Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Searching for Sterile Neutrinos In the NOvA Experiment and Measurements of Hadronic Energy Response with NOvA Test Beam Data

The NOvA (NuMI Off-Axis electron neutrino Appearance) experiment is a long-baseline neutrino oscillation experiment composed of two functionally identical detectors: a 300-ton Near Detector and a 14-kton Far Detector, separated by 809 km and placed 14 mrad off the axis of the NuMI neutrino beam created at Fermilab. This configuration enables NOvA’s rich neutrino physics program, which includes measuring neutrino mixing parameters, determining the neutrino mass hierarchy, probing CP violation in the leptonic sector, studying neutrino cross sections, searching for sterile neutrinos, and more.\\ In this thesis I will present two independent analyses developed within the NOvA experiment. The first is a search for light sterile neutrino oscillations in the 3+1 framework using $\nu_\mu$-CC and NC samples from the NOvA Near and Far Detectors. Light sterile neutrinos are hypothetical neutral leptons that do not participate in the weak interactions but can mix with the three known active neutrinos: $\nu_e$, $\nu_\mu$, and $\nu_\tau$. Anomalous results, such as $\nu_e$/$\bar{\nu}e$ appearance in a $\nu_\mu$ ($\bar{\nu}_\mu$) beam observed by the MiniBooNE and LSND experiments, can be explained by the existence of sterile neutrinos. Thus, proving the existence of this type of neutrino is essential. The latest results of these searches in the NOvA experiment, along with contributions to this effort, will be presented.\\ The second is the first measurement of the pion energy response using data from the NOvA Test Beam experiment. The NOvA Test Beam experiment, deployed at Fermilab, uses a scaled-down 30-ton NOvA detector to analyze tagged beamline particles. The beamline can select and identify electrons, muons, pions, kaons, and protons with momenta ranging from 0.4 to 1.4 GeV/c. Pions are an important component of the hadronic system in neutrino interactions, and understanding how the detector responds to these particles is crucial for the validation of the simulation and the reduction of detector calibration uncertainties, which remain one of the largest systematic uncertainties in NOvA analyses.

Dueñas Tonguino, David Francisco [Cincinnati U.] (↗

Measurements of selected psi /3684/ branching ratios from a study of secondary lepton pairs

The measurements considered were made at the electron-positron storage ring at the Stanford Linear Accelerator Center. The apparatus used consists of two identical spectrometers mounted in a collinear configuration about the beam-interaction region. The energies of secondary electrons or positrons are measured with good resolution in large NaI(Tl) total-absorption detectors. Data accumulated without gamma-ray converters were examined for electron-positron pairs. The data taken with gamma-ray converters in place and at center-of-mass energies within 1 MeV of the resonance energy were scanned for evidence of either charged particles or converted gamma rays accompanying the detected muon pairs.

Hilger, E.↗

Development of a unit cell for a Ge:Ga detector array

Two modules of gallium-doped germanium (Ge:Ga) infrared detectors with integrated multiplexing readouts and supporting drive electronics were designed and tested. This development investigated the feasibility of producing two-dimensional Ge:Ga arrays by stacking linear modules in a housing capable of providing uniaxial stress for enhanced long-wavelength response. Each module includes 8 detectors (1x1x2 mm) mounted to a sapphire board. The element spacing is 12 microns. The back faces of the detector elements are beveled with an 18 deg angle, which was proved to significantly enhance optical absorption. Each module includes a different silicon metal-oxide semiconductor field effect transistor (MOSFET) readout. The first circuit was built from discrete MOSFET components; the second incorporated devices taken from low-temperature integrated circuit multiplexers. The latter circuit exhibited much lower stray capacitance and improved stability. Using these switched-FET circuits, it was demonstrated that burst readout, with multiplexer active only during the readout period, could successfully be implemented at approximately 3.5 K.

Source record↗

Search for resonant $WZ$ production in the fully leptonic final state in proton–proton collisions at $\sqrt{s}$= 13 TeV with the ATLAS detector

A search for a $WZ$ resonance, in the fully leptonic final state (electrons or muons), is performed using 139 fb –1 of data collected at a centre-of-mass energy of 13 TeV by the ATLAS detector at the Large Hadron Collider. The results are interpreted in terms of a singly charged Higgs boson of the Georgi–Machacek model, produced by WZ fusion, and of a Heavy Vector Triplet, with the resonance produced by $WZ$ fusion or the Drell–Yan process. No significant excess over the Standard Model prediction is observed and limits are set on the production cross-section times branching ratio as a function of the resonance mass for these processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transferring orbital angular momentum to an electron beam reveals toroidal and chiral order

