Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modal test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Simulation of the photogrammetric appendage structural dynamics experiment

The Photogrammetric Appendage Structural Dynamics Experiment (PASDE) uses six video cameras in the Space Shuttle cargo bay to measure vibration of the Russian Mir space station Kvant-ll solar array. It occurs on Shuttle/Mir docking mission STS-74 scheduled for launch in November 1995. The objective of PASDE is to demonstrate photogrammetric technology for measuring 'untargeted' spacecraft appendage structural dynamics. This paper discusses a pre-flight simulation test conducted in July 1995, focusing on the image processing aspects. The flight camera system recorded vibrations of a full-scale structural test article having grids of white lines on black background, similar in appearance to the Mir solar array. Using image correlation analysis, line intersections on the structure are tracked in the video recordings to resolutions of less than 0.1 pixel. Calibration and merging of multiple camera views generated 3-dimensional displacements from which structural modal parameters are then obtained.

Pappa, Richard S.↗

Vibroacoustic testing of Space Shuttle thermal protection system panels

The modes and acoustic responses of two panels representing Space Shuttle thermal protection panels were investigated. The panels consisted of flat aluminum sheet stiffened longitudinally with hat-section stringers and corrugated supporting panels representing Shuttle ring frame bulkheads. In addition, one panel had 24 tiles of LI900 silica thermal insulation material and a strain isolator pad bonded to the face sheet. Both panels were found to have approximately eight modal frequencies in the 60 to 500 Hz range, where Shuttle acoustic loads are expected to be high. The strain response to a progressive acoustic wave representing a Shuttle spectrum was characterized by the occurrence of larger strains in the direction normal to the stringers than in the direction parallel to the stringers; three modes in the 100 to 400 Hz range contributed significantly to the strain response.

Rucker, C. E.↗

Predicted vibration responses of Apollo structure and effects of pressure correlation lengths on response

Progressive wove and reverberant acoustic fields ore often used in the laboratory for qualification testing of aerospace structures that are subjected to unsteady aerodynamic environments which occur during flight through the atmosphere. Acoustic simulation of these in-flight environments i s achieved i f the structural vibration response to acoustic excitation is equivalent, over the frequency range of interest, to the response caused by aerodynamic turbulence. To determine the degree of response simulation that could be expected for such qualification testing of the Apollo Spacecraft, responses of a segment of the Apollo structure were estimated theoretically for both acoustic and flight environments. The vibration analysis presented in this report was performed for the Spacecraft Lunar Module Adaptor; and the three environments treated are turbulence at Mach 1 and Mach 2, a reverberant acoustic field, and a modified acoustic progressive wave field. The progressive wave field is assumed to be generated within a specially designed shroud of sixteen axially oriented ducts which is constructed around and contoured to the external skin of the vehicle. Each duct is open on the side adjacent to the skin and is driven acoustically at one end by an independent noise source, thus allowing for different pressure correlation patterns around the circumference of the vehicle. The purpose of the analysis was to determine the effects of surface pressure correlation lengths on the response characteristics of representative Apollo structure, and to select on this basis, the optimum acoustic environment for structural vibration qualification tests of the Apollo in the Spacecraft Acoustic Laboratory at MSC. The method of analysis employed consists of determining, independently, the space average, mean-square acceleration spectral density for each of the significant modes of vibration of an equivalent cylindrical shell, and then expressing the total structural response as a linear summation of these modal responses. Approximately 570 classical modes of a pinned-end cylinder were used in order to find the spectral response characteristics of the structure throughout the frequency range of 10 - 1,000 Hz. The effective forcing functions or joint acceptances of the various modes of vibration were computed and are presented graphically for each of the pressure excitation environments. A brief development of the response equations used is presented in the report. Space average acceleration response spectra were computed for twelve different cases including aerodynamic turbulence at Mach 1 and Mach 2, reverberant acoustic field, five duct correlation patterns, two cases of an axially damped progressive wave field, and two cases in which the structural damping constant was varied from the expected value. The response spectra were computed and plotted by a high speed digital computer far a flat excitation pressure spectrum; and the response spectra were numerically integrated to give one-third octave bond average responses. A complete set of digital computer programs has been developed for both flat plate and cylindrical shell structures for the above environments, and each requires run times of three minutes or less. Thus, the work presented herein, along with the results, constitutes a practical advancement to the existing state-of-the-art of vibration prediction.

