Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data quality assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Methods for trend analysis: Examples with problem/failure data

Statistics are emphasized as an important role in quality control and reliability. Consequently, Trend Analysis Techniques recommended a variety of statistical methodologies that could be applied to time series data. The major goal of the working handbook, using data from the MSFC Problem Assessment System, is to illustrate some of the techniques in the NASA standard, some different techniques, and to notice patterns of data. Techniques for trend estimation used are: regression (exponential, power, reciprocal, straight line) and Kendall's rank correlation coefficient. The important details of a statistical strategy for estimating a trend component are covered in the examples. However, careful analysis and interpretation is necessary because of small samples and frequent zero problem reports in a given time period. Further investigations to deal with these issues are being conducted.

Church, Curtis K.↗

Performance seeking control excitation mode

Flight testing of the performance seeking control (PSC) excitation mode was successfully completed at NASA Dryden on the F-15 highly integrated digital electronic control (HIDEC) aircraft. Although the excitation mode was not one of the original objectives of the PSC program, it was rapidly prototyped and implemented into the architecture of the PSC algorithm, allowing valuable and timely research data to be gathered. The primary flight test objective was to investigate the feasibility of a future measurement-based performance optimization algorithm. This future algorithm, called AdAPT, which stands for adaptive aircraft performance technology, generates and applies excitation inputs to selected control effectors. Fourier transformations are used to convert measured response and control effector data into frequency domain models which are mapped into state space models using multiterm frequency matching. Formal optimization principles are applied to produce an integrated, performance optimal effector suite. The key technical challenge of the measurement-based approach is the identification of the gradient of the performance index to the selected control effector. This concern was addressed by the excitation mode flight test. The AdAPT feasibility study utilized the PSC excitation mode to apply separate sinusoidal excitation trims to the controls - one aircraft, inlet first ramp (cowl), and one engine, throat area. Aircraft control and response data were recorded using on-board instrumentation and analyzed post-flight. Sensor noise characteristics, axial acceleration performance gradients, and repeatability were determined. Results were compared to pilot comments to assess the ride quality. Flight test results indicate that performance gradients were identified at all flight conditions, sensor noise levels were acceptable at the frequencies of interest, and excitations were generally not sensed by the pilot.

Schkolnik, Gerard↗

A Validation of Object-Oriented Design Metrics as Quality Indicators

This paper presents the results of a study in which we empirically investigated the suits of object-oriented (00) design metrics introduced in another work. More specifically, our goal is to assess these metrics as predictors of fault-prone classes and, therefore, determine whether they can be used as early quality indicators. This study is complementary to the work described where the same suite of metrics had been used to assess frequencies of maintenance changes to classes. To perform our validation accurately, we collected data on the development of eight medium-sized information management systems based on identical requirements. All eight projects were developed using a sequential life cycle model, a well-known 00 analysis/design method and the C++ programming language. Based on empirical and quantitative analysis, the advantages and drawbacks of these 00 metrics are discussed. Several of Chidamber and Kamerer's 00 metrics appear to be useful to predict class fault-proneness during the early phases of the life-cycle. Also, on our data set, they are better predictors than 'traditional' code metrics, which can only be collected at a later phase of the software development processes.

Basili, Victor R.↗

6S Return Samples: Assessment of Air Quality in the International Space Station (ISS) Based on Solid Sorbent Air Sampler (SSAS) and Formaldehyde Monitoring Kit (FMK) Analyses

The toxicological assessments of SSAS and FMK analytical results are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the SSAS tubes were 66-76% for 13C-acetone, 85-96% for fluorobenzene, and 73-89% for chlorobenzene. Post-flight flows were far below pre-flight flows and an investigation of the problem revealed that the reduced flow was caused by a leak at the interface of the pump inlet tube and the pump head. This resulted in degradation of pump efficiency. Further investigation showed that the problem occurred before the SSAS was operated on orbit and that use of the post-flight flows yielded consistent and useful results. Recoveries from formaldehyde control badges were 86 to 104%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). The T values will not be reported for these data due to the flow anomaly. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Octafluoropropane (OFP) is not efficiently trapped by the sorbents used in the SSAS. Because formaldehyde is quantified from sorbent badges, its concentration is also listed separately. These five indices of air quality are summarized.

