Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diode effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Optical Properties of Copper-Doped Lithium Niobate Crystals

We have studied the optical properties of copper-doped lithium niobate crystals using semiconductor light-emitting diodes and lasers emitting in the visible and ultraviolet spectral regions as excitation sources. The results demonstrate that, at an excitation frequency approaching the frequency of electronic absorption in copper ions, there is discrete resonance Raman scattering in the form of a frequency comb. The observed Raman satellites of discrete light scattering are due to polar longitudinal A{sub 1} optical modes of the lithium niobate single crystal. Under excitation by a light-emitting diode with a wavelength of 520 nm, we observe a sharp increase in discrete light scattering intensity in comparison with the photoluminescence excited by shorter wavelength excitation sources.

36 MATERIALS SCIENCE↗

Hopping transport in the space-charge region of p-n structures with InGaN/GaN QWs as a source of excess 1/f noise and efficiency droop in LEDs

It is shown that the emission efficiency and the 1/f noise level in light-emitting diodes with InGaN/GaN quantum wells correlate with how the differential resistance of a diode varies with increasing current. Analysis of the results shows that hopping transport via defect states across the n-type part of the space-charge region results in limitation of the current by the tunneling resistance at intermediate currents and shunting of the n-type barrier at high currents. The increase in the average number of tunneling electrons suppresses the 1/f current noise at intermediate currents. The strong growth in the density of current noise at high currents, S{sub J} ∝ J{sup 3}, is attributed to a decrease in the average number of tunneling electrons as the n-type barrier decreases in height and width with increasing forward bias. The tunneling-recombination leakage current along extended defects grows faster than the tunneling injection current, which leads to emission efficiency droop.

36 MATERIALS SCIENCE↗

A mass spectrometric system for analyzing thermal desorption spectra of ion-implanted argon and cesium in tungsten

A mass spectrometric system for determining the characteristics of materials used in instrumental development and aerospace applications was developed. The desorption spectra of cesium that was ion-implanted into polycrystalline tungsten and the effects on the spectra of bombardment of the tungsten by low energy (70 eV) electrons were investigated. Work function changes were measured by the retarding potential diode method. Flash desorption characteristics were observed and gas-reaction mechanisms of the surface of heated metal filaments were studied. Desorption spectra were measured by linearly increasing the sample temperature at a selected rate, the temperature cycling being generated from a ramp-driven dc power supply, with the mass spectrometer tuned to a mass number of interest. Results of the study indicate an anomolous desorption mechanism following an electron bombardment of the sample surface. The enhanced spectra are a function of the post-bombardment time and energy and are suggestive of an increased concentration of cesium atoms, up to 10 or more angstroms below the surface.

Wood, G. M., Jr.↗

Saturated absorption in NH3 demonstrated using a tuneable diode laser

Saturation of molecular transitions using a tunable diode laser has been demonstrated for the first time using a standing-wave-cavity configuration with the laser beam focused at the sample. Observed saturation effects in NH3 transitions near 888 kaysers include sub-Doppler (Lamb-dip) resonances at the line center.

Jennings, D. E.↗

62-dB-gain multiple-pass slab geometry Nd:YAG amplifier

A flash-lamp-pumped slab Nd:YAG laser amplifier with 62 dB of gain is demonstrated. The amplifier remains linear for energy extraction up to 12 mJ, and the beam spatial quality remains good at repetition rates up to 10 Hz. The slab geometry provides for gain averaging in the zigzag dimension, thus eliminating the undesirable effects of nonuniform pumping. This averaging and the necessity for only a single compact gain element are valuable attributes that may allow for eventual laser-diode array pumping of the slab Nd:YAG amplifier.

