Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power systems operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.

black start↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables: Preprint

This paper performs a transient stability study of a real-world microgrid with 100% renewables to fully understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, the full-scale electromagnetic transient modeling of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid, which gives good references for the field deployment in terms of inverter configuration and coordination as well as the capabilities of black start and unplanned islanding.

100% renewable microgrid↗

The Ion Propulsion System on NASA's Space Technology 4/Champollion Comet Rendezvous Mission

The ST4/Champollion mission is designed to rendezvous with and land on the comet Tempel 1 and return data from the first-ever sampling of a comet surface. Ion propulsion is an enabling technology for this mission. The ion propulsion system on ST4 consists of three ion engines each essentially identical to the single engine that flew on the DS1 spacecraft. The ST4 propulsion system will operate at a maximum input power of 7.5 kW (3.4 times greater than that demonstrated on DS1), will produce a maximum thrust of 276 mN, and will provide a total (Delta)V of 11.4 km/s. To accomplish this the propulsion system will carry 385 kg of xenon. All three engines will be operated simultaneously for the first 168 days of the mission. The nominal mission requires that each engine be capable of processing 118 kg. If one engine fails after 168 days, the remaining two engines can perform the mission, but must be capable of processing 160 kg of xenon, or twice the original thruster design requirement. Detailed analyses of the thruster wear-out failure modes coupled with experience from long-duration engine tests indicate that the thrusters have a high probability of meeting the 160-kg throughput requirement.

Brophy, John R.↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.

black start↗

System Study: High-Pressure Safety Injection 1998-2020

This report presents an unreliability evaluation of the high-pressure safety injection system (HPSI) at 69 U.S. commercial nuclear reactors. Demand, run hours, and failure data from calendar years 1998–2020 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPSI results.

99 GENERAL AND MISCELLANEOUS↗

System Study: Reactor Core Isolation Cooling 1998-2020

This report presents an unreliability evaluation of the reactor core isolation cooling (RCIC) system at 31 U.S. commercial boiling water reactors. Demand, run hours, and failure data from calendar years 1998 through 2020 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the RCIC results.

99 GENERAL AND MISCELLANEOUS↗

System Study: Emergency Power System 1998–2018

This report presents an unreliability evaluation of the emergency power system (EPS) at 104 U.S. commercial nuclear power plants. Demand, run hours, and failure data from 1998 through 2018 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the EPS results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fluid-kinetic modeling of a high power density radio frequency inductively coupled positive hydrogen ion source

High power density radio-frequency (RF) inductively coupled positive ion sources are attractive candidates for next-generation neutral beam injection (NBI) systems, where higher injected power and longer pulse lengths are desired without sacrificing source reliability. Operating at absorbed power densities of order $\gt 1~\mathrm{W\,cm}^{-3}$ places these sources in a regime with stronger gas heating, higher dissociation, and non-Maxwellian electron energy distributions. The Large Uniform Plasma for Ionizing Neutrals (LUPIN) is an RF inductively coupled plasma source designed to explore this high power density regime and to provide guidance for a positive ion source upgrade for the DIII-D NBI system. LUPIN is designed to operate at up to 20 kW of RF power at 2 MHz, coupling energy through a cylindrical quartz vessel to achieve target ion current densities of $2100\,\mathrm{A\,m}^{-2}$ . This paper presents fluid-kinetic modeling of LUPIN using the hybrid plasma equipment model where electrons are treated kinetically, and the simulations reveal that electron energy distribution function transitions from nearly Maxwellian in the core to bi-Maxwellian towards the edge. Parametric simulations investigate the effects of RF power, gas pressure, and frequency on plasma density, ion flux, and uniformity. Parametric sweeps reveal that increasing power shifts the primary ionization channel from molecular to atomic with diminishing flux gains due to skin-depth contraction and gas rarefaction. Higher frequency localizes heating and increases $\mathrm{H}_2^+$ and $\mathrm{H}_3^+$ delivery to the grid, while elevated pressure boosts ionization yet hinders ion transport due to increase in collisionality.