James, John T.↗

Digital Beamforming Based RFI Mitigation for Synthetic Aperture Radar

An increasing challenge for P-band Synthetic Aperture Radar (SAR) is Radio Frequency Interference (RFI). RFI results in image distortions and degrades the derived science products. This makes it critical to apply RFI removal techniques to restore the image quality. New advanced techniques can be achieved with Digital Beamforming (DBF) radars such as EcoSAR. In this paper, we present a Range-Dependent Time Minimum Variance Distortionless Response (RDTMVDR) Beamformer and apply it to EcoSAR flight data during post-processing. The antenna pattern (AP) is adaptively changed for each range line which increases the RFI suppression compared to a fixed AP for each pulse. The interferometric image quality is assessed before and after RFI suppression.

Bollian, Tobias↗

Experiment Isotopic Data Compiled by the OECD/NEA Expert Group on Assay Data for Spent Nuclear Fuel

An essential component of computational modeling and simulation is the availability of well-qualified experimental benchmark data against which calculation systems can be validated and the bias and uncertainty associated with the codes and data can be evaluated. The validation process is extremely important for safety and licensing to demonstrate that adequate margins for uncertainty have been included in the calculations. For safety evaluations involving spent nuclear fuel, the isotopic compositions and resulting activities calculated using depletion and decay codes must be validated against experimental determinations of the spent fuel content. In this process the isotopic concentrations predicted by the codes should be compared with corresponding measurements of spent fuel made by destructive analysis as a fundamental part of any code performance evaluation. In recent years there has been growing international interest in acquiring high-quality assay data that can be used to validate code calculations, particularly for modern fuel designs and high burnup fuels and for a wider range of nuclides important to nuclear criticality safety, radiological safety assessments, and decay heat. Assay data are required to validate a broad range of reactor and fuel-cycle applications, including reactor core simulation, postulated severe accident analysis, spent fuel handling, spent fuel transportation and interim storage, reprocessing, nuclear safeguards, and final fuel repository evaluations. In some cases researchers working on depletion code development have noted a general lack of available assay measurements that can be used to benchmark and validate their code calculations for spent fuel compositions. This perception is due in part to the fact that data have been reported in diverse publications over many years, many experimental reports are difficult to access, and there has not been a concerted and funded effort to compile and consolidate available measurements that can be easily accessed by code developers and analysts for validation. In response to the increased interest in fuel isotopic measurements and needs for consolidation and documentation of available data, an Expert Group on Assay Data for Spent Nuclear Fuel (EGADSNF) was formed in 2007 as a working group of the Organisation for Economic Cooperation and Development (OECD)/Nuclear Energy Agency (NEA) Working Party on Nuclear Criticality Safety (WPNCS). Although the group was formed by the Expert Group on Burnup Credit to coordinate isotopic assay data activities and facilitate collaboration between countries developing or implementing burnup credit in their nuclear criticality safety methodologies, the group recognized the need and value of assay data for a broad range of spent fuel applications, and the EGADSNF includes members representing not only the WPNCS, but also members from the standing technical Committee on the Safety of Nuclear Installations and the Integration Group for the Safety Case of the Radioactive Waste Management Committee. Member countries currently active in the EGADSNF include Belgium, the Czech Republic, France, Germany, Japan, Slovakia, Spain, Sweden, the United Kingdom, and the United States. The experimental database of spent fuel measurements maintained by the OECD/NEA is web-accessible. SFCOMPO (database of Spent Fuel Compositions) contains measured isotopic data, mostly for light water reactor (LWR) fuels, for about 250 fuel samples. This paper summarizes the status of SFCOMPO and current activities to expand and improve the database.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TU-AB-204-00: Advances in Cone-Beam CT and Emerging Applications

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

TU-AB-204-01: Advances in C-Arm CBCT for Brain Perfusion Imaging

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

TU-AB-204-02: Advances in C-Arm CBCT for Cardiac Interventions

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

TU-AB-204-03: Advances in CBCT for Orhtopaedics and Bone Health Imaging

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

TU-AB-204-04: Advances in CBCT for Breast Imaging

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

Bayesian Geostatistical Modelling of PM10 and PM2.5 Surface Level Concentrations in Europe Using High-Resolution Satellite-Derived Products

