Scientific and technical applications of a tethered satellite system

A Shuttle-borne tether system capable of deploying a tether to radial distances as great as 100 km was described by Rupp and Laue (1978). The system as discussed by Rupp and Laue would have a total mass of 700 kg and would be mounted on one Shuttle pallet. It would consist of a tether reel mechanism complete with a servo drive motor and control sensors, a boom with docking probe used for initial deployment and subsequent retrieval, some type of satellite weighing 175 kg, up to 100 km of synthetic or metallic tether approximately 1 mm in diameter, a digital control computer, and a control and display panel on the Orbiter aft flight deck for crew operation. The primary use of a tether system for geological applications would be in the measurement of those magnetic and gravitational fields associated with geological structures. The major appeal in connection with atmospheric applications is the system's ability to extend instrumentation down into the lower thermosphere and possibly the mesosphere.

Snoddy, W. C.↗

Numerical simulation of crossing/turbulent boundary layer interaction at Mach 8.3 comparison of zero and two-equation turbulence models

A 3D hypersonic crossing shock wave/turbulent boundary layer interaction is examined numerically. The test geometry consists of a pair of opposing sharp fins of angle alpha = 15 deg mounted on a flat plate. The freestream Mach number is 8.28. Two theoretical models are evaluated. The full 3D Reynolds-averaged Navier-Stokes equations are solved using the Baldwin-Lomax algebraic turbulent eddy viscosity model and the Rodi turbulence model. Computed results for both cases show good agreement with experiment for flat plate surface pressure and for pitot pressure and yaw angle profiles in the flowfield. General agreement is obtained for surface flow direction. Fair to poor agreement is obtained for surface heat transfer, indicating a need for more accurate turbulence models. The overall flowfield structure is similar to that observed in previous crossing shock interaction studies.

Narayanswami, N.↗

Human-in-the-loop evaluation of RMS Active Damping Augmentation

Active Damping Augmentation is the insertion of Controls-Structures Integration Technology to benefit the on-orbit performance of the Space Shuttle Remote Manipulator System. The goal is to reduce the vibration decay time of the Remote Manipulator System following normal payload maneuvers and operations. Simulation of Active Damping Augmentation was conducted in the realtime human-in-the-loop Systems Engineering Simulator at the NASA Johnson Space Center. The objective of this study was to obtain a qualitative measure of operational performance improvement from astronaut operators and to obtain supporting quantitative performance data. Sensing of vibratory motions was simulated using a three-axis accelerometer mounted at the end of the lower boom of the Remote Manipulator System. The sensed motions were used in a feedback control law to generate commands to the joint servo mechanisms which reduced the unwanted oscillations. Active damping of the Remote Manipulator System with an attached 3990 lb. payload was successfully demonstrated. Six astronaut operators examined the performance of an Active Damping Augmentation control law following single-joint and coordinated six-joint translational and rotational maneuvers. Active Damping Augmentation disturbance rejection of Orbiter thruster firings was also evaluated. Significant reductions in the dynamic response of the 3990 lb. payload were observed. Astronaut operators recommended investigation of Active Damping Augmentation benefits to heavier payloads where oscillations are a bigger problem (e.g. Space Station Freedom assembly operators).

Demeo, Martha E.↗

Pre-metatarsal skeletal development in tissue culture at unit- and microgravity

Explant organ culture was used to demonstrate that isolated embryonic mouse pre-metatarsal mesenchyme is capable of undergoing a series of differentiative and morphogenetic developmental events. Mesenchyme differentiation into chondrocytes, and concurrent morphogenetic patterning of the cartilage tissue, and terminal chondrocyte differentiation with subsequent matrix mineralization show that cultured tissue closely parallels in vivo development. Whole mount alizarin red staining of the cultured tissue demonstrates that the extracellular matrix around the hypertrophied chondrocytes is competent to support mineralization. Intensely stained mineralized bands are similar to those formed in pre-metatarsals developing in vivo. We have adapted the culture strategy for experimentation in a reduced gravity environment on the Space Shuttle. Spaceflight culture of pre-metatarsals, which have already initiated chondrogenesis and morphogenetic patterning, results in an increase in cartilage rod size and maintenance of rod shape, compared to controls. Older pre-metatarsal tissue, already terminally differentiated to hypertrophied cartilage, maintained rod structure and cartilage phenotype during spaceflight culture.