R W White↗

Investigation of interior noise in a twin-engine light aircraft

This paper describes experimental studies of interior noise in a twin-engine, propeller-driven, light aircraft. An analytical model for this type of aircraft is also discussed. Results indicate that interior noise levels in this aircraft due to propeller noise can be reduced by reducing engine rpm at constant airspeed (about 3 dB), and by synchrophasing the twin engines/propellers (perhaps up to 12 dB). Ground tests show that the exterior noise pressure imposed on the fuselage consists of a complex combination of narrow-band harmonics due to propeller and engine exhaust sources. This noise is reduced by about 20-40 dB (depending on the frequency) by transmission through the sidewall to the cabin interior. The analytical model described uses modal methods and incorporates the flat-side geometrical and skin-stringer structural features of this light aircraft.

Mixson, J. S.↗

Development of an on-line parameter estimation system using the discrete modal filter

Ongoing development of an automated system for monitoring the frequency and damping of time varying structural systems is discussed. A spatial filtering technique called the discrete modal filter is used to uncouple multiple response measurements into modal coordinate responses. Since the modal coordinate responses are the responses of single-degree-of-freedom systems, the frequency and damping may be accurately estimated with short data records. An on-line monitoring system is discussed which may be useful in a variety of applications. The focus in this paper is on the application to aircraft flight flutter testing.

Shelley, S. J.↗

Denoising diffusion probabilistic models for generative alloy design

Inverse material design is an extremely challenging optimization task made difficult by, in part, the highly nonlinear relationship linking performance with composition. Quantitative approaches have improved significantly owing to advances in high throughput experimentation and computational thermodynamics. However, existing physics-based tools are mostly forward models; input a chemistry and obtain a prediction. More recently the materials community has leveraged advances in the machine learning community to establish novel inverse design frameworks. Very recently denoising diffusion probabilistic models have been shown to be extremely powerful generators producing synthetic data of various modalities e.g. images, text, audio, tables, etc.. In this work a novel framework for alloy design and optimization is proposed leveraging these class of models. Five key generative tasks are demonstrated (1) unconditional generation (2) composition conditioned generation (3) property conditioned generation (4) multi-feedstock conditioned generation and (5) generative optimization. These methods were tested on three case studies: high entropy alloy design, superalloy binder jet additive manufacturing, and in-situ dual-feedstock wire-arc additive manufacturing. Results indicate that the established models are extremely flexible, expressive, and robust. The architecture’s flexibility and training procedure empower the model to learn complex intra-compositional and composition-property relationships. Furthermore, the probabilistic nature of these models makes them well suited for addressing solution non-uniqueness and tackling uncertainty quantification tasks. While the fidelity and quantity of the underlying training data is paramount, we envision that future alloy design frameworks will make extensive use of these kinds of machine learning models as “search” tools bolstering the utility of experimental and computational approaches.

36 MATERIALS SCIENCE↗

Active damping of modal vibrations by force apportioning

The theory and numerical simulation of active structural damping is described which requires few discrete control thrusters positioned on the structure. A particular apportioning of coherently phased control forces is applied for each vibration mode which is to be damped; this strongly affects the damped vibration mode, while minimally exciting all other modes. The force apportioning used is that which would tune a target mode if the structure was being shaken in a model vibration test. In contrast to model testing, the forces are varied temporally so as to dampen, rather than excite, the target mode(s).

Hallauer, W. L., Jr.↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S. Faragalla↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S Faragalla↗

TH-CD-BRA-02: 3D Remote Dosimetry for MRI-Guided Radiation Therapy: A Hybrid Approach