Orbital angular momentum (OAM) and torque transfer play central roles in a wide range of magnetic textures and devices including skyrmions and spin-torque electronics. Analogous topological structures are now also being explored in ferroelectrics, including polarization vortex arrays in ferroelectric/dielectric superlattices. Unlike magnetic toroidal order, electric toroidal order does not couple directly to linear external fields. Instead, we find that the presence of an electric toroidal moment in a ferrorotational phase transfers measurable torque and OAM to a localized electron beam in the ballistic limit. We record these torque transfers from a high-energy electron beam using a momentum-resolved detector. This approach provides a high-sensitivity method to detect polarization fields and their more complex order parameters and topologies. In addition to toroidal order, we also demonstrate high-precision measurements of vorticity and chirality for polar vortexlike phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Above-threshold ionization at laser intensity greater than 10 20 W / cm 2

Here we present experimental observation of above-threshold ionization (ATI) electrons produced by ionization of the neon K shell in a laser field where intensity exceeds 10 20 W/cm 2 . An array of plastic scintillating calorimeter detectors was used to measure the high-energy electrons at four angles in the laser forward direction. Coarse energy resolution was obtained using aluminum filters of several thicknesses to block lower-energy electrons. A threshold intensity around 2×10 20 W/cm 2 is observed for production of energetic ATI electrons in the laser forward direction, with maximum electron energy exceeding 10 MeV. L-shell electrons with energies <1.4 MeV are scattered farther forward along the laser direction than expected. We present comparisons of the measured total electron energies to the predictions of Monte Carlo models employing the ADK-PPT ionization model and the Augst barrier suppression ionization model.

74 ATOMIC AND MOLECULAR PHYSICS↗

Conducting Beyond the Standard Model Searches in the MicroBooNE Detector with Machine Learning

MicroBooNE is one of the three neutrino detectors that comprise the Short Baseline Neutrino program at Fermilab. It utilizes Liquid Argon Time Projection Chamber (LArTPC) technology to probe the anomalous excess of electron-like events seen by its predecessor, MiniBooNE. Additionally, it provides a rich avenue of study for Beyond the Standard Model (BSM) theories. In the GeV energy regime relevant to MicroBooNE's beam neutrino program, many such theories lead to signatures which produce electron-positron (e+e-) final-states in the detector. While photons can pair produce into e+e- pairs with negligible opening angles, BSM theories often predict e+e- pairs with a broader range of opening angles. Thus, developing a tool that can reliably measure the opening angles of e+e- events is crucial for conducting rigorous BSM studies. However, these e+e- pairs result in topologically complex showers instead of clean tracks, making non-machine learning (ML) based methods such as line-fitting unsuitable for this task. This poster discusses the effectiveness of ML, namely a graph neural network called PointNet++, in accomplishing this goal. Our studies show promising results, with a resolution for the opening angle of 5 or less.

Bhelande, Vedang Adutya [Los Alamos]↗

Quantitative Electron Probe Microanalysis: State of the Art

Quantitative electron-probe microanalysis (EPMA) has improved due to better instrument design and X-ray correction methods. Design improvement of the electron column and X-ray spectrometer has resulted in measurement precision that exceeds analytical accuracy. Wavelength-dispersive spectrometer (WDS) have layered-dispersive diffraction crystals with improved light-element sensitivity. Newer energy-dispersive spectrometers (EDS) have Si-drift detector elements, thin window designs, and digital processing electronics with X-ray throughput approaching that of WDS Systems. Using these systems, digital X-ray mapping coupled with spectrum imaging is a powerful compositional mapping tool. Improvements in analytical accuracy are due to better X-ray correction algorithms, mass absorption coefficient data sets,and analysis method for complex geometries. ZAF algorithms have ban superceded by Phi(pz) algorithms that better model the depth distribution of primary X-ray production. Complex thin film and particle geometries are treated using Phi(pz) algorithms, end results agree well with Monte Carlo simulations. For geological materials, X-ray absorption dominates the corretions end depends on the accuracy of mass absorption coefficient (MAC) data sets. However, few MACs have been experimentally measured, and the use of fitted coefficients continues due to general success of the analytical technique. A polynomial formulation of the Bence-Albec alpha-factor technique, calibrated using Phi(pz) algorithms, is used to critically evaluate accuracy issues and can be also be used for high 2% relative and is limited by measurement precision for ideal cases, but for many elements the analytical accuracy is unproven. The EPMA technique has improved to the point where it is frequently used instead of the petrogaphic microscope for reconnaissance work. Examples of stagnant research areas are: WDS detector design characterization of calibration standards, and the need for more complete treatment of the continuum X-ray fluorescence correction.

