Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high angular resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

HST/ACS Narrowband Imaging of the Kepler Supernova Remnant

We present narrowband images of the Kepler supernova remnant obtained with the Advanced Camera for Surveys aboard the Hubble Space Telescope. The images, with an angular resolution of 0.05" reveal the structure of the emitting gas in unprecedented detail. Radiative and nonradiative shocks are found in close proximity, unresolvable in gro~md-based spectra, indicating that the pre-shock medium is highly clumped. The ionization structure, traced by differences in the [0 111] to [N 11] flux ratio, varies on subarcsecond scales. The variation is due to 110th differences in shock velocity as well as gradients in the evolutionary stage of the shocks. A pro~llinent complex of knots protruding beyond the boundary of the ren~nallt in the northwest is found to consist of bright radiative knots, collected by arcuate nonradiative filaments. Based on the coincidence of the optical emission with a bright isolated knot of X-ray emission, we infer that this feature is due to a Rayleigh-Taylor finger that formed at the contact discontinuity and overtook the primary blast wave.

Sankrit, Ravi↗

Low-Energy Microfocus X-Ray Source for Enhanced Testing Capability in the Stray Light Facility

Research toward high-resolution, soft x-ray optics (mirrors and gratings) necessary for the next generation large x-ray observatories requires x-ray testing using a low-energy x-ray source with fine angular size (<1 arcsecond). To accommodate this somewhat demanding requirement, NASA Marshall Space Flight Center (MSFC) has procured a custom, windowless low-energy microfocus (approximately 0.1 mm spot) x-ray source from TruFocus Corporation that mates directly to the Stray Light Facility (SLF). MSFC X-ray Astronomy team members are internationally recognized for their expertise in the development, fabrication, and testing of grazing-incidence optics for x-ray telescopes. One of the key MSFC facilities for testing novel x-ray instrumentation is the SLF. This facility is an approximately 100-m-long beam line equipped with multiple x-ray sources and detectors. This new source adds to the already robust compliment of instrumentation, allowing MSFC to support additional internal and community x-ray testing needs.

Gaskin, Jessica↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

Full-Depth Coadds of the WISE and First-Year NEOWISE-Reactivation Images

The Near Earth Object Wide-field Infrared Survey Explorer (NEOWISE) Reactivation mission released data from its first full year of observations in 2015. This data set includes ~2.5 million exposures in each of W1 and W2, effectively doubling the amount of WISE imaging available at 3.4 μm and 4.6 μm relative to the AllWISE release. In this paper, we have created the first ever full-sky set of coadds combining all publicly available W1 and W2 exposures from both the AllWISE and NEOWISE-Reactivation (NEOWISER) mission phases. We employ an adaptation of the unWISE image coaddition framework, which preserves the native WISE angular resolution and is optimized for forced photometry. By incorporating two additional scans of the entire sky, we not only improve the W1/W2 depths, but also largely eliminate time-dependent artifacts such as off-axis scattered moonlight. We anticipate that our new coadds will have a broad range of applications, including target selection for upcoming spectroscopic cosmology surveys, identification of distant/massive galaxy clusters, and discovery of high-redshift quasars. In particular, our full-depth AllWISE+NEOWISER coadds will be an important input for the Dark Energy Spectroscopic Instrument selection of luminous red galaxy and quasar targets. Our full-depth W1/W2 coadds are already in use within the DECam Legacy Survey (DECaLS) and Mayall z-band Legacy Survey (MzLS) reduction pipelines. Finally, much more work still remains in order to fully leverage NEOWISER imaging for astrophysical applications beyond the solar system.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonequilibrium Quasiparticle Dynamics in Bi-Based Superconductors Measured by Modulation Photoexcitation Spectroscopy

We develop an orbital angular momentum (OAM) excitation pump-probe (Pp) spectroscopy and perform experiments on a Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+δ} (Bi2212) superconductor. The OAM modulation for the pump is realized by using a transverse mode conversion technique which allows to modulate the chirality of the optical OAM with a fixed polarization. The result reveals a difference of the OAM-dependent transient reflectivity changes below T{sub c}, indicating that the pump OAM can break the chiral symmetry of the superconducting (SC) state. The OAM dependences of the transient signal imply that the quasi-particle (QP) excitation with OAM enhances the SC with opposite chirality and/or suppress the SC with equal chirality. The temperature dependence of the OAM dynamics shows virtually no pairing fluctuation that usually appears in the QP dynamics observed by conventional Pp, suggesting that the nonequilibrium OAM dynamics is sensitive to the delocalized OAM associated with long range order.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CHARACTERIZING THE ATMOSPHERES OF THE HR8799 PLANETS WITH HST/WFC3

