Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “planning optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

SU-C-304-01: Investigation of Various Detector Response Functions and Their Geometry Dependence in a Novel Method to Address Ion Chamber Volume Averaging Effect

Purpose: A novel convolution-based approach has been proposed to address ion chamber (IC) volume averaging effect (VAE) for the commissioning of commercial treatment planning systems (TPS). We investigate the use of various convolution kernels and its impact on the accuracy of beam models. Methods: Our approach simulates the VAE by iteratively convolving the calculated beam profiles with a detector response function (DRF) while optimizing the beam model. At convergence, the convolved profiles match the measured profiles, indicating the calculated profiles match the “true” beam profiles. To validate the approach, beam profiles of an Elekta LINAC were repeatedly collected with ICs of various volumes (CC04, CC13 and SNC 125) to obtain clinically acceptable beam models. The TPS-calculated profiles were convolved externally with the DRF of respective IC. The beam model parameters were reoptimized using Nelder-Mead method by forcing the convolved profiles to match the measured profiles. We evaluated three types of DRFs (Gaussian, Lorentzian, and parabolic) and the impact of kernel dependence on field geometry (depth and field size). The profiles calculated with beam models were compared with SNC EDGE diode-measured profiles. Results: The method was successfully implemented with Pinnacle Scripting and Matlab. The reoptimization converged in ∼10 minutes. For all tested ICs and DRFs, penumbra widths of the TPS-calculated profiles and diode-measured profiles were within 1.0 mm. Gaussian function had the best performance with mean penumbra width difference within 0.5 mm. The use of geometry dependent DRFs showed marginal improvement, reducing the penumbra width differences to less than 0.3 mm. Significant increase in IMRT QA passing rates was achieved with the optimized beam model. Conclusion: The proposed approach significantly improved the accuracy of the TPS beam model. Gaussian functions as the convolution kernel performed consistently better than Lorentzian and parabolic functions. Further improvement of using geometry-dependent kernels was marginal.

60 APPLIED LIFE SCIENCES↗

Markov Decision Process based Trajectory Planning for UAVs under Uncertain Wind Conditions

In this paper we propose a Markov Decision Process (MDP) algorithm for path-planning of Unmanned Aviation Vehicles (UAVs) under varying wind conditions. Solutions to path-planning for UAVs are becoming increasingly necessary as autonomous UAVs continue to enter commercial and government spaces. Path-planning is inherently challenging, as UAVs needs to account for dynamically changing flying conditions such as weather, obstacle or no-fly zones, degraded vehicle health and off-nominal battery power consumption. Machine learning methods such as Markov Decision Process (MDPs) have the potential to revolutionize how vehicles navigate in such uncertain environments. Previous papers have demonstrated the use of MDPs to optimize UAV path-planning for energy consumption under time-varying wind distribution. In this study, UAV trajectories from a pre-determined waypoint to target cell, will be computed on a 7X7 grid environment by optimizing parameters for mission assurance and safety limits in addition to the energy consumption, and operation time. The UAV navigates the grid by taking actions to move in either of the eight cardinal and intercardinal directions, under constant thrust profile. The next state of the UAV is calculated by considering its action, transition probability, obstacle cells and the wind speed magnitude and direction. Both constant and stochastic wind will be considered in this paper, the parameters being extracted from real wind measurements in proximity to an experimental UAV flight. One of the studies to be demonstrated in this paper is that as the unmanned airspace gets more complex with multiple vehicles and environmental uncertainties, trade-offs between energy consumption, operation time, risk tolerance, and mission assurance needs to be made. Further, MDPs are capable of fast computation of UAV trajectories under varying wind, hence making them suitable for in-flight path planners.

decision-making↗

A scalable planning framework of energy storage systems under frequency dynamics constraints

