Massive compression for high data rate macromolecular crystallography (HDRMX): impact on diffraction data and subsequent structural analysis

New higher-count-rate, integrating, large-area X-ray detectors with framing rates as high as 17400 images per second are beginning to be available. These will soon be used for specialized macromolecular crystallography experiments but will require optimal lossy compression algorithms to enable systems to keep up with data throughput. Some information may be lost. Can we minimize this loss with acceptable impact on structural information? To explore this question, we have considered several approaches: summing short sequences of images, binning to create the effect of larger pixels, use of JPEG-2000 lossy wavelet-based compression, and use of Hcompress, which is a Haar-wavelet-based lossy compression borrowed from astronomy. We also explore the effect of the combination of summing, binning, and Hcompress or JPEG-2000. In each of these last two methods one can specify approximately how much one wants the result to be compressed from the starting file size. These provide particularly effective lossy compressions that retain essential information for structure solution from Bragg reflections.

47 OTHER INSTRUMENTATION↗

Disclosure of the XRD pipeline software

The XRD pipeline software is a program to reduce 2D X-ray diffraction data from area detectors with advanced algorithms on automatic masking and image segmentation, which help characterization of multiple phases recorded in the data and facilitate data analysis.SF-25-114

XU, WENQIAN [Argonne National Laboratory (ANL), Ar↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Recent Cross-Section Results from MicroBooNE

MicroBooNE is a liquid argon time projection chamber in the Booster Neutrino Beam at Fermilab. The large event rate and 3 mm wire spacing of the detector provide high-statistics, precise-resolution imaging of neutrino interactions leading to low-threshold, high-efficiency event reconstruction with full angular coverage. As such, this is an ideal place to probe neutrino-argon interactions in the hundreds-of-MeV to few-GeV energy range, and to study the impact of nuclear effects through detailed measurements of hadronic final states. These proceedings present recent measurements of neutrino interactions in MicroBooNE, including inclusive charged-current interactions, neutral-pion production, and measurements of low-energy protons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fine guidance for a spaceborne telescope

Two transparent plates are mounted at equal and opposite angles in secondary optical-system housing, angles being set for optimum astigmatism correction. Rotation of secondary housing assembly and translation of detector are proportional to angular position of secondary image. Combined movement of two retains image within sagittal foci of secondary system.

Rosin, S.↗

Television observations of artificial aurora and analyses of flight data from NASA payload 12.18 NE

An accelerator nominally capable of ejecting pulses of electrons up to 6 sec in length, current to 500 ma and energy to 20 keV was flown on a rocket at 1500 October 15, 1972. The Strypi rocket was launched from the Pacific Missile Range Facility at Kauai, Hawaii. The intent was to eject electron pulses of various characteristics upwards along the magnetic field so as to produce artificial auroras in the conjugate (Southern Hemisphere) atmosphere and possibly to produce weaker auroras in the nearby atmosphere as a consequence of backscattered electrons. The accelerator package included a gas jet actuated attitude control system controlled by gyros. Attitude sensing also was accomplished by a two-axis fluxgate magnetometer, and a large foil was deployed to collect ambient electrons to neutralize the accelerator when it ejected high-energy electrons. Scientific instrumentation contained on the flight package included retarding potential analyzers, energetic electron detectors, and detectors to sense very low frequency radio noise. Image orthicon television systems and other optical sensors were operated in the conjugate region aboard two NC-135 jet aircrafts based in Samoa. Similar devices were operated at Haleakala, Hawaii, to attempt detection of auroras caused by backscattered electrons.

Davis, T. N.↗

Photo sensor array technology development

The development of an improved capability photo sensor array imager for use in a Viking '75 type facsimile camera is presented. This imager consists of silicon photodiodes and lead sulfide detectors to cover a spectral range from 0.4 to 2.7 microns. An optical design specifying filter configurations and convergence angles is described. Three electronics design approaches: AC-chopped light, DC-dual detector, and DC-single detector, are investigated. Experimental and calculated results are compared whenever possible using breadboard testing and tolerance analysis techniques. Results show that any design used must be forgiving of the relative instability of lead sulfide detectors. A final design using lead sulfide detectors and associated electronics is implemented by fabrication of a hybrid prototype device. Test results of this device show a good agreement with calculated values.