We present results from a Hubble Space Telescope (HST) program characterizing the atmospheres of the outer two planets in the HR8799 system. The images were taken over 15 orbits in three near-infrared (near-IR) medium-band filters—F098M, F127M, and F139M—using the Wide Field Camera 3. One of the three filters is sensitive to a water absorption band inaccessible from ground-based observations, providing a unique probe of the thermal emission from the atmospheres of these young giant planets. The observations were taken at 30 different spacecraft rolls to enable angular differential imaging (ADI), and the full data set was analyzed with the Karhunen–Loéve Image Projection routine, an advanced image processing algorithm adapted to work with HST data. To achieve the required high contrast at subarcsecond resolution, we utilized the pointing accuracy of HST in combination with an improved pipeline designed to combine the dithered ADI data with an algorithm designed to both improve the image resolution and accurately measure the photometry. The results include F127M (J) detections of the outer planets, HR8799b and c, and the first detection of HR8799b in the water-band (F139M) filter. The F127M photometry for HR8799c agrees well with fitted atmospheric models, resolving the longstanding difficulty in consistently modeling the near-IR flux of the planet.

79 ASTRONOMY AND ASTROPHYSICS↗

Liquid-Ring Attitude-Control System For Spacecraft

Angular momentum transferred to liquid flowing in rings of tubing. Proposed fluid-ring actuator used to orient spacecraft. Used instead of rotating inertia wheels. Meets need for pointing system of low mass, low power, and high resolution. Advantage of actuator, rings of tubing routed through existing structures, minimizing required space and mass.

Lurie, Boris J.↗

Image restoration of R136 - The dense core of NGC 2070

We present results from the application of a new seeing deconvolution technique to images of the dense core of NGC 2070 = 30 Doradus (the controversial object R136a). We utilize a new maximum entropy algorithm capable of restoring images to very high resolution, even to subpixel accuracy. Images of the object in different colors, as well as comparisons with previous speckle results, have been used to check the validity of the results. Our images of R136 have an angular resolution approaching 0.2 arcsec, better than any direct images of this object published to date, and corroborate evidence that R136a is a dense star cluster core, rather than a single ultraluminous object.

Weir, N.↗

X-Ray Computed Tomography of Apollo Drive Tube 73001 as Part of the Apollo Next Generation Sample Analysis Program

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This program was intended as a participating scientist program for these Apollo samples, as well as a preparation for upcoming lunar sample return missions (e.g., Artemis). The work began with studies of unsealed core tube 73002 [1,2] that is the upper ~35 cm of an Apollo 17 double drive tube (~70 cm total depth) collected on the landslide deposit near Lara Crater at Station 3 in the Taurus Littrow Valley. More recently the program extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dissection [5] of 73001, the lower half of the station 3 double drive tube. Sample 73001 was sealed under vacuum on the Moon in a Core Sample Vacuum Container (CSVC). In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, (2) whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a lunar drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) CSVC. XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube and whether there was an “air” gap between the Teflon cap and the CSVC. This was to ensure the Teflon cap (which immobilized the soil inside the drive tube) was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into an In-Ag alloy). Both scans will provide constraints on future work of this type, both for the design of tools used on the lunar surface during Artemis, as well as how we open future samples of this type. An unexpected finding from these engineering scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection (voids, angular fragments at the edges of the sample, etc.); and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. All 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition (they are individually triply bagged in Teflon within our N2 purged processing cabinets). Because of the dust adhering to particle exteriors, it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and bas-alts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon↗

A silicon strip detector dose magnifying glass for IMRT dosimetry

Purpose: Intensity modulated radiation therapy (IMRT) allows the delivery of escalated radiation dose to tumor while sparing adjacent critical organs. In doing so, IMRT plans tend to incorporate steep dose gradients at interfaces between the target and the organs at risk. Current quality assurance (QA) verification tools such as 2D diode arrays, are limited by their spatial resolution and conventional films are nonreal time. In this article, the authors describe a novel silicon strip detector (CMRP DMG) of high spatial resolution (200 {mu}m) suitable for measuring the high dose gradients in an IMRT delivery. Methods: A full characterization of the detector was performed, including dose per pulse effect, percent depth dose comparison with Farmer ion chamber measurements, stem effect, dose linearity, uniformity, energy response, angular response, and penumbra measurements. They also present the application of the CMRP DMG in the dosimetric verification of a clinical IMRT plan. Results: The detector response changed by 23% for a 390-fold change in the dose per pulse. A correction function is derived to correct for this effect. The strip detector depth dose curve agrees with the Farmer ion chamber within 0.8%. The stem effect was negligible (0.2%). The dose linearity was excellent for the dose range of 3-300 cGy. A uniformity correction method is described to correct for variations in the individual detector pixel responses. The detector showed an over-response relative to tissue dose at lower photon energies with the maximum dose response at 75 kVp nominal photon energy. Penumbra studies using a Varian Clinac 21EX at 1.5 and 10.0 cm depths were measured to be 2.77 and 3.94 mm for the secondary collimators, 3.52 and 5.60 mm for the multileaf collimator rounded leaf ends, respectively. Point doses measured with the strip detector were compared to doses measured with EBT film and doses predicted by the Philips Pinnacle treatment planning system. The differences were 1.1%{+-}1.8% and 1.0%{+-}1.6%, respectively. They demonstrated the high temporal resolution capability of the detector readout system, which will allow one to investigate the temporal dose pattern of IMRT and volumetric modulated arc therapy (VMAT) deliveries. Conclusions: The CMRP silicon strip detector dose magnifying glass interfaced to a TERA ASIC DAQ system has high spatial and temporal resolution. It is a novel and valuable tool for QA in IMRT dose delivery and for VMAT dose delivery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Planck 2013 results. XIII. Galactic CO emission

