Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Embedded Active Fiber Optic Sensing Network for Structural Health Monitoring in Harsh Environments

This report summarizes technical progress on the program “Embedded Active Fiber Optic Sensing Network for Structural Health Monitoring in Harsh Environments” funded by the National Energy Technology Laboratory of the U.S. Department of Energy, and performed by the Center for Photonics Technology at Virginia Tech. The objective of this project is to develop a first-of-a-kind technology for remote fiber optic generation and detection of acoustic waves for structural health monitoring in harsh environments. During the project period, which is from April 1, 2013 to Septemeber 30, 2016, three different acoustic generation mechanisms were studied in detail for their applications in building a fiber optic acoustic generation unit (AGU), including laser induced plasma breakdown (LIP), Erbium-doped fiber laser absorption, and metal laser absorption. By comparing the performance of the AGUs designed based on these three mechanisms and analyzing the experimental results with simulations, the metal laser absorption method was selected to build a complete fiber optic structure health monitoring (FO-SHM) system for the proposed high temperature multi-parameter structure health monitoring application. Based on the simulation of elastic wave propagation and fiber Bragg grating acoustic pulse detection, an FO-SHM element together with a completed interrogation system were designed and built. This system was first tested on an aluminum piece in the low-temperature range and successfully demonstrated its capability of multi-parameter monitoring and multi-point sensing. In the later stages of the project, the research was focused on improving the surface attachment design and preparing the FO-SHM element for high temperature environment tests. After several upgrades to the surface attachment methods, the FO-SHM element was able to work reliably up to 600oC when attached to P91 pipes, which are the target material of this project. In the final stage of this project, this FO-SHM sensing system was tested in the simulated harsh environment for its multi-parameter monitoring performance and high-temperature survivability.

20 FOSSIL-FUELED POWER PLANTS↗

Systems and methods for processing irradiation targets through a nuclear reactor

Apparatuses and methods produce radioisotopes in instrumentation tubes of operating commercial nuclear reactors. Irradiation targets may be inserted and removed from instrumentation tubes during operation and converted to radioisotopes otherwise unavailable during operation of commercial nuclear reactors. Example apparatuses may continuously insert, remove, and store irradiation targets to be converted to useable radioisotopes or other desired materials at several different origin and termination points accessible outside an access barrier such as a containment building, drywell wall, or other access restriction preventing access to instrumentation tubes during operation of the nuclear plant.

07 ISOTOPE AND RADIATION SOURCES↗

Deep Borehole Disposal: Options, Issues and Challenges - 16250

Different versions of deep borehole disposal vary in approach and detail and the differences raise issues and create options that need to be considered in the design of any practical implementation. Among the areas for which significant options exist are the size and depth of the disposal zone; container materials and design; the method and strategy for waste package deployment; filling of the annuli around the waste packages and the final sealing of the borehole. The options for these and other areas are discussed with a focus on their advantages and disadvantages and some conclusions reached that could provide guidance for the practical application of the concept. One particularly significant point is that the integrity of the final borehole seal(s) may not be required to survive for as long as is widely believed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of three-dimension microelectrode array for bioelectric measurement using the liquidmetal-micromolding technique

A method of manufacturing three-dimension microneedle electrode arrays is presented in this paper using the micromolding technology with liquid metal at room temperature, based on the physical property of the Bi-In-Sn liquid metal alloy, being its melting point especially low. Observed under scanning electron microscopy, the needle body of the electrode chip manufactured using this method has a good consistency. Skin penetration test in-vitro indicates that the microneedle electrode can pierce the stratum corneum and cross the high-impedance layer to acquire electrical signals. Electrical impedance and polarization voltage experimental results show that the electrode chips have great electric characteristics and meet the practical application demands.

