Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “patch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,237 records · Page 69

TU-FG-BRB-09: Thermoacoustic Range Verification with Perfect Co-Registered Overlay of Bragg Peak onto Ultrasound Image

Purpose: The potential of particle therapy has not yet been fully realized due to inaccuracies in range verification. The purpose of this work was to correlate the Bragg peak location with target structure, by overlaying thermoacoustic localization of the Bragg peak onto an ultrasound image. Methods: Pulsed delivery of 50 MeV protons was accomplished by a fast chopper installed between the ion source and the inflector of the 88″ cyclotron at Lawrence Berkeley National Lab. 2 Gy were delivered in 2 µs by a beam with peak current of 2 µA. Thermoacoustic emissions were detected by a cardiac array and Verasonics V1 ultrasound system, which also generated a grayscale ultrasound image. 1024 thermoacoustic pulses were averaged before filtering and one-way beamforming focused signal onto the Bragg peak location with perfect co-registration to the ultrasound images. Data was collected in a room temperature water bath and gelatin phantom with a cavity designed to mimic the intestine, in which gas pockets can displace the Bragg peak. Experiments were performed with the cavity both empty and filled with olive oil. Results: In the waterbath overlays of the Bragg peak agreed with Monte Carlo simulations to within 800±170 µm. Agreement within 1.3 ± 0.2 mm was achieved in the gelatin phantom, although relative stopping powers were estimated only to first order from CT scans. Protoacoustic signals were detected after travel from the Bragg peak through 29 mm and 65 mm of phantom material when the cavity was empty and full of olive oil, respectively. Conclusion: Protoacoustic range verification is feasible with a commercial clinical ultrasound array, but at doses exceeding the clinical realm. Further optimization of both transducer array and injection line chopper is required to enable range verification within a 2 Gy dose limit, which would enable online adaptive treatment. This work was supported in part by a UWM Intramural Instrumentation Grant and by the Director, Office of Science, Office of Nuclear Physics, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. YMQ was supported by a UWM-OUR summer fellowship.

60 APPLIED LIFE SCIENCES↗

TH-AB-209-09: Quantitative Imaging of Electrical Conductivity by VHF-Induced Thermoacoustics

Purpose: To demonstrate that very high frequency (VHF) induced thermoacoustics has the potential to provide quantitative images of electrical conductivity in Siemens/meter, much as shear wave elastography provides tissue stiffness in kPa. Quantitatively imaging a large organ requires exciting thermoacoustic pulses throughout the volume and broadband detection of those pulses because tomographic image reconstruction preserves frequency content. Applying the half-wavelength limit to a 200-micron inclusion inside a 7.5 cm diameter organ requires measurement sensitivity to frequencies ranging from 4 MHz down to 10 kHz, respectively. VHF irradiation provides superior depth penetration over near infrared used in photoacoustics. Additionally, VHF signal production is proportional to electrical conductivity, and prostate cancer is known to suppress electrical conductivity of prostatic fluid. Methods: A dual-transducer system utilizing a P4-1 array connected to a Verasonics V1 system augmented by a lower frequency focused single element transducer was developed. Simultaneous acquisition of VHF-induced thermoacoustic pulses by both transducers enabled comparison of transducer performance. Data from the clinical array generated a stack of 96-images with separation of 0.3 mm, whereas the single element transducer imaged only in a single plane. In-plane resolution and quantitative accuracy were measured at isocenter. Results: The array provided volumetric imaging capability with superior resolution whereas the single element transducer provided superior quantitative accuracy. Combining axial images from both transducers preserved resolution of the P4-1 array and improved image contrast. Neither transducer was sensitive to frequencies below 50 kHz, resulting in a DC offset and low-frequency shading over fields of view exceeding 15 mm. Fresh human prostates were imaged ex vivo and volumetric reconstructions reveal structures rarely seen in diagnostic images. Conclusion: Quantitative whole-organ thermoacoustic tomography will be feasible by sparsely interspersing transducer elements sensitive to the low end of the ultrasonic range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geothermal Case Studies

