechanisms in both model and technologically relevant electrolytes. Remarkably, we discovered the electrochemical formation of protons with high chemical activity, comparable to known superacids, at potentials relevant to practical Li-ion batteries. Their reactivity toward every individual component of the CEI provides a unified thermochemical origin for a myriad of side reactions that are commonly associated with the electrochemical reaction. In particular, electrochemically generated protons react with intact EC molecules to form CO 2 and other short and long chain ethers. They also undergo an acid–base reaction with LiPF 6 , to form the weaker acid HF, and with the cathode active material, leaching transition metals into the electrolyte. Collectively, the results of this study all point to the urgent need to either mitigate this proton formation or introduce benign harvesting additives via new electrolyte design strategies.

Ilic, Stefan [Argonne National Laboratory (ANL), A↗

Ensemble Federated Machine Learning‐Based Cybersecurity Situational Awareness in Microgrid Network

Cyber-physical microgrids are vulnerable to stealthy cybersecurity threats that disguise their actions through the exploitation of system knowledge. Such actions can severely impacts microgrids deployed in defense bases, slowing the response time of military forces during national emergencies. Several machine-learning algorithms have been proposed to detect intrusions in the grid networks; however, these traditional machine-learning algorithms lack data privacy and are subject to several adversarial machine-learning threats. This paper proposes a novel federated machine learning (FML)-based three-model framework to detect and identify stealthy data-integrity attacks while ensuring data privacy in microgrid networks. The proposed architecture uses a variational mode decomposition technique to extract derived features from incoming measurement and control datasets. The extraction of these derived features allows FML models to learn minute variations in data patterns that allow them to perform significantly better than the models trained with generic datasets consisting of raw features. Our experimental results show the efficient performance of the proposed methodology against different types of data integrity attacks while considering primary and secondary controllers in microgrids. Further, the applied FML-integrated random forest ensemble algorithm outperforms the existing generic FML algorithms during noisy and noise-free datasets with prediction latencies of only 91–134 µs per sample within the 0.1 s sampling interval and requires communication bandwidth of around ∼8.25 KB/s at the control center and ∼2.7 KB/s per edge client for communication.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrohydrodynamic interaction induced by a dielectric barrier discharge

In the present work an experimental investigation on the electrohydrodynamic (EHD) interaction effect, induced by means of a dielectric barrier discharge on a 1 atm subsonic air flow, is described. The air flow is obtained in an open circuit blowing wind tunnel at different air speeds. A plane plasma panel equipped with a dielectric discharge barrier system is immersed in the flow. A single phase sinusoidal power supply system, a superposition of a single phase sinusoidal system with a dc voltage supply, and a three phase symmetrical power supply configuration are considered. Electric, fluid dynamic, and spectroscopic diagnostic techniques are utilized. Pitot probe measurements are performed in the boundary layer on the plasma panel surface. Schlieren imaging is done to visualize the plasma sheath. Vibrational and rotational temperatures are evaluated by means of spectroscopic techniques. The force induced on the flow by the dielectric barrier discharge acts on the ions of the non-neutral sheath ahead of the plasma filament when travelling on the panel surface only. This causes a reduction of the time interval during which the force is active. The EHD effect and the momentum transfer to the gas flow in the boundary layer are reduced when the flow speed grows. An increase of the supply frequency and of the supply voltage causes an increase of the momentum transfer. In these experiments no significant increase of the efficiency of EHD effect is observed when utilizing the superposition of a dc voltage to a single phase power supply or a three phase power supply.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of the ITER ICRF Antenna plug as expected from TOPICA matrices