36 MATERIALS SCIENCE↗

Assessing the reliability of fast Fourier transform-based crystal plasticity simulations of a polycrystalline material near a crack tip

Crystal plasticity simulations enable a physically-based description of the micromechanical fields associated with microstructural attributes in polycrystalline materials. Fast Fourier transforms implementation of crystal plasticity (CP-FFT) in periodic unit cells offers increased computational efficiency compared to traditional finite element methods (CP-FEM). Albeit, questions may arise concerning the accuracy of the CP-FFT approach given its underlying spectral framework, specifically in regards to: potential artifacts due to violating the traction-free conditions at internal free surface within the unit cell, Gibbs phenomenon near regions with sharp changes in local mechanical properties, and representation of free surfaces under the constraints imposed by the requirement of periodicity of the unit cell. This paper presents a custom massively parallelized implementation of CP-FFT. A direct comparison of simulation results for polycrystalline deformation near a crack in a Ti55531 alloy is presented between CP-FEM and CP-FFT. The micromechanical fields and slip system level values are quantified and are similar between the two methods. Up to 10% difference in the stress fields is reported at the crack tip and this value dissipates moving away from the crack tip after 5 voxels (7 µm). In conclusion, the results point towards the reliable use of CP-FFT simulations to model polycrystalline deformation with caveats based on the treatment of the discussed artifacts.

36 MATERIALS SCIENCE↗

The crystal structure, vibrational and luminescence properties of the nanocrystalline KEu(WO{sub 4}){sub 2} and KGd(WO{sub 4}){sub 2}:Eu{sup 3+} obtained by the Pechini method

The luminescent nanocrystalline KEu(WO{sub 4}){sub 2} and KGd{sub 0.98}Eu{sub 0.02}(WO{sub 4}){sub 2} have been prepared by the Pechini method. X-ray diffraction, infrared and Raman spectroscopy as well as optical spectroscopy were used to characterise the obtained materials. The crystal structure of KEu(WO{sub 4}){sub 2} was refined in I2/c space group indicating the isostructurality to KGd(WO{sub 4}){sub 2}. The size of the crystalline grains depended on the annealing temperature, increasing with the increase of the temperature. The average size of crystallites of both crystals formed at 540 deg. C was about 50 nm. Vibrational spectra showed noticeable changes as a function of size due to, among others, phonon confinement effect. Luminescence studies did not reveal significant changes for the nanocrystallites with the lowest grain size in comparison with the bulk material. The differences observed in luminescence spectra in form of slight inhomogeneous broadening of the spectral lines and increase of the hypersensitive I{sub 0-2}/I{sub 0-1} ratio point to very low symmetry of Eu{sup 3+} ions and change of the polarisation of the local vicinities of Eu{sup 3+}. X-ray diffraction, vibrational and optical studies showed that the structure of the synthesised nanocrystalline KEu(WO{sub 4}){sub 2} and KGd(WO{sub 4}){sub 2}:Eu is nearly the same as that found for the bulk material. The size-driven phase transitions were established for both compounds. - Graphical abstract: The luminescent nanocrystalline KEu(WO{sub 4}){sub 2} and KGd{sub 0.98}Eu{sub 0.02}(WO{sub 4}){sub 2} have been prepared by the Pechini method and characterise by using X-ray diffraction, infrared and Raman spectroscopy as well as optical spectroscopy. The crystal structure of KEu(WO{sub 4}){sub 2} was refined in I2/c space group indicating the isostructurality to KGd(WO{sub 4}){sub 2}. The size of the crystalline grains increases with the increase of the annealed temperature. The average size of crystallites of both crystals formed at 540 deg. C was about 50 nm. X-ray diffraction, vibrational and optical studies showed that the structure of the synthesised nanocrystalline KEu(WO{sub 4}){sub 2} and KGd(WO{sub 4}){sub 2}:Eu is nearly the same as that found for the bulk material. The size-driven phase transitions were established for both compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diffusion-weighted imaging as a part of PET/MR for small lesion detection in patients with primary abdominal and pelvic cancer, with or without TOF reconstruction technique