Kane, T. J.↗

Analysis of Carbon Nanotube Metal-Semiconductor Diode Device

We study recently reported drain current I(sub d)-drain voltage V(sub d) characteristics of a carbon nanotube metal-semiconductor diode device with the gate voltage V(sub g) applied to modulate the carrier density in the nanotube. The diode was kink-shaped at the metal-semiconductor interface. It was shown that (1) larger negative V(sub g) blocked I(sub d) more effectively in the negative V(sub d) region, resulting in the rectifying I(sub d)-V(sub d) characteristics, and that (2) positive V(sub g) allowed I(sub d) in the both V(sub d) polarities, resulting in the non-rectifying characteristics. The negative V(sub d) was the Schottky reverse direction, judging from the negligible I(sub d) behavior for a wide region of -4 V (is less than) V(sub d) (is less than) 0 V, with V(sub g) = -4 V. Such negative V(sub g) would attract positive charges from the metallic electrodes (charge reservoir) to the nanotube and lower the nanotube Fermi energy (E(sub F)). With larger negative V(sub g), the experiment showed that the Schottky forward direction (V(sub d) (is greater than) 0) had a smaller turn-on voltage and the Schottky reverse direction (V(sub d) (is less than) 0) was more resistant to the tunneling breakdown. Therefore, the majority carriers in the transport would be electrons since they can see a lower tunneling barrier (shallower built-in potential) in the forward direction when E(sub F) is lowered, and a thicker tunneling barrier (Schottky barrier) in the reverse direction due to the reduction in the electron density when E(sub F) is lowered.

Yamada, Toshishige↗

Portable Unit for Metabolic Analysis

The Portable Unit for Metabolic Analysis (PUMA) is an instrument that measures several quantities indicative of human metabolic function. Specifically, this instrument makes time-resolved measurements of temperature, pressure, flow, and the partial pressures of oxygen and carbon dioxide in breath during both inhalation and exhalation. Portable instruments for measuring these quantities have been commercially available, but the response times of those instruments are too long to enable temporal resolution of phenomena on the time scales of human respiration cycles. In contrast, the response time of the PUMA is significantly shorter than characteristic times of human respiration phenomena, making it possible to analyze varying metabolic parameters, not only on sequential breath cycles but also at successive phases of inhalation and exhalation within the same breath cycle. In operation, the PUMA is positioned to sample breath near the subject s mouth. Commercial off-the-shelf sensors are used for three of the measurements: a miniature pressure transducer for pressure, a thermistor for temperature, and an ultrasonic sensor for flow. Sensors developed at Glenn Research Center are used for measuring the partial pressures of oxygen and carbon dioxide: The carbon dioxide sensor exploits the relatively strong absorption of infrared light by carbon dioxide. Light from an infrared source passes through the stream of inhaled or exhaled gas and is focused on an infrared- sensitive photodetector. The oxygen sensor exploits the effect of oxygen in quenching the fluorescence of ruthenium-doped organic molecules in a dye on the tip of an optical fiber. A blue laser diode is used to excite the fluorescence, and the optical fiber carries the fluorescent light to a photodiode, the temporal variation of the output of which bears a known relationship with the rate of quenching of fluorescence and, hence, with the partial pressure of oxygen. The outputs of the sensors are digitized, preprocessed by a small onboard computer, and then sent wirelessly to a desktop computer, where the collected data are analyzed and displayed. In addition to the raw data on temperature, pressure, flow, and mole fractions of oxygen and carbon dioxide, the display can include volumetric oxygen consumption, volumetric carbon dioxide production, respiratory equivalent ratio, and volumetric flow rate of exhaled gas.

Dietrich, Daniel L.↗

High-voltage (900 V) 4 H-SiC Schottky diodes with a boron-implanted guard p-n junction

High-voltage (900 V) 4H-SiC Schottky diodes terminated with a guard p-n junction were fabricated and studied. The guard p-n junction was formed by room-temperature boron implantation with subsequent high-temperature annealing. Due to transient enhanced boron diffusion during annealing, the depth of the guard p-n junction was equal to about 1.7 {mu}m, which is larger by approximately 1 {mu}m than the projected range of 11 B ions in 4H-SiC. The maximum reverse voltage of fabricated 4H-SiC Schottky diodes is found to be limited by avalanche breakdown of the planar p-n junction; the value of the breakdown voltage (910 V) is close to theoretical estimate in the case of the impurity concentration N = 2.5 Multiplication-Sign 10{sup 15} cm{sup -3} in the n-type layer, thickness of the n-type layer d = 12.5 {mu}m, and depth of the p-n junction r{sub j} = 1.7 {mu}m. The on-state diode resistance (3.7 m{Omega} cm{sup 2}) is controlled by the resistance of the epitaxial n-type layer. The recovery charge of about 1.3 nC is equal to the charge of majority charge carriers that are swept out of an epitaxial n-type layer under the effect of a reverse voltage.