As the penetration of renewables increases in power systems, the declining system inertia can cause frequency stability issues. Battery energy storage systems (BESSs) respond fast and therefore can relieve the low inertia difficulty but need to be appropriately sized considering the associated cost. This paper presents a novel stochastic optimization model for economically planning BESS capacity while considering the spatial–temporal correlation of wind generation and generator outages under frequency stability constraints, which include the rate-of-change of frequency (RoCoF), frequency nadir (FN), and quasi-steady-state (QSS) frequency. A set of new FN constraints that can be easily linearized is developed. To account for renewable uncertainties, a realistic uncertainty modeling approach, Random Field, is adopted to generate wind generation scenarios by considering both spatial and temporal evolutions of wind speed profiles. The ESS sizing is formulated as a mixed-integer linear programming problem and solved by using a scalable decomposition-and-coordination approach, Surrogate Absolute Value Lagrangian Relaxation (SAVLR). To further improve the scalability and reduce computational burdens, a rolling-horizon-based update is developed and incorporated into SAVLR for providing a practical solution to the long-term planning of very large-scale power systems. Finally, a modified IEEE 118-bus system and the Polish system are used to validate the effectiveness and scalability of the model and solution methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Is a single isocenter sufficient for volumetric modulated arc therapy radiosurgery when multiple intracranial metastases are spatially dispersed?

Previous work demonstrated improved dosimetry of single isocenter volumetric modulated arc therapy (VMAT) of multiple intracranial targets when they are located ≤ 4 cm from isocenter because of narrower multileaf collimators (MLCs). In follow-up, we sought to determine if decreasing isocenter-target distance (d{sub iso}) by using 2 to 3 isocenters would improve dosimetry for spatially dispersed targets. We also investigated the effect of a maximum dose constraint during VMAT optimization, and the dosimetric effect of the number of VMAT arcs used for a larger number of targets (i.e., 7 to 9). We identified radiosurgery cases that had multiple intracranial targets with d{sub iso} of at least 1 target > 5 cm. A single isocenter VMAT plan was created using a standardized 4-arc technique with 18 Gy per target. Each case was then replanned (1) using 2 to 3 isocenters, (2) including a maximum dose constraint per target, and in the case of 7 to 9 targets, (3) using 3 to 6 arcs. Dose evaluation included brain V{sub 6} {sub Gy} and V{sub 12} {sub Gy}, and conformity index (CI), gradient index (GI), and heterogeneity index (HI) per target. Two isocenters were sufficient to limit d{sub iso} to ≤ 4 cm and ≤ 5 cm for 11/15 and 13/15 cases, respectively; after replanning with 2 to 3 isocenters, d{sub iso} decreased from 5.8 ± 2.8 cm (2.3 14.9) to 2.5 ± 1.4 cm (0 5.2). All dose statistics improved on average, albeit modestly: V{sub 6} {sub Gy} = 6.9 ± 7.1%, V{sub 12} {sub Gy} = 0.9% ± 4.4%, CI = 2.6% ± 4.6%, GI = 0.9% ± 12.7%, and HI = 2.6% ± 5.2%; however, the number of arcs doubled and monitor units increase by nearly 2-fold. A maximum dose constraint had a negative effect on all dose indices, increasing V{sub 12} {sub Gy} by 9.7 ± 6.9%. For ≥ 7 targets, increasing number of arcs to > 3 improved CI, V{sub 12} {sub Gy}, and V{sub 6} {sub Gy}. A single isocenter is likely sufficient for VMAT radiosurgery of multiple intracranial metastases. Optimal treatment plan quality is achieved when no constraint is placed on the maximum target dose; for cases with many targets at least 4 arcs are needed for optimal plan quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric quality, accuracy, and deliverability of modulated radiotherapy treatments for spinal metastases

