Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linear response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Simplified detection and correction of critical data for ill-conditioned systems

Ill-conditioned systems arising in analysis and optimization can display a high sensitivity to numerical precision for changes and errors in data input. Such data may be in the form of system parameter input or desired system response. The ill-conditioning referred to generally arises from the lack of sufficient independent data to define a complex system or the weak sensitivity of response to source input parameters. It is shown how small errors in data and assumed fixed and known parameters can lead to highly erroneous results in ill-conditioned linear algebraic equations. A simplified detection and correction of critical input data arising in the coefficient matrix and desired response (i.e., right hand side) is proposed.

Ojalvo, Irving U.↗

Parametric identification of a vibratory system with a clearance

An analytical and experimental investigation of a vibratory system with a clearance was conducted. A finite element model and an equivalent single-degree-of-freedom closed-form solution were used to determine the dynamic parameters and response of an experimental structure interacting with a gap. The closed-form solution is obtained by taking advantage of the piecewise linearity of the system. Results from these solution methods are in agreement with experimental data. The results also suggest that the closed-form solution approximates the response of the experimental structure with accuracy greater than that of the finite element model. The closed-form solution was also used to determine the gap size of the structure. The parameter identification procedure utilized in this study appears to be simple to use and can be readily extended to other types of piecewise-linear multi-degree-of-freedom systems.

Alexander, R. M.↗

Acoustic fatigue life prediction for nonlinear structures with multiple resonant modes

An efficient method is presented for estimating the high-cycle fatigue lives of complex nonlinear structures. The procedure is based on an application of the method of equivalent linearization to construct a time-domain representation of the stress or strain response of a nonlinear structure. Fatigue estimates are obtained by processing the time-domain signal, and it is a simple matter to incorporate any damage accumulation model desired in the procedure. The method may also be applied to a wide range of complex nonlinear systems. Comparisons are presented of estimated fatigue lives for a nonlinear beam with random excitation obtained using the approximate method and using a conventional numerical simulation. The two techniques are found to give nearly identical results regardless of the level of nonlinearity. The number of calculations required in the approximate method is nearly the same as in a linear system and is not significantly affected by the type and level of nonlinearity in the structure.

Sun, J. Q.↗

Sensitivity of control-augmented structure obtained by a system decomposition method

The verification of a method for computing sensitivity derivatives of a coupled system is presented. The method deals with a system whose analysis can be partitioned into subsets that correspond to disciplines and/or physical subsystems that exchange input-output data with each other. The method uses the partial sensitivity derivatives of the output with respect to input obtained for each subset separately to assemble a set of linear, simultaneous, algebraic equations that are solved for the derivatives of the coupled system response. This sensitivity analysis is verified using an example of a cantilever beam augmented with an active control system to limit the beam's dynamic displacements under an excitation force. The verification shows good agreement of the method with reference data obtained by a finite difference technique involving entire system analysis. The usefulness of a system sensitivity method in optimization applications by employing a piecewise-linear approach to the same numerical example is demonstrated. The method's principal merits are its intrinsically superior accuracy in comparison with the finite difference technique, and its compatibility with the traditional division of work in complex engineering tasks among specialty groups.

Sobieszczanskisobieski, Jaroslaw↗

Sensitivity of control-augmented structure obtained by a system decomposition method

The verification of a method for computing sensitivity derivatives of a coupled system is presented. The method deals with a system whose analysis can be partitioned into subsets that correspond to disciplines and/or physical subsystems that exchange input-output data with each other. The method uses the partial sensitivity derivatives of the output with respect to input obtained for each subset separately to assemble a set of linear, simultaneous, algebraic equations that are solved for the derivatives of the coupled system response. This sensitivity analysis is verified using an example of a cantilever beam augmented with an active control system to limit the beam's dynamic displacements under an excitation force. The verification shows good agreement of the method with reference data obtained by a finite difference technique involving entire system analysis. The usefulness of a system sensitivity method in optimization applications by employing a piecewise-linear approach to the same numerical example is demonstrated. The method's principal merits are its intrinsically superior accuracy in comparison with the finite difference technique, and its compatibility with the traditional division of work in complex engineering tasks among specialty groups.

Sobieszczanski-Sobieski, Jaroslaw↗

The influence of nonlinear damping on the random response of panels by time domain simulation

The effects of nonlinear damping on the large-deflection response of symmetrically laminated composite panels is studied by time-domain simulation in an attempt to quantify experimentally observed phenomena. A single-mode deflection approach is used in the equations of motion and in the linear and nonlinear damping models. The probability, peak-probability, and spectral-density data are compiled for both strains and deflection. The rms responses as a function of input excitation level are also obtained and compared to linear, equivalent-linearization, and Fokker-Planck equation solutions.

