SIREN: Scaling Ion-Traps by REquiring iNnovative Heterogenous Integration

The SIREN (Scaling Ion Traps by Requiring iNnovative heterogenous integration) project explores the feasibility of heterogeneous integration (HI) as a transformative approach to scaling ion traps, a critical technology for advancing quantum computers and atomic clocks. Traditional ion trap architectures face significant challenges in scalability due to limitations in optical access, fabrication techniques, and material constraints. SIREN addresses these challenges by leveraging HI, which combines different materials and fabrication processes to create more complex and efficient ion trap structures. HI integrated structures can be manufactured without compromising the process to maintain compatibility to ion traps. This project focuses on integrating a separately fabricated waveguide with a fully functional ion trap. The respective alignment between the pieces needs to be accurate to less than 2 µm to ensure that the light from the waveguide can overlap with the trapping region. The fine alignment must also be maintained through an ultra-high vacuum bake, a critical step in preparing an ion trap experiment. The project's outcomes suggest that heterogeneous integration is a promising pathway for overcoming current scalability barriers, paving the way for the next generation of quantum technologies. SIREN's findings contribute significantly to the field, offering a scalable solution that could accelerate the development of practical quantum computers and highly accurate atomic clocks.

42 ENGINEERING↗

Synthesis of nanodiamonds encapsulated by zeolitic imidazole framework-8 for quantum sensing applications

Nitrogen vacancy (NV)-containing nanodiamonds are widely used in quantum sensing applications due to their high sensitivity to magnetic fields, relatively low cost, and ability to be initialized, manipulated, and read out at room temperature. Quantum sensing techniques such as optically detected magnetic resonance (ODMR) and spin relaxometry have exploited the sensitivity of the NV nanodiamonds to magnetic fields to detect a range of analytes, such as pH, metal ions, and biomolecules. However, diversifying the sensing targets accessible by NV diamond quantum sensors typically requires careful engineering of the diamond surface chemistry with stimuli-responsive functional groups. Here, a simple protocol for coating NV nanodiamonds with the zeolitic imidazole framework 8 (ZIF-8), a widely used metal-organic framework, is presented. ZIF-8 is a highly porous material that has been used as a selective sensor for gasses, metal ions, and other analytes. The material is well-characterized by x-ray diffraction, transmission electron microscopy, scanning electron microscopy, x-ray photoelectron spectroscopy, and luminescence spectroscopy. Encapsulation of NV nanodiamonds with a porous scaffold such as ZIF-8 provides a promising method for improving the selectivity for the quantum sensing of various analytes. Importantly, the ZIF-8 coating does not impact the luminescence properties of the NV diamond, which is a key readout in ODMR and spin relaxometry sensing approaches. Indeed, the ODMR spectra with and without the ZIF-8 shell is nearly identical. Moreover, the ZIF-8 coating increases the longitudinal spin relaxation time of the NV nanodiamond by a factor of 4 relative to aggregated diamond, a desirable outcome for spin relaxation-based quantum sensing. Metal-organic framework composites with nanodiamonds thus are an exciting strategy for enhancing NV nanodiamond performance in applications such as quantum sensing and quantum-enhanced nuclear magnetic resonance spectroscopy.

nitrogen vacancy nanodiamond↗

Ion Traps and Packaging for Heterogenous Integration - Chimera

Microfabricated surface ion traps and silicon-based photonics are critical technologies for scaling quantum systems. Current ion trap architectures face scalability and integration challenges due to limitations in optical access, fabrication techniques, and material compatibility. State-of-the-art quantum computers and atomic clocks are investigating monolithic integration, which necessitates custom traps for each ion species and has not overcome the integration hurdles presented by merging these technologies. The Chimera (Ion Traps and Packaging for Heterogeneous Integration) project proposes a novel approach utilizing heterogeneous integration (HI) of ion traps and photonic circuits. This separation of components allows for flexibility in ion trap design and reduces fabrication compromises. The Chimera project specifically designed an ion trap to interface vertically with a separately fabricated waveguide chip and demonstrates the first steps to integrating them at the packaging level. The ion trap features a large area of removed silicon, allowing the photonics chip outputs closer to the ion trap, improving alignment and packaging processes. The alignment must be accurate to < 1 µm to ensure that the light from the waveguide can overlap with the trapping region. This fine alignment must also be maintained through an ultra-high vacuum bake, a critical step in preparing an ion trap experiment. By combining separate chips, we demonstrate a new path for scaling trapped ion technology that is less reliant on monolithic integration. We successfully fabricated a trap with a large area of oxide removed, resulting in a region thinned to about 40 µm, a key milestone toward successful integration.