Objectives: To investigate the value of diffusion-weighted imaging (DWI) in detection of small lesions (≤ 10 mm) in patients with primary abdominal and pelvic cancer in hybrid PET/MR with or without time-of-flight (TOF) technique. Materials and methods: Twenty patients (11 females and 9 males, mean age 67.23 ± 12.90 years) with histologically confirmed primary abdominal and pelvic cancer underwent hybrid PET/MR examination. A total of 64 small lesions were included in this study, which were divided into two groups (≤ 10 mm and 10–30 mm). Visual scores of small lesion detection ability were rated by five-point ordinal scale. The visual scores and detectability of small lesions on TOF PET image, noTOF PET image, and DWI sequences of hybrid PET/MR examination with or without TOF technique were analyzed. Logistic regression model was established for analysis in the value of DWI in hybrid PET/MR examination with or without TOF technique in detection of the small lesions between two groups. Results: The visual evaluation revealed the small lesion (≤ 10 mm) visual scores of DWI (mean ± SD: 4.23 ± 1.41), TOF PET image (mean ± SD: 4.14 ± 0.89), and noTOF PET image (mean ± SD: 2.68 ± 1.13);.and the visual scores of small lesions (10–30 mm) on DWI (mean ± SD: 4.98 ± 0.15), TOF PET image (mean ± SD: 4.57 ± 0.59), and noTOF PET image (mean ± SD: 3.98 ± 1.05). The visual scores of all small lesions on DWI were higher than that on TOF PET data and noTOF PET data in both two groups (**P < 0.01). The missed diagnosis rates of small FDG avid lesions (≤ 10 mm) of DWI and noTOF PET image were 9.1% and 9.1%, respectively. However, the TOF PET-based clinical diagnosis detected all small lesions (≤ 30 mm). DWI was of great importance in detection of small lesions (≤ 10 mm) in the absence of TOF technique in PET/MR examination (**P < 0.01). DWI’s effect on detection of small lesions(10-30 mm) has shown no difference between PET/MR examinations with TOF and without TOF techniques (P > 0.05). Conclusion: DWI has significant value in the detection of small lesions (≤ 10 mm) in hybrid PET/MR examination without TOF technique for patients with primary abdominal and pelvic cancer. However, it had less detection benefits in the small lesions (≤ 10 mm) in hybrid PET/MR examination with TOF PET image.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irinotecan Loaded in Eluting Beads: Preclinical Assessment in a Rabbit VX2 Liver Tumor Model

Purpose: The purpose of this study was to study the pharmacokinetics of irinotecan injected intravenously, intra-arterially, or loaded onto a delivery platform. Material and Methods: Fifty-four New Zealand White rabbits with VX2 liver tumor, divided in 3 groups of 17 rabbits, each received irinotecan either by intravenous (IV) route, intra-arterial hepatic (IA) route, or loaded on drug-eluting beads (DEBIRI). Animals were killed at 1, 6, and 24 h. Irinotecan and SN-38 concentrations were measured at different time points in serum, tumor, and normal liver.ResultsTwelve milligrams of irinotecan were injected IV and IA, whereas 6-16.5 mg were injected loaded onto DEBIRI. Normalized serum irinotecan reached a peak of 333 ng/ml (range 198.8-502.5) for IV, 327.1 ng/ml (range 277.1-495.6) for IA, and 189.7 ng/ml (range 111.1-261.9) for DEBIRI (P < 0.001) delivery. The area-under-the-curve value from 10 to 60 min of serum irinotecan concentration was significantly lower for DEBIRI (P = 0.0009). Tumor irinotecan levels for IV, IA, and DEBIRI (in ng/200 mg of tissue followed by ranges in parentheses) were, respectively, 23.6 (0.3-24.9), 36.5 (7.7-1914.1), and 20.2 (2.9-319) at 1 h; 4.2 (1-27.9), 99.3 (46.6-159.5), and 42.1 (11.3-189) at 6 h; and 2.7 (2.5-6.9), 18.3 (1.5-369.1), and 174.4 (3.4-5147.3) at 24 h (P = 0.02). At 24 h, tumor necrosis was 25% (10-30), 60% (40-91.25), and 95% (76.25-95) for IV, IA, and DEBIRI, respectively (P = 0.03). Conclusion: Compared with IV or IA, DEBIRI induces lower early serum levels of irinotecan, a high and prolonged intratumoral level of irinotecan, and a greater rate of tumor necrosis at 24 h. Further evaluation of the clinical benefit of DEBIRI is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of Statistical Uncertainties in Subcritical Benchmark Measurements: Part I - Theory and Simulations