Purpose: To validate the dosimetric accuracy of a commercially available MR-IGRT system using a combination of 3D dosimetry measurements (with PRESAGE(R) radiochromic plastic and optical-CT readout) and an in-house developed GPU-accelerated PENELOPE Monte-Carlo dose calculation system. Methods: {sup 60}Co IMRT subject to a 0.35T lateral magnetic field has recently been commissioned in our institution following AAPM’s TG-119 recommendations. We performed PRESAGE(R) sensitivity studies in 4ml cuvettes to verify linearity, MR-compatibility, and energy-independence. Using 10cm diameter PRESAGE(R), we delivered an open calibration field to examine the percent depth dose and a symmetrical 3-field plan with three adjacent regions of varying dose to determine uniformity within the dosimeter under a magnetic field. After initial testing, TG-119 plans were created in the TPS and then delivered to 14.5cm 2kg PRESAGE(R) dosimeters. Dose readout was performed via optical-CT at a second institution specializing in remote 3D dosimetry. Absolute dose was measured using an IBA CC01 ion chamber and the institution standard patient-specific QA methods were used to validate plan delivery. Calculated TG-119 plans were then compared with an independent Monte Carlo dose calculation (gPENELOPE). Results: PRESAGE(R) responds linearly (R{sup 2}=0.9996) to {sup 60}Co irradiation, in the presence of a 0.35T magnetic field, with a sensitivity of 0.0305(±0.003)cm{sup −1}Gy{sup −1}, within 1% of a 6MV non-MR linac irradiation (R{sup 2}=0.9991) with a sensitivity of 0.0302(±0.003)cm{sup −1}Gy{sup −1}. Analysis of TG-119 clinical plans using 3D-gamma (3%/3mm, 10% threshold) give passing rates of: HN 99.1%, prostate 98.0%, C-shape 90.8%, and multi-target 98.5%. The TPS agreed with gPENELOPE with a mean gamma passing rate of 98.4±1.5% (2%/2mm) with the z-score distributions following a standard normal distribution. Conclusion: We demonstrate for the first time that 3D remote dosimetry using both experimental and computational methods is a feasible and reliable approach to commissioning MR-IMRT, which is particularly useful for less specialized clinics in adopting this new treatment modality.

60 APPLIED LIFE SCIENCES↗

Comparison of 2 Common Radiation Therapy Techniques for Definitive Treatment of Small Cell Lung Cancer

Purpose: Two choices are widely used for radiation delivery, 3-dimensional conformal radiation therapy (3DCRT) and intensity modulated radiation therapy (IMRT). No randomized comparisons have been conducted in the setting of lung cancer, but theoretical concerns suggest that IMRT may negatively impact disease control. We analyzed a large cohort of limited-stage small-cell lung cancer (LS-SCLC) patients treated before and after institutional conversion from 3DCRT to IMRT to compare outcomes. Methods and Materials: Patients with LS-SCLC treated with definitive radiation at our institution between 2000 and 2009 were retrospectively reviewed. Both multivariable Cox regression and propensity score matching were used to compare oncologic outcomes of 3DCRT and IMRT in the context of other clinically relevant covariables. Acute and chronic toxicities associated with the 2 techniques were compared using Fisher exact and log–rank tests, respectively. Results: A total of 223 patients were treated during the study period, with 119 receiving 3DCRT and 104 receiving IMRT. Their median age was 64 years (range, 39-90 years). Median follow-up times for 3DCRT and IMRT were 27 months (range, 2-147 months) and 22 months (range, 4-83 months), respectively. Radiation modality was not associated with differences in overall survival or disease-free survival in either multivariable or propensity score-matched analyses. IMRT patients required significantly fewer percutaneous feeding tube placements (5% vs 17%, respectively, P=.005). Conclusions: IMRT was not associated with worse oncologic outcomes than those of 3DCRT. IMRT was associated with a lower rate of esophagitis-related percutaneous feeding tube placements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The tracer-BHR4 model for subgrid mixing layers

A model for the passive evolution of turbulent subgrid-scale mixing layers is developed based on the model of tracer-BHR model of Braun & Gore. The new model, tracer-BHR4, mainly differs from the previous iteration in that it aims to replicate the behavior of BHR4, instead of BHR3.1. The coefficients from BHR4 are used and a new model for mixing layer growth is developed to allow the tracer model to reproduce the de-mixing behavior seen in BHR4. Additionally, an improved timestep size controller is introduced. The new model is tested on problems containing Rayleigh-Taylor or Richtmyer-Meshkov mixing layers, and is able to reproduce the behavior of well resolved BHR4 simulations with reasonable accuracy.

97 MATHEMATICS AND COMPUTING↗

Real-time open-loop frequency response analysis of flight test data

A technique has been developed to compare the open-loop frequency response of a flight test aircraft real time with linear analysis predictions. The result is direct feedback to the flight control systems engineer on the validity of predictions and adds confidence for proceeding with envelope expansion. Further, gain and phase margins can be tracked for trends in a manner similar to the techniques used by structural dynamics engineers in tracking structural modal damping.

Bosworth, J. T.↗

Vibration testing of impact-damaged composite laminates

A new test is described that can be used to measure changes in the vibration properties of impact damaged composite materials. Impact-induced delamination was observed to significantly affect natural frequencies of vibration and damping properties in cross-ply graphite/epoxy laminates. Natural frequencies are shown to drop by as much as half of their original value, and modal damping ratios can increase by a factor of up to eight when large amounts of damage are present. A simple finite element model of the damaged impact specimens was used to predict the effect of delamination on certain vibration properties. A comparison of the finite element calculations with the experimental measurements suggests that delamination was the dominant mechanism of flexural stiffness loss resulting from the transverse impact.