Rossman, M. W.↗

Magnetic field measurements from the solar probe

An optical system for the solar probe is described as well as its capability for improvements in spatial resolution. A magnetograph for measuring the elementary flux tube and obtaining vector geometry field geometry offers the possibility of looking for low contrast weak structure. With the probe's orbit passing over the pole, the structure of the polar field can be directly measured. The detector plane of the system receives a telecentric image of the objective. Because there is an aperture in this focal plane that can both move and change size, polarized line profiles can be obtained at arbitrary points with variable spatial resolution. The telescope microprocessor searches for the magnetic elements and then constructs the vector field.

Title, A. M.↗

Sensors for Precise Tracking

Sun-sensor optical system uses four pairs of pentaprisms to simplify alinement and reduce mechanical-stability requirements. Cross-shaped windows in field stop enhance sensitivity of signal detectors to changes in angular position. Two virtual images viewed by telescopes mark position and orientation of occulter panel. Reflector vertex, point source and corresponding virtual image are all equally spaced along a straight line.

Zehnpfenning, T. F.↗

Design and performance of 4 x 5120-element visible and 2 x 2560-element shortwave infrared multispectral focal planes

Two solid-state sensors for use in remote sensing instruments operating in the pushbroom mode are examined. The design and characteristics of the visible/near-infrared (VIS/NIR) device and the short-wavelength infrared (SWIR) device are described. The VIS/NIR is a CCD imager with four parallel sensor lines, each 1024 pixel long; the chip design and filter system of the VIS/NIR are studied. The performance of the VIS/NIR sensor with mask and its system performance are measured. The SWIR is a dual-band line imager consisting of palladium silicide Schottky-barrier detectors coupled to CCD multiplexers; the performance of the device is analyzed. The substrate materials and layout designs used to assemble the 4 x 5120-element VIS/NIR array and the 2 x 2560-element SWIR array are discussed, and the planarity of the butted arrays are verified using a profilometer. The optical and electrical characteristics, and the placement and butting accuracy of the arrays are evaluated. It is noted that the arrays met or exceed their expected performance.

Tower, J. R.↗

Molecular-Beam Epitaxy Of IrSi3

Molecular-beam epitaxy grows layers of iridium silicide (IrSi3) on silicon at temperatures of 630 to 800 degrees C. Particularly useful as photodetector material because it forms Schottky diodes having potential barriers of only 0.12 to 0.15 eV - lowest of any metal on silicon. Photodiodes sensitive to infrared radiation at wavelengths as large as 8 to 10 micrometers. New, lower formation temperature expected to enable growth of arrays of IrSi3/Si infrared detectors on Si wafers without thermally damaging image-processing circuitry integrated on wafers.

Lin, True-Lon↗

Variability in the vacuum-ultraviolet transmittance of magnesium fluoride windows

Sample window materials tested during the development of a domed magnesium fluoride detector window for the Hubble Space Telescope's Imaging Spectrograph are noted to exhibit wide variability in VUV transmittance; a test program was accordingly instituted to maximize a prototype domed window's transmittance. It is found that VUV transmittance can be maximized if the boule from which the window is fashioned is sufficiently large to allow such a component to be cut from the purest available portion of the boule.

Herzig, Howard↗

Coherent Doppler lidar for automated space vehicle rendezvous, stationkeeping and capture

The inherent spatial resolution of laser radar makes ladar or lidar an attractive candidate for Automated Rendezvous and Capture application. Previous applications were based on incoherent lidar techniques, requiring retro-reflectors on the target vehicle. Technology improvements (reduced size, no cryogenic cooling requirement) have greatly enhanced the construction of coherent lidar systems. Coherent lidar permits the acquisition of non-cooperative targets at ranges that are limited by the detection capability rather than by the signal-to-noise ratio (SNR) requirements. The sensor can provide translational state information (range, velocity, and angle) by direct measurement and, when used with any array detector, also can provide attitude information by Doppler imaging techniques. Identification of the target is accomplished by scanning with a high pulse repetition frequency (dependent on the SNR). The system performance is independent of range and should not be constrained by sun angle. An initial effort to characterize a multi-element detection system has resulted in a system that is expected to work to a minimum range of 1 meter. The system size, weight and power requirements are dependent on the operating range; 10 km range requires a diameter of 3 centimeters with overall size at 3 x 3 x 15 to 30 cm, while 100 km range requires a 30 cm diameter.