Carpernter, P. K.↗

Performance of the LHCb muon detector in Run 3

In Run 3 of the LHC, the instantaneous luminosity at the LHCb interaction point has been increased by a factor of five, from to $\mathscr{L}$ = 4 x 10 32 cm -2 s -2 to $\mathscr{L}$ = 2 x 10 33 cm -2 s -1 . Several hardware interventions, including a complete overhaul of the readout electronics, have been carried out on the muon detector. The muon identification algorithms in the software trigger were improved with the aim of ensuring Run 2 performance under a higher particle rate. The operation and calibration of the upgraded muon detector are presented. The muon detection efficiency and muon identification performance are evaluated on data calibration samples collected during the year 2024. A muon identification efficiency above 90% with sub-percent hadron misidentification probability is achieved by exploiting the pattern of hits in the muon detector.

Gaseous detectors↗

High rate studies of the ATLAS sTGC detector and optimization of the filter circuit on the input of the front-end amplifier

Abstract The Large Hadron Collider (LHC) at CERN is expected to be upgraded to the High-Luminosity LHC (HL-LHC) by 2029 and achieve instantaneous luminosity around 5–7.5 × 10 34 cm -2 s -1 . This represents a more than 3–4 fold increase in the instantaneous luminosity compared to what has been achieved in Run 2. The New Small Wheel (NSW) upgrade is designed to be able to operate efficiently in this high background rate environment. In this article, we summarize multiple performance studies of the small-strip Thin Gap Chamber (sTGC) at high rate using nearly final front-end electronics. We demonstrate that the efficiency versus rate distribution can be well described by an exponential decay with electronics dead-time being the primary cause of loss of efficiency at high rate. We then demonstrate several methods that can decrease the electronics dead-time and therefore minimize efficiency loss. One such method is to install either a pi-network input filter or pull-up resistor to minimize the charge input into the amplifier. We optimized the pi-network capacitance and pull-up resistor resistance using the results from our measurements. The results shown here were not only critical to finalizing the components on the front-end board, but also are critical for setting the optimal operating parameters of the sTGC detector and electronics in the ATLAS cavern.

Instruments & Instrumentation↗

Blocking Losses With a Photon Counter

It was not known how to assess accurately losses in a communications link due to photodetector blocking, a phenomenon wherein a detector is rendered inactive for a short time after the detection of a photon. When used to detect a communications signal, blocking leads to losses relative to an ideal detector, which may be measured as a reduction in the communications rate for a given received signal power, or an increase in the signal power required to support the same communications rate. This work involved characterizing blocking losses for single detectors and arrays of detectors. Blocking may be mitigated by spreading the signal intensity over an array of detectors, reducing the count rate on any one detector. A simple approximation was made to the blocking loss as a function of the probability that a detector is unblocked at a given time, essentially treating the blocking probability as a scaling of the detection efficiency. An exact statistical characterization was derived for a single detector, and an approximation for multiple detectors. This allowed derivation of several accurate approximations to the loss. Methods were also derived to account for a rise time in recovery, and non-uniform illumination due to diffraction and atmospheric distortion of the phase front. It was assumed that the communications signal is intensity modulated and received by an array of photon-counting photodetectors. For the purpose of this analysis, it was assumed that the detectors are ideal, in that they produce a signal that allows one to reproduce the arrival times of electrons, produced either as photoelectrons or from dark noise, exactly. For single detectors, the performance of the maximum-likelihood (ML) receiver in blocking is illustrated, as well as a maximum-count (MC) receiver, that, when receiving a pulse-position-modulated (PPM) signal, selects the symbol corresponding to the slot with the largest electron count. Whereas the MC receiver saturates at high count rates, the ML receiver may not. The loss in capacity, symbol-error-rate (SER), and count-rate were numerically computed. It was shown that the capacity and symbol-error-rate losses track, whereas the count-rate loss does not generally reflect the SER or capacity loss, as the slot-statistics at the detector output are no longer Poisson. It is also shown that the MC receiver loss may be accurately predicted for dead times on the order of a slot.

Moision, Burce E.↗

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a p + -doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10–100. This technology can provide time resolution on the order of 20–30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a ^90Sr source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. Here, the experimental results are also compared to TCAD simulations.

