Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

New method for determining heats of combustion of gaseous hydrocarbons

As a spin off of a system developed for monitoring and controlling the oxygen concentration in the Langley 8-foot High Temperature Tunnel, a highly accurate on-line technique was developed for determining heats of combustion of natural gas samples. It is based on measuring the ratio m/n, where m is the (volumetric) flowrate of oxygen required to enrich the carrier air in which the test gas flowing at the rate n is burned, such that the mole fraction of oxygen in the combustion product gases equals that in the carrier air. The m/n ratio is directly related to the heats of combustion of the saturated hydrocarbons present in the natural gas. A measurement of the m/n ratio for the test gas can provide a direct means of determination of its heat of combustion by using the calibration graph relating the m/n values for pure saturated hydrocarbons with their heats of combustion. The accuracy of the technique is determine solely by the accuracy with which the flowrates m and n can be measured and is of the order of 2 percent in the present study. The theoretical principles and experimental results are discussed.

Singh, J. J.↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of radial-splitters for improved wide-angle diffuser performance in a blowdown tunnel

Severe flow separation in the 15:1 area-ratio, 38 deg total angle conical diffuser preceding the settling-chamber of an intermittent blowdown wind tunnel was eliminated by the use of a novel radial-splitter arrangement. As a consequence, the operating life of settling-chamber screens was greatly extended and test-section flow steadiness improved, with no penalty in the tunnel running time.

Rao, D. M.↗

Fatigability and blood flow in the rat gastrocnemius-plantaris-soleus after hindlimb suspension

The hypothesis that hindlimb suspension (HS) increases the fatigability of the soleus during intense contractile activity and that the increased fatigue is associated with a reduced muscle blood flow was tested using caged control rats and rats subjected to HS for 15 days. After 15 days, either the soleus or the gastrocnemius-plantaris-soleus (G-P-S) muscle group was stimulated in situ (10 min at 100 Hz, 100 ms trains at 120/min), and in the G-P-S preparation, blood flow was measured with radiolabeled microspheres before and at 2 min and 10 min after the start of contractile activity. The results indicate that 15 days of HS resulted in increased fatigability of the soleus, but the effect was not caused by a reduced muscle blood flow.

Mcdonald, K. S.↗

Heating and flow-field studies on a straight-wing hypersonic reentry vehicle at angles of attack from 20 to 80 deg with simulation of real-gas trends

Data are presented from a series of phase-change heat transfer and flow visualization tests at Mach 7.4, 8, and 10.3 in air, Mach 19.5 in nitrogen, Mach 20.3 in helium, and Mach 6 in tetrafluoromethane (CF4) on the windward surface of a straight wing hypersonic reentry configuration for angles of attack from 20 deg to 80 deg. The results indicate that: (1) for hypersonic stream Mach numbers, the flow field over the straight-wing configuration is essentially independent of Mach number, (2) transition Reynolds number decreases with increasing angle of attack, (3) at some critical angle of attack, the wing-shock standoff distance is greatly increased and the stagnation line moves downstream from the wing leading edge, (4) value of the critical angle of attack is very sensitive to the flow shock density ratio or effective gamma, and (5) at angles of attack above the critical value for all gases, the nondimensional level of heat transfer to the wing is higher for the higher shock density ratio flows.

Hunt, J. L.↗

Investigation of Instabilities and Heat Transfer Phenomena in Supercritical Fuels at High Heat Flux and Temperatures

A series of heated tube experiments was performed to investigate fluid instabilities that occur during heating of supercritical fluids. In these tests, JP-7 flowed vertically through small diameter tubes at supercritical pressures. Test section heated length, diameter, mass flow rate, inlet temperature, and heat flux were varied in an effort to determine the range of conditions that trigger the instabilities. Heat flux was varied up to 4 BTU/sq in./s, and test section wall temperatures reached as high as 1950 F. A statistical model was generated to explain the trends and effects of the control variables. The model included no direct linear effect of heat flux on the occurrence of the instabilities. All terms involving inlet temperature were negative, and all terms involving mass flow rate were positive. Multiple tests at conditions that produced instabilities provided inconsistent results. These inconsistencies limit the use of the model as a predictive tool. Physical variables that had been previously postulated to control the onset of the instabilities, such as film temperature, velocity, buoyancy, and wall-to-bulk temperature ratio, were evaluated here. Film temperatures at or near critical occurred during both stable and unstable tests. All tests at the highest velocity were stable, but there was no functional relationship found between the instabilities and velocity, or a combination of velocity and temperature ratio. Finally, all of the unstable tests had significant buoyancy at the inlet of the test section, but many stable tests also had significant buoyancy forces.