Subcritical neutron noise measurements are often used to determine multiplication of a system with Special Nuclear Material. This work presents an uncertainty approach which incorporates the singles and doubles counting rates determined by the Hage-Cifarelli formalism. This is a moments-based approach which utilizes time correlations between prompt neutrons in order to assess the system multiplication. After the method is described, a validation is presented which utilizes simulated data generated using a 0-D point-kinetics Monte Carlo code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Prospective Study of Salivary Gland Function in Lymphoma Patients Receiving Head and Neck Irradiation

Purpose: To determine the radiation dose-response relationship on salivary dysfunction and quality of life (QOL) over time in patients with lymphoma receiving radiation therapy (RT) to the head and neck (H and N). Methods and Materials: We conducted a prospective study on salivary-gland function in lymphoma patients receiving RT to the H and N. Fifteen patients were enrolled on the study. Dose-volume histograms and mean doses to the salivary glands were generated. Radiation-related toxicities and H and N-specific QOL were assessed before treatment and at prespecified time points posttreatment. Factors predicting a decrement in QOL were explored using Fisher's exact test. Results: During RT, 47% of patients experienced Grade >= 2 acute toxicity of the salivary gland, mucous membrane, or both. QOL scores improved over time, but up to one third of patients continued to have persistent oral symptoms at 2 years. At 6 months, a mean dose to at least one of the parotids of > 31 Gy was significantly associated with persistent dry mouth (100% vs. 17%, p = 0.02) and sticky saliva (100% vs. 25%, p = 0.04); a mean dose of > 11 Gy to the minor salivary glands was significantly associated with persistent sticky saliva (100% vs. 25%, p = 0.04), although the difference was no longer significant at 1 year. Conclusions: Limiting the mean parotid dose to <= 31 Gy and mean minor salivary gland dose to <= 11 Gy in lymphoma patients treated to the H and N may help reduce the risk of subacute xerostomia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uniformly 15N-Labeled Recombinant Ricin A-chain as an Internal Retention Time Standard for Increased Confidence in Forensic Identification of Ricin by Untargeted Nanoflow Liquid Chromatography-Tandem Mass Spectrometry

Ricin, a toxic protein from the castor plant, is of forensic and biosecurity interest because of its high toxicity and common occurrence in crimes and attempted crimes. Qualitative methods to detect ricin are therefore needed. Untargeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) proteomics methods are well-suited because of their high speci-ficity. Specificity in LC-MS/MS comes from both the LC and MS components. However, modern untargeted proteomics methods often use nanoflow LC, which has less reproducible retention times than standard-flow LC, making it challenging to use retention time as a point of identification in a forensic assay. We address this challenge by using retention times rela-tive to a standard, namely uniformly 15N–labeled ricin A-chain produced recombinantly in a bacterial expression system. This material, added as an internal standard prior to trypsin digestion, produces a stable isotope labeled standard for every ricin tryptic peptide in the sample. We show that the MS signals for 15N and natural isotopic abundance ricin peptides are distinct, with mass shifts that correspond to the numbers of nitrogen atoms in each peptide or fragment. We also show that, as expected, labeled and unlabeled peptides coelute, with relative retention time differences of less than 0.2%.

