Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Regional variations in the magnitude of heiligenschein and causal connections, part O

A preliminary quantitative analysis was conducted of four frames exposed by the Apollo 15 metric camera. Two of the frames show the zero-phase surge on maria and the other two show the surge on terrae. It was found that the curves resulting from brightness plotted as a function of phase angle, differ markedly according to which terrain type is involved. The magnitude of the heiligenschein was found to be significantly greater for the maria than for the terrae.

Wildey, R. L.↗

Height-depth ratios of lunar and terrestrial craters.

Quantitative analysis of Gilbert's (1893) observation regarding the surface geometry of lunar craters and terrestrial calderas. Topographic measurements were made using the ratio of exterior rim height to interior crater depth, and then extended to other types of crater. The morphometric data obtained as well as those presented elsewhere (Murray et al., 1970; Guest and Murray, 1969) verify Gilbert's contention that terrestrial calderas and most rimmed lunar craters are entirely unrelated phenomena. Auxiliary characteristics previously interpreted in terms of primary volcanic cratering on the moon are either of nonendogenic origin or are secondary endogenic features superposed on initial impact landforms (Pike, 1967).

Pike, R. J.↗

Cooperation of charges in photosynthetic O2 evolution. II - Damping of flash yield oscillation, deactivation.

A quantitative analysis is made of a linear four-step model for photosynthetic molecular oxygen evolution in which each photochemical trapping center or an associated enzyme cycles through five oxidation states. Based on data obtained with isolated chloroplasts, a number of aspects were considered, including the two perturbations which damp the oscillation of the oxygen flash yield in a flash sequence. The kinetics and the mechanism of deactivation was another aspect investigated.

Forbush, B.↗

Effects of rotating flows on combustion and jet noise.

Experimental investigations of combustion in rotating (swirling) flow have shown that the mixing and combustion processes were accelerated, flame length and noise levels significantly decreased, and flame stability increased relative to that obtained without rotation. Unsteady burning accompanied by a pulsating flame, violent fluctuating jet, and intense noise present in straight flow burning were not present in rotating flow burning. Correlations between theory and experiment show good agreement. Such effects due to rotating flows could lead to suppressing jet noise, improving combustion, reducing pollution, and decreasing aircraft engine size. Quantitative analysis of the aero-acoustic relationship and noise source characteristics are needed.-

Schwartz, I. R.↗

Counter tube window and X-ray fluorescence analyzer study

A study was performed to determine the best design tube window and X-ray fluorescence analyzer for quantitative analysis of Venusian dust and condensates. The principal objective of the project was to develop the best counter tube window geometry for the sensing element of the instrument. This included formulation of a mathematical model of the window and optimization of its parameters. The proposed detector and instrument has several important features. The instrument will perform a near real-time analysis of dust in the Venusian atmosphere, and is capable of measuring dust layers less than 1 micron thick. In addition, wide dynamic measurement range will be provided to compensate for extreme variations in count rates. An integral pulse-height analyzer and memory accumulate data and read out spectra for detail computer analysis on the ground.

Hertel, R.↗

ERIM progress report on use of ERTS-1 data: Summary report of work on ten tasks

The author has identified the following significant results. Several of the tasks have produced significant results which are summarized: (1) Absolute water depth can be calculated from a ratio of signals from bands MSS 4 and MSS 5. (2) A 13 category terrain feature classification map of Yellowstone National Park has been produced using supervised pattern recognition techniques. (3) ERTS-1 data has been shown to provide a detection and monitoring capability for a number of water quality problems associated with off-shore ocean dumping sites and inland lakes. (4) A corrected ratio of bands MSS-5 and MSS-7 signals has been formed. (5) A concise format has been devised for storing the ratio signatures of geologic rock and mineral materials determined from laboratory reflectance spectra. (6) Results of work in information extraction demonstrate: signal variability exists among ERTS-1 detectors in any one spectral band that will impact users doing quantitative analysis on successive ERTS-1 images; a newly developed computer-aided procedure for correlating ERTS-1 pixels to ground features; the strong influence of atmospheric effects in ERTS-1 data; and area estimation accuracies are better using the ERIM proportion estimation algorithm than for conventional recognition techniques.

Thomson, F. J.↗

A user's guide to the Mariner 9 television reduced data record

The Mariner 9 television experiment used two cameras to photograph Mars from an orbiting spacecraft. For quantitative analysis of the image data transmitted to earth, the pictures were processed by digital computer to remove camera-induced distortions. The removal process was performed by the JPL Image Processing Laboratory (IPL) using calibration data measured during prelaunch testing of the cameras. The Reduced Data Record (RDR) is the set of data which results from the distortion-removal, or decalibration, process. The principal elements of the RDR are numerical data on magnetic tape and photographic data. Numerical data are the result of correcting for geometric and photometric distortions and residual-image effects. Photographic data are reproduced on negative and positive transparency films, strip contact and enlargement prints, and microfiche positive transparency film. The photographic data consist of two versions of each TV frame created by applying two special enhancement processes to the numerical data.