Linne, Diane L.↗

Validation of Supersonic Film Cooling Modeling for Liquid Rocket Engine Applications

Topics include: upper stage engine key requirements and design drivers; Calspan "stage 1" results, He slot injection into hypersonic flow (air); test articles for shock generator diagram, slot injector details, and instrumentation positions; test conditions; modeling approach; 2-d grid used for film cooling simulations of test article; heat flux profiles from 2-d flat plate simulations (run #4); heat flux profiles from 2-d backward facing step simulations (run #43); isometric sketch of single coolant nozzle, and x-z grid of half-nozzle domain; comparison of 2-d and 3-d simulations of coolant nozzles (run #45); flowfield properties along coolant nozzle centerline (run #45); comparison of 3-d CFD nozzle flow calculations with experimental data; nozzle exit plane reduced to linear profile for use in 2-d film-cooling simulations (run #45); synthetic Schlieren image of coolant injection region (run #45); axial velocity profiles from 2-d film-cooling simulation (run #45); coolant mass fraction profiles from 2-d film-cooling simulation (run #45); heat flux profiles from 2-d film cooling simulations (run #45); heat flux profiles from 2-d film cooling simulations (runs #47, #45, and #47); 3-d grid used for film cooling simulations of test article; heat flux contours from 3-d film-cooling simulation (run #45); and heat flux profiles from 3-d and 2-d film cooling simulations (runs #44, #46, and #47).

Morris, Christopher I.↗

Seeded gas thrusters and related system components

A program involved with the construction and test of a number of laser heated thrusters is described. These thrusters, with a cavity approximately 23 cm long and 3.5 cm in i.d., are to be tested by NASA at a later date with a laser beam focused through the throat to heat hydrogen propellant containing an opacifier. The heated propellant exhausts through a supersonic nozzle with a 0.6 cm throat at 3000 C. Thrust stands and control systems were furnished with the thrusters. The report describes radio frequency plasma heated hot and cold flow simulation tests by the contractor.

Poole, J. W.↗

Hybrid Wing Body Model Identification Using Forced-Oscillation Water Tunnel Data

Static and dynamic testing of the NASA 0.7 percent scale Hybrid Wing Body (HWB) configuration was conducted in the Rolling Hills Research Corporation water tunnel to investigate aerodynamic behavior over a large range of angle-of-attack and to develop models that can predict aircraft response in nonlinear unsteady flight regimes. This paper reports primarily on the longitudinal axis results. Flow visualization tests were also performed. These tests provide additional static data and new dynamic data that complement tests conducted at NASA Langley 14- by 22-Foot Subsonic Tunnel. HWB was developed to support the NASA Environmentally Responsible Aviation Project goals of lower noise, emissions, and fuel burn. This study also supports the NASA Aviation Safety Program efforts to model and control advanced transport configurations in loss-of-control conditions.

Murphy, Patrick C.↗

Free jet feasibility study of a thermal acoustic shield concept for AST/VCE application-dual flow. Comprehensive data report. Volume 1: Test nozzles and acoustic data

Acoustic and diagnostic data that were obtained to determine the influence of selected geometric and aerodynamic flow variables of coannular nozzles with thermal acoustic shields are summarized in this comprehensive data report. A total of 136 static and simulated flight acoustic test points were conducted with 9 scale-model nozzles The tested nozzles included baseline (unshielded), 180 deg shielded, and 360 deg shielded dual flow coannular plug configurations. The baseline configurations include a high radius ratio unsuppressed coannular plug nozzle and a coanuular plug nozzle and a coannular plug nozzle with a 20-chute outer stream suppressor. The tests were conducted at nozzle temperatures and pressure typical of operating conditions of variable cycle engine.

Janardan, B. A.↗

Monitoring a large-volume injection at Cranfield, Mississippi—Project design and recommendations (SECARB Integrated Results Study)

Injection and storage of 4 million metric tons of CO 2 have been monitored to observe multiphase fluid flow, to test technologies, to document permanence of storage, and to advance techniques for capacity estimation. The injection interval is the 3000-m-deep fluvial Tuscaloosa Formation at a structural closure that defines the Cranfield oilfield. Tests were conducted in the oil-producing area as well as in the downdip brine aquifer. These tests assessed the feasibility, operation, and sensitivity ofmonitoring using a selection oftools in the vadose zone, in the shallow groundwater, above the injection zone, and within the injection zone. Although each monitoring approach merits a separate, detailed analysis, this paper assesses the success of the overall strategy for monitoring and presents an overview of conclusions from multiple data sets. Comparisons of modeled to observed reservoir response highlight the difficulties encountered in uniquely explaining measured pressure and fluid saturation measurements at interwell and field scales. Results of this study provide a cautionary note to regulatory and accreditation end users about the feasibility of obtaining unique and quantitative matches between fluid flow models and field measurements.