The US Geological Survey (USGS) resource assessment (Williams et al., 2009) outlined a mean 30GWe of undiscovered hydrothermal resource in the western US. One goal of the Geothermal Technologies Office (GTO) is to accelerate the development of this undiscovered resource. The Geothermal Technologies Program (GTP) Blue Ribbon Panel (GTO, 2011) recommended that DOE focus efforts on helping industry identify hidden geothermal resources to increase geothermal capacity in the near term. Increased exploration activity will produce more prospects, more discoveries, and more readily developable resources. Detailed exploration case studies akin to those found in oil and gas (e.g. Beaumont, et al, 1990) will give operators a single point of information to gather clean, unbiased information on which to build geothermal drilling prospects. To support this effort, the National Renewable Energy laboratory (NREL) has been working with the Department of Energy (DOE) to develop a template for geothermal case studies on the Geothermal Gateway on OpenEI. In fiscal year 2013, the template was developed and tested with two case studies: Raft River Geothermal Area (http://en.openei.org/wiki/Raft_River_Geothermal_Area) and Coso Geothermal Area (http://en.openei.org/wiki/Coso_Geothermal_Area). In fiscal year 2014, ten additional case studies were completed, and additional features were added to the template to allow for more data and the direct citations of data. The template allows for: Data - a variety of data can be collected for each area, including power production information, well field information, geologic information, reservoir information, and geochemistry information. Narratives ? general (e.g. area overview, history and infrastructure), technical (e.g. exploration history, well field description, R&D activities) and geologic narratives (e.g. area geology, hydrothermal system, heat source, geochemistry.) Exploration Activity Catalog - catalog of exploration activities conducted in the area (with dates and references.) NEPA Analysis ? a query of NEPA analyses conducted in the area (that have been catalogued in the OpenEI NEPA database.) In fiscal year 2015, NREL is working with universities to populate additional case studies on OpenEI. The goal is to provide a large enough dataset to start conducting analyses of exploration programs to identify correlations between successful exploration plans for areas with similar geologic occurrence models.

15 GEOTHERMAL ENERGY↗

Design and Manufacture of Tunable Permanent Magnet Based Quadrupole for Next Generation Electron-Ion Colliders [Slides]

The goal of this project is to design and construct of a prototype of quadrupole permanent magnet for the magnet transport lattice for an electron-ion collider. The technical objectives are not only to achieve the field gradient of 34.42T/m in the region of interest, at a radius 16.0mm, relative to the quadrupole axis (z-axis), but also lower the unwanted field harmonics below one unit out of 10,000, especially for Sextupole, Octupole, and Decapole components. The innovation is 1) modular design for cost saving, and 2) adjusting mechanism of each modular magnet for field tuning. The 300-mm long, quadrupole magnet assembly consists of 12 modules of 100-mm long magnet. The magnetic field tuning was implemented by two ways: first, adjusting mechanically the pole tip position for a majority of field tuning, and second, applying the passive shims for a fine field tuning. The magnetic design and optimization of the quadrupole magnet was performed using finite element analysis. The permanent magnet choice was EEC-N44SH grade with the minimum coercivity of 987kA/m (12.4kOe), which has enhanced resistance to demagnetization due to the radiation. The 3D computer-aided design of quadrupole magnet assembly was created based on the magnetic design results. The overall dimensions are 514x500x300mm and its weight is ~470kg (1,050lbs). The weight and volume were minimized through the optimization. Electron Energy Corporation’s vertically integrated manufacturing capability and over 48-years magnet production experience enabled us to implement a “fast prototyping” process and build two quadrupole magnets. Using wire EDM machines, the pole tip profile was precisely fabricated within ±25µm tolerance. The field gradient 34.22T/m was measured using the real time data acquisition system and a 3D Hall probe mounted on the precision XYZ station with the resolution of 1µm (0.00004”). The magnetic field harmonics were measured using a harmonic coil at the Brookhaven National Laboratory, Upton, NY. Faro® laser tracker was used to track the position of each quadrupole while adjusting the pole location mechanically. The normal harmonics were measured up to 20-poles. Overall the 2 nd magnet test data is better than the 1st magnet because of a better symmetry. The adjusting pole technique was proved effective to lower the Sextupole harmonics from -3.14 to -0.71 unit. The Octupole harmonics was improved from -5.67 to -3.45 unit, still not satisfactory. It is found that the proposed approach is not practical and efficient in terms of the mass production although the modular concept can save the manufacturing cost. Another finding is in reality it is hard to adjust mechanically due to the limit of laser tracker resolution .001” and tweak magnetically the field due to the limited harmonics data. Importantly the Brookhaven National Laboratory’s harmonics data doesn’t indicate where the strong/weak field position, which requires another field map test at each measurement. To resolve these, two alternative solutions are introduced; 1) electromagnet correcting coils and 2) 8-pieces quadrupole magnet.