Cancer often metastasizes to the vertebra, and such metastases can be treated successfully using simple, static posterior or opposed-pair radiation fields. However, in some cases, including when re-irradiation is required, spinal cord avoidance becomes necessary and more complex treatment plans must be used. This study evaluated 16 sample intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment plans designed to treat 6 typical vertebral and paraspinal volumes using a standard prescription, with the aim of investigating the advantages and limitations of these treatment techniques and providing recommendations for their optimal use in vertebral treatments. Treatment plan quality and beam complexity metrics were evaluated using the Treatment And Dose Assessor (TADA) code. A portal-imaging–based quality assurance (QA) system was used to evaluate treatment delivery accuracy, and radiochromic film measurements were used to provide high-resolution verification of treatment plan dose accuracy, especially in the steep dose gradient regions between each vertebral target and spinal cord. All treatment modalities delivered approximately the same doses and the same levels of dose heterogeneity to each planning target volume (PTV), although the minimum PTV doses in the vertebral plans were substantially lower than the prescription, because of the requirement that the plans meet a strict constraint on the dose to the spinal cord and cord planning risk volume (PRV). All plans met required dose constraints on all organs at risk, and all measured PTV-cord dose gradients were steeper than planned. Beam complexity analysis suggested that the IMRT treatment plans were more deliverable (less complex, leading to greater QA success) than the VMAT treatment plans, although the IMRT plans also took more time to deliver. The accuracy and deliverability of VMAT treatment plans were found to be substantially increased by limiting the number of monitor units (MU) per beam at the optimization stage, and thereby limiting beam modulation complexity. The VMAT arcs that were optimized with MU limitation had higher QA pass rates as well as higher modulation complexity scores (less complexity), lower modulation indices (less modulation), lower MU per beam, larger beam segments, and fewer small apertures than the VMAT arcs that were optimized without MU limitation. It is recommended that VMAT treatments for vertebral volumes, where the PTV abuts or surrounds the spinal cord, should be optimized with MU limitation. IMRT treatments may be preferable to the VMAT treatments, for dosimetry and deliverability reasons, but may be inappropriate for some patients because of their increased treatment delivery time.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-F-CAMPUS-T-02: Optimizing Orientations of Hundreds of Intensity-Modulated Beams to Treat Multiple Brain Targets

Purpose: To investigate a new modulated beam orientation optimization (MBOO) approach maximizing treatment planning quality for the state-of-the-art flattening filter free (FFF) beam that has enabled rapid treatments of multiple brain targets. Methods: MBOO selects and optimizes a large number of intensity-modulated beams (400 or more) from all accessible beam angles surrounding a patient’s skull. The optimization algorithm was implemented on a standalone system that interfaced with the 3D Dicom images and structure sets. A standard published data set that consisted of 1 to 12 metastatic brain tumor combinations was selected for MBOO planning. The planning results from various coplanar and non-coplanar configurations via MBOO were then compared with the results obtained from a clinical volume modulated arc therapy (VMAT) delivery system (Truebeam RapidArc, Varian Oncology). Results: When planning a few number of targets (n<4), MBOO produced results equivalent to non-coplanar multi-arc VMAT planning in terms of target volume coverage and normal tissue sparing. For example, the 12-Gy and 4-Gy normal brain volumes for the 3-target plans differed by less than 1 mL ( 3.0 mLvs 3.8 mL; and 35.2 mL vs 36.3 mL, respectively) for MBOO versus VMAT. However, when planning a larger number of targets (n≥4), MBOO significantly reduced the dose to the normal brain as compared to VMAT, though the target volume coverage was equivalent. For example, the 12-Gy and 4-Gy normal brain volumes for the 12-target plans were 10.8 mL vs. 18.0 mL and 217.9 mL vs. 390.0 mL, respectively for the non-coplanar MBOO versus the non-coplanar VMAT treatment plans, yielding a reduction in volume of more than 60% for the case. Conclusion: MBOO is a unique approach for maximizing normal tissue sparing when treating a large number (n≥4) of brain tumors with FFF linear accelerators. Dr Ma and Dr Sahgal are currently on the board of international society of stereotactic radiosurgery. Dr Sahgal has received support for educational presentations from Elekta company.

