At least 1,243 records · Page 69

Resource selection functions based on hierarchical generalized additive models provide new insights into individual animal variation and species distributions

Habitat selection studies are designed to generate predictions of species distributions or inference regarding general habitat associations and individual variation in habitat use. Such studies frequently involve either individually indexed locations gathered across limited spatial extents and analyzed using resource selection functions (RSFs) or spatially extensive locational data without individual resolution typically analyzed using species distribution models. Both analytical methodologies have certain desirable features, but analyses that combine individual- and population-level inference with flexible non-linear functions may provide improved predictions while accounting for individual variation. Here, we describe how RSFs can be fit using hierarchical generalized additive models (HGAMs) using widely available software, providing a means to explore individual variation in habitat associations and to generate species distribution maps. We used GPS tracking data from golden eagles Aquila chrysaetos from across eastern North America with four environmental predictors to generate monthly distribution models. We considered three model structures that assumed different amounts of individual variation in the functional relationship between predictors and habitat use and used k-fold cross-validation to compare model performance. Models accounting for individual variability in shape and smoothness of functional responses performed best. Eagles exhibited the least amount of individual variation in response to land cover variables during winter months, with most individuals more closely adhering to the population-level trend. During the summer months, eagles exhibited more substantial individual variation in shape and smoothness of the functional relationships, suggesting some need to account for individual variation in eagle habitat use for both inferential and predictive purposes, during this time of year. Because they allow users to blend flexible functions with random effects structures and are well-supported by a variety of software platforms, we believe that HGAMs provide a useful addition to the suite of analyses used for modeling habitat associations or predicting species distributions.

54 ENVIRONMENTAL SCIENCES↗

TH-C-BRD-05: Reducing Proton Beam Range Uncertainty with Patient-Specific CT HU to RSP Calibrations Based On Single-Detector Proton Radiography

Purpose: Beam range uncertainty in proton treatment comes primarily from converting the patient's X-ray CT (xCT) dataset to relative stopping power (RSP). Current practices use a single curve for this conversion, produced by a stoichiometric calibration based on tissue composition data for average, healthy, adult humans, but not for the individual in question. Proton radiographs produce water-equivalent path length (WEPL) maps, dependent on the RSP of tissues within the specific patient. This work investigates the use of such WEPL maps to optimize patient-specific calibration curves for reducing beam range uncertainty. Methods: The optimization procedure works on the principle of minimizing the difference between the known WEPL map, obtained from a proton radiograph, and a digitally-reconstructed WEPL map (DRWM) through an RSP dataset, by altering the calibration curve that is used to convert the xCT into an RSP dataset. DRWMs were produced with Plastimatch, an in-house developed software, and an optimization procedure was implemented in Matlab. Tests were made on a range of systems including simulated datasets with computed WEPL maps and phantoms (anthropomorphic and real biological tissue) with WEPL maps measured by single detector proton radiography. Results: For the simulated datasets, the optimizer showed excellent results. It was able to either completely eradicate or significantly reduce the root-mean-square-error (RMSE) in the WEPL for the homogeneous phantoms (to zero for individual materials or from 1.5% to 0.2% for the simultaneous optimization of multiple materials). For the heterogeneous phantom the RMSE was reduced from 1.9% to 0.3%. Conclusion: An optimization procedure has been designed to produce patient-specific calibration curves. Test results on a range of systems with different complexities and sizes have been promising for accurate beam range control in patients. This project was funded equally by the Engineering and Physical Sciences Research Council (UK) and Ion Beam Applications (Louvain-La-Neuve, Belgium)

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-J-103: Assessment of Liver Tumor Contrast for Radiation Therapy: Inter-Patient and Inter-Sequence Variability

