Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Self-interaction correction in water–ion clusters

We study the importance of self-interaction errors in density functional approximations for various water–ion clusters. We have employed the Fermi-Löwdin orbital self-interaction correction (FLOSIC) method in conjunction with LSDA, PBE, and SCAN to describe binding energies of hydrogen-bonded water–ion clusters, i.e., water–hydronium, water– hydroxide, water–halide, as well as non-hydrogen-bonded water–alkali clusters. In the hydrogen-bonded water–ion clusters, the building blocks are linked by hydrogen atoms, although the links are much stronger and longer-ranged than the normal hydrogen bonds between water molecules, because the monopole on the ion interacts with both permanent and induced dipoles on the water molecules. We find that self-interaction errors overbind the hydrogen-bonded water– ion clusters and that FLOSIC reduces the error and brings the binding energies into closer agreement with higher–level calculations. Here, the non-hydrogen-bonded water–alkali clusters are not significantly affected by self-interaction errors. Self-interaction corrected PBE predicts the lowest mean unsigned error in binding energies (≤ 50 meV/H 2 O) for hydrogen-bonded water–ion clusters. Self-interaction errors are also largely dependent on the cluster size, and FLOSIC does not accurately capture the subtle variation in all clusters, indicating the need for further refinement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ab initio O(N) elongation-counterpoise method for BSSE-corrected interaction energy analyses in biosystems

An Elongation-counterpoise (ELG-CP) method was developed for performing accurate and efficient interaction energy analysis and correcting the basis set superposition error (BSSE) in biosystems. The method was achieved by combining our developed ab initio O(N) elongation method with the conventional counterpoise method proposed for solving the BSSE problem. As a test, the ELG-CP method was applied to the analysis of the DNAs’ inter-strands interaction energies with respect to the alkylation-induced base pair mismatch phenomenon that causes a transition from G⋯C to A⋯T. It was found that the ELG-CP method showed high efficiency (nearly linear-scaling) and high accuracy with a negligibly small energy error in the total energy calculations (in the order of 10{sup −7}–10{sup −8} hartree/atom) as compared with the conventional method during the counterpoise treatment. Furthermore, the magnitude of the BSSE was found to be ca. −290 kcal/mol for the calculation of a DNA model with 21 base pairs. This emphasizes the importance of BSSE correction when a limited size basis set is used to study the DNA models and compare small energy differences between them. In this work, we quantitatively estimated the inter-strands interaction energy for each possible step in the transition process from G⋯C to A⋯T by the ELG-CP method. It was found that the base pair replacement in the process only affects the interaction energy for a limited area around the mismatch position with a few adjacent base pairs. From the interaction energy point of view, our results showed that a base pair sliding mechanism possibly occurs after the alkylation of guanine to gain the maximum possible number of hydrogen bonds between the bases. In addition, the steps leading to the A⋯T replacement accompanied with replications were found to be unfavorable processes corresponding to ca. 10 kcal/mol loss in stabilization energy. The present study indicated that the ELG-CP method is promising for performing effective interaction energy analyses in biosystems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing the Impact of Soft Errors Affecting Floating-point ALUs using RTL-level Fault Injection

Strategies to detect, correct, or mitigate the impact of soft errors rely on errors-injection experiments. For efficient evaluation, such experiments typically inject errors in software by sampling errors from a candidate distribution. Most often, these strategies randomly select and flip one bit in the output of an instruction. While single-bit flips might constitute a meaningful model for errors affecting hardware, the appropriateness of this model for software-based errors has not been studied. In this paper, we study the manifestation of errors in the output registers due to errors affecting candidate instructions executed by floating point ALUs. We inject single-bit flips into the RTL descriptions of floating point ALUs and analyze the differences between anticipated and observed outputs when executing floating-point addition, subtraction, multiplication, and division. We choose the operands for these instructions randomly and from operands observed in five benchmarks. We observe a rich distribution of errors in the output and analyze their implications for software-based fault-injection campaigns.