60 APPLIED LIFE SCIENCES↗

TU-EF-304-11: Therapeutic Benefits of Collimation in Spot Scanning Proton Therapy in the Treatment of Brain Cancer

Purpose: A dynamic collimation system (DCS) based on two orthogonal pairs of mobile trimmer blades has recently been proposed to reduce the lateral penumbra in spot scanning proton therapy (SSPT). The purpose of this work is to quantify the therapeutic benefit of using the DCS for SSPT of brain cancer by comparing un-collimated and collimated treatment plans. Methods: Un-collimated and collimated brain treatment plans were created for five patients, previously treated with SSPT, using an in-house treatment planning system capable of modeling collimated and un-collimated beamlets. Un-collimated plans reproduced the clinically delivered plans in terms of target coverage and organ-at-risk (OAR) sparing, whereas collimated plans were re-optimized to improve the organ-at-risk sparing while maintaining target coverage. Physical and biological comparison metrics such as dose distribution conformity, mean and maximum doses, normal tissue complication probability (NTCP) and risk of secondary brain cancer were used to evaluate the plans. Results: The DCS systematically improved the dose distribution conformity while preserving the target coverage. The average reduction of the mean dose to the 10-mm ring surrounding the target and the healthy brain were 7.1% (95% CI: 4.2%–9.9%; p<0.01) and 14.3% (95% CI: 7.8%–20.8%; p<0.01), respectively. This yielded an average reduction of 12.0% (95% CI: 8.2%–15.7%; p<0.01) for the brain necrosis NTCP using the Flickinger model, and 14.2% (95% CI: 7.7%–20.8%; p<0.01) for the risk of secondary brain cancer. The average maximum dose reductions for the brainstem, chiasm, optic nerves, cochleae and pituitary gland when comparing un-collimated and collimated plans were 14.3%, 10.4%, 11.2%, 13.0%, 12.9% and 3.4%, respectively. Evaluating individual plans using the Lyman-Kutcher-Burman NTCP model also yielded improvements. Conclusion: The lateral penumbra reduction performed by the DCS increases the normal tissue sparing capabilities of SSPT for brain tumor treatment while preserving the target coverage. This research was financially supported by Ion Beam Applications S.A. (IBA, Louvain-La-Neuve, Belgium)

60 APPLIED LIFE SCIENCES↗

Comparison of Oncentra® Brachy IPSA and graphical optimisation techniques: a case study of HDR brachytherapy head and neck and prostate plans

There are a number of different dwell positions and time optimisation options available in the Oncentra® Brachy (Elekta Brachytherapy Solutions, Veenendaal, The Netherlands) brachytherapy treatment planning system. The purpose of this case study was to compare graphical (GRO) and inverse planning by simulated annealing (IPSA) optimisation techniques for interstitial head and neck (HN) and prostate plans considering dosimetry, modelled radiobiology outcome and planning time. Four retrospective brachytherapy patients were chosen for this study, two recurrent HN and two prostatic boosts. Manual GRO and IPSA plans were generated for each patient. Plans were compared using dose–volume histograms (DVH) and dose coverage metrics including; conformity index (CI), homogeneity index (HI) and conformity number (CN). Logit and relative seriality models were used to calculate tumour control probability (TCP) and normal tissue complication probability (NTCP). Approximate planning time was also recorded. There was no significant difference between GRO and IPSA in terms of dose metrics with mean CI of 1.30 and 1.57 (P > 0.05) respectively. IPSA achieved an average HN TCP of 0.32 versus 0.12 for GRO while for prostate there was no significant difference. Mean GRO planning times were greater than 75 min while average IPSA planning times were less than 10 min. Planning times for IPSA were greatly reduced compared to GRO and plans were dosimetrically similar. For this reason, IPSA makes for a useful planning tool in HN and prostate brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring the benefits of utilizing small modular device for sustainable and flexible shale gas water management