Purpose: To determine the variation in tumor contrast between different MRI sequences and between patients for the purpose of MRI-based treatment planning. Methods: Multiple MRI scans of 11 patients with cancer(s) in the liver were included in this IRB-approved study. Imaging sequences consisted of T1W MRI, Contrast-Enhanced T1W MRI, T2W MRI, and T2*/T1W MRI. MRI images were acquired on a 1.5T GE Signa scanner with a four-channel torso coil. We calculated the tumor-to-tissue contrast to noise ratio (CNR) for each MR sequence by contouring the tumor and a region of interest (ROI) in a homogeneous region of the liver using the Eclipse treatment planning software. CNR was calculated (I-Tum-I-ROI)/SD-ROI, where I-Tum and I-ROI are the mean values of the tumor and the ROI respectively, and SD-ROI is the standard deviation of the ROI. The same tumor and ROI structures were used in all measurements for different MR sequences. Inter-patient Coefficient of variation (CV), and inter-sequence CV was determined. In addition, mean and standard deviation of CNR were calculated and compared between different MR sequences. Results: Our preliminary results showed large inter-patient CV (range: 37.7% to 88%) and inter-sequence CV (range 5.3% to 104.9%) of liver tumor CNR, indicating great variations in tumor CNR between MR sequences and between patients. Tumor CNR was found to be largest in CE-T1W (8.5±7.5), followed by T2W (4.2±2.4), T1W (3.4±2.2), and T2*/T1W (1.7±0.6) MR scans. The inter-patient CV of tumor CNR was also the largest in CE-T1W (88%), followed by T1W (64.3%), T1W (56.2%), and T2*/T1W (37.7) MR scans. Conclusion: Large inter-sequence and inter-patient variations were observed in liver tumor CNR. CE-T1W MR images on average provided the best tumor CNR. Efforts are needed to optimize tumor contrast and its consistency for MRI-based treatment planning of cancer in the liver. This project is supported by NIH grant: 1R21CA165384.

60 APPLIED LIFE SCIENCES↗

An interactive machine learning platform for analyzing multi-particle coincidence data from cold target recoil ion momentum spectroscopy

We present SCULPT (Supervised Clustering and Uncovering Latent Patterns with Training), a comprehensive software platform for analyzing tabulated high-dimensional multi-particle coincidence data from Cold Target Recoil Ion Momentum Spectroscopy (COLTRIMS) experiments. The software addresses critical challenges in modern momentum spectroscopy by integrating advanced machine learning techniques with physics-informed analysis in an interactive web-based environment. SCULPT implements uniform manifold approximation and projection for non-linear dimensionality reduction to reveal correlations in high-dimensional data. We also discuss potential extensions to deep autoencoders for feature learning and genetic programming for automated discovery of physically meaningful observables. A novel adaptive confidence scoring system provides quantitative reliability assessments by evaluating user-selected clustering quality metrics with predefined weights that reflect each metric’s robustness. The platform features configurable molecular profiles for different experimental systems, interactive visualization with selection tools, and comprehensive data filtering capabilities. Utilizing a subset of SCULPT’s capabilities, we analyze photo-double-ionization data measured using the COLTRIMS method for three-body dissociation of the D 2 O molecule, revealing distinct fragmentation channels and their correlations with physics parameters. The software’s modular architecture and web-based implementation make it accessible to the broader atomic and molecular physics community, significantly reducing the time required for complex multi-dimensional analyses. This opens the door to finding and isolating rare events exhibiting non-linear correlations on the fly during experimental measurements, which can help steer exploration and improve the efficiency of experiments.

Artificial neural networks↗

Nuclear Criticality Safety Integral Experiment Covariance Determination

Integral benchmarks for criticality safety and nuclear data validation require expensive uncertainty quantification studies. Commonly, the uncertainty quantification ignores correlations between experiments that share components. Experiments such as the TEX (Thermal/Epithermal eXperiments) campaigns consist of many shared parts, such as fuel, which create a strong correlation in their uncertainties. While these correlations are known to exist, they are often not estimated due to the complexity of such calculations. This paper describes a software package that uses an intuitive method of determining the covariance for each of the experimental components, providing a correlation matrix for each family of parts across the multiple cases examined within a benchmark. The code uses the TEX-HEU campaign as a proof of concept, and we show that the correlations can be calculated with information commonly found in ICSBEP (International Criticality Safety Benchmark Evaluation Project) benchmarks. The estimated covariances are used in χ 2 trending studies to evaluate their impact on nuclear data validation. Without covariances, χ 2 per degree of freedom was calculated as 2.203 and with covariances it was 1.179. The difference shows that omitting covariance information may cause overly pessimistic bias quantifications. The covariance determination code can be easily integrated into current benchmark evaluations as well as reevaluating legacy benchmark uncertainties. Uncertainty correlation calculations should become the baseline for criticality safety integral experiment benchmarks and can now be easily calculated with the described software package.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New compositional data on ancient mortars and plasters from Pompeii (Campania – Southern Italy): Archaeometric results and considerations about their time evolution

