Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Quantum-classical embedding via ghost Gutzwiller approximation for enhanced simulations of correlated electron systems

Simulating correlated materials on present-day quantum hardware remains challenging due to limited quantum resources. Quantum embedding methods offer a promising route by reducing computational complexity through the mapping of bulk systems onto effective impurity models, allowing more feasible simulations on pre- and early-fault-tolerant quantum devices. Here, this work develops a quantum-classical embedding framework based on the ghost Gutzwiller approximation to enable quantum-enhanced simulations of ground-state properties and spectral functions of correlated electron systems. Circuit complexity is analyzed using an adaptive variational quantum algorithm on a statevector simulator, applied to the infinite-dimensional Hubbard model with increasing ghost mode numbers from 3 to 5, resulting in circuit depths growing from 16 to 104. Noise effects are examined using a realistic error model, revealing significant impact on the spectral weight of the Hubbard bands. To mitigate these effects, the Iceberg quantum error detection code is employed, achieving up to 40% error reduction in simulations. Finally, the accuracy of the density matrix estimation and the derived spectral function is benchmarked on IBM and Quantinuum quantum hardware, featuring distinct qubit-connectivity and employing multiple levels of error mitigation techniques.

Chen, I-Chi [Ames Laboratory (AMES), Ames, IA (Uni↗

A Monte Carlo technique to model performance of streak camera-based time-resolving x-ray spectrometers

A Monte Carlo technique has been developed to simulate the expected signal and the statistical noise of x-ray spectrometers that use streak cameras to achieve the time resolution required for ultrafast diagnostics of laser-generated plasmas. The technique accounts for statistics from both the photons incident on the streak camera’s photocathode and the electrons emitted by the photocathode travelling through the camera’s electron optics to the sensor. We use the technique to optimize the design of a spectrometer, which deduces the temporal history of electron temperature of the hotspot in an inertial confinement fusion implosion from its hard x-ray continuum emission spectra. The technique is general enough to be applied to any instrument using an x-ray streak camera.

Stoupin, S. (ORCID:0000000226225270)↗

Toward streaked collective Thomson scattering measurements on an extreme ultraviolet plasma light source

Here we show through forward modeling calculations that streaked collective Thomson scattering measurements are feasible on laser-produced tin plasmas generated under conditions relevant for extreme ultraviolet lithography. Using a 532 nm probe laser beam, the feasibility of simultaneous measurements of electron plasma wave (EPW) and ion acoustic wave (IAW) spectra is investigated. Absolute photon counts for laser scattering off both waves are calculated. Probe laser electron heating and bremsstrahlung background radiation effects are accounted for. While a large spatiotemporal region can be successfully probed based on the IAW feature, only one measurement location can be accessed through the EPW as a result of the low signal to noise ratio. A portable/traveling tabletop system is proposed.

47 OTHER INSTRUMENTATION↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Description of reaction and vibrational energetics of CO 2 –NH 3 interaction using quantum computing algorithms

CO 2 capture is critical to solving global warming. Amine-based solvents are extensively used to chemically absorb CO 2 . Thus, it is crucial to study the chemical absorption of CO 2 by amine-based solvents to better understand and optimize CO 2 capture processes. Here, we use quantum computing algorithms to quantify molecular vibrational energies and reaction pathways between CO 2 and a simplified amine-based solvent model—NH 3 . Molecular vibrational properties are important to understanding kinetics of reactions. However, the molecule size correlates with the strength of anharmonicity effect on vibrational properties, which can be challenging to address using classical computing. Quantum computing can help enhance molecular vibrational calculations by including anharmonicity. We implement a variational quantum eigensolver (VQE) algorithm in a quantum simulator to calculate ground state vibrational energies of reactants and products of the CO 2 and NH 3 reaction. The VQE calculations yield ground vibrational energies of CO 2 and NH 3 with similar accuracy to classical computing. In the presence of hardware noise, Compact Heuristic for Chemistry (CHC) ansatz with shallower circuit depth performs better than Unitary Vibrational Coupled Cluster. The “Zero Noise Extrapolation” error-mitigation approach in combination with CHC ansatz improves the vibrational calculation accuracy. Excited vibrational states are accessed with quantum equation of motion method for CO 2 and NH 3 . Using quantum Hartree–Fock (HF) embedding algorithm to calculate electronic energies, the corresponding reaction profile compares favorably with Coupled Cluster Singles and Doubles while being more accurate than HF. Our research showcases quantum computing applications in the study of CO 2 capture reactions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Movable Thermometer System in ProtoDUNE