54 ENVIRONMENTAL SCIENCES↗

Extracting Uranium from Seawater: Promising AI Series Adsorbents

A new series of adsorbents (AI10 through AI17) were successfully developed at ORNL by radiation induced graft polymerization (RIGP) of acrylonitrile (AN) and vinylphosphonic acid (VPA) (at different mole to mole ratios) onto high surface area polyethylene fiber, with high degrees of grafting (DOG) varying from 110 to 300%. The grafted nitrile groups were converted to amidoxime groups by reaction with 5 wt % hydroxylamine at 80 °C for 72 h. The amidoximated adsorbents were then conditioned with 0.44 M KOH at 80 °C followed by screening at ORNL with prescreening brine spiked with 8 ppm uranium. Uranium adsorption capacities in prescreening ranged from 171 to 187 g-U/kg-ads irrespective of percent DOG. The performance of the adsorbents with respect to uranium adsorption in natural seawater was also investigated using flow-throughcolumn testing at the Pacific Northwest National Laboratory (PNNL). Three hours of KOH conditioning led to higher uranium uptake than 1 h of conditioning. The adsorbent AI11, containing AN and VPA at the mole ratio of 3.52, emerged as the potential candidate for the highest uranium adsorption (3.35 g-U/kg-ads.) after 56 days of exposure in seawater flow-through-columns. The rate of vanadium adsorption over uranium linearly increased throughout the 56 days of exposure. The total mass of vanadium uptake was ~5 times greater than uranium after 56 days.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental and analytical study of one- and two-component flows in spherical chambers

A study was conducted to evaluate techniques for obtaining high inner-gas concentrations in a spherical cavity for application to the open-cycle gaseous-core nuclear rocket. The study included flow visualization tests with water and gases as the working fluids, calculations of the streamline distribution, and calculation and measurement of the inner-gas concentration with air and Freon-11 as the inner-stream gases. The cavity shape, the outer-stream injection conditions, the turbulent transport coefficients, and the buoyancy effects were found to affect the inner-stream flow patterns.

Johnson, B. V.↗

Thermal Hydraulic Effect of Fuel Plate Surface Roughness

This study presents surface roughness measurements characteristic of the pre-film layer applied to a typical Advanced Test Reactor (ATR) fuel plate. This data is used to estimate the friction factor for thermal hydraulic flow calculations of a Gas Test Loop (GTL) system proposed for incorporation into ATR to provide a fast neutron flux environment for the testing of nuclear fuels and materials. To attain the required neutron flux, the design includes booster fuel plates clad with the same aluminum alloy as the ATR driver fuel and cooled with water supplied by the ATR primary coolant pumps. The objectives of this study are to: (1) determine the surface roughness of the protective boehmite layer applied to the ATR driver fuel prior to reactor operations in order to specify the machining tolerances for the surface finish on simulated booster fuel plates in a GTL hydraulic flow test model, and (2) assess the consequent thermal hydraulic impact due to surface roughness on the coolability of the booster fuel with a similar pre-film layer applied. While the maximum roughness of this coating is specified to be 1.6 µm (63 microinches), no precise data on the actual roughness were available. A representative sample coupon autoclaved with the ATR driver fuel to produce the pre-film coating was analyzed using optical profilometry. Measurements yielded a mean surface roughness of 0.53 µm (21 microinches). Results from a sensitivity study show that a ±15% deviation from the mean measured surface finish would have a minimal effect on coolant temperature, coolant flow rate, and fuel temperature. However, frictional losses from roughnesses greater than 1.5 µm (~60 microinches) produce a marked decrease in flow rate, causing fuel and coolant temperatures to rise sharply.