Highlights: • Mortar samples from Pompeii, with different constructive functions, were studied. • Characterization of the materials can be used for preparing compatible mortars. • Analogies and differences were highlighted to identify the constructive phases. • Preliminary statistic models were proposed to discriminate materials and constructive phases. Twenty-six samples of mortar used for various construction applications (joint mortars, floor mortars, filling mortars and plasters) were collected from different areas of the archaeological site of Pompeii (Campania - Sothern Italy). The mortar samples belong to various historical periods covering approximately 2000 years, from the 2nd century BC to the post excavation period (18–19th century). The samples were characterized employing Optical Microscopy (OM), X-ray Powder Diffraction (XRPD), X-ray Fluorescence (XRF), Electron Probe Micro Analysis (EPMA) and Raman Spectroscopy. Moreover, image analysis was carried out using JMicroVision software in order to determine the percentages of binder, macropores and aggregate, in terms of crushed ceramic fragments (cocciopesto), rock fragments and monocrystals. The application of these techniques allowed obtaining a complete chemical and minero-petrographic characterization of the samples, which may prove useful for preparing compatible repair mortars for future restoration works. The archaeometric study provided new data on the production technology of the mortars and the analogies and differences observed among the samples, enabled us to distinguish different constructive phases, thus confirming or rebutting the archaeological hypothesis on the dating of some samples. By combining compositional variables through the discriminant analysis, it was also possible to analyse the time evolution of the materials and to construct preliminary multivariate statistical models, helpful to identify the various typologies of mortars used in the different historical periods.

36 MATERIALS SCIENCE↗

SU-G-206-05: A Comparison of Head Phantoms Used for Dose Determination in Imaging Procedures

Purpose: To determine similarities and differences between various head phantoms that might be used for dose measurements in diagnostic imaging procedures. Methods: We chose four frequently used anthropomorphic head phantoms (SK-150, PBU-50, RS-240T and Alderson Rando), a computational patient phantom (Zubal) and the CTDI head phantom for comparison in our study. We did a CT scan of the head phantoms using the same protocol and compared their dimensions and CT numbers. The scan data was used to calculate dose values for each of the phantoms using EGSnrc Monte Carlo software. An .egsphant file was constructed to describe these phantoms using a Visual C++ program for DOSXYZnrc/EGSnrc simulation. The lens dose was calculated for a simulated CBCT scan using DOSXYZnrc/EGSnrc and the calculated doses were validated with measurements using Gafchromic film and an ionization chamber. Similar calculations and measurements were made for PA radiography to investigate the attenuation and backscatter differences between these phantoms. We used the Zubal phantom as the standard for comparison since it was developed based on a CT scan of a patient. Results: The lens dose for the Alderson Rando phantom is around 9% different than the Zubal phantom, while the lens dose for the PBU-50 phantom was about 50% higher, possibly because its skull thickness and the density of bone and soft tissue are lower than anthropometric values. The lens dose for the CTDI phantom is about 500% higher because of its totally different structure. The entrance dose profiles are similar for the five anthropomorphic phantoms, while that for the CTDI phantom was distinctly different. Conclusion: The CTDI and PBU-50 head phantoms have substantially larger lens dose estimates in CBCT. The other four head phantoms have similar entrance dose with backscatter hence should be preferred for dose measurement in imaging procedures of the head. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

The first clinical treatment with kilovoltage intrafraction monitoring (KIM): A real-time image guidance method