Subasi, Omer↗

Erratum: Measurement of azimuthal asymmetries in inclusive production of hadron pairs in e⁺e⁻ annihilation at √s=10.58 GeV [Phys. Rev. D 78, 032011 (2008)]

In the original article, it was found in Monte Carlo simulations that the reconstructed A₀ results are roughly consistent with the generated asymmetries, while the A₁₂ results systematically underestimate the generated asymmetries. This underestimation can be attributed to the difference between the reconstructed thrust axis and the original quark-antiquark axis. The corresponding correction factors are 1.6 ± 0.04 for the A₁₂ results and 1.11 ± 0.05 for the A₀ results. Because of a flaw in the original analysis program, these correction factors were not applied to the A UC -type asymmetries in Table V as well as in some figures. In addition, a small mistake in the error propagation in the charm correction resulted in slightly underestimated statistical uncertainties. These omissions affect all but the charm asymmetry results. The correct central values are therefore given in Tables IV and V of this Erratum. The systematic uncertainties of the original publication remain unchanged.

Seidl, R.↗

On the atomic line profiles in high pressure plasmas

In a previous contribution to this journal [H. P. Stormberg, J. Appl. Phys. 51(4), 1963 (1980)], Stormberg presented an analytical expression for the convolution of Lorentz and Levy line profiles, which models atomic radiative transitions in high pressure plasmas. Unfortunately, the derivations are flawed with errors and the final expression, while correct, is accompanied by misguiding comments about the meaning of the symbols used therein, in particular the “complex error function.” In this paper, we discuss the broadening mechanisms that give rise to Stormberg's model and present a correct derivation of his final result. We will also provide an alternative expression, based on the Faddeeva function, which has decisive computational advantages and emphasizes the real-valuedness of the result. The MATLAB/Octave scripts of our implementation have been made available on the publisher's website for future reference.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absolute Cavity Pyrgeometer to Measure the Absolute Outdoor Longwave Irradiance with Traceability to International System of Units, SI

This article describes a method of measuring the absolute outdoor longwave irradiance using an absolute cavity pyrgeometer (ACP), U.S. Patent application no. 13/049, 275. The ACP consists of domeless thermopile pyrgeometer, gold-plated concentrator, temperature controller, and data acquisition. The dome was removed from the pyrgeometer to remove errors associated with dome transmittance and the dome correction factor. To avoid thermal convection and wind effect errors resulting from using a domeless thermopile, the gold-plated concentrator was placed above the thermopile. The concentrator is a dual compound parabolic concentrator (CPC) with 180{sup o} view angle to measure the outdoor incoming longwave irradiance from the atmosphere. The incoming irradiance is reflected from the specular gold surface of the CPC and concentrated on the 11 mm diameter of the pyrgeometer's blackened thermopile. The CPC's interior surface design and the resulting cavitation result in a throughput value that was characterized by the National Institute of Standards and Technology. The ACP was installed horizontally outdoor on an aluminum plate connected to the temperature controller to control the pyrgeometer's case temperature. The responsivity of the pyrgeometer's thermopile detector was determined by lowering the case temperature and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The responsivity is then used to calculate the absolute atmospheric longwave irradiance with an uncertainty estimate (U{sub 95}) of {+-}3.96 W m{sup 02} with traceability to the International System of Units, SI. The measured irradiance was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the Interim World Infrared Standard Group, WISG. A total of 408 readings were collected over three different nights. The calculated irradiance measured by the ACP was 1.5 W/m{sup 2} lower than that measured by the two pyrgeometers that are traceable to WISG, with a standard deviation of {+-}0.7 W m{sup -2}. These results suggest that the ACP design might be used for addressing the need to improve the international reference for broadband outdoor longwave irradiance measurements.

14 SOLAR ENERGY↗

Perdew-Zunger self-interaction correction: How wrong for uniform densities and large- Z atoms?