Rotational transition lines of CO play a major role in molecular radio astronomy as a mass tracer and in particular in the study of star formation and Galactic structure. Although a wealth of data exists for the Galactic plane and some well-known molecular clouds, there is no available high sensitivity all-sky survey of CO emission to date. Such all-sky surveys can be constructed using the Planck HFI data because the three lowest CO rotational transition lines at 115, 230 and 345 GHz significantly contribute to the signal of the 100, 217 and 353 GHz HFI channels, respectively. Two different component separation methods are used to extract the CO maps from Planck HFI data. The maps obtained are then compared to one another and to existing external CO surveys. From these quality checks the best CO maps, in terms of signal to noise ratio and/or residual contamination by other emission, are selected. Three different sets of velocity-integrated CO emission maps are produced with different trade-offs between signal-to-noise, angular resolution, and reliability. Maps for the CO J = 1 → 0, J = 2 → 1, and J = 3 → 2 rotational transitions are presented and described in detail. They are shown to be fully compatible with previous surveys of parts of the Galactic plane as well as with under-sampled surveys of the high latitude sky. The Planck HFI velocity-integrated CO maps for the J = 1 → 0, J = 2 → 1, and J = 3 →2 rotational transitions provide an unprecedented all-sky CO view of the Galaxy. These maps are also of great interest to monitor potential CO contamination of the Planck studies of the cosmological microwave background.

79 ASTRONOMY AND ASTROPHYSICS↗

TOF Electron Energy Analyzer for Spin and Angular Resolved Photoemission Spectroscopy

Current pulsed laser and synchrotron x-ray sources provide new opportunities for Time-Of- Flight (TOF) based photoemission spectroscopy to increase photoelectron energy resolution and efficiency compared to current standard techniques. The principals of photoelectron timing front formation, temporal aberration minimization, and optimization of electron beam transmission are presented. We have developed these concepts into a high resolution Electron Optical Scheme (EOS) of a TOF Electron Energy Analyzer (TOF-EEA) for photoemission spectroscopy. The EOS of the analyzer includes an electrostatic objective lens, three columns of transport lenses and a 90 degree energy band pass filter (BPF). The analyzer has two modes of operation: Spectrometer Mode (SM) with straight passage of electrons through the EOS undeflected by the BPF, allowing the entire spectrum to be measured, and Monochromator Mode (MM) in which the BPF defines a certain energy window inside the scope of the electron energy spectrum.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cathodoluminescence for the 21st century: Learning more from light

Cathodoluminescence (CL) is the emission of light from a material in response to excitation by incident electrons. The technique has had significant impact in the characterization of semiconductors, minerals, ceramics, and many nanostructured materials. Since 2010, there have been a number of innovative developments that have revolutionized and expanded the information that can be gained from CL and broadened the areas of application. While the primary historical application of CL was for spatial mapping of luminescence variations (e.g., imaging dark line defects in semiconductor lasers or providing high resolution imaging of compositional variations in geological materials), new ways to collect and analyze the emitted light have expanded the science impact of CL, particularly at the intersection of materials science and nanotechnology. Current developments include (1) angular and polarized CL, (2) advances in time resolved CL, (3) far-field and near-field transport imaging that enable drift and diffusion information to be obtained through real space imaging, (4) increasing use of statistical analyses for the study of grain boundaries and interfaces, (5) 3D CL including tomography and combined work utilizing dual beam systems with CL, and (6) combined STEM/CL measurements that are reaching new levels of resolution and advancing single photon spectroscopy. This focused review will first summarize the fundamentals and then briefly describe the state-of-the-art in conventional CL imaging and spectroscopy. We also review these recent novel experimental approaches that enable added insight and information, providing a range of examples from nanophotonics, photovoltaics, plasmonics, and studies of individual defects and grain boundaries.

