Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transfer Learning Trained LSTM Models for Household Load Profile Forecasting

Grid edge renewable energy resources, such as rooftop solar photovoltaics, closely interact with consumer load profiles. Therefore, forecasting future electricity demand, ideally at the individual household level, is indispensable. In this paper, we present a transfer learning enhanced household load profile forecasting method. First, we tune a long short-term memory forecasting model to perform day-ahead prediction of household electricity load profiles. Then we improve these individualized models using transfer learning, and we use k-means clustering to create optimal source data sets. We find average improvements of 4.38% (largest improvement of 10.71%) when the entire data set was used to train the source model and 2.45% (largest improvement of 11.57%) in the mean absolute error when households were first clustered and used to train separate source models for each cluster. We find that transfer learning with clustered data can effectively boost the forecasting performance of the LSTM models. We use realistic household power measurements for 148 real residential households in Austin, Texas.

deep learning↗

NO-LESS: Near optimal curtailment strategy selection for net load balancing in micro grids

The integration of renewable energy sources such as solar PVs into micro grids has increased in recent years. However, the intermittent and unpredictable nature of renewable energy generation makes supply uncertain, in turn requiring continuous net load balancing to ensure grid stability. One technique to achieve net load balancing is curtailment, however, selection of the optimal set of curtailment strategies to achieve a targeted curtailment is NP-hard. State-of-the-art curtailment selection techniques approach this problem by either developing computationally expensive optimal curtailment strategies or reduce accuracy to generate sub-optimal solutions quickly. In this work, we develop NO-LESS: a Near OptimaL CurtailmEnt Strategy Selection algorithm. NO-LESS is a novel Fully Polynomial Time Approximation Scheme (FPTAS) which determines bounded (near optimal) curtailment strategies in a small amount of time while simultaneously satisfying practical constraints on strategy switching overhead and curtailment fairness. We perform both theoretical analysis and practical evaluation to show that NO-LESS is a scalable solution for performing net load balancing through curtailment strategy selection in Micro Grids.

14 SOLAR ENERGY↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

27 ARPA - Advanced Research Projects Agency-Energy↗

A Hydrogen Load Modeling Method for Integrated Hydrogen Energy System Planning

The integrated hydrogen energy system incorporates hydrogen energy into the power grid, which has been recognized as a promising option for reaching a 100% renewable electricity supply. It can make a profit because the hydrogen produced can be sold as fuel or used to generate electricity for grid services. In this paper, we develop a planning model for the integrated hydrogen energy system that considers the uncertainty of the load demand, the renewable energy generation, and the market prices. To calculate the hydrogen load, we simulate the refueling operations at a hydrogen fueling station over the course of one day and generate representative load profiles with K-means clustering. Moreover, the long-term profitability of the integrated system under both current and future conditions is validated in 10-year planning results.

grid service↗

A Data-Driven Framework for Residential Electric Vehicle Charging Load Profile Generation

Residential electric vehicle charging load profile is indispensable to achieve reliable control strategies for mitigating negative effects on power distribution system due to emerging electrified transportation. This paper introduces a data-driven framework of charging load profile generation for residential plug-in electric vehicles. Real world historical residential charging behavior data is utilized to construct empirical charging decision making model by using machine learning algorithm. A multiple channels method with kernel density estimation is proposed to construct probability density functions for estimating charging duration based on parking duration. A generation algorithm considering parking time and travel demand dependency is introduced to generate residential charging behaviors. This framework is extensible to generate various charging load profiles and simulate varied residential charging scenarios under different number of households and charging rates. This will be crucial for designing and validating residential charging control strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frequency Restoration of Grid-Forming Inverters in Pulse Load and Plug-in Events

This article presents a restoration technique using grid-forming inverters in an islanded microgrid during pulse load and plug-in events. In a microgrid powered by droop-controlled inverters, frequency is the variable that is accessible to all inverters for adjusting their power contributions. The problem is that the microgrid frequency deviates from its nominal value after a load change. The presented method enables the inverters to restore the frequency to the nominal value and regulate their bus voltage amplitudes. The frequency and voltage restorations are performed without communication while achieving the desired power-sharing between grid-forming inverters. The restoration is activated after detecting any active or reactive power changes. In this article, the dynamic model of an inverter equipped with enabled restoration paths is developed to verify the stability of the inverter controller under various conditions. The frequency and voltage restorations are examined during pulse load and plug-in events. Furthermore, this study is performed using a laboratory-scale islanded microgrid powered by two 208 V, 60 Hz, 5 kVA inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of Photovoltaic Module Materials and Design on Module Deformation Under Load