36 MATERIALS SCIENCE↗

Terrestrial Sources of X-Ray Radiation and Their Effects on NASA Flight Hardware

X-rays are an energetic and penetrating form of ionizing electromagnetic radiation, which can degrade NASA flight hardware. The main concern posed by such radiation is degradation of active electronic devices and, in some cases, diodes. Non-electronic components are only damaged at doses that far exceed the point where any electronic device would be destroyed. For the purposes of this document, flight hardware can be taken to mean an entire instrument, the flight electronics within the instrument or the individual microelectronic devices in the flight electronics. This document will discuss and describe the ways in which NASA flight hardware might be exposed to x-rays, what is and isn't a concern, and how to tell the difference. First, we must understand what components in flight hardware may be vulnerable to degradation or failure as a result of being exposed to ionizing radiation, such as x-rays. As stated above, bulk materials (structural metals, plastics, etc.) are generally only affected by ionizing radiation at very high dose levels. Likewise, passive electronic components (e.g. resistors, capacitors, most diodes) are strongly resistant to exposure to x-rays, except at very high doses. The main concerns arise when active components, that is, components like discrete transistors and microelectronic devices, are exposed to ionizing radiation. Active components are designed to respond to minute changes in currents and voltages in the circuit. As such, it is not surprising that exposure to ionizing radiation, which creates ionized and therefore electrically active particles, may degrade the way the hardware performs. For the most part, the mechanism for this degradation is trapping of the charges generated by ionizing radiation by defects in dielectric materials in the hardware. As such, the degree of damage is a function of both the quantity of ionizing radiation exposure and the physical characteristics of the hardware itself. The metric that describes the level of exposure to ionizing radiation is total ionizing dose (TID). The unit of TID is the rad, which is defined as 100 ergs absorbed per gram of material. Dose can be expressed in other units, for example grays (gy), where 1 gy = 100 rads. The actual fluence of radiation needed to deliver a rad depends on the absorbing material, so units of dose are usually stated in reference to the material of interest. That is, for microelectronic devices, the unit of dose is generally rad (Si) or rad (SiO2). However, the definition of absorbed dose in this fashion has the advantage that the type of radiation causing the ionization can be normalized so that a realistic and adequate comparison can be made. The sensitivity of microelectronic parts to TID varies over many orders of magnitude. (Note: Doses to humans are typically expressed in rems-or roentgen-equivalent-man-which measures tissue damage, and depends on the type of radiation, as well as the dose in rads.) Thus far, the "softest" parts tested at NASA showed damage at 500 rads (Si), while parts that are radiation-hardened by design can remain functional to doses on the order of 107 rads (Si). This broad range of sensitivity highlights one of the most important considerations when considering the effects of radiation on electronic parts: In order to determine whether a radiation exposure is a concern for a particular part, one must understand the technologies used in the part and their vulnerabilities to TID damage. A NASA radiation expert should be consulted to obtain such information.

X-ray↗

Effect of the concentration of uncompensated impurities on the properties of CdTe-based X- and {gamma}-ray detectors

Measurements of the {sup 55}Fe-isotope emission spectra and the photosensitivity of CdTe detectors with a Schottky diode, and also the temperature dependence of the resistivity of a CdTe crystal ((2-3) Multiplication-Sign 10{sup 9} {Omega}cm at 300 K) have been used to determine the concentration of uncompensated donors (1-3) Multiplication-Sign 10{sup 12} cm{sup -3}. Similar measurements performed for Cd{sub 0.9}Zn{sub 0.1}Te crystals with the resistivity (3-5) Multiplication-Sign 10{sup 10} {Omega} cm at 300 K have shown that the concentration of uncompensated donors in this case is lower by approximately four orders of magnitude. The results of calculations show that, due to such a significant decrease in the concentration of uncompensated donors, the efficiency of X- and {gamma}-ray radiation detection in the photon energy range 59 to 662 keV can decrease by one-three orders of magnitude (depending on the photon energy and the lifetime of charge carriers in the space-charge region). The results obtained account for the apparent poor detecting properties of the Cd{sub 0.9}Zn{sub 0.1}Te detectors.