Growing shale gas extraction in recent years has triggered wide discussions on the associated freshwater requirement and wastewater management. Many optimization approaches have been developed for shale gas water management; however, most of the studies assumed permanent utilization of wastewater treatment facilities with fixed capacities. Considering the rapidly declining characteristics of shale gas wastewater production, these treatment facilities could remain largely underutilized after the first few months/years of production, making them less economically attractive. To maximize the capacity utilization of treatment facilities and further improve the economic performance of shale gas development, this study develops a systematic optimization framework, where the capacity strategy of conventional treatment facilities and utilization of the recent concept of modular manufacturing are both considered for flexible shale gas water management. The proposed mixed-integer linear programming (MILP) model simultaneously optimizes the design and planning of integrated shale gas and water supply chain, with a focus on capacity planning for both large-scale conventional treatment facilities and small-scale modular devices. A series of Marcellus-based case studies are performed to illustrate the applicability of the proposed model and provide general insights into the trade-offs between the multiple types of treatment facilities. The optimization results reveal that the combinatorial utilization of conventional facilities and modular devices for wastewater treatment (66% by conventional facilities and 34% by modular devices) brings 9.3% more reused water for other well development and 6.2% savings in water-related costs, compared to flexible management of only conventional facilities. Furthermore, this work suggests that taking modular device as auxiliary equipment for shale gas water management is most beneficial to increase the capacity utilization of treatment facilities and achieve a more economic and sustainable shale gas production system.

04 OIL SHALES AND TAR SANDS↗

A linguistic geometry for 3D strategic planning

This paper is a new step in the development and application of the Linguistic Geometry. This formal theory is intended to discover the inner properties of human expert heuristics, which have been successful in a certain class of complex control systems, and apply them to different systems. In this paper we investigate heuristics extracted in the form of hierarchical networks of planning paths of autonomous agents. Employing Linguistic Geometry tools the dynamic hierarchy of networks is represented as a hierarchy of formal attribute languages. The main ideas of this methodology are shown in this paper on the new pilot example of the solution of the extremely complex 3D optimization problem of strategic planning for the space combat of autonomous vehicles. This example demonstrates deep and highly selective search in comparison with conventional search algorithms.

Stilman, Boris↗

Sci—Sat AM: Stereo — 06: Dosimetric Comparison of 3D Conformai, Flattened and Flattening Filter-Free TrueBeam RapidArc Planning for Lung SBRT

The major advantages of the VMAT SBRT plans compared to the conventional 3D conformai plan include faster delivery and improved target dose conformity. This study quantifies the dosimetric differences among 3D conformai plan; flattened beam and flattening filter-free (FFF) beam RapidArc Plans for lung SBRT. Five early stage lung cancer patients with various tumor positions and sizes previously treated with 3D non-coplanar SBRT were randomly selected. 4DCT was used for each patient to determine the internal target volume. Abdominal compression was applied to minimize respiratory motion for SBRT patients. For treatment planning, a 5 mm margin was given to the ITV to generate a planning target volume. The prescription dose was 48 Gy in 4 fractions and normalized to 95% of the PTV. Organs at risk (OAR) included spinal cord, esophagus, heart, trachea, bilateral lung, and great vessels. Optimization constraints were set to meet the criteria of the RTOG-0915 protocol. All VMAT plans were optimized with the RapidArc technique using two full arcs in Eclipse treatment planning system. The RapidArc SBRT plans with flattened 6MV beam and 6MV FFF beam were generated and dosimetric results were compared with the previous treated 3D non-coplanar plans. RapidArc plans demonstrated better conformity to target, sharper dose fall-off in normal tissues and lower dose to normal lung and other OARs than the 3D conformai plans. RapidArc SBRT for FFF beam showed comparable target conformity, adequate tumor dose, and clinically acceptable DVHs of OARs to flattened beams and significantly reduced treatment delivery time.