42 ENGINEERING↗

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Neutrons have historically been used for a broad range of biological applications employing techniques such as small-angle neutron scattering, neutron spin echo, diffraction, and inelastic scattering. Unlike neutron scattering techniques that obtain information in reciprocal space, attenuation-based neutron imaging measures a signal in real space that is resolved on the order of tens of micrometers. The principle of neutron imaging follows the Beer-Lambert law and is based on the measurement of the bulk neutron attenuation through a sample. Greater attenuation is exhibited by some light elements (most notably, hydrogen), which are major components of biological samples. Contrast agents such as deuterium, gadolinium, or lithium compounds can be used to enhance contrast in a similar fashion as it is done in medical imaging, including techniques such as optical imaging, magnetic resonance imaging, X-ray, and positron emission tomography. For biological systems, neutron radiography and computed tomography have increasingly been used to investigate the complexity of the underground plant root network, its interaction with soils, and the dynamics of water flux in situ. Moreover, efforts to understand contrast details in animal samples, such as soft tissues and bones, have been explored. This manuscript focuses on the advances in neutron bioimaging such as sample preparation, instrumentation, data acquisition strategy, and data analysis using the High Flux Isotope Reactor CG-1D neutron imaging beamline. The aforementioned capabilities will be illustrated using a selection of examples in plant physiology (herbaceous plant/root/soil system) and biomedical applications (rat femur and mouse lung).

Bilheux, Hassina↗

A survey of laser display

Laser display systems, discussing mechanical, diffractive and refractive beam deflection techniques, electro-optical polarization devices, holographic displays, etc

Devaney, A. J.↗

Photosensor aperture shaping to reduce aliasing in optical-mechanical line-scan imaging systems.

Review of optical-mechanical scanning techniques that are generally employed in instruments specifically designed to characterize variations in scene brightness spectrally or radiometrically. Special attention is given to the effect of aliasing on the spatial detail of the reconstructed image. Aliasing may be caused by linescan sampling and can, in turn, severely degrade images that emphasize the spatial characterization of a scene. Photosensor aperture shaping and line-scan spacing are investigated as means for reducing this degradation.

Katzberg, S. J.↗

Signal conditioning electronics for a laser vector velocimeter.

A type of laser velocimeter termed a laser vector velocimeter (LVV) resolves the 180 deg directional ambiguity problem of the conventional laser velocimeter by exploiting optical frequency translation techniques and frequency division demultiplexing techniques. This paper defines some fundamental LVV system signal characteristics and signal conditioning and data acquisition problems. The signal conditioning electronics for a three velocity component LVV system are described. Data obtained from atmospheric wind velocity measurements using a two velocity component LVV system are presented to illustrate the vector velocity measurement capabilities of the system. The operational status LVV systems presently in use are two orthogonal velocity component units. However, a laboratory status LVV system has been used to make three-dimensional vector velocity measurements.

Crosswy, F. L.↗

Optical data processing and projected applications of the ERTS-1 imagery covering the 1973 Mississippi River Valley floods

Flooding along the Mississippi River and some of its tributaries was imaged by the multispectral scanner (MSS) on the Earth Resources Technology Satellite (ERTS-1) on at least three orbits during the spring of 1973. The ERTS data provided the first opportunity for mapping the regional extent of flooding at the time the imagery was acquired. Special optical data processing techniques were used to produce a variety of multispectral color composites which enhanced floodplain details. One of these, a two-color composite of near infrared bands 6 and 7, was enlarged and registered to 1:250,0OO-scale topographic maps and used as the basis for preparation of flood image maps. Two specially filtered three-color composites of MSS bands 5, 6, and 7 and 4, 5, and 7 were prepared to aid in the interpretation of the data. The extent of the flooding was vividly depicted on a single image by two-color temporal composites produced on the additive-color viewer using band 7 flood data superimposed on pre-flood band 7 images. On May 24, when the floodwaters at St. Louis receded to bankfull stage, imagery was again obtained by ERTS. Analysis of temporal data composites of the pre-flood and post-flood band 7 images indicate that changes in surface reflectance characteristics caused by the flooding can be delineated, thus making it possible to map the overall area flooded without the necessity of a real-time system to track and image the peak flood waves. Regional planning and disaster relief agencies such as the Corps of Engineers, Office of Emergency Preparedness, Soil Conservation Service, interstate river basin commissions and state agencies, as well as private lending and insurance institutions, have indicated strong potential applications for ERTS image-maps of flood-prone areas.