36 MATERIALS SCIENCE↗

High-voltage (900 V) 4 H-SiC Schottky diodes with a boron-implanted guard p-n junction

High-voltage (900 V) 4H-SiC Schottky diodes terminated with a guard p-n junction were fabricated and studied. The guard p-n junction was formed by room-temperature boron implantation with subsequent high-temperature annealing. Due to transient enhanced boron diffusion during annealing, the depth of the guard p-n junction was equal to about 1.7 {mu}m, which is larger by approximately 1 {mu}m than the projected range of 11 B ions in 4H-SiC. The maximum reverse voltage of fabricated 4H-SiC Schottky diodes is found to be limited by avalanche breakdown of the planar p-n junction; the value of the breakdown voltage (910 V) is close to theoretical estimate in the case of the impurity concentration N = 2.5 x 10{sup 15} cm{sup -3} in the n-type layer, thickness of the n-type layer d = 12.5 {mu}m, and depth of the p-n junction r{sub j} = 1.7 {mu}m. The on-state diode resistance (3.7 m{omega} cm{sup 2}) is controlled by the resistance of the epitaxial n-type layer. The recovery charge of about 1.3 nC is equal to the charge of majority charge carriers that are swept out of an epitaxial n-type layer under the effect of a reverse voltage.

36 MATERIALS SCIENCE↗

Absolute spectral characterization of silicon barrier diode: Application to soft X-ray fusion diagnostics at Tore Supra

This paper presents an experimental protocol for absolute calibration of photo-detectors. Spectral characterization is achieved by a methodology that unlike the usual line emissions-based method, hinges on the Bremsstrahlung radiation of a Soft X-Ray (SXR) tube only. Although the proposed methodology can be applied virtually to any detector, the application presented in this paper is based on Tore Supra's SXR diagnostics, which uses Silicon Surface Barrier Diodes. The spectral response of these n-p junctions had previously been estimated on a purely empirical basis. This time, a series of second-order effects, like the spatial distribution of the source radiated power or multi-channel analyser non linearity, are taken into account to achieve accurate measurements. Consequently, a parameterised physical model is fitted to experimental results and the existence of an unexpected dead layer (at least 5 {mu}m thick) is evidenced. This contribution also echoes a more general on-going effort in favour of long-term quality of passive radiation measurements on Tokamaks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High average power, highly brilliant laser-produced plasma source for soft X-ray spectroscopy

In this work, a novel laser-produced plasma source is presented which delivers pulsed broadband soft X-radiation in the range between 100 and 1200 eV. The source was designed in view of long operating hours, high stability, and cost effectiveness. It relies on a rotating and translating metal target and achieves high stability through an on-line monitoring device using a four quadrant extreme ultraviolet diode in a pinhole camera arrangement. The source can be operated with three different laser pulse durations and various target materials and is equipped with two beamlines for simultaneous experiments. Characterization measurements are presented with special emphasis on the source position and emission stability of the source. As a first application, a near edge X-ray absorption fine structure measurement on a thin polyimide foil shows the potential of the source for soft X-ray spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High electrical conductivity and carrier mobility in oCVD PEDOT thin films by engineered crystallization and acid treatment

Air-stable, lightweight, and electrically conductive polymers are highly desired as the electrodes for next-generation electronic devices. However, the low electrical conductivity and low carrier mobility of polymers are the key bottlenecks that limit their adoption. We demonstrate that the key to addressing these limitations is to molecularly engineer the crystallization and morphology of polymers. We use oxidative chemical vapor deposition (oCVD) and hydrobromic acid treatment as an effective tool to achieve such engineering for conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT). We demonstrate PEDOT thin films with a record-high electrical conductivity of 6259 S/cm and a remarkably high carrier mobility of 18.45 cm 2 V -1 s -1 by inducing a crystallite-configuration transition using oCVD. Subsequent theoretical modeling reveals a metallic nature and an effective reduction of the carrier transport energy barrier between crystallized domains in these thin films. To validate this metallic nature, we successfully fabricate PEDOT-Si Schottky diode arrays operating at 13.56 MHz for radio frequency identification (RFID) readers, demonstrating wafer-scale fabrication compatible with conventional complementary metal-oxide semiconductor (CMOS) technology. The oCVD PEDOT thin films with ultrahigh electrical conductivity and high carrier mobility show great promise for novel high-speed organic electronics with low energy consumption and better charge carrier transport.