NASA Discipline Developmental Biology↗

Ares I Scale Model Acoustic Test Instrumentation for Acoustic and Pressure Measurements

Ares I Scale Model Acoustic Test (ASMAT) is a 5% scale model test of the Ares I vehicle, launch pad and support structures conducted at MSFC to verify acoustic and ignition environments and evaluate water suppression systems Test design considerations 5% measurements must be scaled to full scale requiring high frequency measurements Users had different frequencies of interest Acoustics: 200 - 2,000 Hz full scale equals 4,000 - 40,000 Hz model scale Ignition Transient: 0 - 100 Hz full scale equals 0 - 2,000 Hz model scale Environment exposure Weather exposure: heat, humidity, thunderstorms, rain, cold and snow Test environments: Plume impingement heat and pressure, and water deluge impingement Several types of sensors were used to measure the environments Different instrument mounts were used according to the location and exposure to the environment This presentation addresses the observed effects of the selected sensors and mount design on the acoustic and pressure measurements

Vargas, Magda B.↗

The measurement of the ground wind structure at Wallops Island

The mean and turbulence characteristics of the surface wind measured near the Atlantic coast were measured. The experimental data were acquired from a 76 meter tall instrumented micrometeorological tower. Mean wind and turbulence measurements were made with two types of instrumentation consisting of cup vane and temperature probes, primarily used for mean profile measurements of velocity and temperature respectively. The second system, a hot film and thermocouple system, was used for measurement of turbulence variances and covariances and spectra. The cup vane system was used to acquire data from all wind directions, while the hot film system was primarily used for turbulence measurements from the two prevailing wind directions, south and northwest. The micrometeorological tower is a self standing nonguyed tower with five working platforms at 15.2m (50 ft.) intervals, with cup vane and aspirated temperature probes mounted at each platform.

Tielman, H. W.↗

Full-scale Skylab Apollo telescope mount deployment tests

During the initial stages of the NASA Skylab orbit, the Apollo telescope mount (ATM) is deployed by the deployment assembly (DA) which clears the multiple docking adapter axial docking port. This is an essential prerequisite to docking the command service module with the orbital workshop and subsequent occupancy of the workshop by the Apollo three-man crew. The objectives of the full-scale NASA Skylab ATM deployment test program were (1) to evaluate the design concept of the DA and deployment mechanisms while functioning in a zero-g environment with simulated ATM mass properties and (2) to evaluate the effects of handling, transporting, and deployment with respect to the structural geometry and stability of the DA.

Fricker, G. F.↗

Expandable pallet for space station interface attachments

A foldable expandable pallet having a basic square configuration is disclosed. Each pallet is comprised of a plurality of struts, joined together by node point fittings to make a rigid structure. Some of the struts have hinge fittings and are spring loaded to permit collapse of the module for stowage and transport to a space station. Dimensions of the pallet are selected to provide convenient, closely spaced attachment points between the relatively widely spaced trusses of a space station platform. A pallet is attached to a truss at four points; one close fitting hole; two oversize holes; and a slot; to allow for thermal expansion/contraction and for manufacturing tolerances. Applications of the pallet include its use in rotary or angular joints; servicing of splints; with gridded plates; as an instrument mounting bases; and as a roadbed for a Mobile Service Center (MSC).

Clarence J Wesselski↗

GRM - Observing the terrestrial gravity and magnetic fields in the 1990's

NASA is proposing to launch a new geopotential fields exploration system called the Geopotential Research Mission (GRM). Two spacecraft will be placed in a circular polar orbit at 160 km altitude. Distances between these satellites will vary from 100 to 600 km. Both scalar and vector magnetic fields will be measured by magnetometers mounted on a boom positioned in the forward direction on the lead satellite. Gravity data will be computed from the measured change in distance between the two spacecraft. This quantity, called the range-rate, will be determined from the varying frequency (Doppler shift) between transmitter and receiver on each satellite. Expected accuracies (at the one-sigma level) are: gravity field, 1.0 milliGal, 5 cm geoid height; magnetics, scalar field 2 nT, vector to 20 arcsec, both resolved to less than 100 km. With these more accurate and higher resolution data, it will be possible to investigate the earth's structure from the crust (with the shorter wavelength gravity and magnetic anomalies) through the mantle (from the intermediate wavelength gravity field) and into the core (using the longer wavelength gravity and magnetic fields).