inductively coupled plasma↗

Coherent Frequency Reference System for the NASA Deep Space Network

The NASA Deep Space Network (DSN) requires state-of-the-art frequency references that are derived and distributed from very stable atomic frequency standards. A new Frequency Reference System (FRS) and Frequency Reference Distribution System (FRD) have been developed, which together replace the previous Coherent Reference Generator System (CRG). The FRS and FRD each provide new capabilities that significantly improve operability and reliability. The FRS allows for selection and switching between frequency standards, a flywheel capability (to avoid interruptions when switching frequency standards), and a frequency synthesis system (to generate standardized 5-, 10-, and 100-MHz reference signals). The FRS is powered by redundant, specially filtered, and sustainable power systems and includes a monitor and control capability for station operations to interact and control the frequency-standard selection process. The FRD receives the standardized 5-, 10-, and 100-MHz reference signals and distributes signals to distribution amplifiers in a fan out fashion to dozens of DSN users that require the highly stable reference signals. The FRD is also powered by redundant, specially filtered, and sustainable power systems. The new DSN Frequency Distribution System, which consists of the FRS and FRD systems described here, is central to all operational activities of the NASA DSN. The frequency generation and distribution system provides ultra-stable, coherent, and very low phase-noise references at 5, l0, and 100 MHz to between 60 and 100 separate users at each Deep Space Communications Complex.

Tucker, Blake C.↗

Data-Driven Distribution System Coordinated PV Inverter Control Using Deep Reinforcement Learning

The deployment of distributed solar photovoltaic (PV) systems has increased consistently over the past decades. High penetrations of PVs could cause a series of adverse grid impacts, such as voltage violations. The recent development of smart inverter technologies rises the incentives of developing PV control solutions that regulate the inverter output power and seeking the optimization on system operational objectives. This paper proposes a data-driven control solution based on deep reinforcement learning (DRL) to optimize PV inverters for voltage regulation. The proposed solution can minimize PV real power curtailment while maintaining network voltage at an acceptable range. Comparison results between the proposed DRL control algorithms with deep deterministic policy gradient (DDPG) and volt-var control on a real feeder in west Colorado highlight the advantage of the proposed framework in controlling the system voltage while minimizing the PV real power curtailment.

deep reinforcement learning↗

Flexible Service Contracting for Risk Management within Integrated Transmission and Distribution Systems

The general objective of our project has been to investigate the ability of Independent Distribution System Operators (IDSOs), functioning as linkage agents for Integrated Transmission and Distribution (ITD) systems, to facilitate the flexible availability and usage of reserve in support of ITD system operations. This general objective is in accordance with Order 2222 of the U.S. Federal Energy Regulatory Commission (FERC), titled “Participation of Distributed Energy Resource Aggregations in Markets Operated by Regional Transmission Organizations and Independent System Operators”. The Final Rule for FERC Order 2222 was issued on September 17, 2020. The primary contribution of our project is that we have formulated an innovative energy management Transactive Energy Design (TES) approach for ITD systems that provides promising support for our project objective. Specifically, we have developed a new type of IDSO-managed TES design for distribution system operations, as well as new types of swing contracts permitting IDSOs to participate in transmission system operations as providers of reserve harnessed from distribution system resources in return for appropriate compensation. Together, these design elements constitute a scalable market-based approach facilitating efficient reserve procurement for ITD system operations from a fuller range of power resources. The efficacy of our approach has been demonstrated by means of detailed conceptual analyses as well as test case simulations. To implement the latter, we have developed the ITD TES Platform V2.0, a computational platform that permits the modeling and software implementation of ITD system operations over time. The Electric Reliability Council of Texas (ERCOT) energy region has been used as the empirical anchor for the development of this platform. Our conceptual and test-case work has been reported in a Wiley/IEEE Press book, two refereed book chapters, and seven refereed journal articles. The key components comprising the ITD TES Platform V2.0 have been released as documented open-source software at online GitHub repositories.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar, Wind, and Load Forecasting Dataset for MISO, NYISO, and SPP Balancing Areas

The Performance-based Energy Resource Feedback, Optimization, and Risk Management (PERFORM) program is an initiative intended to foster "a fundamental shift in grid management rooted in an understanding of asset risk and system risk" (ARPA-E 2020). Launched by the Advanced Research Projects Agency-Energy (ARPA-E), the program supports efforts to incorporate uncertainty in electric power decision making. In support of PERFORM, the National Renewable Energy Laboratory (NREL) has produced a set of time-coincident forecasts of solar, wind, and load profiles. As part of Phase I of the PERFORM effort, NREL created a dataset that consists of one year of time-coincident load, wind, and solar actuals and probabilistic forecasts based on data from the Electric Reliability Council of Texas (ERCOT) (Bryce et al. 2023). In Phase II, NREL developed similar datasets for three other U.S. Independent System Operators (ISO): the Midcontinent Independent System Operator (MISO), the New York Independent System Operator (NYISO), and the Southwest Power Pool (SPP).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stakeholder Engagement Review Meeting Summary Report

Sustainability in the context of the Light Water Reactor Sustainability (LWRS) Program is the ability to maintain the safe and economic operation of the existing fleet of nuclear power plants now and in the future. It has two objectives with respect to long-term operations: (1) to provide science and technology-based solutions to industry to safely enhance the economical operation of power reactors; and (2) to manage the aging of systems, structures, and components (SSCs) so that nuclear power plants can continue to operate safely and cost-effectively.