ricin, mass spectrometry, isotope, nitrogen-15, re↗

Update on Ultrasonic Thermometry Development at Idaho National Laboratory

The Idaho National Laboratory (INL) has initiated an effort to evaluate the viability of using ultrasonic thermometry technology as an improved sensor for detecting temperature during irradiation testing of advanced fuels proposed within the Fuel Cycle Research and Development (FCR&D) program sponsored by the U.S. Department of Energy (US DOE). Ultrasonic thermometers (UTs) work on the principle that the speed at which sound travels through a material (acoustic velocity) is dependent on the temperature of the material. UTs have several advantages over other types of temperature sensors . UTs can be made very small, as the sensor consists only of a small diameter rod which may or may not require a sheath. Measurements may be made up to very high temperature (near the melting point of the sensor material) and, as no electrical insulation is required, shunting effects observed in traditional high temperature thermocouple applications are avoided. Most attractive, however, is the ability to introduce multiple acoustic discontinuities into the sensor, as this enables temperature profiling with a single sensor. The current paper presents initial results from FCR&D UT development efforts. These developments include improved methods for fabricating magnetostrictive transducers and joining them to waveguides, characterization of candidate sensor materials appropriate for use in FCR&D fuels irradiations (both ceramic fuels in inert gas and sodium bonded metallic fuels), enhanced signal processing techniques, and tests to determine potential accuracy and resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A continuum meshfree method for sandbox-style numerical modeling of accretionary and doubly vergent wedges

Here, in this study, we introduce and utilize GEOSPH, a Lagrangian particle-based continuum Smoothed Particle Hydrodynamics (SPH) code to simulate the deformation of geologic materials in sandbox-style experiments using an elastoplastic constitutive model. Due to the meshfree nature of SPH, our proposed framework is capable of handling the large deformations characteristic of sandbox-style experiments. SPH is also able to capture strain localization and discontinuities, allowing us to resolve faulting patterns emerging in the sandbox experiments. We successfully validate our SPH implementation against the benchmark experiments of Buiter and co-workers, and then apply SPH to understand the deformational processes occurring in doubly vergent orogens resultant from the S-point experimental setup and from finitely high wedge-like indenter backstops of different inclinations. We find that the topographic slope of the prowedge results from the competing processes of vertical uplift due to the indenter and forward thrusting, while the topographic slope of the retrowedge is a product of repeated shallow slope failure. Our findings show that SPH is a promising numerical method which should be added to the current palette of computational tools used by structural geologists for solving problems relating to tectonics and crustal deformation.

58 GEOSCIENCES↗

Hydrothermal synthesis and magnetic properties of nanoplate-assembled hierarchical structured Co{sub 1-x}S microrods

Hierarchical structured Co{sub 1-x}S microrods have been first fabricated in a high yield by a one-pot complex-surfactant-assisted hydrothermal method. The microrod is assembled by numerous interleaving nanoplates. X-ray diffraction, X-ray photoelectron spectroscopy, Fourier-transform infrared spectroscopy spectrum, scanning electron microscopy, and transmission electron microscopy were used to characterize the samples. The mechanism for the formation of the hierarchical microstructures has been proposed. Additionally, the magnetic characterization suggests that the obtained Co{sub 1-x}S microrods are ferromagnetic at low temperature. - Highlights: Black-Right-Pointing-Pointer Hierarchical structured Co{sub 1-x}S microrods are fabricated by hydrothermal method. Black-Right-Pointing-Pointer The microrods are assembled by numerous interleaving nanoplates. Black-Right-Pointing-Pointer The growth mechanism of rodlike microstructures is proposed. Black-Right-Pointing-Pointer The obtained Co{sub 1-x}S microrods are ferromagnetic at low temperature.