Taylor, P. T.↗

Space Shuttle Transportation (Roll-Out) Loads Diagnostics

The Space Transportation System (STS) consists of three primary components; an Orbiter Vehicle, an External Fuel Tank, and two Solid Rocket Boosters. The Orbiter Vehicle and Solid Rocket Boosters are reusable components, and as such, they are susceptible to durability issues. Recently, the fatigue load spectra for these components have been updated to include load histories acquired during the rollout phase of the STS processing for flight. Using traditional program life assessment techniques, the incorporation of these "rollout" loads produced unacceptable life estimates for certain Orbiter structural members. As a result, the Space Shuttle System Engineering and Integration Office has initiated a program to re-assess the method used for developing the "rollout" loads and performing the life assessments. In the fall of 2003 a set of tests were preformed to provide information to either validate existing load spectra estimation techniques or generate new load spectra estimation methods. Acceleration and strain data were collected from two rollouts of a partial-stack configuration of the Space Shuttle. The partial stack configuration consists of two Solid Rocket Boosters tied together at the upper External Tank attachment locations mounted on the Mobile Launch Platform carried by a Crawler Transporter (CT). In the current analysis, the data collected from this test is examined for consistency in speed, surface condition effects, and the characterization of the forcing function. It is observed that the speed of the CT is relatively stable. The dynamic response acceleration of the partial-stack is slightly sensitive to the surface condition of the road used for transport, and the dynamic response acceleration of the partial-stack generally increases as the transport speed increases. However, the speed sensitivity is dependent on the measurement location. Finally, the character of the forcing function is narrow-banded with the primary drivers being harmonics of two CT speed dependent excitations. One source is an excitation due to the CT treads striking the road surface, and the second is unknown.

Elliott, Kenny B.↗

Two-Dimensional Bifurcated Inlet Variable Cowl Lip Test Completed in 10- by 10-Foot Supersonic Wind Tunnel

Researchers at the NASA Glenn Research Center at Lewis Field successfully tested a variable cowl lip inlet at simulated takeoff conditions in Glenn s 10- by 10-Foot Supersonic Wind Tunnel (10x10 SWT) as part of the High-Speed Research Program. The test was a follow-on to the Two-Dimensional Bifurcated (2DB) Inlet/Engine test. At the takeoff condition for a High-Speed Civil Transport aircraft, the inlet must provide adequate airflow to the engine with an acceptable distortion level and high-pressure recovery. The test was conducted to study the effectiveness of installing two rotating lips on the 2DB Inlet cowls to increase mass flow rate and eliminate or reduce boundary layer flow separation near the lips. Hardware was mounted vertically in the test section so that it extended through the tunnel ceiling and that the 2DB Inlet was exposed to the atmosphere above the test section. The tunnel was configured in the aerodynamic mode, and exhausters were used to pump down the tunnel to vacuum levels and to provide a maximum flow rate of approximately 58 lb/sec. The test determined the (1) maximum flow in the 2DB Inlet for each variable cowl lip, (2) distortion level and pressure recovery for each lip configuration, (3) boundary layer conditions near variable lips inside the 2DB Inlet, (4) effects of a wing structure adjacent to the 2DB Inlet, and (5) effects of different 2DB Inlet exit configurations. It also employed flow visualization to generate enough qualitative data on variable lips to optimize the variable lip concept. This test was a collaborative effort between the Boeing Company and Glenn. Extensive inhouse support at Glenn contributed significantly to the progress and accomplishment of this test.

Hoffman, T. R.↗

Hot Views on Cold Crystals: The Application of Thermal Imaging in Cryocrystallography

We have used thermal imaging techniques to visualize the cryocooling processes of macromolecular crystals. Cryocooling is a common technique used for structural data collection to reduce radiation damage in intense X-ray beams and decrease the thermal motion of the atoms. From the thermal images it was clear that during cryocooling a cold wave progresses through a crystal starting at the face closest to the origin of the cold stream and ending at the point furthest away. As an extension to this work, we used thermal imaging to study small crystals, held in a cryo-loop, in the presence of vitrified mother liquor. The different infrared transmission and reflectance properties of the crystal in comparison to the mother liquor surrounding it are thought to be the parameter that produces the contrast that makes the crystal visible. An application of this technology may be the determination of the exact location of small crystals in a cryo-loop for automated structural genomics studies. Data from initial tests in support of application development was recorded for lysozyme crystals and for bFGF/dna complex crystals, which were cryocooled and imaged in large loops, both with visible light and with infrared radiation. The crystals were clearly distinguished from the vitrified solution in the infrared spectrum, while in the case of the bFGF/dna complex the illumination had to be carefully manipulated to make the crystal visible in the visible spectrum. These results suggest that the thermal imaging may be more sensitive than visual imaging for automated location of small crystals. However, further work on small crystals robotically mounted at SSRL did not clearly visualize those crystals. The depth of field of the camera proved to be limiting and a different cooling geometry was used, compared to the previous, successful experiments. Analysis to exploit multiple images to improve depth of field and experimental work to understand cooling geometry effects is ongoing. These results will be presented along with advantages and disadvantages of the technique and a discussion of how it might be applied.