36 MATERIALS SCIENCE↗

Fabricating Graphene Oxide/h-BN Metal Insulator Semiconductor Diodes by Nanosecond Laser Irradiation

To employ graphene’s rapid conduction in 2D devices, a heterostructure with a broad bandgap dielectric that is free of traps is required. Within this paradigm, h-BN is a good candidate because of its graphene-like structure and ultrawide bandgap. We show how to make such a heterostructure by irradiating alternating layers of a-C and a-BN film with a nanosecond excimer laser, melting and zone-refining constituent layers in the process. With Raman spectroscopy and ToF-SIMS analyses, we demonstrate this localized zone-refining into phase-pure h-BN and rGO films with distinct Raman vibrational modes and SIMS profile flattening after laser irradiation. Furthermore, in comparing laser-irradiated rGO-Si MS and rGO/h-BN/Si MIS diodes, the MIS diodes exhibit an increased turn-on voltage (4.4 V) and low leakage current. The MIS diode I-V characteristics reveal direct tunneling conduction under low bias and Fowler-Nordheim tunneling in the high-voltage regime, turning the MIS diode ON with improved rectification and current flow. This study sheds light on the nonequilibrium approaches to engineering h-BN and graphene heterostructures for ultrathin field effect transistor device development.

2D materials↗

Development for application of parylene coatings

A practical method of applying a parylene (paraxylene) coating to hybrid microcircuit devices was developed for the prevention of circuit malfunctions existing prior to package sealing or formed upon exposure to the service environment. It was found that paralene and an associated primer (if used) had generally little or no adverse effect on the active and passive elements of typical hybrid microcircuits. Exceptions were related to high frequency circuitry, low resistivity thick film resistors, and highly sensitive PIN diodes. Advantages of the use of the coating included increased dielectric strength and increased interconnection bond strength. Coating service life in nitrogen or nitrogen with low levels of oxygen as a contaminant is shown to be in excess of 1000 hours at 150 C and can be projected to be in excess of 5000 hours at 125 C.

Oberin, F. W.↗

Theory of active mode locking of a semiconductor laser in an external cavity

An analytical treatment is given for the active mode locking of a semiconductor laser in an external resonator. The width of the mode-locked pulses is obtained as a function of the laser and cavity parameters and the amount of frequency detuning. The effects of self-modulation and saturation are included in the treatment. The pulse output is compared with that obtained by a strong modulation of the laser diode with no external cavity.

Yeung, J. A.↗

The 12 micron band of ethane: A spectral catalog from 765 cm(-1) to 900 cm(-1)

The high resolution laboratory absorption spectrum of the 12 micro band of ethane gas is studied. The data were obtained using the McMath Solar Telescope 1 meter Fourier Transform interferometer at Kitt Peak National Observatory and tunable diode laser spectrometers at the University of Tennessee and NASA/Goddard Space Flight Center. Over 200 individual vibration rotation transitions were analyzed taking into account many higher order effects including torsional splitting. Line positions were reproduced to better than 0.001/cm. Both ground and upper state molecular constants were determined in the analysis. The experimental details, the analysis procedures and the results are addressed. A list of ethane transitions occurring near (14)CO2 laser lines needed for heterodyne searches for C2H6 in extraterrestrial sources is also included. A spectral catalog of the ethane nu sub g fundamental from 765/cm to 900/cm is provided. A high dispersion (1/cm 12 in.) plot of both the Kitt Peak interferometric data and a simulated spectrum with Doppler limited resolution, a table of over 8500 calculated transitions listed quantum number assignments, frequencies and intensities are provided.

Atakan, A. K.↗