At least 1,243 records · Page 69

Enhancing grid reliability and resilience through novel DER control, total situational awareness and integrated distribution-transmission representation

High penetration of distributed energy resources (DERs) can lead to overvoltage and thermal violations, miscoordination of protection devices and potential adverse control interactions. The challenges are exacerbated by a lack of operator situational awareness of behind-the-meter DERs, and T&D interactions. Furthermore, the large attack surface of a DER environment creates significant cyber security challenges. The motivation is to address these barriers. The main goal is to enable extreme levels of DERs in distribution systems while simultaneously enhancing their reliability and resiliency. This is achieved by a data-driven approach for operation, planning and control of distribution systems with total situational awareness and real-time DER control enabled by a network of edge intelligent devices, a cloud-based analytical platform, and secure communications.

14 SOLAR ENERGY↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond Timing

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specifc integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verifed using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

Disconnected Quark Loop Contributions to Nucleon Structure

We calculate the disconnected contribution to isoscalar nucleon charges for scalar, axial and tensor channels of light and strange quarks. The calculation has been done with the Clover valence quarks on the MILC N f = 2+1+1 HISQ lattices whose light quark masses corresponding to the pion masses of 305MeV and 217MeV at a ≈ 0:12fm and 312MeV at a ≈ 0:09fm. All-modeaveraging technique is used for the evaluation two-point functions. Disconnected quark loops are estimated by using the truncated solver method with Gaussian random noise sources. Contamination from the excited states is removed by fitting the results of various source-sink separations and operator insertions to the formula including up to the first excited state, simultaneously.

74 ATOMIC AND MOLECULAR PHYSICS↗

sashevis (b1)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashemfr (b1)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashenir (b1)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashenirlowsun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashevislowsun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashevishisun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashenirhisun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

Precision full-wave rectifier

Simplified circuit uses one operational amplifier and two precision resistors. The amplifier is operated open loop for switching and closed loop for linear gain, both simultaneously.

Deboo, G. J.↗

Amplitude and polarization asymmetries in a ring laser

Asymmetric amplitude effects between the oppositely directed traveling waves in a He-Ne ring laser are analyzed both theoretically and experimentally. These effects make it possible to detect angular orientations of an inner-cavity bar with respect to the plane of the ring cavity. The amplitude asymmetries occur when a birefringent bar is placed in the three-mirror ring cavity, and an axial magnetic field is applied to the active medium. A simplified theoretical analysis is performed by using a first order perturbation theory to derive an expression for the polarization of the active medium, and a set of self-consistent equations are derived to predict threshold conditions. Polarization asymmetries between the oppositely directed waves are also predicted. Amplitude asymmetries similar in nature to those predicted at threshold occur when the laser is operating in 12-15 free-running modes, and polarization asymmetry occurs simultaneously.

Campbell, L. L.↗

Miniature pressure valve for on-board calibration of pressure transducers.

This paper describes the development and testing of a miniature one-pole, three-position pressure valve and actuation mechanism. This valve was designed primarily for installation with a pressure transducer directly in a wind-tunnel model, thereby reducing lag time effects resulting from long connecting tubes to the transducer. This valve provides for the in-situ calibration of the transducer during testing by providing one position for transducer zero, a second position for a known calibrate pressure, and a third position for measurement of the unknown test pressure. The valve is driven from the spring loaded test pressure position to the zero and calibrate positions by a pneumatically operated dual-piston yoke assembly. Large numbers of transducers can be simultaneously calibrated from a remote location in a matter of seconds.

Rollins, G. N.↗

Tse computers

Tse computers have the potential of operating four or five orders of magnitude faster than present digital computers. The computers of the new design use binary images as their basic computational entity. The word 'tse' is the transliteration of the Chinese word for 'pictograph character.' Tse computers are large collections of devices that perform logical operations on binary images. The operations on binary images are to be performed over the entire image simultaneously.

Strong, J. P., III↗

The Nimbus F Random Access Measurement System /RAMS/

In 1974, the Random Access Measurement System (RAMS) will be launched aboard the Nimbus F satellite as part of the Tropical Wind, Energy Conversion, and Reference Level Experiment (TWERLE). This paper describes operation and performance of the RAMS instrument, which will provide a means of tracking and collecting data from a large number of instrumented platforms. In operation, the RAMS will perform satellite onboard processing of up to eight simultaneous platform transmissions, following search and detection of the randomly received platform transmissions in a compressed-time expanded-frequency domain. The processed data is stored aboard the satellite for readout every 108 minutes (orbital period), and platform locational coordinates and/or velocity components are determined in a central ground data processing facility.

Coates, J. L.↗

A multichannel physiological data/voice telemetry system

A seven channel physiological telemetry system was designed, constructed, and tested for a space environment to transfer physiological and voice information to and from an astronaut. Three ECG leads were monitored simultaneously, and two-way voice communication was achieved. The portable unit operated properly under ground based station (GBS) control. The major design problem was associated with the constraints of a wide bandwidth FM transmitter with crystal control combined with the tri-state logic format used. However, by using an ''indirect FM'' scheme and incorporating additional waveshaping circuits at the GBS, proper operation of the system was obtained. In the present form, the telemetry system has capability for seven channels of low level (2.5 mv peak maximum) physiological signals with bandwidths between 0.03 Hz and 100 Hz. Additional signal conditioning and modification of the instrumentation amplifier gains are required for other signals.

Portnoy, W. M.↗

Sail intelligent terminal evaluation

Engineering assessments, recommendations, and equipment necessary to solve the operational problems are described, and operational flexibility of the intelligent terminal facility are extended. The following capabilities were considered: (1) the operation of at least two D/D stations and one remote graphics terminal simultaneously; (2) the capability to run plotter, AIDS and FORTRAN programs simultaneously; (3) simultaneous use of system utility routines of D/D stations and remote graphics terminal; (4) the capability to provide large volume hardcopy of data and graphics; and (5) the capability to eliminate or at least ease the current operation/programming problems with related labor costs. The overall intelligent terminal development, and plans guiding the analysis and equipment acquisitions were studied, and the assessments and analyses performed are also summarized.

Pruitt, J. L.↗