60 APPLIED LIFE SCIENCES↗

Evaluation of a Knowledge-Based Planning Solution for Head and Neck Cancer

Purpose: Automated and knowledge-based planning techniques aim to reduce variations in plan quality. RapidPlan uses a library consisting of different patient plans to make a model that can predict achievable dose-volume histograms (DVHs) for new patients and uses those models for setting optimization objectives. We benchmarked RapidPlan versus clinical plans for 2 patient groups, using 3 different libraries. Methods and Materials: Volumetric modulated arc therapy plans of 60 recent head and neck cancer patients that included sparing of the salivary glands, swallowing muscles, and oral cavity were evenly divided between 2 models, Model{sub 30A} and Model{sub 30B}, and were combined in a third model, Model{sub 60}. Knowledge-based plans were created for 2 evaluation groups: evaluation group 1 (EG1), consisting of 15 recent patients, and evaluation group 2 (EG2), consisting of 15 older patients in whom only the salivary glands were spared. RapidPlan results were compared with clinical plans (CP) for boost and/or elective planning target volume homogeneity index, using HI{sub B}/HI{sub E} = 100 × (D2% − D98%)/D50%, and mean dose to composite salivary glands, swallowing muscles, and oral cavity (D{sub sal}, D{sub swal}, and D{sub oc}, respectively). Results: For EG1, RapidPlan improved HI{sub B} and HI{sub E} values compared with CP by 1.0% to 1.3% and 1.0% to 0.6%, respectively. Comparable D{sub sal} and D{sub swal} values were seen in Model{sub 30A}, Model{sub 30B}, and Model{sub 60}, decreasing by an average of 0.1, 1.0, and 0.8 Gy and 4.8, 3.7, and 4.4 Gy, respectively. However, differences were noted between individual organs at risk (OARs), with Model{sub 30B} increasing D{sub oc} by 0.1, 3.2, and 2.8 Gy compared with CP, Model{sub 30A}, and Model{sub 60}. Plan quality was less consistent when the patient was flagged as an outlier. For EG2, RapidPlan decreased D{sub sal} by 4.1 to 4.9 Gy on average, whereas HI{sub B} and HI{sub E} decreased by 1.1% to 1.5% and 2.3% to 1.9%, respectively. Conclusions: RapidPlan knowledge-based treatment plans were comparable to CP if the patient's OAR-planning target volume geometry was within the range of those included in the models. EG2 results showed that a model including swallowing-muscle and oral-cavity sparing can be applied to patients with only salivary gland sparing. This may allow model library sharing between institutes. Optimal detection of inadequate plans and population of model libraries requires further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multilane Automated Driving With Optimal Control and Mixed-Integer Programming

Road vehicle lane changes often initiate traffic disturbances and can therefore impact road networks’ energy and time efficiency. Furthermore, unexpected changes in traffic conditions may also render lane changes counterproductive for the lane-changing vehicle. Vehicle-to-vehicle connectivity combined with anticipative control could address these challenges via improved lane change decisions by automated vehicles. In a move toward this objective, receding horizon control cast as a mixed-integer quadratic program is used to plan lane changing and acceleration in a coupled optimization. A long-term pacing module, based on Pontryagin’s minimum principle from optimal control theory, sets terminal and input references for receding horizon control to target a user’s expected travel time. To remove nonlinear vehicle dynamics from the receding horizon controller, lane change commands are passed to a pure pursuit steering module whose response is approximated by a second-order linear model. Here, comparison against a rule-based reactive algorithm in arterial and highway scenarios shows an 8.9%–13.7% reduction in energy consumption and a 5.2%–10.3% reduction in the travel time, along with navigational improvements.

33 ADVANCED PROPULSION SYSTEMS↗

A comparison between onestep and other multiconic trajectory propagation methods

The paper presents an optimized version of the one-step multiconic method of spacecraft trajectory propagation in the presence of two attracting bodies. This method is compared to eleven other methods ranging from simple conic propagation to full integration of the equations of motion by applying the methods to a wide variety of test cases taken from planned space missions. This optimize one-step method is shown to be an order of magnitude better than other single-step methods for interplanetary and most lunar trajectories. Multistep multiconics methods and integration of the state offer another order of magnitude improvement, but at a proportionally higher cost and calculation time.