43 PARTICLE ACCELERATORS↗

Stellarator Simplification using Permanent Magnets (PM4Stell)

This Report describes the design and prototyping of an array of rare-Earth permanent magnets to form a stellarator. This effort was motivated by the hypothesis that the usage of permanent magnets, rather than electromagnetic coils with complex geometry, could reduce the cost of stellarator construction and thereby make increase the feasibility of the stellarator as a technology for a fusion-based power plant. In this project, we have developed novel methods for specifying the positions, shapes, and polarizations of the magnets in the array, and have developed designs for mounting structures and tooling for assembly. We have also performed detailed finite-element modeling to qualify the accuracy of the magnetic field produced by the magnet array as designed, and to confirm that the structure can withstand the forces between the magnets. We have also developed techniques for measuring the magnetic field produced by the array once constructed, as well as for correcting errors in the field arising from misalignments and offsets within the tolerances for mounting and fabrication. Finally, we have constructed a tabletop prototype of a section of the array to qualify the concept for assembling and mounting magnets within the array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stellarator Simplification using Permanent Magnets (PM4Stell)

This Report describes the design and prototyping of an array of rare-Earth permanent magnets to form a stellarator. This effort was motivated by the hypothesis that the usage of permanent magnets, rather than electromagnetic coils with complex geometry, could reduce the cost of stellarator construction and thereby make increase the feasibility of the stellarator as a technology for a fusion-based power plant. In this project, we have developed novel methods for specifying the positions, shapes, and polarizations of the magnets in the array, and have developed designs for mounting structures and tooling for assembly. We have also performed detailed finite-element modeling to qualify the accuracy of the magnetic field produced by the magnet array as designed, and to confirm that the structure can withstand the forces between the magnets. We have also developed techniques for measuring the magnetic field produced by the array once constructed, as well as for correcting errors in the field arising from misalignments and offsets within the tolerances for mounting and fabrication. Finally, we have constructed a tabletop prototype of a section of the array to qualify the concept for assembling and mounting magnets within the array.

47 OTHER INSTRUMENTATION↗

Enabling The Next Generation of Smart Sensors in Coal Fired Power Plants using Cellular 5G Technology

Ohio University (OHIO), West Virginia University (WVU), and American Electric Power (AEP) proposed to study and report on the benefits of 5G wireless cellular technologies for coal-fired power plants. The significant advantages, cost savings, and potential of 5G wireless data communications based sensors promised to usher in a new era of reliable, inexpensive, and powerful embedded systems that had not previously been available for coal-fired power plants. The team built upon existing experience with cellular-based systems, power plant water quality sensing, and high temperature sensors developed during past projects. Principal Investigator Wilhelm had been developing cellular-based sensor data systems with a commercial partner for 10 years, pioneering innovative solar-powered devices that began with 2G technology. The lessons and knowledge gained served as a foundation to demonstrate innovations and potential impacts specific to coal fired power plants enabled by 5G technology, along with integration with existing sensors and systems.

20 FOSSIL-FUELED POWER PLANTS↗

Draft genome sequences of Chrysoporthe austroafricana, Diplodia scrobiculata, Fusarium nygamai, Leptographium lundbergii, Limonomyces culmigenus, Stagonosporopsis tanaceti, and Thielaviopsis punctulata

The genomes of Chrysoporthe austroafricana, Diplodia scrobiculata, Fusarium nygami, Leptographium lundbergii, Limonomyces culmigenus, Stagonosporopsis tanaceti , and Thielaviopsis punctulata are presented in this genome announcement. These seven genomes are from endophytes, plant pathogens and economically important fungal species. The genome sizes range from 26.6 Mb in the case of Leptographium lundbergii to 44 Mb for Chrysoporthe austroafricana . The availability of these genome data will provide opportunities to resolve longstanding questions regarding the taxonomy of species in these genera, and may contribute to our understanding of the lifestyles through comparative studies with closely related organisms.

Mycology↗