Robinson, J.↗

Evaluation of a transfinite element numerical solution method for nonlinear heat transfer problems

Laplace transform techniques have been widely used to solve linear, transient field problems. A transform-based algorithm enables calculation of the response at selected times of interest without the need for stepping in time as required by conventional time integration schemes. The elimination of time stepping can substantially reduce computer time when transform techniques are implemented in a numerical finite element program. The coupling of transform techniques with spatial discretization techniques such as the finite element method has resulted in what are known as transfinite element methods. Recently attempts have been made to extend the transfinite element method to solve nonlinear, transient field problems. This paper examines the theoretical basis and numerical implementation of one such algorithm, applied to nonlinear heat transfer problems. The problem is linearized and solved by requiring a numerical iteration at selected times of interest. While shown to be acceptable for weakly nonlinear problems, this algorithm is ineffective as a general nonlinear solution method.

Cerro, J. A.↗

Non-linear dynamic compensation system

A non-linear dynamic compensation subsystem is added in the feedback loop of a high precision optical mirror positioning control system to smoothly alter the control system response bandwidth from a relatively wide response bandwidth optimized for speed of control system response to a bandwidth sufficiently narrow to reduce position errors resulting from the quantization noise inherent in the inductosyn used to measure mirror position. The non-linear dynamic compensation system includes a limiter for limiting the error signal within preselected limits, a compensator for modifying the limiter output to achieve the reduced bandwidth response, and an adder for combining the modified error signal with the difference between the limited and unlimited error signals. The adder output is applied to control system motor so that the system response is optimized for accuracy when the error signal is within the preselected limits, optimized for speed of response when the error signal is substantially beyond the preselected limits and smoothly varied therebetween as the error signal approaches the preselected limits.

Lin, Yu-Hwan↗

Fourier functional analysis for unsteady aerodynamic modeling

A method based on Fourier analysis is developed to analyze the force and moment data obtained in large amplitude forced oscillation tests at high angles of attack. The aerodynamic models for normal force, lift, drag, and pitching moment coefficients are built up from a set of aerodynamic responses to harmonic motions at different frequencies. Based on the aerodynamic models of harmonic data, the indicial responses are formed. The final expressions for the models involve time integrals of the indicial type advocated by Tobak and Schiff. Results from linear two- and three-dimensional unsteady aerodynamic theories as well as test data for a 70-degree delta wing are used to verify the models. It is shown that the present modeling method is accurate in producing the aerodynamic responses to harmonic motions and the ramp type motions. The model also produces correct trend for a 70-degree delta wing in harmonic motion with different mean angles-of-attack. However, the current model cannot be used to extrapolate data to higher angles-of-attack than that of the harmonic motions which form the aerodynamic model. For linear ramp motions, a special method is used to calculate the corresponding frequency and phase angle at a given time. The calculated results from modeling show a higher lift peak for linear ramp motion than for harmonic ramp motion. The current model also shows reasonably good results for the lift responses at different angles of attack.

Lan, C. Edward↗

Fourier functional analysis for unsteady aerodynamic modeling

A method based on Fourier analysis is developed to analyze the force and moment data obtained in large amplitude forced oscillation tests at high angles of attack. The aerodynamic models for normal force, lift, drag, and pitching moment coefficients are built up from a set of aerodynamic responses to harmonic motions at different frequencies. Based on the aerodynamic models of harmonic data, the indicial responses are formed. The final expressions for the models involve time integrals of the indicial type advocated by Tobak and Schiff. Results from linear two- and three-dimensional unsteady aerodynamic theories as well as test data for a 70-degree delta wing are used to verify the models. It is shown that the present modeling method is accurate in producing the aerodynamic responses to harmonic motions and the ramp type motions. The model also produces correct trend for a 70-degree delta wing in harmonic motion with different mean angles-of-attack. However, the current model cannot be used to extrapolate data to higher angles-of-attack than that of the harmonic motions which form the aerodynamic model. For linear ramp motions, a special method is used to calculate the corresponding frequency and phase angle at a given time. The calculated results from modeling show a higher lift peak for linear ramp motion than for harmonic ramp motion. The current model also shows reasonably good results for the lift responses at different angles of attack.