The performances of the present ICRF antenna plug design is evaluated by means of the TOPICA 24x24 matrix for plasma loading supplemented by 4-port junction (4PJ) matrices. For their interpretation these results are compared with a cruder modeling by the semi-analytical code ANTITER II. From this analysis we conclude: (1) The broadbanding effect of the service stub on the response of the 4PJ made for one triplet is maintained for the complete array for all the heating and current drive phasings. (2) For a given maximum voltage of the 8 feeding lines the radiated power capability is roughly constant in the entire frequency band. (3) The power capability of the array is significantly dependent on the distance of the antenna to the Last Closed Flux Surface, the density profile in the scrape-off layer (SOL) and on the toroidal and poloidal phasings. The dependence on phasing is stronger for wider SOL (4) For a not too optimistic plasma density profile (Sc2 shortl7) a power capability exceeding 20 MW is only obtained for the 00 {pi}{pi} heating toroidal phasing and for the co-current drive phasing in the upper part of the frequency band for a maximum voltage in the complete system of 45 kV. (5), On account of the plasma gyrotropy the quadrature poloidal phasing introduced by hybrid feeding must excite waves propagating upwards in the ITER configuration to obtain the best coupling, (6) The large power capability difference between opposite current drive phasings is attributed to the coupling between the toroidal and poloidal phasings induced by the poloidal steady magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Drive frequency dependent phase imaging in piezoresponse force microscopy

The drive frequency dependent piezoresponse (PR) phase signal in near-stoichiometric lithium niobate crystals is studied by piezoresponse force microscopy. It is clearly shown that the local and nonlocal electrostatic forces have a great contribution to the PR phase signal. The significant PR phase difference of the antiparallel domains are observed at the contact resonances, which is related to the electrostatic dominated electromechanical interactions of the cantilever and tip-sample system. Moreover, the modulation voltage induced frequency shift at higher eigenmodes could be attributed to the change of indention force depending on the modulation amplitude with a piezoelectric origin. The PR phase of the silicon wafer is also measured for comparison. It is certificated that the electrostatic interactions are universal in voltage modulated scanning probe microscopy and could be extended to other phase imaging techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flexible semi-around gate silicon nanowire tunnel transistors with a sub-kT/q switch

Tunnel field-effect transistors (TFETs) with a subthreshold swing (SS) < 60 mV/dec are expected to be active devices in low-power flexible systems, potentially lowering operational voltage by virtue of steep switching behavior via band-to-band tunneling. In silicon (Si) channel materials, however, it still remains a challenge to obtain SS smaller than 60 mV/dec. In this study, we experimentally demonstrate the sub-60 mV/dec operation of a flexible semi-around gate TFET on a plastic substrate using Si nanowires (SiNWs) as the channel material. With the combined advantages of selectively thinned SiNW channels (width ∼ 15 nm and height ∼ 40 nm) and high-κ (Al{sub 2}O{sub 3} ∼ 7 nm) gate dielectric, in conjunction with an abrupt degenerate source junction, the device with a channel length of ∼500 nm exhibits a minimal SS of ∼42 mV/dec at room temperature. Moreover, mechanical bendability of the device indicates that it has stable and good fatigue properties, providing an important step towards the realization of steep-slope switches for low-power and energy-efficient flexible electronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhanced current quantization in high-frequency electron pumps in a perpendicular magnetic field

We present experimental results of high-frequency quantized charge pumping through a quantum dot formed by the electric field arising from applied voltages in a GaAs/AlGaAs system in the presence of a perpendicular magnetic field B. Clear changes are observed in the quantized current plateaus as a function of applied magnetic field. We report on the robustness in the length of the quantized plateaus and improvements in the quantization as a result of the applied B field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Colloquium : Anomalous metals: Failed superconductors