36 MATERIALS SCIENCE↗

Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data

Purpose: To provide a method for calculating the transmission of any broad photon beam with a known energy spectrum in the range of 20–1090 keV, through concrete and lead, based on the superposition of corresponding monoenergetic data obtained from Monte Carlo simulation. Methods: MCNP5 was used to calculate broad photon beam transmission data through varying thickness of lead and concrete, for monoenergetic point sources of energy in the range pertinent to brachytherapy (20–1090 keV, in 10 keV intervals). The three parameter empirical model introduced byArcher et al. [“Diagnostic x-ray shielding design based on an empirical model of photon attenuation,” Health Phys. 44, 507–517 (1983)] was used to describe the transmission curve for each of the 216 energy-material combinations. These three parameters, and hence the transmission curve, for any polyenergetic spectrum can then be obtained by superposition along the lines of Kharrati et al. [“Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities,” Med. Phys. 34, 1398–1404 (2007)]. A simple program, incorporating a graphical user interface, was developed to facilitate the superposition of monoenergetic data, the graphical and tabular display of broad photon beam transmission curves, and the calculation of material thickness required for a given transmission from these curves. Results: Polyenergetic broad photon beam transmission curves of this work, calculated from the superposition of monoenergetic data, are compared to corresponding results in the literature. A good agreement is observed with results in the literature obtained from Monte Carlo simulations for the photon spectra emitted from bare point sources of various radionuclides. Differences are observed with corresponding results in the literature for x-ray spectra at various tube potentials, mainly due to the different broad beam conditions or x-ray spectra assumed. Conclusions: The data of this work allow for the accurate calculation of structural shielding thickness, taking into account the spectral variation with shield thickness, and broad beam conditions, in a realistic geometry. The simplicity of calculations also obviates the need for the use of crude transmission data estimates such as the half and tenth value layer indices. Although this study was primarily designed for brachytherapy, results might also be useful for radiology and nuclear medicine facility design, provided broad beam conditions apply.

61 RADIATION PROTECTION AND DOSIMETRY↗

Two-Dimensional Space-Time Dependent Multi-group Diffusion Equation with SLOR Method

The research of two-dimensional space-time diffusion equations with SLOR (Successive-Line Over Relaxation) has been done. SLOR method is chosen because this method is one of iterative methods that does not required to defined whole element matrix. The research is divided in two cases, homogeneous case and heterogeneous case. Homogeneous case has been inserted by step reactivity. Heterogeneous case has been inserted by step reactivity and ramp reactivity. In general, the results of simulations are agreement, even in some points there are differences.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single microparticle launching method using two-stage light-gas gun for simulating hypervelocity impacts of micrometeoroids and space debris

A single microparticle launching method is described to simulate the hypervelocity impacts of micrometeoroids and microdebris on space structures at the Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency. A microparticle placed in a sabot with slits is accelerated using a rifled two-stage light-gas gun. The centrifugal force provided by the rifling in the launch tube separates the sabot. The sabot-separation distance and the impact-point deviation are strongly affected by the combination of the sabot diameter and the bore diameter, and by the projectile diameter. Using this method, spherical projectiles of 1.0-0.1 mm diameter were launched at up to 7 km/s.

36 MATERIALS SCIENCE↗

Design and development of liquid filled polymeric fibers with flexure rate viscoelastic properties

The design and development of a novel category of bi-component polymeric fibers, made of a polymeric sheath and a liquid core is described. To understand and to analyze the flow of molten polymer and liquid within a spin pack, we built a macroscale analogon where co-flow of polymer and liquid is investigated systematically. The macroscale analogon is composed of a glass cylinder with a finite length and a coaxial capillary. The inner fluid flows in the capillary and at its outlet meets the outer fluid flowing inside the glass cylinder. The fluids are pumped into the setup using pressurized bottles with controlled flow rates. A high-speed camera is placed in front of the glass cylinder to record the transient and the steady flow of the two phases and the morphology of their interface during co-flow. We systematically analyzed the combination of various fluids and different injection channel geometries, and used these findings to design a customized spin pack. Extrusion trials with molten polymers and specific liquids resulted in the production of liquid filled polymeric fibers (LFF) with different amounts of liquid from 3% to 33%vol. and diameters from 150μm to 1mm. Fiber morphology has been investigated with the help of optical microscopy and computer tomography, in order to analyze both surface and core morphology. Mechanical characterization of fibers has been carried out with special care to the damping capacity of such fibers using two different methods: two point bending tests to evaluate the energy dissipation of fibers upon bending at low frequency values (0.005-0.5Hz), and analysis of vibration reduction to determine the quality factor at the resonance frequency of the 1{sup st} and 3{sup rd} vibration mode.

36 MATERIALS SCIENCE↗