14 SOLAR ENERGY↗

SPATIALLY RESOLVED M-BAND EMISSION FROM IO’S LOKI PATERA–FIZEAU IMAGING AT THE 22.8 m LBT

The Large Binocular Telescope Interferometer mid-infrared camera, LMIRcam, imaged Io on the night of 2013 December 24 UT and detected strong M-band (4.8 μm) thermal emission arising from Loki Patera. The 22.8 m baseline of the Large Binocular Telescope provides an angular resolution of ∼32 mas (∼100 km at Io) resolving the Loki Patera emission into two distinct maxima originating from different regions within Loki’s horseshoe lava lake. This observation is consistent with the presence of a high-temperature source observed in previous studies combined with an independent peak arising from cooling crust from recent resurfacing. The deconvolved images also reveal 15 other emission sites on the visible hemisphere of Io including two previously unidentified hot spots.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of the C 14 + α molecular configuration in O 18 by means of transfer and sequential decay reaction

A multinucleon transfer and cluster-decay experiment, namely 9 Be( 13 C, 18 O*→ 14 C+α)α, was performed at a beam energy of 65 MeV. Resonant states in 18O from 7 to 19 MeV, including some newly observed ones, are reconstructed with high resolution, based on the coincident detection of various combinations of the final fragments. Here, the α-decay branching ratios for 14 states are extracted from both the invariant-mass and the missing-mass measurements. Angular correlation analysis was conducted for the 10.3-MeV (4 + ) state. The present work supports the existence of the positive-parity rotational band associated with the 14 C+α molecular structure in 18 O, but the negative-parity band members were not identified.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An automated intensity-weighted brachytherapy seed localization algorithm

Brachytherapy has proven to be an effective treatment for various forms of cancer, whereby radioactive material is inserted directly into the body to maximize dosage to malignant tumors while preserving healthy tissue. In order to validate the preoperative or intraoperative dosimetric model, a postimplant evaluation procedure is needed to ensure that the locations of the implanted seeds are consistent with the planning stage. Moreover, development of an automated algorithm for seed detection and localization is necessary to expedite the postimplant evaluation process and reduce human error. Most previously reported algorithms have performed binary transforms on images before attempting to localize seeds. Furthermore, traditional approaches based upon three-dimensional seed shape parameterization and matching require high resolution imaging. The authors propose a new computationally efficient algorithm for automatic seed localization for full three-dimensional, low-resolution data sets that directly applies voxel intensity to the estimation of both seed centroid location and angular seed orientation. Computer simulations, phantom studies, and in vivo computed tomography prostate seed imaging results show that the proposed algorithm can produce reliable results even for low-resolution images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monitoring tropical cyclone intensity using wind fields derived from short-interval satellite images

Rapid scan visible images from the Visible Infrared Spin Scan Radiometer sensor on board SMS-2 and GOES-1 were used to derive high resolution upper and lower tropospheric environmental wind fields around three western Atlantic tropical cyclones (1975-78). These wind fields were used to derive upper and lower tropospheric areal mean relative vorticity and their differences, the net relative angular momentum balance and upper tropospheric mass outflow. These kinematic parameters were shown by studies using composite rawinsonde data to be strongly related to tropical cyclone formation and intensity changes. Also, the role of forced synoptic scale subsidence in tropical cyclone formation was examined. The studies showed that satellite-derived lower and upper tropospheric wind fields can be used to monitor and possibly predict tropical cyclone formation and intensity changes. These kinematic analyses showed that future changes in tropical cyclone intensity are mainly related to the "spin-up" of the storms by the net horizontal transport of relative angular momentum caused by convergence of cyclonic vorticity in the lower troposphere and to a lesser extent the divergence of anticyclone vorticity in the upper troposphere.

Rodgers, E. B.↗

Direct imaging of planetary systems with a ground-based radio telescope array

The National Radio Astronomy Observatory's proposed Millimeter Array (MMA) will bring unprecedented sensitivity, angular resolution, and image dynamic range to the millimeter wavelength region of the spectrum. An obvious question is whether such an instrument could be used to detect planets orbiting nearby stars. The techniques of aperture synthesis imaging developed for centimeter wavelength radio arrays are capable of producing images whose dynamic ranges greatly exceed the brightness ratio of a solar-type star and a Jupiter-like planet at sub-millimeter or millimeter wavelengths. The angular resolution required to separate a star and planet at a few pc distance can be obtained with baselines of several km. The greatest challenge is sensitivity. At the highest possible observing frequencies (approximately 300 GHz for typical high, dry sites, and approximately 900 GHz from the Antarctic plateau), the proposed MMA will be unable to detect the thermal emission from a Jupiter-like planet a few pc away. An upgraded MMA operating near 300 GHz with twice the currently proposed number of antennas, a 20% fractional bandwidth, and improved receivers could detect Jupiter at 4 pc in a few months. Building such an array on the Antarctic plateau and operating at approximately 900 GHz would allow Jupiter at 4 pc to be detected in approximately one day of observing time.

Jones, Dayton L.↗