Grady, Joseph E.↗

Vibration testing of impact-damaged composite laminates

A new test is described that can be used to measure changes in vibration properties of impact-damaged composite materials. Impact-induced delamination was observed to significantly affect natural frequencies of vibration and damping properties in cross-ply graphite/epoxy laminates. Natural frequencies are shown to drop by as much as half of their original value and modal damping ratios can increase by a factor of up to eight when large amounts of damage are present. A simple finite element model of the damaged impact specimens was used to predict the effect of delamination on certain vibration properties. Comparison of the finite element calculations with the experimental measurements suggests that delamination was the dominant mechanism of flexural stiffness loss resulting from the transverse impact.

Grady, J. E.↗

Parameter identification of a rotor supported in a pressurized bearing lubricated with water

A rig for testing an externally pressurized (hydrostatic), water-lubricated bearing was developed. Applying a nonsynchronous sweep frequency, rotating perturbation force with a constant amplitude as an input, rotor vibration response data was acquired in Bode and Dynamic Stiffness formats. Using this data, the parameters of the rotor/bearing system were identified. The rotor/bearing model was represented by the generalized (modal) parameters of the first lateral mode, with the rotational character of the fluid force taken into account.

Grant, John W.↗

Active Noise Control of Low Speed Fan Rotor-Stator Modes

This report describes the Active Noise Cancellation System designed by General Electric and tested in the NASA Lewis Research Center's 48 inch Active Noise Control Fan. The goal of this study was to assess the feasibility of using wall mounted secondary acoustic sources and sensors within the duct of a high bypass turbofan aircraft engine for active noise cancellation of fan tones. The control system is based on a modal control approach. A known acoustic mode propagating in the fan duct is cancelled using an array of flush-mounted compact sound sources. Controller inputs are signals from a shaft encoder and a microphone array which senses the residual acoustic mode in the duct. The canceling modal signal is generated by a modal controller. The key results are that the (6,0) mode was completely eliminated at 920 Hz and substantially reduced elsewhere. The total tone power was reduced 9.4 dB. Farfield 2BPF SPL reductions of 13 dB were obtained. The (4,0) and (4,1) modes were reduced simultaneously yielding a 15 dB modal PWL decrease. Global attenuation of PWL was obtained using an actuator and sensor system totally contained within the duct.

Sutliff, Daniel L.↗

The Effects of Comorbidity and Age on RTOG Study Enrollment in Stage III Non-Small Cell Lung Cancer Patients Who Are Eligible for RTOG Studies

Purpose: To determine the influence of measured comorbidity in Radiation Therapy Oncology Group (RTOG) combined modality therapy (CMT) study enrollment in Stage III non-small cell lung cancer (NSCLC). Methods and Materials: One hundred and seventy-one patients with a Karnofsky Performance Score {>=}70 and clinical Stage III NSCLC were analyzed retrospectively for comorbidity, RTOG study eligibility, and enrollment at initial consultation. Effect of comorbidity scores (Cumulative Illness Rating Scale) were tested on patient selection for CMT, RTOG enrollment, and overall survival. Results: Comorbidity (Grade 4; p < 0.005) and use of radiation only (p {<=} 0.001) were associated with inferior survival independent of other factors. Patient selection for CMT was affected by age ({>=}70, p < 0.001), comorbidity (severity index [SI]> 2, p = 0.001), and weight loss (>5%, p = 0.001). Thirty-three patients (19%) were enrolled in a CMT RTOG study (Group 1). Forty-nine patients (29%) were eligible but not enrolled (Group 2), and 57 (33%) were ineligible (Group 3). The most common ineligibility reasons were weight loss (67%) and comorbidity in the exclusion criteria of the RTOG studies (63%). Group 1 patients were the youngest (p = 0.02), with the lowest comorbidity scores (p < 0.001) and SI (p < 0.001) compared with Groups 2 and 3. Group 3 patients were the oldest with the most unfavorable comorbidity profile. Comorbidity scores (SI >2; p = 0.006) and age ({>=}70; p = 0.05) were independent factors influencing RTOG study enrollment in patients meeting study eligibility requirements (Groups 1 and 2). Conclusions: Comorbidity scales could be useful in stratification of patients in advanced lung cancer trials and interpretation of results particularly regarding the elderly population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