42 ENGINEERING↗

Managing Power Systems-Induced Wildfire Risks Using Optimal Scheduled Shutoffs: Preprint

The growing demands for electricity and the increase in extreme weather conditions are putting unprecedented pressure on our electrical grids. Oftentimes, this pressure leads to electrical components failures which might ignite wildfires. This work develops a novel model to balance the reliability of power networks operations and risks of wildfires ignition by optimizing the operational schedule of power transmission networks considering time-varying risk measures that consider exogenous and operational factors. Energy storage systems are considered to deliver power during peak wildfire hours and enable temporal load shifting. The problem is formulated as a mixed-integer linear program that maximizes a weighted sum of the served power demand and the reduction in grid-induced wildfires risk. The results demonstrate the ability of the model to reduce wildfires risks significantly without considerable load shedding.

energy scheduling↗

System Study: Residual Heat Removal 1998–2018

This report presents an unreliability evaluation of the residual heat removal (RHR) system in two modes of operation (low-pressure injection in response to a large loss-of-coolant accident and post-trip shutdown-cooling) at 104 U.S. commercial nuclear power plants. Demand, run hours, and failure data from calendar years 1998 through 2018 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the RHR results.

99 GENERAL AND MISCELLANEOUS↗

Design and testing of a high power spacecraft thermal management system

The design and test results are presented of an ammonia hybrid capillary pumped loop thermal control system which could be used for heat acquisition and transport on future large space platforms and attached payloads, such as those associated with the NASA Space Station. The High Power Spacecraft Thermal Management System (HPSTM) can operate as either a passive, capillary pumped two phase thermal control system, or, when additional pressure head is required, as a mechanically pumped loop. Testing has shown that in the capillary mode, the HPSTM evaporators can acquire a total heat load of between 600 W and 24 kW, transported over 10 meters, at a maximum heat flux density of 4.3 W/sq cm. With the mechanical pump circulating the ammonia, a heat acquisition potential of 52 kW was demonstrated for 15 minutes without an evaporator failure. These results represent a significant improvement over the maximum transport capability previously displayed in other capillary systems. The HPSTM system still retains the proven capillary capabilities of heat load sharing and flow control between evaporator plates, rapid power cycling, and nonuniform heating in both the capillary and hybrid operating modes.

Mccabe, Michael E., Jr.↗

Coupled-DC Module-Based Photovoltaic System With Power Mismatch-Tolerated Modulation

Here, this article presents a coupled-DC power module-based cascaded multilevel converter integrating utility-scale photovoltaic (PV) generations (coupled-DC-link power module (CDPM)-PV). CDPM-PV inherits merits such as modular structure, distributed maximum power point tracking (MPPT), direct distribution grid access, from cascaded H-bridge-based PV (CHB-PV) system. But, it supplies more flexible power routes than CHB-PV, through coupling different DC-links. Power routes are intended for enlarging the entire operating range including conditions of active power mismatch arising from nonideal elements such as partial shading and parameter variations. The system construction with its self-balancing principle is first introduced. Switching states for different operating regions are then derived based on the principle of easing implementation. Based on these, a modulation strategy including initial switching pattern selection and coordinated power routing is proposed to allow module-mismatches. Operating ranges are also analyzed and compared with conventional CHB-PV. Simulation results of a 3-MW/13.8-kV system developed in MATLAB/Simulink platform, and experiment results based on a 2.4-kW/311-V setup are presented and have demonstrated that the CDPM-PV topology with proposed modulation strategy can not only ride through a larger range of module mismatches, but also improve solar power utilization and system efficiency owing to noncompromised MPPT.

14 SOLAR ENERGY↗

Inverter Intensive Hybrid Power Plant Modeling with Small-Signal Stability Augmentation through Flexible Operation Mode Transition

Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.

grid-forming control↗