The movable temperature profiler is a 7 m vertical array of 24 sensors that measures cryogenic temperatures with a precision of a few mK. This precision is necessary to monitor the efficiency of re-circulation and purification of liquid-argon inside large liquid-argon based neutrino detectors. Liquid argon temperature impacts electron (signal) drift velocity, flow, purity distribution and thus the overall energy calibration. The temperature profiler is motorized and moves vertically, while in the detector, and cross-calibrates neighboring sensors. The temperature offsets between each sensor cancel the effects of electromagnetic noise. This poster reports on the temperature measurements and such in-situ cross-calibrations at ProtoDUNE (single phase) at CERN.}

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quiet Clean Short-haul Experimental Engine (QCSEE) under-the-wing engine digital control system design report

A digital electronic control was combined with conventional hydromechanical components to operate the four controlled variables on the under-the-wing engine: fuel flow, fan blade pitch, fan exhaust area, and core compressor stator angles. The engine and control combination offers improvements in noise, pollution, thrust response, operational monitoring, and pilot workload relative to current engines.

Source record↗

Setting up a Rayleigh Scattering Based Flow Measuring System in a Large Nozzle Testing Facility

A molecular Rayleigh scattering based air density measurement system has been built in a large nozzle testing facility at NASA Glenn Research Center. The technique depends on the light scattering by gas molecules present in air; no artificial seeding is required. Light from a single mode, continuous wave laser was transmitted to the nozzle facility by optical fiber, and light scattered by gas molecules, at various points along the laser beam, is collected and measured by photon-counting electronics. By placing the laser beam and collection optics on synchronized traversing units, the point measurement technique is made effective for surveying density variation over a cross-section of the nozzle plume. Various difficulties associated with dust particles, stray light, high noise level and vibration are discussed. Finally, a limited amount of data from an underexpanded jet are presented and compared with expected variations to validate the technique.

Panda, Jayanta↗

Improved equivalent circuit for twin slot terahertz receivers

Series-fed coplanar waveguide embedding circuits are being developed for terahertz mixers using, in particular, submicron-sized superconducting devices, such as hot electron bolometers as the nonlinear element. Although these mixers show promising performance, they usually also show a considerable downward shift in the center frequency, when compared with simulations obtained by using simplified models. This makes it very difficult to design low-noise mixers for a given THz frequency. This shiftis principally caused by parasitics due to the extremely small details (in terms of wavelength) of the device, and by the electrical properties of the RF choke filter in the DC/IF line. In this paper, we present an improved equivalent network model of such mixer circuits which agrees with measured results at THz frequencies and we propose a new set of THz bolometric mixers that have been fabricated and are currently being tested.

HEB slot antennas CPW↗

Precision Continuum Receivers for Astrophysical Applications

Cryogenically cooled HEMT (High Electron Mobility Transistor) amplifiers find widespread use in radioastronomy receivers. In recent years, these devices have also been commonly employed in broadband receivers for precision measurements of the Cosmic Microwave Background (CMB) radiation. In this setting, the combination of ultra-low-noise and low-spectral-resolution observations reinforce the importance achieving suitable control over the device environment to achieve fundamentally limited receiver performance. The influence of the intrinsic amplifier stability at low frequencies on data quality (e.g., achievable noise and residual temporal correlations), observational and calibration strategies, as well as architectural mitigation approaches in this setting will be discussed. The implications of device level 1/f fluctuations reported in the literature on system performance will be reviewed.

Wollack, Edward J.↗

The chemRIXS Instrument for Solution-Phase Resonant Inelastic X-ray Scattering at the Linac Coherent Light Source

The chemRIXS instrument at the Linac Coherent Light Source (LCLS) offers new opportunities for studying solution-phase systems with time-resolved soft X-ray spectroscopic methods such as resonant inelastic X-ray scattering (RIXS) using the recently commissioned high-repetition-rate LCLS-II X-ray free electron laser. The orders-of-magnitude X-ray flux improvement provided by the superconducting accelerator, combined with corresponding advances in the optical laser system and the liquid jet recirculation system, enables studies on dilute systems with high signal-to-noise compared to what was possible with the LCLS-I copper accelerator. These capabilities open up time-resolved X-ray absorption spectroscopy and RIXS to entirely new classes of samples, as well as enabling the development of new soft X-ray spectroscopic methods on liquid samples. An overview of the beamline components and the first LCLS-II commissioning results are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shot noise and differential conductance as signatures of putative topological superconductivity in FeSe 0.45 ⁢Te 0.55

We present a theory for the differential shot noise, dS/dV, as measured via shot-noise scanning tunneling spectroscopy, and the differential conductance, dI/dV, for tunneling into Majorana zero modes (MZMs) in the putative topological superconductor FeSe 0.45 Te 0.55 . We demonstrate that for tunneling into chiral Majorana edge modes near domain walls, as well as MZMs localized in vortex cores and at the end of defect lines, dS/dV vanishes whenever dI/dV reaches a quantized value proportional to the quantum of conductance. Furthermore, these results are independent of the particular orbital tunneling path, thus establishing a vanishing dS/dV concomitant with a quantized dI/dV, as universal signatures for Majorana modes in two-dimensional topological superconductors, irrespective of the material’s specific complex electronic band structure.