Chin, Suei↗

Coping with Trial-to-Trial Variability of Event Related Signals: A Bayesian Inference Approach

In electro-neurophysiology, single-trial brain responses to a sensory stimulus or a motor act are commonly assumed to result from the linear superposition of a stereotypic event-related signal (e.g. the event-related potential or ERP) that is invariant across trials and some ongoing brain activity often referred to as noise. To extract the signal, one performs an ensemble average of the brain responses over many identical trials to attenuate the noise. To date, h s simple signal-plus-noise (SPN) model has been the dominant approach in cognitive neuroscience. Mounting empirical evidence has shown that the assumptions underlying this model may be overly simplistic. More realistic models have been proposed that account for the trial-to-trial variability of the event-related signal as well as the possibility of multiple differentially varying components within a given ERP waveform. The variable-signal-plus-noise (VSPN) model, which has been demonstrated to provide the foundation for separation and characterization of multiple differentially varying components, has the potential to provide a rich source of information for questions related to neural functions that complement the SPN model. Thus, being able to estimate the amplitude and latency of each ERP component on a trial-by-trial basis provides a critical link between the perceived benefits of the VSPN model and its many concrete applications. In this paper we describe a Bayesian approach to deal with this issue and the resulting strategy is referred to as the differentially Variable Component Analysis (dVCA). We compare the performance of dVCA on simulated data with Independent Component Analysis (ICA) and analyze neurobiological recordings from monkeys performing cognitive tasks.

Ding, Mingzhou↗

BioSentinel ISS Control Experiment Final Investigation Summary Form

Each payload has 18 fluidic cards and each fluidic card has 16 microfluidic wells, for a total of 288 wells. Card activation occurs at different time points throughout the 6-month mission and following ground commands. At each timepoint, two fluidic cards are filled with growth medium containing nutrients and a metabolic indicator dye. In addition to card filling, the temperature of the cards increases from ~4°C (stasis mode) to 23°C to allow for cell growth. The metabolic dye changes color from blue to pink, then pink to clearin the presence of metabolically active yeast cells. The colorimetric changes and cell growth are monitored using a 3-light-emitting diode(LED)optical detection system. The optical data determines how fast the cells are able to recover after accumulating radiation damage over time.After ground command initiation, all the fluidics, thermal and optical detection steps in BioSentinel are fully automated.The biosensor response data is compared to physical dosimetry data collected onboard the same payload. This dosimeter or linear energy transfer (LET)spectrometer is based on TimePix chip technology. This chip measures the total ionizing radiation dose in addition to calculating the LET of each particle that traverses its sensor, thus allowing researchers to characterize the radiation environment around the payload.The biological response (and physical dosimetry) on ISS over time is compared to the deep space mission and to data obtained on the ground.This analysis provides insight on the biological effects of the space radiation exposure in preparation for future long-duration missions to space and inhabitation beyond low-Earth orbit (LEO).

BioSentinel↗

Translational Vestibulo-Ocular Reflex and Motion Perception During Interaural Linear Acceleration: Comparison of Different Motion Paradigms

The neural mechanisms to resolve ambiguous tilt-translation motion have been hypothesized to be different for motion perception and eye movements. Previous studies have demonstrated differences in ocular and perceptual responses using a variety of motion paradigms, including Off-Vertical Axis Rotation (OVAR), Variable Radius Centrifugation (VRC), translation along a linear track, and tilt about an Earth-horizontal axis. While the linear acceleration across these motion paradigms is presumably equivalent, there are important differences in semicircular canal cues. The purpose of this study was to compare translation motion perception and horizontal slow phase velocity to quantify consistencies, or lack thereof, across four different motion paradigms. Twelve healthy subjects were exposed to sinusoidal interaural linear acceleration between 0.01 and 0.6 Hz at 1.7 m/s/s (equivalent to 10 tilt) using OVAR, VRC, roll tilt, and lateral translation. During each trial, subjects verbally reported the amount of perceived peak-to-peak lateral translation and indicated the direction of motion with a joystick. Binocular eye movements were recorded using video-oculography. In general, the gain of translation perception (ratio of reported linear displacement to equivalent linear stimulus displacement) increased with stimulus frequency, while the phase did not significantly vary. However, translation perception was more pronounced during both VRC and lateral translation involving actual translation, whereas perceptions were less consistent and more variable during OVAR and roll tilt which did not involve actual translation. For each motion paradigm, horizontal eye movements were negligible at low frequencies and showed phase lead relative to the linear stimulus. At higher frequencies, the gain of the eye movements increased and became more inphase with the acceleration stimulus. While these results are consistent with the hypothesis that the neural computational strategies for motion perception and eye movements differ, they also indicate that the specific motion platform employed can have a significant effect on both the amplitude and phase of each.

Beaton, K. H.↗

Dynamic analysis of a magnetic bearing system with flux control

Using measured values of two-dimensional forces in a magnetic actuator, equations of motion for an active magnetic bearing are presented. The presence of geometric coupling between coordinate directions causes the equations of motion to be nonlinear. Two methods are used to examine the unbalance response of the system: simulation by direct integration in time; and determination of approximate steady state solutions by harmonic balance. For relatively large values of the derivative control coefficient, the system behaves in an essentially linear manner, but for lower values of this parameter, or for higher values of the coupling coefficient, the response shows a split of amplitudes in the two principal directions. This bifurcation is sensitive to initial conditions. The harmonic balance solution shows that the separation of amplitudes actually corresponds to a change in stability of multiple coexisting solutions.