Seidman, J. B.↗

The design, construction and testing of the optics for a 147-cm-aperture telescope

Geodetic optics research for the Air Force Cambridge Research Laboratories (AFCRL) is described. The work consisted mainly of the fabrication of the optical components for a telescope with a 152-cm-diam (60-in.) primary mirror masked down to 147-cm-diam for use by the AFCRL for a lunar ranging experiment. Among the achievements of this contract were the following: completion of the primary and secondary mirrors for a high-quality 147-cm-diam telescope system in eight months from the start of edging the primary; manufacture and testing of a unique center mount for the primary according to an AFCRL design that allowed for a thin-edged and therefore less-massive mirror; and development of a quantitative analysis of the wire test for calculating the departure of the mirror figure from the design figure quickly and accurately after each polishing step. This analysis method in conjunction with a knowledge of polishing rates for given weights and diameters of tools, mirror, and polishing materials should considerably reduce the polishing time required for future large mirrors.

Buchroeder, R. A.↗

Investigation of the sensitivity of ionization-type vacuum gauges

A quantitative analysis of a large and representative sample of available data has been made to determine the best criteria for predicting the relative sensitivities of ionization-type vacuum gauges to different gases. The molecular property of the gas that correlates best with relative sensitivity is the ionization cross section (eV). For high-pressure ionization gauges, a cross section evaluated at 2/3 of the accelerating potential of the gauge is the best choice. For Bayard-Alpert and triode gauges, any of three choices are of approximately equal value. These are 100 eV cross section values, maximum cross section value for each gas, and a cross section evaluated at 2/3 of the accelerating potential for each gauge. For the Alphatron gauge, cross section values in the range 5000-10,000 eV provide the best correlation.

Holanda, R.↗

Laser data links for communication satellites

Laser data relays potentially offer continuous 1 Gb/sec bandwidths, drastically increasing low-altitude satellite data collection capacity over present store-and-dump techniques. Availability of the laser link as a reliable alternative, operating within conventional low-altitude communication subsystem weight and power allocations, will create customer pressure for adoption. Major communication relay system impacts are discussed including reliability, mechanical design, attitude control, on-board data handling, contamination control, and traffic-net management. Interface parameters which drive the fundamental relay satellite design concepts are discussed, and conditions requiring early quantitative analysis are identified.

Ohern, W. L.↗

Correlation of 1.65 and 2.15 micron airglow emissions

The intense infrared airglow is due primarily to vibration-rotation bands of the OH molecule. This airglow has been observed with a 24-in. scanning photometer at two wavelengths. Narrow-band interference filters are used to limit observations to the (9,7) band at 2.15 microns and the (4,2) and (5,3) bands at 1.65 microns. If OH emission results from creation of the excited OH molecule in the v = 9 vibrational state and subsequent cascading through lower vibrational levels, the 1.65 and 2.15 micron radiation will be well correlated in space and time. However, if several mechanisms are involved in producing OH in a variety of initial excitation levels, there is no reason to expect good correlation. Sky maps obtained simultaneously at 1.65 and 2.15 microns show strongly correlated intensity fluctuations. Quantitative analysis of these maps and other investigations of smaller areas of the sky yield correlation coefficients typically in excess of 0.8.

Kieffaber, L. M.↗

Pulsar fluctuation spectra and the generalized drifting-subpulse phenomenon. II

Pulsar observations at meter wavelengths have been analyzed to investigate pulse-to-pulse variations and to identify regions of the pulse profile which display distinct statistical properties. Fluctuation spectra of eight recently discovered pulsars are presented along with a description of the drifting-subpulse phenomenon in several objects with quasiperiodic responses in their fluctuation spectra. A quantitative analysis of the drifting-subpulse phenomenon in PSR 0031-07 and PSR 0809+74 is given which emphasizes the broad-band nature of the phenomenon. A summary of the memory exhibited by pulsars with time scales of about 50 periods is given.

Backer, D. C.↗

Development of a high-resolution automatic digital (urine/electrolytes) flow volume and rate measurement system of miniature size

To aid in the quantitative analysis of man's physiological rhythms, a flowmeter to measure circadian patterns of electrolyte excretion during various environmental stresses was developed. One initial flowmeter was designed and fabricated, the sensor of which is the approximate size of a wristwatch. The detector section includes a special type of dielectric integrating type sensor which automatically controls, activates, and deactivates the flow sensor data output by determining the presence or absence of fluid flow in the system, including operation under zero-G conditions. The detector also provides qualitative data on the composition of the fluid. A compact electronic system was developed to indicate flow rate as well as total volume per release or the cumulative volume of several releases in digital/analog forms suitable for readout or telemetry. A suitable data readout instrument is also provided. Calibration and statistical analyses of the performance functions required of the flowmeter were also conducted.

Liu, F. F.↗