Iron-based superconductors↗

Digital Architecture for a Trace Gas Sensor Platform

A digital architecture has been implemented for a trace gas sensor platform, as a companion to standard analog control electronics, which accommodates optical absorption whose fractional absorbance equivalent would result in excess error if assumed to be linear. In cases where the absorption (1-transmission) is not equivalent to the fractional absorbance within a few percent error, it is necessary to accommodate the actual measured absorption while reporting the measured concentration of a target analyte with reasonable accuracy. This requires incorporation of programmable intelligence into the sensor platform so that flexible interpretation of the acquired data may be accomplished. Several different digital component architectures were tested and implemented. Commercial off-the-shelf digital electronics including data acquisition cards (DAQs), complex programmable logic devices (CPLDs), field-programmable gate arrays (FPGAs), and microcontrollers have been used to achieve the desired outcome. The most completely integrated architecture achieved during the project used the CPLD along with a microcontroller. The CPLD provides the initial digital demodulation of the raw sensor signal, and then communicates over a parallel communications interface with a microcontroller. The microcontroller analyzes the digital signal from the CPLD, and applies a non-linear correction obtained through extensive data analysis at the various relevant EVA operating pressures. The microcontroller then presents the quantitatively accurate carbon dioxide partial pressure regardless of optical density. This technique could extend the linear dynamic range of typical absorption spectrometers, particularly those whose low end noise equivalent absorbance is below one-part-in-100,000. In the EVA application, it allows introduction of a path-length-enhancing architecture whose optical interference effects are well understood and quantified without sacrificing the dynamic range that allows quantitative detection at the higher carbon dioxide partial pressures. The digital components are compact and allow reasonably complete integration with separately developed analog control electronics without sacrificing size, mass, or power draw.

Gonzales, Paula↗

Electron-ion collider transverse instabilities due to the crab cavity fundamental impedance

The electron-ion collider crab Cavities will present a significant transverse impedance to the beam. The low-level radio frequency system will have to reduce the crab cavity impedance to prevent transverse instabilities, while regulating the crabbing voltage and minimizing the radio frequency noise levels injected into the beam. This work presents an estimate of the crab cavity impedance in the presence of feedback and the resulting stability margins using simplified stability criteria. Generalized stability criteria are also presented in this work and are used to more accurately estimate stability margins.

43 PARTICLE ACCELERATORS↗

Notes on Tapered Active Array Antenna Performance

Modern Active Electronically Steerable Array (AESA) antennas offer substantial control over transmit and receive antenna beam forming, including via elemental weighting to achieve a desired tapered aperture. However, these tapers also have the adverse side effect of diminishing total transmitted power and/or raising the system noise figure. This is readily calculated, and must be considered for overall radar performance prediction. Independent tapers for transmit and receive arrays might be play.

42 ENGINEERING↗

Rebalance electronics

Two basic types of strapdown gyroscope rebalance-electronics were analyzed and compared. These two types were a discrete-pulse ternary system and a width-modulated binary system. In the analyses, major emphasis was placed on the logic sections, the H-switches, the precision voltage reference loops, the noise performance, common-mode rejection, and loop compensation. Results of the analyses were used in identifying specific advantages and disadvantages of system details and in making accuracy and resolution comparisons. Sound engineering principles were applied in the development of both systems; however, it was concluded that each system has some disadvantages that are amenable to improvement.

Blalock, T. V.↗

The determination of atmospheric trace gases using the correlation interferometer technique

The theoretical feasibility inherent in the correlation interferometry technique is demonstrated. High signal to noise and increased information content in a given partial interferogram are attractive features of the technique. The separation of interfering gas species is overcome by a precise measurement program for spectral line parameters of methane and other species. There are optical, mechanical, and electronic difficulties with the interferometry hardware design. Flight data from Cessna 402 over southeastern Virginia during April 1978 yielded amplitude fluctuations that are explainable only as internal nonlinearities. Misalignment of the AGC/interferometer optical axis also contributed to a large error source in the flight data. It is concluded that no useful data on gas burdens was obtained from these flights.

Kindle, E. C.↗

Thermal detectors for high resolution spectroscopy

Cryogenic microcalorimeters can be made sensitive enough to measure the energy deposited by a single particle or X-ray photon with an accuracy of about one electron volt. It may also be possible to construct detectors of several-kilograms mass whose resolution is only a few times worse than this. Data from relatively crude test devices are in good agreement with thermal performance calculations, and a total system noise of 11 eV FWHM has been obtained for a silicon detector operating at 98 mK. Observations of 35 eV FWHM for 6-keV X-rays with a different device have been made.

Mccammon, D.↗