Snell, Eddie↗

NASA Tech Briefs, September 2012

Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load.

Source record↗

Fully Integrated, Miniature, High-Frequency Flow Probe Utilizing MEMS Leadless SOI Technology

This work focused on developing, fabricating, and fully calibrating a flowangle probe for aeronautics research by utilizing the latest microelectromechanical systems (MEMS), leadless silicon on insulator (SOI) sensor technology. While the concept of angle probes is not new, traditional devices had been relatively large due to fabrication constraints; often too large to resolve flow structures necessary for modern aeropropulsion measurements such as inlet flow distortions and vortices, secondary flows, etc. Mea surements of this kind demanded a new approach to probe design to achieve sizes on the order of 0.1 in. (.3 mm) diameter or smaller, and capable of meeting demanding requirements for accuracy and ruggedness. This approach invoked the use of stateof- the-art processing techniques to install SOI sensor chips directly onto the probe body, thus eliminating redundancy in sensor packaging and probe installation that have historically forced larger probe size. This also facilitated a better thermal match between the chip and its mount, improving stability and accuracy. Further, the leadless sensor technology with which the SOI sensing element is fabricated allows direct mounting and electrical interconnecting of the sensor to the probe body. This leadless technology allowed a rugged wire-out approach that is performed at the sensor length scale, thus achieving substantial sensor size reductions. The technology is inherently capable of high-frequency and high-accuracy performance in high temperatures and harsh environments.

Ned, Alex↗

Organic Matter in Itokawa Particles

The first Hayabusa mission returned samples from the near-Earth S-type asteroid 25143 Itokawa to Earth in 2010[1]. Although Itokawa has a lithology related to ordinary chondrites(OCs) that typically have low organic contents, several Itokawa particles were found to contain organic matter (OM)[2-5]. However, there was not an explicit conclusion to the origin of the observed OMin these early studies. We have extended our search for OM into other Itokawa grains. Here, we report extraterrestrial OM (macromolecular carbon and amino acids) observed in six Itokawa particles(including a category1 particle: RA-QD02-0162[#62; also nicknamed “Amazon”],and five category3 carbon-rich particles:RA-QD02-0012[#12], RA-QD02-0078[#78], RB-CV-0029[#29], RB-CV-0080 [#80] and RB-QD04-0052[#52]).All allocated Itokawa samples were initially analysed by spot and point-by-point mapping Raman spectroscopic analysis at the Open University, UK. Amazon was then transferred and mounted into indium on an aluminium stub, which was studied with a NanoSIMS 50L ion microprobe for its H,C,N isotopic compositions. The rest of the samples were mounted in sterile gold foils, and the amino acid contents of their acid hydrolysed hot water extracts were obtained with a liquid chromatography with tandem fluorescence and accurate mass detection at NASA Goddard Space Flight Center, USA. Based on the observation of the Raman parameters(e.g. the peak locations and widths of the defect (D) and graphite (G) bands)[6], a significant variety of carbonaceous materials has been observed in Amazon. The carbonaceous materials include primitive and unaltered OM that shares similarity with the IOM in primitive (CI,CM,CR) carbonaceous chondrites, as well as OM that has been heavily graphitised. The organic structure of the heated material is best represented by nanocrystalline graphite, comparable to that observed for metamorphosed meteorites (e.g., L3–6 Inman, Tieschitz and New Concord,CV3 Allende, and EH4 Indarch),suggesting peak metamorphic temperatures (PMT) of >~600°C. The thermal history recorded in the graphitic OM agrees with PMT estimates for returned Itokawa regolith grains (600–800°C)[7].We have obtained the H,C,N isotopic compositions for the primitive OM in Amazon, which exhibits unambiguously extraterrestrial isotopic signatures (δD = +4868±2288‰; δ13C = −24±5‰; δ15N = +344±20‰), contrasting to the typically negative isotopic values obtained for terrestrial organic matter[8]. The δD and δ13C values of the organic material in Amazon are comparable to OCs, however, the δ15N value is higher than that typically observed for OCs (δ15N = −47 to +36‰), and is similar to that of CRs (δ15N = +153 to +309‰)[9].Our data suggest a genetic link between the primitive organic material observed in Itokawa to CRs and IDPs for they share similar D, 13C and 15N enrichments[10].The high carbon contents of the five category 3 Itokawa particles suggest potentially higher OM abundances, hence we extracted and analysed amino acids in these samples. Although terrestrial contamination was observed primarily as L-protein amino acids, several terrestrially uncommon non-protein amino acids were also observed at low abundances, such as β-aminoisobutyric acid (β-AIB),β-amino-n-butyric acid (β-ABA), and β-alanine. Itokawa amino acid content observed here was dissimilar to thermally altered OCs, but preliminarily analogous to more aqueously altered CR2s.Continued evolution of Itokawa is evident by the in fall of primitive organic material derived from CRs/IDPs, accounting for a complex interplay between the remnant Itokawa silicates with exogenous organics. The results reported here are the first evidence of extraterrestrial OM in asteroid material from a sample-return mission, showcasing a working protocol for analysing samples returned by the Hayabusa2 and OSIRIS-REx missions

