Lifecycle greenhouse gas emissions for an ethanol production process based on genetically modified cyanobacteria: CO 2 sourcing options
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Smart grids are envisioned to accommodate high penetration of distributed photovoltaic (PV) generation, which may cause adverse grid impacts in terms of voltage violations. Therefore, PV Hosting capacity is being used as a planning tool to determine the maximum PV installation capacity that causes the first voltage violation and above which would require infrastructure upgrades. Additionally, traditional methods of Hosting capacity analysis are scenario based and computationally complex as they rely on iterative load flow algorithms that require investigating a large number of scenarios for accurate assessment of PV impacts. Therefore, this paper presents a computationally efficient analytical approach to compute the probability distribution of voltage change due to random behavior of randomly located multiple distributed PVs. The proposed approach is based on Spatio-temporal probabilistic voltage sensitivity analysis that exploits both spatial and temporal uncertainties associated with PV injections. Thereafter, the derived distribution is used to quantify voltage violations for various PV penetration levels and subsequently determine the hosting capacity of the system without the need to examine large number of scenarios. Results of the proposed framework are validated via conventional load flow based simulation approach on the IEEE 37 and IEEE 123 node test systems.
Ubiquitous electric vehicle adoption can drastically reduce greenhouse gas emissions (GHG) but will require equitable home charging infrastructure for all residences. Unlike single-family homes, Multi-Unit Dwellings (MUD) currently lack market share and access to nearby charging infrastructure partly due to expensive capital costs for reluctant residential property-owners. Further, this work evaluates the levelized cost of charging (LCOC) for Battery Electric Vehicles (BEVs) at MUD community charging hubs through a techno-economic analysis (TEA) that leverages real-world charging data and costs. Three different MUD charging types are investigated for a baseline and optimistic case: 1.9-kW Level 1 (L1), 6.6-kW Level 2 (L2), and 50-kW Direct Current Fast Charging (DCFC) stations under three different ownership models: resident, utility, and private company. Results demonstrate L1 and L2 chargers to be less expensive than the gasoline equivalent across the United States. Further, utility and private company ownership models, which avoid initial costs for residential property owners, result in a large LCOC premium for L1 and moderate LCOC premium for L2 relative to the resident ownership model. In contrast, DCFC is shown to be expensive for baseline scenarios but economical for optimistic scenarios especially under private company ownership. This work also performs a cradle to grave (C2G) life cycle assessment (LCA) of an average passenger BEV and gasoline conventional vehicle (CV) using yearly (grid mix & vehicle parameters), hourly (grid mix), and state-level (grid mix) resolution. Results show BEVs to have lower GHG emissions (-86% to-10%) than gasoline CVs in the contiguous U.S. Next, the system boundary of the TEA is extended to the total cost of ownership (TCO) of BEVs. The TCO is then coupled with the C2G GHG emissions to calculate the cost of GHG emissions reduction. Ultimately, the cost of GHG emissions reduction from MUD BEVs relative to gasoline CVs is shown to be negative for every scenario except baseline DCFC, meaning MUD BEV charging infrastructure can be a cost-effective endeavor to reduce GHG emissions.
Accurate predictions with quantifiable uncertainties are essential to many practical turbulent flow applications exhibiting extreme geometrical complexity and broad ranges of length and time scales. Under-resolved computer simulations are typically unavoidable in such applications, and implicit large-eddy simulation (ILES) often becomes the effective strategy. In this work, we focus on assessing ILES initialized with well-characterized 25 6 3 homogeneous isotropic turbulence datasets generated with direct numerical simulation (DNS). ILES solutions based on the LANL xRAGE code are studied as function of resolution for 6 4 3 , 12 8 3 , 25 6 3 , and 51 2 3 grids. ILES performance of new directionally-unsplit high-order numerical hydrodynamics algorithms in xRAGE is examined in this context. Compared to the initial 25 6 3 DNS, we find longer inertial subranges and higher turbulence Reynolds number (Re) for 25 6 3 and 51 2 3 xRAGE — attributed to having linked DNS (Navier–Stokes based) solutions to nominally inviscid (higher Re) Euler based ILES solutions. For fixed 25 6 3 resolution, we find that significantly larger simulated turbulence Re can be achieved with the higher-order unsplit (vs. split) discretizations.