Kiedron, Krystyna↗

Bladder radiotherapy treatment: A retrospective comparison of 3-dimensional conformal radiotherapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy plans

To examine tumor's and organ's response when different radiotherapy plan techniques are used. Ten patients with confirmed bladder tumors were first treated using 3-dimensional conformal radiotherapy (3DCRT) and subsequently the original plans were re-optimized using the intensity-modulated radiation treatment (IMRT) and volumetric-modulated arc therapy (VMAT)-techniques. Targets coverage in terms of conformity and homogeneity index, TCP, and organs' dose limits, including integral dose analysis were evaluated. In addition, MUs and treatment delivery times were compared. Better minimum target coverage (1.3%) was observed in VMAT plans when compared to 3DCRT and IMRT ones confirmed by a statistically significant conformity index (CI) results. Large differences were observed among techniques in integral dose results of the femoral heads. Even if no statistically significant differences were reported in rectum and tissue, a large amount of energy deposition was observed in 3DCRT plans. In any case, VMAT plans provided better organs and tissue sparing confirmed also by the normal tissue complication probability (NTCP) analysis as well as a better tumor control probability (TCP) result. Our analysis showed better overall results in planning using VMAT techniques. Furthermore, a total time reduction in treatment observed among techniques including gantry and collimator rotation could encourage using the more recent one, reducing target movements and patient discomfort.

61 RADIATION PROTECTION AND DOSIMETRY↗

Simultaneous beam sampling and aperture shape optimization for SPORT

Purpose: Station parameter optimized radiation therapy (SPORT) was recently proposed to fully utilize the technical capability of emerging digital linear accelerators, in which the station parameters of a delivery system, such as aperture shape and weight, couch position/angle, gantry/collimator angle, can be optimized simultaneously. SPORT promises to deliver remarkable radiation dose distributions in an efficient manner, yet there exists no optimization algorithm for its implementation. The purpose of this work is to develop an algorithm to simultaneously optimize the beam sampling and aperture shapes. Methods: The authors build a mathematical model with the fundamental station point parameters as the decision variables. To solve the resulting large-scale optimization problem, the authors devise an effective algorithm by integrating three advanced optimization techniques: column generation, subgradient method, and pattern search. Column generation adds the most beneficial stations sequentially until the plan quality improvement saturates and provides a good starting point for the subsequent optimization. It also adds the new stations during the algorithm if beneficial. For each update resulted from column generation, the subgradient method improves the selected stations locally by reshaping the apertures and updating the beam angles toward a descent subgradient direction. The algorithm continues to improve the selected stations locally and globally by a pattern search algorithm to explore the part of search space not reachable by the subgradient method. By combining these three techniques together, all plausible combinations of station parameters are searched efficiently to yield the optimal solution. Results: A SPORT optimization framework with seamlessly integration of three complementary algorithms, column generation, subgradient method, and pattern search, was established. The proposed technique was applied to two previously treated clinical cases: a head and neck and a prostate case. It significantly improved the target conformality and at the same time critical structure sparing compared with conventional intensity modulated radiation therapy (IMRT). In the head and neck case, for example, the average PTV coverage D99% for two PTVs, cord and brainstem max doses, and right parotid gland mean dose were improved, respectively, by about 7%, 37%, 12%, and 16%. Conclusions: The proposed method automatically determines the number of the stations required to generate a satisfactory plan and optimizes simultaneously the involved station parameters, leading to improved quality of the resultant treatment plans as compared with the conventional IMRT plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient geometry-driven information retrieval for IMRT treatment plan quality control