Purpose: Kilovoltage intrafraction monitoring (KIM) is a real-time image guidance method that uses widely available radiotherapy technology, i.e., a gantry-mounted x-ray imager. The authors report on the geometric and dosimetric results of the first patient treatment using KIM which occurred on September 16, 2014. Methods: KIM uses current and prior 2D x-ray images to estimate the 3D target position during cancer radiotherapy treatment delivery. KIM software was written to process kilovoltage (kV) images streamed from a standard C-arm linear accelerator with a gantry-mounted kV x-ray imaging system. A 120° pretreatment kV imaging arc was acquired to build the patient-specific 2D to 3D motion correlation. The kV imager was activated during the megavoltage (MV) treatment, a dual arc VMAT prostate treatment, to estimate the 3D prostate position in real-time. All necessary ethics, legal, and regulatory requirements were met for this clinical study. The quality assurance processes were completed and peer reviewed. Results: During treatment, a prostate position offset of nearly 3 mm in the posterior direction was observed with KIM. This position offset did not trigger a gating event. After the treatment, the prostate motion was independently measured using kV/MV triangulation, resulting in a mean difference of less than 0.6 mm and standard deviation of less than 0.6 mm in each direction. The accuracy of the marker segmentation was visually assessed during and after treatment and found to be performing well. During treatment, there were no interruptions due to performance of the KIM software. Conclusions: For the first time, KIM has been used for real-time image guidance during cancer radiotherapy. The measured accuracy and precision were both submillimeter for the first treatment fraction. This clinical translational research milestone paves the way for the broad implementation of real-time image guidance to facilitate the detection and correction of geometric and dosimetric errors, and resultant improved clinical outcomes, in cancer radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-478: Effect of Deconvolution in Analysis of Mega Voltage Photon Beam Profiles

Purpose: To study and compare the penumbra of 6 MV and 15 MV photon beam profiles after deconvoluting different volume ionization chambers. Methods: 0.125cc Semi-Flex chamber, Markus Chamber and PTW Farmer chamber were used to measure the in-plane and cross-plane profiles at 5 cm depth for 6 MV and 15 MV photons. The profiles were measured for various field sizes starting from 2×2 cm till 30×30 cm. PTW TBA scan software was used for the measurements and the “deconvolution” functionality in the software was used to remove the volume averaging effect due to finite volume of the chamber along lateral and longitudinal directions for all the ionization chambers. The predicted true profile was compared and the change in penumbra before and after deconvolution was studied. Results: After deconvoluting the penumbra decreased by 1 mm for field sizes ranging from 2 × 2 cm till 20 x20 cm. This is observed for along both lateral and longitudinal directions. However for field sizes from 20 × 20 till 30 ×30 cm the difference in penumbra was around 1.2 till 1.8 mm. This was observed for both 6 MV and 15 MV photon beams. The penumbra was always lesser in the deconvoluted profiles for all the ionization chambers involved in the study. The variation in difference in penumbral values were in the order of 0.1 till 0.3 mm between the deconvoluted profile along lateral and longitudinal directions for all the chambers under study. Deconvolution of the profiles along longitudinal direction for Farmer chamber was not good and is not comparable with other deconvoluted profiles. Conclusion: The results of the deconvoluted profiles for 0.125cc and Markus chamber was comparable and the deconvolution functionality can be used to overcome the volume averaging effect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

File format for normalizing radiological concentration exposure rate and dose rate data for the effects of radioactive decay and weathering processes

This report specifies the electronic file format that was agreed upon to be used as the file format for normalized radiological data produced by the software tool developed under this TI project. The NA-84 Technology Integration (TI) Program project (SNL17-CM-635, Normalizing Radiological Data for Analysis and Integration into Models) investigators held a teleconference on December 7, 2017 to discuss the tasks to be completed under the TI program project. During this teleconference, the TI project investigators determined that the comma-separated values (CSV) file format is the most suitable file format for the normalized radiological data that will be outputted from the normalizing tool developed under this TI project. The CSV file format was selected because it provides the requisite flexibility to manage different types of radiological data (i.e., activity concentration, exposure rate, dose rate) from other sources [e.g., Radiological Assessment and Monitoring System (RAMS), Aerial Measuring System (AMS), Monitoring and Sampling). The CSV file format also is suitable for the file format of the normalized radiological data because this normalized data can then be ingested by other software [e.g., RAMS, Visual Sampling Plan (VSP)] used by the NA-84’s Consequence Management Program.

97 MATHEMATICS AND COMPUTING↗

Providing performance portable numerics for Intel GPUs

Summary With discrete Intel GPUs entering the high‐performance computing landscape, there is an urgent need for production‐ready software stacks for these platforms. In this article, we report how we enable the Ginkgo math library to execute on Intel GPUs by developing a kernel backed based on the DPC++ programming environment. We discuss conceptual differences between the CUDA and DPC++ programming models and describe workflows for simplified code conversion. We evaluate the performance of basic and advanced sparse linear algebra routines available in Ginkgo's DPC++ backend in the hardware‐specific performance bounds and compare against routines providing the same functionality that ship with Intel's oneMKL vendor library.