Quasi-static structural finite-element models of an aluminum-framed crystalline silicon photovoltaic module and a glass-glass thin-film module were constructed and validated against experimental measurements of deflection under uniform pressure loading. Specific practices in the computational representation of module assembly were identified as influential to matching experimental deflection observations. Additionally, parametric analyses using Latin hypercube sampling were performed to propagate input uncertainties related to module materials, dimensions, and tolerances into uncertainties in simulated deflection. Sensitivity analyses were performed on the uncertainty quantification datasets using linear correlation coefficients and variance-based sensitivity indices to elucidate key parameters influencing module deformation. Results identified edge tape and adhesive material properties as being strongly correlated to module deflection, suggesting that optimization of these materials could yield module stiffness gains at par with the conventionally structural parameters, such as glass thickness. This exercise verifies the applicability of finite-element models for accurately predicting mechanical behavior of solar modules and demonstrates a workflow for model-based parametric uncertainty quantification and sensitivity analysis. Finally, applications of this capability include the assessment of field environment loads, derivation of representative loading conditions for reduced-scale testing, and module design optimization, among others.

42 ENGINEERING↗

Solar Cell Metallization Wear is Sensitive to Loading Frequency

Here, we performed cyclic loading of photovoltaic laminates with precracked silicon cells to explore if and how loading frequency and contact pressure influence the ensuing gridline wear-out process. A measurement of parallel resistance across cracked gridlines on a laminated cell coupon was used as the metric for gridline electrical contact degradation. A statistical analysis of variance (ANOVA) analysis of the experimental results discerned that loading frequency is a more significant factor than contact pressure for gridline degradation.

14 SOLAR ENERGY↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoitaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Restoring Critical Loads In Resilient Distribution Systems using A Curriculum Learned Controller

In this paper, we propose a curriculum learned reinforcement learning (RL) controller to facilitate distribution system critical load restoration (CLR), leveraging RL's fast online response and its outstanding optimal sequential control capability. Like many grid control problems, CLR is complicated due to the large control action space and renewable uncertainty in a heavily constrained non-linear environment with strong intertemporal dependency. The nature of the problem oftentimes causes the RL policy to converge to a poor-performing local optimum if learned directly. To overcome this, we design a two-stage curriculum in which the RL agent will learn generation control and load restoration decision under different scenarios progressively. Via curriculum learning, the trained RL controller is expected to achieve a better control performance, with critical loads restored as rapidly and reliably as possible. Using the IEEE 13-bus test system, we illustrate the performance of the RL controller trained by the proposed curriculum-based method.

curriculum learning↗

Improving the Accuracy of Clustering Electric Utility Net Load Data using Dynamic Time Warping

Identifying patterns in electric utility net load data in a time-series format is very useful in preparing the operation for next day. Machine learning algorithms have been used in other domains and those concepts are applied in this paper on real-world net load measurement data. Clustering is the practice of grouping data with similar characteristics as determined by the distance measure. The K-means clustering algorithm is utilized here with actual electric utility data. The paper uses the standard distance measure, Euclidean distance (ED), and compares its performance against the dynamic time warping (DTW) measure. An actual case study with real data is presented, and DTW distance measure-based method observed to result better accuracy compared to the ED based method for substation net load measurements predominantly with residential customers.

clustering↗

Joint Seasonal ARMA Approach for Modeling of Load Forecast Errors in Planning Studies

To make informed and robust decisions in the probabilistic power system operation and planning process, it is critical to conduct multiple simulations of the generated combinations of wind and load parameters and their forecast errors to handle the variability and uncertainty of these time series. In order for the simulation results to be trustworthy, the simulated series must preserve the salient statistical characteristics of the real series. In this paper, we analyze day-ahead load forecast error data from multiple balancing authority locations and characterize statistical properties such as mean, standard deviation, autocorrelation, correlation between series, time-of-day bias, and time-of-day autocorrelation. We then construct and validate a seasonal autoregressive moving average (ARMA) model to model these characteristics, and use the model to jointly simulate day-ahead load forecast error series for all BAs.