Semilocal density functionals for the exchange-correlation energy of a many-electron system cannot be exact for all one-electron densities. In 1981, Perdew and Zunger (PZ) subtracted the fully nonlocal self-interaction error orbital-by-orbital, making the corrected functional exact for all collections of separated one-electron densities and making no correction to the exact functional. Although the PZ self-interaction correction (SIC) eliminates many errors of semilocal functionals, it is often worse for equilibrium properties of sp-bonded molecules and solids. Nonempirical semilocal functionals are usually designed to be exact for electron gases of uniform density and, thus, also make 0% error for neutral atoms in the limit of large atomic number Z, but PZ SIC is not so designed. For localized SIC orbitals, we show analytically that the local spin density approximation (LSDA)-SIC correlation energy per electron of the uniform gas in the high-density limit makes an error of -50% in the spin-unpolarized case and -100% in the fully spin-polarized case. Then we extrapolate from the Ne, Ar, Kr, and Xe atoms to estimate the relative errors of the PZ SIC exchange-correlation energies (with localized SIC orbitals) in the limit of large atomic number: about +5.5% for the LSDA-SIC and about -3.5% for nonempirical generalized gradient [Perdew-Burke-Ernzerhof (PBE)-SIC] and meta-generalized gradient strongly constrained and appropriately normed (SCAN)-SIC approximations. Finally, the SIC errors are considerably larger than those that have been estimated for LSDA-SIC by approximating the localized SIC orbitals for the uniform gas and may explain the errors of PZ SIC for equilibrium properties, opening the door to a generalized SIC that is more widely accurate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Center-of-Mass Corrections in Associated Particle Imaging

Associated particle imaging (API) utilizes the inelastic scattering of neutrons produced in deuterium-tritium (DT) fusion reactions to obtain 3-D isotopic distributions within an object. The locations of the inelastic scattering centers are calculated by measuring the arrival time and position of the associated alpha particle produced in the fusion reactions, and the arrival time of the prompt gamma created in the neutron scattering event. While the neutron and its associated particle move in opposite directions in the center-of-mass (COM) system, in the laboratory system the angle is slightly less than 180°, and the COM movement must be taken into account in the reconstruction of the scattering location. Furthermore, the fusion reactions are produced by ions of different momenta, and thus the COM velocity varies, resulting in an uncertainty in the reconstructed positions. In this article, we analyze the COM corrections to this reconstruction by simulating the energy loss of beam ions in the target material and identifying sources of uncertainty in these corrections. Here we show that an average COM velocity calculated using the ion beam direction and energy can be used in the reconstruction and discuss errors as a function of ion beam energy, composition, and alpha detection location. When accounting for the COM effect, the mean of the reconstructed locations can be considered a correctable systematic error leading to a shift/tilt in the reconstruction. However, the distribution of reconstructed locations also have a spread that will introduce an error in the reconstruction that cannot be corrected. In this article, we will use the known stopping powers of ions in materials and reaction cross sections to examine the reconstruction uncertainties. We also discuss the impact of this effect on our API system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LCLS X-ray mirror measurements using a large aperture visible light interferometer

Synchrotron or FEL X-ray mirrors are required to deliver an X-ray beam from its source to an experiment location, without contributing significantly to wave front distortion. Accurate mirror figure measurements are required prior to installation to meet this intent. This paper describes how a 300 mm aperture phasing interferometer was calibrated to <1 nm absolute accuracy and used to mount and measure 450 mm long flats for the Linear Coherent Light Source (LCLS) at Stanford Linear Accelerator Center. Measuring focus mirrors with an interferometer requires additional calibration, because high fringe density introduces systematic errors from the interferometer's imaging optics. This paper describes how these errors can be measured and corrected. The calibration approaches described here apply equally well to interferometers larger than 300 mm aperture, which are becoming more common in optics laboratories. The objective of this effort was to install LCLS flats with < 10 nm of spherical curvature, and < 2 nm rms a-sphere. The objective was met by measuring the mirrors after fabrication, coating and mounting, using a 300 mm aperture phasing interferometer calibrated to an accuracy < 1 nm. The key to calibrating the interferometer accurately was to sample the error using independent geometries that are available. The results of those measurements helped identify and reduce calibration error sources. The approach used to measure flats applies equally well to focus mirrors, provided an additional calibration is performed to measure the error introduced by fringe density. This calibration has been performed on the 300 mm aperture interferometer, and the measurement correction was evaluated for a typical focus mirror. The 300 mm aperture limitation requires stitching figure measurements together for many X-ray mirrors of interest, introducing another possible error source. Stitching is eliminated by applying the calibrations described above to larger aperture instruments. The authors are presently extending this work to a 600 mm instrument. Instruments with 900 mm aperture are now becoming available, which would accommodate the largest mirrors of interest.