This paper presents a coupled techno-economic and life cycle assessment of “blue” hydrogen to be produced at a hydrogen facility through steam methane reforming (SMR) equipped with carbon capture and storage (CCS). Blue hydrogen was modeled in ChemCAD, while an integrated asset model represented the carbon capture and storage chain. An unabated carbon dioxide (CO 2 ) configuration release 11.99 kgCO 2 -eq/ kgH 2 . Capturing ≥95% of the CO 2 stream lowers the carbon footprint to 6.59 kgCO 2 -eq/kgH2 but raises the levelized cost of hydrogen (LCOH) from $\$$1.82/kgH 2 (no CO 2 capture) to $\$$3.22/kgH 2 ; the U.S. 45Q tax credit reduces it to $\$$2.59/kgH 2 . Incorporating CCS reduces the levelized net present value from $\$$0.87/kgH 2 to $\$$0.74/kgH 2 , owing to additional capture, transport, and storage costs. Supplying SMR with low-carbon electricity, especially nuclear, wind, or hydro, delivers the lowest carbon footprint relative to geothermal or grid mixes. Sensitivity analysis identifies that hydrogen sales price, internal rate of return, and CCS cost as the strongest economic levers, while electricity demand dominates residual lifecycle emissions. The results underscore a clear trade-off; substantial CO 2 reductions are achievable, but only with higher production costs, making supportive policy instruments, access to clean power, and robust hydrogen markets essential for large-scale deployment of blue hydrogen.
Uncertainty quantification for nuclear theories has gained a more prominent role in the field, with more groups attempting to understand the uncertainties in their calculations. However, recent studies have shown that the uncertainties on the optical potentials are too large for the theory to be useful. The goal of this work is to explore possible experimental conditions that may reduce the uncertainties on elastic scattering and single-nucleon transfer cross sections that come from the fitting of the optical model parameters to experimental data. Using Bayesian methods, we explore the effect of the uncertainties of optical model parameters on the angular grid of the differential cross section, including cross-section data at nearby energies, and changes in the experimental error bars. We also study the effect on the resulting uncertainty when other observables are included in the fitting procedure, particularly the total (reaction) cross sections. We study proton and neutron elastic scattering on 48 Ca and 208 Pb. We explore the parameter space with the Markov-chain Monte Carlo method, produce posterior distributions for the optical model parameters, and construct the corresponding 95% confidence intervals on the elastic-scattering cross sections. We also propagate the uncertainties on the optical potentials to the 48 Ca(d,p) 49 Ca(g.s.) and 208 Pb(d,p) 209 Pb(g.s.) cross sections. We find little sensitivity to the angular grid and an improvement of up to a factor of 2 on the uncertainties by including data at a nearby energy. Although reducing the error bars on the data does reduce the uncertainty, the gain is often considerably smaller than one would naively expect. We also find that the inclusion of total reaction cross section can improve the uncertainty although the magnitude of the effect depends strongly on the cases considered.
We present the use of discrete element method (DEM) and material point method (MPM) in three relevant green technology applications that include biomass feedstock handling, lithium-ion battery manufacturing, and high-pressure reverse osmosis. Our open-source DEM and MPM solvers are developed using performance portable grid and particle management library, AMReX, thus enabling superior performance on NVIDIA and AMD GPUs with > 100 million particles. Our DEM solver resolves the motion of individual particles in a granular system and includes a bonded sphere method for modeling non-spherical particles along with Hertzian and liquid bridge-based contact models. We simulate highly variable biomass feedstock flows in large-scale hoppers for biofuel production and electrode calendering in battery manufacturing using DEM. Our simulations predict flow blockage in large scale biomass hoppers and electrode microstructure variations, thus providing valuable information for biofuel and battery manufacturers, respectively. The second half of the talk will be on MPM and its application towards pore resolved simulations of reverse osmosis membranes under compressive loads. We present a validation study of our MPM simulations with membrane microscopy imaging thus providing useful insights on membrane stability under high pressure conditions. We also present a spectral stability analysis of using linear hat, quadratic and cubic spline basis in MPM indicating regions of numerical stability.