Power system planning, Operations, Probabilistic m↗

Dual Inductor Hybrid Converter for Point-of-Load Voltage Regulator Modules

Achieving high-efficiency power conversion with high power density for large conversion ratio is crucially needed yet challenging in point-of-load applications because of increasing demands of loads. This paper presents a new hybrid converter to address this need. The converter uses two interleaved inductors for complete soft charging of flying capacitors to efficiently provide high output currents with no capacitor hard-charge loss. This dual inductor hybrid (DIH) converter features a smaller number of switches and more effective switch utilization than a recently reported Hybrid Dickson converter, yielding substantially less switch losses represented by smaller volt-ampere products and smaller equivalent output resistance. Converter operation principle is analyzed in detail to confirm the feasibility and benefits, and design considerations are provided to identify a practical design process. Experimental results verify the converter's operation principles and advantages with a 300-kHz 20-W prototype achieving 95.02% peak efficiency and 225 W/in 3 power density. Its advantages and performance promise a good candidate point-of-load converter architecture for demanding applications, such as in data centers, telecommunication, and high-performance digital systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sparse Control Synthesis for Uncertain Responsive Loads With Stochastic Stability Guarantees

In this report, recent studies have demonstrated the potential of flexible loads in providing frequency response services, predominantly due to their availability and cost-effectiveness. However, uncertainty and variability in various weather-related and end-use behavioral factors often impact the reliability of demand-side control performance. This work addresses this problem with the design of a demand-side control to achieve frequency response under load uncertainties. Our approach involves modeling the load uncertainties via stochastic processes that appear as both multiplicative and additive in the power system dynamics. Recently developed mean square exponential stability (MSES) results for continuous-time linear stochastic systems are applied to pose the control synthesis problem which results in an LMI-based optimization problem. Additional costs and constraints are added to the LMI-based controller synthesis to ensure MSES, improve closed-loop transient performance, maximize tolerable uncertainties, and promote sparsity in the controller. Additionally, the fundamental limitations between the tolerable uncertainties and control efforts while ensuring MSES are discussed. Further, the control synthesis problem for the case of the full-state measurement is generalized to the case of partial-state measurements. The proposed control synthesis is illustrated on an IEEE 39 bus system with rigorous studies to demonstrate the role of sparsity, closed-loop transient performance, tolerable uncertainties, and control efforts while ensuring MSES and achieving frequency response.

42 ENGINEERING↗

Distribution Feeder-Scale Fast Frequency Response via Optimal Coordination of Net-load Resources Part II: Large-Scale Demonstration

This work is the second of a two-part series in which we develop and experimentally demonstrate a hierarchical control solution for optimally coordinating thousands of deferrable loads and distributed energy resources (DERs) to provide fast frequency response (FFR) from an entire distribution feeder. In Part I, we developed and proved practical algorithms for fast, cost-based optimal dispatch and for determining the optimal amount of headroom to operate solar inverters with to support FFR dispatch while minimizing opportunity cost. Simulation results in Part I demonstrated the advantages of the hierarchical dispatch approach in being able to maintain fast solution times needed for FFR even when the problem size increases. In Part II, we implement the algorithms developed in Part I in a novel, large-scale power hardware-in-the-loop experiment including embedded controllers and more than 100 powered appliance loads and DER connected to a simulated real-world distribution system with more than 10,000 controlled devices. Experimental results from multiple scenarios confirm that the optimal FFR dispatch approach scales well and can optimally coordinate more than 10,000 net-load resources across a distribution network while achieving hardware response times within 500 ms, which is not possible using state-of-the-art optimal coordination approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reduced Order Model of Transactive Bidding Loads

Transactive energy (TE) has been identified to provide better grid efficiency and reliability by market-based transactive exchanges between energy producers and energy consumers. Simulations of TE systems are crucial to evaluate the benefits and impacts of different transactive mechanisms. However, such simulations can be time consuming due to the information exchange between various participants and complex co-simulation environments. In this paper, we develop a reduced order model to speed up the simulation of transactive systems in TE simulation platform (TESP) while achieving very low error between the reduced order and full model results. Specifically, the developed reduced order model consists of an aggregate responsive load agent which utilizes two Recurrent Neural Networks (RNNs) with Long Short-Term Memory units (LSTMs) to enable transactive elements to collectively participate in the TE system. The proposed aggregate responsive load (ARL) agent is able to produce similar transactive behaviors to the full simulation model while achieving significant simulation time reduction. Finally, we also show that the developed model enables generalization of simulation results across different dates and across different number of loads included in the simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