36 MATERIALS SCIENCE↗

Characterizing soil preferential flow using iodine--starch staining experiments and the active region model

Thirteen iodine-starch staining experiments with different boundary conditions and measurement scales were conducted at two sites to study preferential flow processes in natural unsaturated soils. Digital imaging analyses were implemented to obtain the corresponding preferential flow patterns. The test results are used to evaluate a recently proposed active region model in terms of its usefulness and robustness for characterizing unsaturated flow processes at field scale. Test results provide useful insights into flow patterns in unsaturated soils. They show that flow pattern depends on the top boundary condition. As the total infiltrating-water depth increased form 20 mm to 80 mm for the 100 x 100 cm{sup 2} plots, the corresponding flow pattern changed from few preferential flow paths associated with a relatively small degree of stained coverage and a small infiltration depth, to a pattern characterized by a higher stained coverage and a larger infiltration depth, and to (finally) a relatively homogeneous flow pattern with few unstained area and a much larger infiltration depth. Test results also show that the preferential flow pattern became generally more heterogeneous and complex for a larger measurement scale (or size of infiltration plot). These observations support the general idea behind the active region model that preferential flow pattern in unsaturated soils are dynamic and depend on water flow conditions. Further analyses of the test results indicate that the active-region model is able to capture the major features of the observed flow pattern at the scale of interest, and the determined parameter values do not significantly depend on the test conditions (initial water content and total amount of infiltrating water) for a given test site. This supports the validity of the active region model that considers that parameter to be a property of the corresponding unsaturated soil. Results also show that some intrinsic relation seems to exist between active-fracture-model parameter and a random-cascade-model parameter. (The latter model is also developed based on the existence of the fractal flow pattern in unsaturated soils.) Furthermore, our test results demonstrate that the active-region-model parameter is not scale-dependent for a range of scales under consideration. Although further studies are needed to confirm this finding, it seems to be consistent with a consideration that some fractal parameters (e.g., fractal dimension) are universal for a large range of scales.

54 ENVIRONMENTAL SCIENCES↗

Transonic Drag Reduction Through Trailing-Edge Blowing on the FAST-MAC Circulation Control Model

A third wind tunnel test of the FAST-MAC circulation control semi-span model was completed in the National Transonic Facility at the NASA Langley Research Center where the model was configured for transonic testing of the cruise configuration with 0deg flap detection to determine the potential for transonic drag reduction with the circulation control blowing. The model allowed independent control of four circulation control plenums producing a high momentum jet from a blowing slot near the wing trailing edge that was directed over a 15% chord simple-hinged ap. Recent upgrades to transonic semi-span flow control testing at the NTF have demonstrated an improvement to overall data repeatability, particularly for the drag measurement, that allows for increased confidence in the data results. The static thrust generated by the blowing slot was removed from the wind-on data using force and moment balance data from wind-o thrust tares. This paper discusses the impact of the trailing-edge blowing to the transonic aerodynamics of the FAST-MAC model in the cruise configuration, where at flight Reynolds numbers, the thrust-removed corrected data showed that an overall drag reduction and increased aerodynamic efficiency was realized as a consequence of the blowing.

Chan, David T.↗

Permeation testing of thermal power plant cooling water impacts of Graphite Oxide (GO)/polymer membranes

The purpose of this project was to investigate how thermoelectric power plant cooling water impacts the energy demands, permeance, and ion rejection of GO/polymer membranes using extended permeation testing. Treatment of cooling tower blowdown water is challenging since this water contains scalants (e.g.: silica, calcium sulfate, calcium carbonate) which can precipitate on membranes, decreasing membrane efficiency and lifetime. In this collaboration with EPRI and a Southwestern US utility, the performance of GO/polymer membranes in desalinating cooling tower blowdown water from three natural-gas fueled power plants was evaluated. Results of cross-flow desalination test durations of three to four weeks demonstrated the long-term stability of the membranes. GO/polymer desalination membranes were shown to tolerate drinking-water level chlorination, which could reduce capital and operational costs. Biofouling and scale formation were minimal on the GO surface, suggesting that industry standard intensive cleaning steps could be reduced. Results also demonstrated pressure-tunable rejection which would allow treat-to-need water recycling, thus likely reducing energy costs for these membranes. Further development of biofouling and scaling resistant desalination membranes could lead to reduced cost for water treatment, potentially allowing for greater use of non-traditional water supplies for thermoelectric power plants.

Biedermann, Laura↗

Langley Mach 4 scramjet test facility

An engine test facility was constructed at the NASA Langley Research Center in support of a supersonic combustion ramjet (scramjet) technology development program. Hydrogen combustion in air with oxygen replenishment provides simulated air at Mach 4 flight velocity, pressure, and true total temperature for an altitude range from 57,000 to 86,000 feet. A facility nozzle with a 13 in square exit produces a Mach 3.5 free jet flow for engine propulsion tests. The facility is described and calibration results are presented which demonstrate the suitability of the test flow for conducting scramjet engine research.

Earl H Andrews Jr.↗