Morris Deutsch↗

Pressure-viscosity measurements for several lubricants to 5.5 x 10 to the 8th power Newtons per square meter (8 x 10 to the 4th psi) and 149 C (300 F)

A capillary viscometer was used to measure viscosity as a function of pressure, temperature, and shear stress for a number of lubricants. The conditions under which the measurements were made are specified. The results obtained for each material are analyzed. It was determined that all pressure-viscosity coefficients decreased with increasing temperature. Data from other techniques such as optical elastohydrodynamics, oscillating crystal, and low shear capillary viscometry were compared with the results obtained.

Jones, W. R.↗

Terminal navigation analysis for the 1980 comet Encke slow flyby mission

The initial results of a terminal navigation analysis for the proposed 1980 solar electric slow flyby mission to the comet Encke are presented. The navigation technique employs onboard optical measurements with the scientific television camera, groundbased observations of the spacecraft and comet, and groundbased orbit determination and thrust vector update computation. The knowledge and delivery accuracies of the spacecraft are evaluated as a function of the important parameters affecting the terminal navigation. These include optical measurement accuracy, thruster noise level, duration of the planned terminal coast period, comet ephemeris uncertainty, guidance initiation time, guidance update frequency, and optical data rate.

Jacobson, R. A.↗

Electronic-to-vibrational energy transfer efficiency in the O/1 D/-N2 and O/1 D/-CO systems

With the aid of a molecular resonance fluorescence technique, which utilizes optical pumping from the v = 1 level of the ground state of CO by A 1 Pi-X 1 Sigma radiation, a study is made of the efficiency of E-V transfer from O(1 D) to CO. O(1 D) is generated at a known rate by O2 photodissociation at 1470 A in an intermittent mode, and the small modulation of the fluorescent signal associated with CO (v = 1) above the normal thermal background is interpreted in terms of E-V transfer efficiency. The CO (v = 1) lifetime in this system is determined mainly by resonance trapping of the IR fundamental band, and is found to be up to ten times longer than the natural radiative lifetime. For CO, (40 plus or minus 8)% of the O(1 D) energy is converted into vibrational energy. By observing the effect of N2 on the CO (v = 1) fluorescent intensity and lifetime, it is possible to obtain the E-V transfer efficiency for the system O(1 D)-N2 relative to that for O(1 D)-CO. The results indicate that the efficiency for N2 is (83 plus or minus 10)% of that for CO.

Slanger, T. G.↗

High purity silica reflective heat shield development

A high purity slip cast silica material has been developed for use as a reflective heat shield for entries into the atmospheres of the outer planets. The several stages leading to the development of this material are described and details of raw material selection, preparation of the slip material and casting techniques are discussed. Optical (reflectance and transmittance), physical and chemical properties measurements were performed as a function of the important material and processing variables. Performance analysis of a reflective heat shield fabricated from the high purity silica slip shows that approximately 90 percent of the radiant bow shock energy incident on the heat shield during entry into the atmosphere of Jupiter will be reflected.

Blome, J. C.↗

Laser holographic detection of tiny thin tapes beneath a thick opaque composite structure

Real-time laser holographic interferometry technique has been applied successfully in the detection of 1mm x 1mm x 0.025mm duct tapes hidden beneath a 150mm x 150mm x 16mm ceramic-epoxy-fiberglass sandwiched structure. The experimental results clearly demonstrate future applicability of this technique in the optical nondestructive detection of debonds and flaws in such composite structures.

Liu, H.-K.↗

Proximity sensor technology for manipulator end effectors

Optical proximity sensing techniques which could be used to help control the critical grasping phase of a remote manipulation are described. The proximity sensors described use a triangulation geometry to detect a surface located in a pre-determined region. The design of the proximity sensors themselves is discussed, as well as their application to manipulator control with a local control loop, and possibilities for future development are discussed.

Johnston, A. R.↗