Knight, Josiah↗

Non-Contact Linear Actuator Position Sensor Having a PID-Compensating Controller

A position sensor or controller generates a response signal in existing armature windings of an actuator and detects the response signal to determine the position of the armature. To generate the response signal, the actuator includes a sensor excitation winding near the armature. Two sensor excitation windings can be provided, above and below the armature, to cancel out z components and thus allow for a variable gap. The sensor excitation winding or windings are supplied with an excitation signal to induce the response signal in the armature windings. The response signal is derived by differentially amplifying and frequency filtering a raw output of the armature windings. The response signal is demodulated to determine position. If a position controller rather than a mere sensor is desired, the position signal can be buffered, PID compensated, amplified, and fed back to the armature windings.

Dean C Alhorn↗

Linear Parameter-Varying Control Compatible with Excitation for Real-Time Modeling

The Modeling and Control for Agile Aircraft Development project (MCAAD) seeks to reduce the time spent on wind tunnel testing and computational fluid dynamic modeling when developing control laws for new commercial and military aircraft. MCAAD uses advanced dynamic modeling procedures coupled with real-time control design which can reduce the time and cost spent on traditional aircraft development methods. This is done in-flight by using a real-time modeling procedure where programmed test inputs (PTI) deflect the aircraft control surfaces, and the responses are measured in order to create a dynamic model. This paper presents an 𝐻∞-based linear parameter-varying (LPV) control law designed on a nonlinear rigid-body dynamic model which commands control surface deflections at frequencies above the PTI frequency band. Thus the controller will not suppress the response due to the PTI. The LPV controller is compared with a previously designed Nonlinear Dynamic Inversion (NDI) controller and the coherence between the commanded control surface deflections and the PTI is plotted for both controllers. The LPV controller is shown to distort the PTI less than the NDI controller.

Luke J. Miller↗

An analysis of the frequency limitations of an Al(x)Ga(1-x)As/GaAs optical modulator

An analysis is made of the frequency response of an Al(x)Ga(1-x)As/GaAs optical modulator operating at a wavelength of 0.83 micron and utilizing the linear-optic effect in a Mach-Zehnder configuration. It is shown that, in semiconductor modulators, electroabsorption should be taken into account in optimizing the frequency response of the device. It is also shown that, by incorporating an insulator (a semiconductor with a large band gap) between the metallic electrode and the channel, the capacitance of the electroabsorptive modulator can be kept low at a reasonable value under the worst conditions.

Tabib-Azar, M.↗

Summary and Annotated Bibliography of Measurement Error Corrections with Potential Application in Future Quesst Mission Community Noise Studies

This document is motivated by likely needs of the Quesst mission community response tests, which will culminate in data collection and estimation of dose-response regression relationships for consideration by domestic and international aviation regulators. Furthermore, basic research questions evaluating interactions between rates of community annoyance, dose levels, and indicators of the presence of rattle, vibration, and startle hinge on hypothesis testing in the context of regression models. For a variety of reasons, noise doses may be known only imprecisely and may not reflect the actual level experienced by responding subjects. These differences between true dose and estimated dose, be they systematic or random, constitute covariate measurement error. Available statistics literature speaks to the impacts of measurement error on regression models, both in terms of bias in estimated coefficients and predicted values, and in terms of the loss of statistical power for hypothesis testing. Given the particulars of a categorical annoyance response variable and a continuous noise dose predictor variable subject to measurement error during testing, the emphasis of this report is on findings and methods pertinent to generalized linear (and mixed) models likely to be employed during the Quesst mission community tests. We reach the following conclusions: 1. Of four reviewed methods, structural Bayesian measurement error models and simulation extrapolation (SIMEX) may be the most readily applicable to Quesst mission community noise study objectives. 2. If warranted, a linear measurement model can help model systematic sources of measurement error that the classical measurement error does not. 3. For its ready implementation and small additional input requirements, simulation extrapolation may be ideally suited for addressing secondary research questions involving interactions between annoyance, noise dose, and other factors through hypothesis testing. 4. For their flexibility and ability to propagate uncertainty, structural Bayesian hierarchical models have great appeal for mission purposes; some care may be needed in developing appropriate probability models describing actual noise exposure during testing. An annotated bibliography logs additional papers and resources that may be of value to analysts in other projects and disciplines.

Dose-Response Model↗