For decades, transformer flexibility of operation has been limited to adjustable voltage ratio and, in some cases, several ratings with staged cooling. Transformers reconnectable to multiple voltage ratings have been primarily applied as emergency replacements. Other versions of “flexible transformers” were developed for continuous, long-term operation at specific sites, with application limited to large utilities. A new technology that supports today’s power systems adaptability requirements has been developed to provide not only voltage and power rating flexibility, but also an adjustable short-circuit impedance. This last, unique feature allows for a closer match to actual system operational requirements and could be used in the future to enhance resiliency and improve dynamic control of electrical grids. While the solution’s fundamentals have already been introduced in several technical forums, the intention of this article is to focus on the potential benefits of this new type of transformer and share the deployment experience of a full-scale prototype that has been in operation in a major U.S. utility since 2021
Abstract While tropical cyclones (TCs) are axisymmetric vortices to the first order, they often exhibit noteworthy structural asymmetries. These often result from environmental vertical wind shear, which tilts the vortex and induces a wavenumber 1 pattern in the circulation and precipitation fields. Reanalyses and climate models have improved in representing the TC structure and climatology, but their relatively coarse resolution and dependence on parameterized physics cast doubt on their ability to capture the asymmetric TC structure. We perform the most comprehensive process-oriented assessment of TC asymmetry to date in reanalyses. Specifically, we analyze the composite shear-relative TC structure in ERA5 and Climate Forecast System Reanalysis (CFSR), which vary in their resolutions, physical parameterization suites, and data assimilation techniques. These structures are compared with aircraft reconnaissance radar observations. In agreement with the observations, the strongest tangential winds are usually found left-of-shear, while inner core rainfall, ascent, vortex tilt, and low-level inflow are favored directly downshear or in the downshear-left quadrant. Outer rainband convection generally peaks in the downshear-right quadrant. Thermodynamic asymmetries are also apparent, with anomalous low-level moisture right-of-shear, midlevel warmth in the upshear-right quadrant (uptilt), and cloud properties suggestive of a realistic precipitation life cycle from growth to fallout. We also decompose rainfall contributions from the convective parameterization and large-scale cloud schemes and highlight the roles of vorticity advection, buoyancy advection, and diabatic processes in driving asymmetric vertical motions in the inner core and outer rainband regions. Our results suggest that process-level studies of TC asymmetry and TC–wind shear interaction under future warming are viable using climate models. Significance Statement Asymmetries are common in tropical cyclones (TCs), influencing their intensity, track, and hazards. Vertical wind shear often plays a leading-order role in causing these asymmetries. It is uncertain how well asymmetric structures and processes are captured in reanalyses and global climate models (GCMs) with grid spacings of 0.25° and coarser. In this study, we first evaluate TC asymmetry in reanalyses, which have the benefit of being forced by observations. This helps to assess whether the resolutions associated with GCMs sufficiently capture asymmetric structures and processes and motivates upcoming work with free-running GCMs to study how TC asymmetry may change in a warming climate.
One of the challenges of high granularity calorimeters, such as that to be built to cover the endcap region in the CMS Phase-2 Upgrade for HL-LHC, is that the large number of channels causes a surge in the computing load when clustering numerous digitized energy deposits (hits) in the reconstruction stage. In this article, we propose a fast and fully parallelizable density-based clustering algorithm, optimized for high-occupancy scenarios, where the number of clusters is much larger than the average number of hits in a cluster. The algorithm uses a grid spatial index for fast querying of neighbors and its timing scales linearly with the number of hits within the range considered. We also show a comparison of the performance on CPU and GPU implementations, demonstrating the power of algorithmic parallelization in the coming era of heterogeneous computing in high-energy physics.
The intermittent nature of power from renewable energy sources poses new challenges for electrical grids. This is due to the variable and uncertain nature of the power output from these resources. These features of renewable generation are becoming more relevant to energy system planning as grids reach higher penetration levels of renewable energy. In this presentation we present approaches for energy system planning based on scalable computational approaches which enable the explicit consideration of operational uncertainties in the planning process. Using multi-stage stochastic programming and the progressive hedging algorithm, we compute energy system expansion decisions on modified versions of the RTS-GMLC test system augmented with large amounts of renewable generation.