The observation of metallic ground states in a variety of two-dimensional electronic systems poses a fundamental challenge for the theory of electron fluids. Here evidence is analyzed for the existence of a regime, called the “anomalous metal regime,” in diverse 2D superconducting systems driven through a quantum superconductor to metal transition by tuning physical parameters such as the magnetic field, the gate voltage in the case of systems with a metal-oxide semiconductor field-effect transistor (MOSFET) geometry, or the degree of disorder. The principal phenomenological observation is that in the anomalous metal, as a function of decreasing temperature, the resistivity first drops as if the system were approaching a superconducting ground state, but then saturates at low temperatures to a value that can be orders of magnitude smaller than the Drude value. The anomalous metal also shows a giant positive magnetoresistance. Thus, it behaves as if it were a “failed superconductor.” This behavior is observed in a broad range of parameters. It will be moreover exhibited, by theoretical solution of a model of superconducting grains embedded in a metallic matrix, that as a matter of principle such anomalous metallic behavior can occur in the neighborhood of a quantum superconductor to metal transition. Furthermore, it will be also argued that the robustness and ubiquitous nature of the observed phenomena are difficult to reconcile with any existing theoretical treatment and speculate about the character of a more fundamental theoretical framework.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cascaded Quadruple Active Bridge Structures for Multilevel DC to Three-Phase AC Conversion

This paper introduces a multilevel architecture comprised of interconnected dc to three-phase ac converter units. To enable series connected operation, each converter unit contains a quadruple active bridge (QAB) converter that provides isolation between the dc side and each of the three ac sides. Since each converter unit transfers dc-side power as constant balanced three-phase power on the ac side, this implies instantaneous input-output power balance and allows elimination of bulk capacitive energy storage. In addition to minimizing required capacitance, the proposed approach simultaneously enables simplified dc-link controllers amenable to decentralized implementation, supports bidirectional power transfer, and exhibits a modular structure to enhance scalability. Isolation provided by the QAB allows a wide range of electrical configurations among multiple units in various dc-ac, ac-dc or ac-ac applications. In this paper, the focus is on series connections on the ac side to emphasize multilevel operation, and the approach is experimentally validated in a dc-ac system containing two cascaded converter units.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Queuing Up

The interconnection queue is the mechanism for grouping and ordering prospective generation projects for evaluating impacts on the bulk system. These days, with record-setting installations of wind generation capacity in the United States, it is difficult to find an interconnection queue that does not contain at least some wind generation projects; in the areas of the country with good or better wind resources, there may be dozens of prospective projects awaiting study. The result has been a much broader exposure within the electric power engineering community to the technical issues and challenges associated with wind generation.

17 WIND ENERGY↗

Developing VSC-HVDC Oscillation Damping Control Constraints in Unit Commitment

High-voltage direct current (HVDC) systems within the existing power grids will play a pivotal role in enabling high share of renewable power integration and transportation electrification. There is a need for transmission planning models to accurately capture the impact of VSC-HVDC oscillation damping control on the system planning and model the constraints in the security constrained unit commitment (SCUC) problem. In this paper, the SCUC problem in a hybrid DC-AC grid considering damping on electromechanical inter-area oscillation is studied. An electromechanical oscillation-driven transmission capability constraints are derived from system swing equation and incorporated into the SCUC. Multiple system damping control scenarios are set based on the extracted plausible bounds of damping coefficient and inertia constant to linearize the nonlinear expressions. The SCUC problem with proposed constraints is tested on the Reliability Test System Grid Modernization Lab Consortium (RTS-GMLC) via PLEXOS. The impact of the proposed constraints on regional generation, inertia, power flow, annual system cost, and renewable energy curtailment are fully assessed.

damping control↗

Challenges to Rural Service Transformers on Increased Electric Vehicle Charging Infrastructure

As Electric Vehicle (EV) electric charging demand increases so to does the corresponding load requirements for charging the vehicles. The expansion of power distribution assets is therefore a critical issue to address on whether rural service transformers can handle the increase in EV load demand. Large-scale EV deployment is likely to cause problems in the localized distributions systems bringing challenges such as increased load demand, increased system losses, and additional voltage drops. This paper investigates how rural service transformer resiliency plays an important role in these challenges. EV charging can create new load peaks exceeding the service transformer's rated capacity, thereby accelerating equipment aging. EV charging can also both positively and negatively affect transformer aging. The core purpose of this paper is to investigate that change in service life of rural service transformers.

Mukherjee, Srijib↗