Q. H. S. Chan↗

NASCAP/LEO calculations of current collection

NASCAP/LEO is a 3-dimensional computer code for calculating the interaction of a high-voltage spacecraft with the cold dense plasma found in Low Earth Orbit. Although based on a cubic grid structure, NASCAP/LEO accepts object definition input from standard computer aided design (CAD) programs so that a model may be correctly proportioned and important features resolved. The potential around the model is calculated by solving the finite element formulation of Poisson's equation with an analytic space charge function. Five previously published NASCAP/LEO calculations for three ground test experiments and two space flight experiments are presented. The three ground test experiments are a large simulated panel, a simulated pinhole, and a 2-slit experiment with overlapping sheaths. The two space flight experiments are a solar panel biased up to 1000 volts, and a rocket-mounted sphere biased up to 46 kilovolts. In all cases, the authors find good agreement between calculation and measurement.

Mandell, Myron J.↗

Flow Quality Survey of the 9- by 15-Foot Low Speed Wind Tunnel (2015 and 2016 Tests) Prior to Acoustic Improvement Modifications

A flow quality survey (FQS) was conducted in December 2015 and January 2016 to characterize the flow quality of the 9- by 15-Foot Low-Speed Wind Tunnel (9×15 LSWT) test section prior to the start of significant structural and acoustic modifications. The data from this FQS will be compared with data collected during a replicated FQS after completion of the acoustic improvement modifications. This document contains only the FQS data collected in December 2015 and January 2016 using the 15-ft survey rake and the 18-in. boundary layer rakes in the 9×15 LSWT. The spatial variation at one axial test section station (TSTA), nominally TSTA 198, and five vertical heights of the 15-ft survey rake was computed for Mach number, velocity, total and static pressure, total temperature, and flow angularity (pitch and yaw). Three hot-wire probes mounted to the 15-ft survey rake were used to measure turbulence intensity; however, data from a previous test entry were used as the mean turbulence intensity baseline value, as there were issues with the hot-wire performance. The boundary layer pressure profiles around the perimeter of the test section at TSTA 199 were also measured and the boundary layer heights computed. All calculated results are tabulated for each facility condition set point.

Johnson, Aaron M.↗

A technique for measurement of material damping in metals

The paper outlines the theory, design, and application of an apparatus based on the single beam resonant dwell technique to determine the damping capacity of metallic materials by measuring the response of a structural element to excitation at a modal frequency. In this apparatus, a cantilever beam specimen of a test material is clamped to a bar which is connected at one end to an electromagnetic shaker and at the other to a heavy base. The thickness of the bar at the base end is reduced by two saw cuts to provide a pivot around which the remainder of the bar can rotate when excited by the shaker which is connected to the bar by a rod passing through a hole in the base. The response of the supporting system to shaker excitation is measured with an accelerometer mounted on the bar at the root of the specimen. Specimen response is measured optically with a low-power microscope with a reticle. Specimen loss factor is determined in terms of acceleration at the beam root, beam tip displacement, and the beam natural frequency.

Heine, J. C.↗