97 MATHEMATICS AND COMPUTING↗

Using synchrotron X-ray phase-contrast micro-computed tomography to study tissue damage by laser irradiation: STUDY TISSUE DAMAGE BY LASER IRRADIATION

Background and Objective: The aim of this study was to determine if X-ray micro-computed tomography could be used to locate and characterize tissue damage caused by laser irradiation and to describe its advantages over classical histology for this application. Study Design/Materials and Methods: A surgical CO2 laser, operated in single pulse mode (100 milliseconds) at different power settings, was used to ablate different types of cadaveric animal tissues. Tissue samples were then harvested and imaged with synchrotron X-ray phasecontrast and micro-computed tomography to generate stacks of virtual sections of the tissues. Subsequently, Fiji (ImageJ) software was used to locate tissue damage, then to quantify volumes of laser ablation cones and thermal coagulation damage from 3D renderings of tissue image stacks. Visual comparisons of tissue structures in X-ray images with those visible by classic light microscopy histology were made. Results: We demonstrated that micro-computed tomography could be used to rapidly identify areas of surgical laser ablation, vacuolization, carbonization, and thermally coagulated tissue. Quantification and comparison of the ablation crater, which represents the volume of ablated tissue, and the thermal coagulation zone volumeswere performed faster than we could by classical histology. We demonstrated that these procedures can be performed on fresh hydrated and non-sectioned plastic embedded tissue. Conclusion: We demonstrated that the application of non-destructive micro-computed tomography to the visualization and analysis of laser induced tissue damage without tissue sectioning is possible. This will improve evaluation of new surgical lasers and their corresponding effect on tissues.

Ablation↗

MatRIS: Addressing the Challenges for Portability and Heterogeneity Using Tasking for Matrix Decomposition (Cholesky)

The ubiquitous in-node heterogeneity of HPC and cloud computing platforms makes software portability and performance optimization extremely challenging. Described here, the MatRIS multilevel math library abstraction framework employs tasking to alleviate these difficulties. MatRIS includes the IRIS task-based runtime on the bottom level and exposes different layers of abstraction to render algorithms architecturally agnostic. MatRIS ensures the decomposition and creation of tasks that represent the necessary encapsulation of the optimized kernels from both vendor and open-source math libraries. Once built, MatRIS can select different combinations of accelerators at runtime, making it portable even on diverse heterogeneous architectures. By leveraging the IRIS runtime’s features for managing heterogeneity, MatRIS deploys algorithms that remove the need to specify orchestration and data transfer. This study describes how the serial task abstraction of a tiled Cholesky factorization is made portable and scalable in the case of multi-device and multi-vendor heterogeneity on a node with NVIDIA and AMD GPUs by using MatRIS. First, we demonstrate that Cholesky in MatRIS provides multi-GPU scalability that offers competitive performance versus cuSolverMG. Then, we present the challenges and opportunities for heterogeneous execution.

Monil, M. A. H.↗

Calcium Treatment for FeSi-killed Fe-13 Pct Cr Stainless Steel with Various Top Slag Compositions

Calcium treatment of Fe-13 pct Cr stainless steel, with inclusion modification as its main purpose, was evaluated on a laboratory scale. The stability diagram of Ca-Al was obtained using the FactSage software and could be divided into three parts based on the [Al] content: the ultra-low-Al region, the low-Al region, and the medium-high-Al region. Each of these regions required different amounts of calcium for inclusion modification. The ferrosilicon deoxidation product could be modified into low melting temperature inclusions by a CaO-SiO{sub 2} top slag in the ultra-low-Al region ([Al] content less than 40 ppm). Calcium treatment was necessary to modify the ferrosilicon deoxidation product into low melting temperature inclusions in the low-Al region ([Al] content from 40 to 100 ppm) for the CaO-SiO{sub 2}-Al{sub 2}O{sub 3} top slag. Calcium addition has a “liquid window” where adding calcium can accelerate inclusion modification. Adding calcium for 15 and 30 minutes resulted in complete modification times of 45 and 60 minutes, respectively, which indicates that early calcium treatment can produce plastic inclusions sooner. The relationship between the steel and inclusion content was determined by fitting the experimental data in the low-Al region. An appropriate range of T.Ca/T.O (total calcium content/total oxygen content) for inclusion modification is 0.99 to 1.44.