43 PARTICLE ACCELERATORS↗

Error modeling for surrogates of dynamical systems using machine learning: Machine-learning-based error model for surrogates of dynamical systems

A machine learning–based framework for modeling the error introduced by surrogate models of parameterized dynamical systems is proposed. The framework entails the use of high-dimensional regression techniques (eg, random forests, and LASSO) to map a large set of inexpensively computed “error indicators” (ie, features) produced by the surrogate model at a given time instance to a prediction of the surrogate-model error in a quantity of interest (QoI). This eliminates the need for the user to hand-select a small number of informative features. The methodology requires a training set of parameter instances at which the time-dependent surrogate-model error is computed by simulating both the high-fidelity and surrogate models. Using these training data, the method first determines regression-model locality (via classification or clustering) and subsequently constructs a “local” regression model to predict the time-instantaneous error within each identified region of feature space. We consider 2 uses for the resulting error model: (1) as a correction to the surrogate-model QoI prediction at each time instance and (2) as a way to statistically model arbitrary functions of the time-dependent surrogate-model error (eg, time-integrated errors). We then apply the proposed framework to model errors in reduced-order models of nonlinear oil-water subsurface flow simulations, with time-varying well-control (bottom-hole pressure) parameters. The reduced-order models used in this work entail application of trajectory piecewise linearization in conjunction with proper orthogonal decomposition. Moreover, when the first use of the method is considered, numerical experiments demonstrate consistent improvement in accuracy in the time-instantaneous QoI prediction relative to the original surrogate model, across a large number of test cases. When the second use is considered, results show that the proposed method provides accurate statistical predictions of the time- and well-averaged errors.

97 MATHEMATICS AND COMPUTING↗

A new method for point-spread function correction using the ellipticity of re-smeared artificial images in weak gravitational lensing shear analysis

Highly accurate weak lensing analysis is urgently required for planned cosmic shear observations. For this purpose we have eliminated various systematic noises in the measurement. The point-spread function (PSF) effect is one of them. A perturbative approach for correcting the PSF effect on the observed image ellipticities has been previously employed. Here we propose a new non-perturbative approach for PSF correction that avoids the systematic error associated with the perturbative approach. The new method uses an artificial image for measuring shear which has the same ellipticity as the lensed image. This is done by re-smearing the observed galaxy images and observed star images (PSF) with an additional smearing function to obtain the original lensed galaxy images. We tested the new method with simple simulated objects that have Gaussian or Sérsic profiles smeared by a Gaussian PSF with sufficiently large size to neglect pixelization. Under the condition of no pixel noise, it is confirmed that the new method has no systematic error even if the PSF is large and has a high ellipticity.