47 OTHER INSTRUMENTATION↗

Measurement of the Z boson invisible width at $\sqrt{s}=13$ TeV with the ATLAS detector

A measurement of the invisible width of the Z boson using events with jets and missing transverse momentum is presented using 37 fb -1 of 13 TeV proton–proton data collected by the ATLAS detector in 2015 and 2016. The ratio of Z → inv to Z → ℓℓ events, where inv refers to non-detected particles and ℓ is either an electron or a muon, is measured and corrected for detector effects. Events with at least one energetic central jet with p T ≥ 110 GeV are selected for both the Z → inv and Z → ℓℓ final states to obtain a similar phase space in the ratio. The invisible width is measured to be 506 ± 2 (stat.) ± 12 (syst.) MeV and is the single most precise recoil-based measurement. The result is in agreement with the most precise determination from LEP and the Standard Model prediction based on three neutrino generations.

13000 GeV-cms↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

Improved modeling of detector response effects in phonon-based crystal detectors used for dark matter searches

Various dark matter search experiments employ phonon-based crystal detectors operated at cryogenic temperatures. Some of these detectors, including certain silicon detectors used by the SuperCDMS Collaboration, are able to achieve single-charge sensitivity when a voltage bias is applied across the detector. The total amount of phonon energy measured by such a detector is proportional to the number of electron-hole pairs created by the interaction. However, crystal impurities and surface effects can cause propagating charges to either become trapped inside the crystal or create additional unpaired charges, producing non-quantized measured energy as a result. A new analytical model for describing these detector response effects in phonon-based crystal detectors is presented. This model improves upon previous versions by demonstrating how the detector response, and thus the measured energy spectrum, is expected to differ depending on the source of events. Finally, we use this model to extract detector response parameters for SuperCDMS HVeV detectors, and illustrate how this robust modelling can help statistically discriminate between sources of events in order to improve the sensitivity of dark matter search experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and performance of a modularized NaI/Tl/ detector /The Crystal Ball prototype/

A prototype NaI(Tl) detector (the Cluster of 54) of spherical geometry subtending a solid angle of 7.5% of 4pi at its center, has recently been assembled and tested. This detector consists of 54 close-packed but optically isolated NaI(Tl) modules and the associated electronic circuitry. The Cluster of 54 is the predecessor of an almost complete spherical detector, the Crystal Ball, which will cover 94% of 4pi. The latter detector is now under construction and is especially designed for the study of gamma-rays produced in electron-positron collisions at colliding beam facilities. This article outlines the mechanical, optical, and electronic assembly of the prototype system.

Chan, Y.↗

Test of light-lepton universality in τ decays with the Belle II experiment

We present a measurement of the ratio R µ = $\mathcal{B}$($τ^- → µ^-\overline{ν}_µν_τ$)/$\mathcal{B}(τ^- → e^-\overline{ν}_eν_τ$) of branching fractions B of the τ lepton decaying to muons or electrons using data collected with the Belle II detector at the SuperKEKB e + e - collider. The sample has an integrated luminosity of 362 ± 2 fb -1 at a centre-of-mass energy of 10.58 GeV. Using an optimised event selection, a binned maximum likelihood ft is performed using the momentum spectra of the electron and muon candidates. The result, R µ = 0.9675 ± 0.0007 ± 0.0036, where the first uncertainty is statistical and the second is systematic, is the most precise to date. It provides a stringent test of the light-lepton universality, translating to a ratio of the couplings of the muon and electron to the W boson in τ decays of 0.9974 ± 0.0019, in agreement with the standard model expectation of unity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Effect Of Ionization Variance On Nuclear-recoil Dark Matter Searches

Direct detection dark matter experiments are increasingly interested in the low-mass dark matter parameter space, but zero-background low-mass searches require event separation between the electron and nuclear recoil bands, which requires a proper understanding of detector energy reconstruction. Previous simulations have shown that we do not entirely understand the ionization efficiency (yield) for electron and nuclear recoils, as the assumption that the distribution for the yield is normally distributed for a true recoil energy is violated. Since the yield distribution may directly affect dark matter low-mass limits, it is crucial we understand how the yield is distributed. A component to understanding the yield distribution is the variance in the number of electron-hole pairs produced or ionization variance. This effect has been studied relatively infrequently as experiments have been interested in large energy deposits (10 - 100 keV) and could accurately separate electron and nuclear recoil events. For electron recoils, the ionization variance is described by a “Fano” factor. For nuclear recoils the effect can be parameterized by an “effective” Fano factor, which has similar definition but a different physical origin. The nuclear recoil “effective” Fano factor is shown to be much larger than the electron-recoil version above around 10 keV deposited energy.

Matheny, Mitchell Douglas↗