Purpose: Intensity modulated radiation therapy (IMRT) treatment plan quality depends on the planner's level of experience and the amount of time the planner invests in developing the plan. Planners often unwittingly accept plans when further sparing of the organs at risk (OARs) is possible. The authors propose a method of IMRT treatment plan quality control that helps planners to evaluate the doses of the OARs upon completion of a new plan. Methods: It is achieved by comparing the geometric configurations of the OARs and targets of a new patient with those of prior patients, whose plans are maintained in a database. They introduce the concept of a shape relationship descriptor and, specifically, the overlap volume histogram (OVH) to describe the spatial configuration of an OAR with respect to a target. The OVH provides a way to infer the likely DVHs of the OARs by comparing the relative spatial configurations between patients. A database of prior patients is built to serve as an external reference. At the conclusion of a new plan, planners search through the database and identify related patients by comparing the OAR-target geometric relationships of the new patient with those of prior patients. The treatment plans of these related patients are retrieved from the database and guide planners in determining whether lower doses delivered to the OARs in the new plan are feasible. Results: Preliminary evaluation is promising. In this evaluation, they applied the analysis to the parotid DVHs of 32 prior head-and-neck patients, whose plans are maintained in a database. Each parotid was queried against the other 63 parotids to determine whether a lower dose was possible. The 17 parotids that promised the greatest reduction in D{sub 50} (DVH dose at 50% volume) were flagged. These 17 parotids came from 13 patients. The method also indicated that the doses of the other nine parotids of the 13 patients could not be reduced, so they were included in the replanning process as controls. Replanning with an effort to reduce D{sub 50} was conducted on these 26 parotids. After replanning, the average reductions for D{sub 50} of the 17 flagged parotids and nine unflagged parotids were 6.6 and 1.9 Gy, respectively. These results demonstrate that the quality control method has accurately identified not only the parotids that require dose reductions but also those for which dose reductions are marginal. Originally, 11 of out the 17 flagged parotids did not meet the Radiation Therapy Oncology Group sparing goal of V(30 Gy)<50%. Replanning reduced them to three. Additionally, PTV coverage and OAR sparing of the original plans were compared to those of the replans by using pairwise Wilcoxon p test. The statistical comparisons show that replanning compromised neither PTV coverage nor OAR sparing. Conclusions: This method provides an effective quality control mechanism for evaluating the DVHs of the OARs. Adoption of such a method will advance the quality of current IMRT planning, providing better treatment plan consistency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-502: FFF Beams, Jaw-Tracking and Treatment Techniques: Out of Field Dose Considerations for Pediatric Radiation Therapy Delivery

Purpose: To compare the extended dose profile delivered by 3DCRT and VMAT techniques for flattened and flattening-filter-free(FFF) photon beams (6X, 6XFFF,10XFFF), with and without jaw-tracking (JT) on Varian TrueBeam linac. The goal is to determine which treatment technique/modality will minimize the peripheral photon dose exposure (and ultimately minimize the risk of second malignant neoplasms (SMN)) in pediatric patients. Methods: 3DCRT, VMAT, and jaw tracking VMAT (JTVMAT) plans with 6X, 6XFFF and 10XFFF x-ray beams were created on a 30×60×22.5cm solid water phantom with a 551 cc PTV. The 3DCRT plans consisted of a 4FLD arrangement. The optimization objectives for the single-arc VMAT plans was V95%Rx=98% to PTV and minimize dose to a 5cm diameter organ at risk (OAR). The OAR to PTV distance varied from 0–30cm along the long axis at 7.5cm depth. The dose to the center of the OAR was measured using a 0.6cc ion chamber. Results: Relative to the 6X flattened beam, the 10XFFF photon beam had the lowest dose in the penumbra and peripheral region (>15 cm) region by up to 20% and 40%, respectively for all modalities (3DCRT, VMAT, JTVMAT). The 6XFFF beams only showed a dose reduction in the peripheral region (by up to 20%). JT did not significantly affect the peripheral dose for all modalities and energies. Conclusion: Treating pediatric patients with a 10XFFF beam is the most effective way to reduce photon scatter dose in both the penumbra and peripheral regions. However, the neutron dose contribution resulting from the 10MV beam still needs to be considered. For all modalities, 6XFFF was the next effective method to reduce peripheral photon doses. 3DCRT beams had the lowest peripheral doses for all energies compared to VMAT and JTVMAT, however previous publications have shown that this comes at the expense of PTV conformity and OAR sparing.

60 APPLIED LIFE SCIENCES↗