36 MATERIALS SCIENCE↗

Dynamic analysis environment for nuclear forensic analyses

We report a Dynamic Analysis Environment (DAE) software package is introduced to facilitate group inclusion/exclusion method testing, evaluation and comparison for pre-detonation nuclear forensics applications. Employing DAE, the multivariate signatures of a questioned material can be compared to the signatures for different, known groups, enabling the linking of the questioned material to its potential process, location, or fabrication facility. Advantages of using DAE for group inclusion/exclusion include built-in query tools for retrieving data of interest from a database, the recording and documentation of all analysis steps, a clear visualization of the analysis steps intelligible to a non-expert, and the ability to integrate analysis tools developed in different programming languages. Two group inclusion/exclusion methods are implemented in DAE: principal component analysis, a parametric feature extraction method, and k nearest neighbors, a nonparametric pattern recognition method. Spent Fuel Isotopic Composition (SFCOMPO), an open source international database of isotopic compositions for spent nuclear fuels (SNF) from 14 reactors, is used to construct PCA and KNN models for known reactor groups, and 20 simulated SNF samples are utilized in evaluating the performance of these group inclusion/exclusion models. For all 20 simulated samples, PCA in conjunction with the Q statistic correctly excludes a large percentage of reactor groups and correctly includes the true reactor of origination. As a result, employing KNN, 14 of the 20 simulated samples are classified to their true reactor of origination.

97 MATHEMATICS AND COMPUTING↗

Multispectrum analysis of air-broadened spectra in the ν 3 Q branch of 12CH4

In this paper, we report experimental measurements of spectral line shape parameters (air-broadened width, shift, and line mixing coefficients) for several transitions in the ν 3 Q branch of methane in the 3000–3023 cm -1 region. 13 high-resolution, room temperature laboratory spectra of pure methane and air-broadened methane recorded with two different Fourier transform spectrometers are fitted. 12 of these spectra were acquired at 0.01 cm -1 resolution with the McMath-Pierce FTS at the National Solar Observatory on Kitt Peak, and one higher-resolution (~0.0011 cm-1) low pressure methane spectrum was obtained with the Bruker IFS-120HR FTS at the Pacific Northwest National Laboratory, in Richland, Washington. All the spectra were obtained using high purity natural samples of CH 4 and lean mixtures of the same natural CH 4 in dry air. For the 12 spectra recorded at Kitt Peak, three different absorption cells (L= 5, 25 and 150 cm) were used while the methane spectrum at PNNL was obtained using a 19.95 cm long absorption cell. For the analysis, an interactive multispectrum nonlinear least squares fitting software was employed where all the 13 spectra were fitted simultaneously. An accurate and self-consistent set of line parameters were determined by constraining a few of those for severely blended transitions. Line mixing was measured for fourteen transition pairs for the CH 4 -air collision system. Lastly, a constant speed dependence parameter, consistent with measured speed dependence values obtained in other methane bands, was applied to all the transitions included in the fitted region. The present measurements are compared to values reported in the literature.

12CH4↗

Non-Adiabatic Excited State Molecular Dynamics Methodologies: comparison and convergence

Direct atomistic simulation of nonadiabatic molecular dynamics is a challenging goal that allows important insights into fundamental physical phenomena. A variety of frameworks, ranging from fully quantum treatment of nuclei to semiclassical and mixed quantum–classical approaches, were developed. These algorithms are then coupled to specific electronic structure techniques. Such diversity and lack of standardized implementation make it difficult to compare the performance of different methodologies when treating realistic systems. Here, we compare three popular methods for large chromophores: Ehrenfest, surface hopping, and multiconfigurational Ehrenfest with ab initio multiple cloning (MCE-AIMC). These approaches are implemented in the NEXMD software, which features a common computational chemistry model. The resulting comparisons reveal the method performance for population relaxation and coherent vibronic dynamics. Finally, we study the numerical convergence of MCE-AIMC algorithms by considering the number of trajectories, cloning thresholds, and Gaussian wavepacket width. Our results provide helpful reference data for selecting an optimal methodology for simulating excited-state molecular dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Active synchronization between two different chaotic dynamical system

In this paper we investigate on the synchronization problem between two different chaotic dynamical system based on the Lyapunov stability theorem by using nonlinear control functions. Active control schemes are used for synchronization Liu system as drive and Rossler system as response. Numerical simulation by using Maple software are used to show effectiveness of the proposed schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