The transition towards net-zero emission poses economic, technical, and political challenges for the commercial-scale deployment of CO2 removal technologies by 2050. The opportunities for large-scale deployment will largely depend on the distinctive conditions found in the different locations of the world such as energy cost, carbon intensity of energy source, construction, transportation, and weather conditions. In this work, we focus on one of the promising negative emission technology, DAC (Direct Air Capture), and its response to different weather conditions. This work presents two potential operation scenarios: (i) natural gas standalone, (ii) grid electricity connected DAC plant. For the first time, we investigated the influence of temperature and RH (relative humidity) of the air on liquid-based DAC system and its response to carbon capture efficiency and levelized cost of carbon capture with operational sensitivity analysis. It is observed that the overall energy demand decreases from 11.1 to 8.3 GJ/ton-CO2 as the CO2 capture rate increases from 40 to 85%. We observed that a CO2 capture rate of 75% is only possible above 17°C even at 90% RH and this drops tremendously at lower temperatures. It is also observed that water evaporation in the air contactor is highest at dry and low RH as expected. The sensitivity analysis showed that weather conditions are insensitive to CO2 capture efficiency for the liquid-solvent based DAC plant for both scenarios. In addition, higher CO2 capture efficiency is achievable from lower upstream methane emissions and carbon intensity of grid electricity (for grid-connected scenario). Lastly, the levelized cost of natural gas standalone scenario varies from 239.7 to 408.8 $/t-CO2 is sensitive to temperature conditions more than relative humidity and compared to electricity grid-connected scenario, from 265.3 to 440.1 $/t-CO2.
Polymer additive manufacturing (AM) technology is rapidly growing and its transition to become an advanced manufacturing technique now offers possibilities for unconventional applications. One of these potential applications is on site additive manufacturing of power poles. During natural incidents such as storms and hurricanes, power lines can be severely damaged and there may not be sufficient spare power poles to replace. In such situations, additive manufacturing of power poles on site can offer a fast, temporary solution during emergencies. The ability of freeform manufacturing of parts with complex geometries makes large scale AM attractive for various applications; however, due to residual stress build up and need for different mechanical requirements for different applications, reinforcement of the AM feedstock is necessary. In addition to carbon and glass fibers, bio-derived fibers can also be used as a reinforcing phase, both to utilize the natural resources at the emergency area and in terms of long-term sustainability. In this project, design and additive manufacturing of a 13.1 m power pole was demonstrated. Three different feedstock material options (polystyrene, cellulose ester and polycarbonate reinforced with glass and bamboo fibers) and two different pole designs were investigated. As-printed part tensile properties both in printing and interlayer directions were measured and a power pole was printed as six pieces and put together successfully. Finally, a conceptual design of a portable power pole manufacturing approach was proposed.
Hydrogen is a versatile energy carrier that is used in a wide variety of chemical and industrial processes. Producing hydrogen using electrolysis can enable integration of multiple sectors including electricity, heating, and industrial sectors; however, the cost of producing hydrogen from electrolysis remains a challenge for encouraging greater adoption. With growing amounts of renewable generation on the California grid, there is downward pressure on wholesale electricity prices, particularly during the afternoon from photovoltaics (PV). These lower, or even potentially negative prices, challenge the business cases for new and existing PV plants. In addition, as the grid transitions to less flexible generation, there is greater need for system flexibility. To help improve the economics for both solar PV and hydrogen production using electrolyzers, we explore the benefit of combining PV and electrolysis systems. The optimal breakeven hydrogen production cost for six unique market participation configurations is calculated at six candidate locations where PV is already installed. The six market configurations include islanded, separated, retail, net energy metering (NEM), hybrid retail/wholesale and wholesale. Using the Revenue Operation and Device Optimization Model (RODeO) model, the optimal breakeven hydrogen price over the lifetime of the equipment is calculated. The cost includes production, storage, and compression in preparation for gaseous delivery trucks. Revenue streams include the sale of hydrogen, low carbon fuel standard (LCFS) credits, renewable electricity sold to the grid, and Renewable Energy Credits (REC). The costs included are the electricity costs, capital and fixed operation and maintenance cost (FOM) for the electrolyzer, PV, and storage and compression systems as well as taxes and financing costs. In addition, cost reductions are achieved through retail and wholesale rate optimization, by which electricity is purchased at the lowest price and sold, if possible, at the highest price. For all locations, the breakeven hydrogen production cost results show that, in the order of decreasing cost, the system configurations are islanded (highest), separated, NEM, retail, hybrid retail/wholesale, and wholesale (lowest). The resulting system design balances between the capital and maintenance cost components, the operation costs (i.e., electricity costs) and the additional market revenues. The integration of solar PV and electrolysis is shown to provide a mutually beneficial relationship. For PV, integration with electrolysis offers the potential to hedge against wholesale market price volatility, and integration with electrolysis may offer the potential to defer or avoid transmission investment to deliver power to the point-of-use and instead use it on-site. When compared with SMR without considering any renewable hydrogen premiums, this study finds that PV + Electrolysis systems with current costs are likely not competitive; however, with cost reductions for electrolysis equipment consistent with DOE projections, it was found that systems with wholesale market access would be competitive, largely on account of both low capital costs and low-cost electricity. The electrolysis units can provide greater flexibility than is required based on retail rate optimization, so there is an opportunity for a utility or CAISO to increase system flexibility with PV + Electrolysis systems in return for commensurate compensation. In this way, there are potentially several solutions that fall between the hybrid configuration and the wholesale configuration that could provide sufficient compensation for a PV + Electrolysis unit to compete with SMR while also providing greater flexibility to the grid.
GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.
Land use and land cover change (LULCC) represents a key process of human-Earth system interaction and has profound impacts on terrestrial ecosystem carbon cycling. As a key input for ecosystem models, future gridded LULCC data is typically spatially downscaled from regional LULCC projections by integrated assessment models, such as the Global Change Analysis Model (GCAM). The uncertainty associated with the different spatial downscaling methods and its impacts on the subsequent model projections have been historically ignored and rarely examined. This study investigated this problem using two representative spatial downscaling methods and focused on their impacts on the carbon cycle over the Arctic-Boreal Vulnerability Experiment (ABoVE) domain, where extensive LULCC is expected. Specifically, we used the Future Land Use Simulation model (FLUS) and the Demeter model to generate 0.25° gridded LULCC data (i.e., LULCC FLUS and LULCC Demeter , respectively) with the same input of regional LULCC projections from GCAM, under both the low (i.e., SSP126) and high (i.e., SSP585) greenhouse gas emission scenarios. The two sets of downscaled LULCC were used to drive the Community Land Model version 5 and prognostically simulate the terrestrial carbon cycle dynamics over the 21st century. The results suggest large spatial-temporal differences between LULCC FLUS and LULCC Demeter , and the spatial distributions of the needleleaf evergreen boreal tree, broadleaf deciduous boreal tree, broadleaf deciduous boreal shrub, and C3 arctic grass are particularly different under both SSP126 and SSP585. Additionally, the spatiotemporal differences are larger under SSP126 than SSP585, due to more intensive LULCC under SSP126 than SSP585 from GCAM projection. The differences in LULCC further lead to large discrepancies in the spatial patterns of projected gross primary productivity, ecosystem respiration, and net ecosystem exchange, which represent more than 79% of the contributions of future LULCC in 2100. Additionally, the difference in carbon flux under SSP126 is generally larger than those under SSP585. This study highlights the importance of considering the uncertainties induced by the spatial downscaling process in future LULCC projections and carbon cycle simulations.
Interactive time-varying volume visualization is challenging due to its complex spatiotemporal features and sheer size of the dataset. Recent works transform the original discrete time-varying volumetric data into continuous Implicit Neural Representations (INR) to address the issues of compression, rendering, and super-resolution in both spatial and temporal domains. However, training the INR takes a long time to converge, especially when handling large-scale time-varying volumetric datasets. In this work, we proposed F-Hash, a novel feature-based multi-resolution Tesseract encoding architecture to greatly enhance the convergence speed compared with existing input encoding methods for modeling time-varying volumetric data. The proposed design incorporates multi-level collision-free hash functions that map dynamic 4D multi-resolution embedding grids without bucket waste, achieving high encoding capacity with compact encoding parameters. Our encoding method is agnostic to time-varying feature detection methods, making it a unified encoding solution for feature tracking and evolution visualization. Experiments show the F-Hash achieves state-of-the-art convergence speed in training various time-varying volumetric datasets for diverse features. We also proposed an adaptive ray marching algorithm to optimize the sample streaming for faster rendering of the time-varying neural representation.
We’ve achieved our technical goals: (1) Perform large-scale kinetic simulations of SRS and CBET a range of plasma and laser conditions; (2) Develop a new $\delta f$-Gaussian-mixture algorithm to represent non-Maxwellian distribution functions from particle trapping and time-dependent plasma response; (3) Develop physics-based preliminary nonlinear LPI models for coupling to LRT/ Mazinisin and AMP; and (4) Begin implementation of LPI sub-grid models into Mazinisin.