Bilbro, James A.↗

High resolution observations of the magnetic and velocity field of simple sunspots

We have observed the disk passage of relatively simple round sunspots using a narrowband filter and a large format CCD detector and have created magnetograms, Dopplergrams, and continuum images nearly simultaneously. In addition the spectral resolution of the filter allows the construction of 'spectra' for all points in the field of view. The mean inclination of the magnetic field increases from 45-50 deg to 70-75 deg across the penumbra and there is a fluctuation of the inclination angle about the mean of about 4 +/- 18 deg. The variation in inclination is large enough that substantial amounts of magnetic field are parallel to the solar surface from the mid to outer penumbra. The Evershed flow tends to occur in the regions where the magnetic field is horizontal. This suggests that the Evershed flow is confined to the regions of horizontal fields. We show that a simple sunspot model with azimuthal variations in inclination but no azimuthal variations of field strength is free from azimuthal Lorentz forces. The meridional component of the currents which arise from the azimuthal variation in inclination are parallel to the field lines. This suggests that a cylindrically symmetric magnetostatic sunspot model can be perturbed into one with azimuthal variations in inclination with some adjustment in the meridional force balance.

Title, Alan M.↗

MOSAIC: Software for creating mosaics from collections of images

We have developed a powerful, versatile image processing and analysis software package called MOSAIC, designed specifically for the manipulation of digital astronomical image data obtained with (but not limited to) two-dimensional array detectors. The software package is implemented using the Interactive Data Language (IDL), and incorporates new methods for processing, calibration, analysis, and visualization of astronomical image data, stressing effective methods for the creation of mosaic images from collections of individual exposures, while at the same time preserving the photometric integrity of the original data. Since IDL is available on many computers, the MOSAIC software runs on most UNIX and VAX workstations with the X-Windows or Sun View graphics interface.

Varosi, F.↗

Cryogenetically Cooled Field Effect Transistors for Low-Noise Systems

Recent tends in the design, fabrication and use of High-Electron-Mobility-Transistors (HEMT) in low noise amplifiers are reviewed. Systems employing these devices have achieved the lowest system noise for wavelengths greater than three millimeters with relatively modest cryogenic cooling requirements in a variety of ground and space based applications. System requirements which arise in employing such devices in imaging applications are contrasted with other leading coherent detector candidates at microwave wavelengths. Fundamental and practical limitations which arise in the context of microwave application of field effect devices at cryogenic temperatures will be discussed from a component and systems point of view.

Wollack, Edward J.↗

The Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS)

EUNIS (Extreme Ultraviolet Normal Incidence Spectrograph) is a high-efficiency extreme ultraviolet spectrometer that is expected to fly for the first time in 2004 as a sounding rocket payload. Using two independent optical systems, EUNIS will probe the structure and dynamics of the inner solar corona high spectral resolution in two wavelength regions: 17-21 nm with 3.5 pm resolution and 30-37 nm with 7 pm resolution. The long wavelength channel includes He II 30.4 nm and strong lines from Fe XI-XVI; the short wavelength channel includes strong lines of Fe IX-XIII. Angular resolution of 2 arcsec is maintained along a slit covering a full solar radius. EUNIS will have 100 times the throughput of the highly successful SERTS payloads that have preceded it. There are only two reflections in each optical channel, from the superpolished, off-axis paraboloidal primary and the toroidal grating. Each optical element is coated with a high-efficiency multilayer coating optimized for its spectral bandpass. The detector in each channel is a microchannel plate image intensifier fiber- coupled to three 1K x 1K active pixel sensors. EUNIS will obtain spectra with a cadence as short as 1 sec, allowing unprecedented studies of the physical properties of evolving and transient structures. Diagnostics of wave heating and reconnection wil be studied at heights above 2 solar radii, in the wind acceleration region. The broad spectral coverage and high spectral resolution will provide superior temperature and density diagnostics and will enable underflight calibration of several orbital instruments, including SOHO/CDS and EIT, TRACE, Solar-B/EIS, and STEREO/EUVI. EUNIS is supported by NASA through the Low Cost Access to Space Program in Solar and Heliospheric Physics.

Oegerle, William↗

Cryogenically Cooled Field Effect Transistors for Low-Noise Systems

Recent tends in the design, fabrication and use of High-Electron-Mobility-Transistors (HEMT) in low noise amplifiers are reviewed. Systems employing these devices have achieved the lowest system noise for wavelengths greater than three millimeters with relatively modest cryogenic cooling requirements in a variety of ground and space based applications. System requirements which arise in employing such devices in imaging applications are contrasted with other leading coherent detector candidates at microwave wavelengths. Fundamental and practical limitations which arise in the context of microwave application of field effect devices at cryogenic temperatures will be discussed from a component and systems point of view.

Wollack, Edward J.↗