79 ASTRONOMY AND ASTROPHYSICS↗

Single-Point Extrapolation to the Complete Basis Set Limit through Deep Learning

Machine learning (ML) offers an attractive method for making predictions about molecular systems while circumventing the need to run expensive electronic structure calculations. Once trained on ab initio data, the promise of ML is to deliver accurate predictions of molecular properties that were previously computationally infeasible. In this work, we develop and train a graph neural network model to correct the basis set incompleteness error (BSIE) between a small and large basis set at the RHF and B3LYP levels of theory. Our results show that, when compared to fitting to the total potential, an ML model fitted to correct the BSIE is better at generalizing to systems not seen during training. We test this ability by training on single molecules while evaluating on molecular complexes. We also show that ensemble models yield better behaved potentials in situations where the training data is insufficient. However, even when only fitting to the BSIE, acceptable performance is only achieved when the training data sufficiently resemble the systems one wants to make predictions on. As a result, the test error of the final model trained to predict the difference between the cc-pVDZ and cc-pV5Z potential is 0.184 kcal/mol for the B3LYP density functional, and the ensemble model accurately reproduces the large basis set interaction energy curves on the S66x8 dataset.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analyzing rotational bands in odd-mass nuclei using effective field theory and Bayesian methods

We recently developed an Effective Field Theory (EFT) for rotational bands in odd-mass nuclei. Here we use EFT expressions to perform a Bayesian analysis of data on the rotational energy levels of 99 Tc, 155,157 Gd, 159 Dy, 167,169 Er, 167,169 Tm, 183 W, 235 U and 239 Pu. The error model in our Bayesian analysis includes both experimental and EFT truncation uncertainties. It also accounts for the fact that low-energy constants (LECs) at even and odd orders are expected to have different sizes. We use Markov Chain Monte Carlo (MCMC) sampling to explore the joint posterior of the EFT and error-model parameters and show both the LECs and the breakdown scale can be reliably determined. We extract the LECs up to fourth order in the EFT and find that, provided we correctly account for EFT truncation errors in our likelihood, results for lower-order LECs are stable as we go to higher orders. LEC results are also stable with respect to the addition of higher-energy data. We extract the expansion parameter for all the nuclei listed above and find a clear correlation between the extracted and the expected value of the inverse breakdown scale, W, based on the single-particle and vibrational energy scales. However, the W that actually determines the convergence of the EFT expansion is markedly smaller than would be naively expected based on those scales.

EFT↗

COMPARING THE ENERGY SPECTRA OF ULTRAHIGH ENERGY COSMIC RAYS MEASURED WITH EXTENSIVE AIR SHOWER ARRAYS

The energy spectra of ultrahigh energy cosmic rays (CRs) measured with giant extensive air shower (EAS) arrays exhibit discrepancies between the flux intensities and/or estimated CR energies exceeding experimental errors. The well-known intensity correction factor due to the dispersion of the measured quantity in the presence of a rapidly falling energy spectrum is insufficient to explain the divergence. Another source of systematic energy determination error is proposed concerning the charged particle density measured with the surface arrays, which arises due to simplifications (namely, the superposition approximation) in nucleus-nucleus interaction description applied to the shower modeling. Making use of the essential correction factors results in congruous CR energy spectra within experimental errors. Residual differences in the energy scales of giant arrays can be attributed to the actual overall accuracy of the EAS detection technique used. CR acceleration and propagation model simulations using the dip and ankle scenarios of the transition from galactic to extragalactic CR components are in agreement with the combined energy spectrum observed with EAS arrays.

79 ASTRONOMY AND ASTROPHYSICS↗

InSAR Time Series Analysis of L-Band Wide-Swath SAR Data Acquired by ALOS-2

We present that operating at L-band (24 cm wavelength) in wide-swath modes is one of the characteristics of the new and next generation satellite synthetic aperture radar (SAR) missions. After 3 years of operation, the Japan Aerospace Exploration Agency Advanced Land Observing Satellite-2 (ALOS-2) satellite has acquired a wealth of L-band wide-swath SAR data over many areas using its ScanSAR mode. We present interferometry SAR (InSAR) time series analysis results from ALOS-2 ScanSAR data. We analyze the possible error sources in the InSAR and correct them if possible. We present different time series analysis results including azimuth frequency modulation rate error, line of sight (LOS) ionospheric phase, azimuth shift caused by the ionosphere, and LOS displacement processed using both full-aperture and burst-by -burst workflows. The final InSAR LOS displacement time series result reveals both large-scale tectonic and small-scale anthropogenic deformation components. In conclusion, the results demonstrate the potential for measuring continental or even global-scale tectonic deformation and illustrate the promise of upcoming L-band wide-swath SAR missions, such as the NASA-ISRO SAR mission.

47 OTHER INSTRUMENTATION↗

A sixth order Mehrstellen scheme with an application to the Method of Local Corrections for the 3D Poisson equation

We present a sixth order finite difference scheme for Poisson’s equation when discretized with the compact 27-point stencil based on Mehrstellen corrections of the forcing function term f. Our approach results in a sixth order accurate solution error as opposed to a fourth-order error imposed by the classical Mehrstellen correction for the 19-point and 27-point stencils. The present study is a continuation of former work of Spotz and Carey (1996) on compact finite difference schemes for Poisson’s equation where sixth order convergence may be obtained under the assumption that the fourth order derivatives of f are determined analytically. Specifically, we show that sixth order convergence can still be attained when only values of f at grid points are available. The sixth order Mehrstellen scheme is further coupled with a Method of Local Corrections (MLC) 3D Poisson solver improving to sixth order accuracy the results reported in Kavouklis and Colella (2019). The MLC test case considered involves an adaptive grid that comprises 7.5 billion cells.

97 MATHEMATICS AND COMPUTING↗

Improving Lidar Turbulence Estimates for Wind Energy

Remote sensing devices (e.g., lidars) are quickly becoming a cost-effective and reliable alternative to meteorological towers for wind energy applications. Although lidars can measure mean wind speeds accurately, these devices measure different values of turbulence intensity (TI) than an instrument on a tower. In response to these issues, a lidar TI error reduction model was recently developed for commercially available lidars. The TI error model first applies physics-based corrections to the lidar measurements, then uses machine-learning techniques to further reduce errors in lidar TI estimates. The model was tested at two sites in the Southern Plains where vertically profiling lidars were collocated with meteorological towers. This presentation primarily focuses on the physics-based corrections, which include corrections for instrument noise, volume averaging, and variance contamination. As different factors affect TI under different stability conditions, the combination of physical corrections applied in L-TERRA changes depending on the atmospheric stability during each 10-minute time period. This stability-dependent version of L-TERRA performed well at both sites, reducing TI error and bringing lidar TI estimates closer to estimates from instruments on towers. However, there is still scatter evident in the lidar TI estimates, indicating that there are physics that are not being captured in the current version of L-TERRA. Two options are discussed for modeling the remainder of the TI error physics in L-TERRA: machine learning and lidar simulations. Lidar simulations appear to be a better approach, as they can help improve understanding of atmospheric effects on TI error and do not require a large training data set.

17 WIND ENERGY↗

MEASURING X-RAY VARIABILITY IN FAINT/SPARSELY SAMPLED ACTIVE GALACTIC NUCLEI

We study the statistical properties of the normalized excess variance of variability process characterized by a ''red-noise'' power spectral density (PSD), as in the case of active galactic nuclei (AGNs). We perform Monte Carlo simulations of light curves, assuming both a continuous and a sparse sampling pattern and various signal-to-noise ratios (S/Ns). We show that the normalized excess variance is a biased estimate of the variance even in the case of continuously sampled light curves. The bias depends on the PSD slope and on the sampling pattern, but not on the S/N. We provide a simple formula to account for the bias, which yields unbiased estimates with an accuracy better than 15%. We show that the normalized excess variance estimates based on single light curves (especially for sparse sampling and S/N < 3) are highly uncertain (even if corrected for bias) and we propose instead the use of an ''ensemble estimate'', based on multiple light curves of the same object, or on the use of light curves of many objects. These estimates have symmetric distributions, known errors, and can also be corrected for biases. We use our results to estimate the ability to measure the intrinsic source variability in current data, and show that they could also be useful in the planning of the observing strategy of future surveys such as those provided by X-ray missions studying distant and/or faint AGN populations and, more in general, in the estimation of the variability amplitude of sources that will result from future surveys such as Pan-STARRS and LSST.

79 ASTRONOMY AND ASTROPHYSICS↗