Air quality monitoring across Europe is mainly based on in situ ground stations which are too sparse to accurately assess the exposure effects of air pollution for the entire continent. The demand for precise predictive modelsthat estimate gridded geophysical parameters of ambient air at high spatial resolution has rapidly grown. Here, we investigate the potential of satellite derived products to improve particulate matter (PM) estimates. Bayesiangeostatistical models addressing confounding between the spatial distribution of pollutants and remotely sensed predictors were developed to estimate yearly averages of both, fine (PM2.5) and coarse (PM10) surface PM concentrations at 1 sq.km spatial resolution over 46 European countries and were compared to geostatistical, geographically weighted and land-use regression formulations. Rigorous model selection identified the Earth observation data which contribute most to pollutants' estimation. Geostatistical models outperformed the predictive ability of the frequently employed land-use regression. The resulting estimates of PM10 and PM2.5, which represent the main air quality indicators for the urban Sustainable Development Goal, indicate that in 2016, 66.2% of the European population was breathing air above the WHO Air Quality Guidelines thresholds. Our estimates are readily available to policy makers and scientists assessing the effects of long-term exposure to pollution on human and ecosystem health.

Beloconi, Anton↗

Dataset: "Widespread Drought-driven Declines in Streamflows and Water quality in the Upper Colorado River Basin (1998-2022)"

This data package contains the associated data and scripts for Nagamoto, E., Ombadi, M., Ciulla, F. et al. Widespread drought-driven declines in streamflows and water quality in the Upper Colorado River Basin during 1998-2022. Commun Earth Environ 7, 734 (2026). https://doi.org/10.1038/s43247-026-03890-5. This purpose of this study was to investigate the impact of the 21st century drought on water quantity and quality at catchments throughout the Upper Colorado River Basin (UCRB). We used stream flow, water temperature, specific conductance, air temperature, precipitation, and catchment attribute data for over 200 sites in the UCRB, collected from the National Water Information System using Basin3D (Varadharajan, 2023), GAGESII (Falcone, 2010), and the Google Earth Engine. We identified years of severe drought between 1998 and 2022 using the Standardized Precipitation Evaporation Index (SPEI), then calculated the relative change percentage of the stream flow, water temperature, and specific conductance from drought versus non-drought years. We used the attribute information from GAGESII to investigate what physical traits of catchments are associated streamflow vulnerability (greater relative change) or resilience to drought. We used land cover data from the National Land Cover Database (USGS, 2024) to assess any changes to physical attributes that may not be represented in the static attributes information in GAGESII. To increase data availability, we modeled stream temperature using methods from Willard, 2023. While the study period is water years 1998 to 2022, the raw water quantity and quality data extends to 1950 and the meteorological data extends to 1980. The data and code can be downloaded via the UCRB_drought.zip. Within the zip, the files are organized as follows: - INPUTS: Contains all input data used in UCRB_Drought_Workflow.ipynb - OUTPUTS: Contains all intermediate data created from UCRB_Drought_Workflow.ipynb as well as final products including the calculated Standardized Evapotranspiration Index (SPEI) - climatic_variables: The code used to collect meteorologic data from Google Earth Engine - feature_importance: The code used for the catchment attributes analysis - preprocessing: Code used in UCRB_Drought_Workflow_Preprocessing.ipynb - pyeto: Code used in UCRB_Drought_Workflow_Preprocessing.ipynb - calculations: Code used in UCRB_Drought_Workflow_Impacts.ipynb - plotting: Code used in UCRB_Drought_Workflow_Impacts.ipynb - README.md - UCRB_Drought_Workflow_Preprocessing.ipynb: The code used to prep raw data for the analysis - UCRB_Drought_Workflow_Impact.ipynb: The code which uses the prepped raw data for analysis, and plots all figures - requirements_ucrb-drought_v2.yml: The requirements file to create a virtual environment and Jupyter Lab kernel to run the code The INPUTS folder is organized into the following major directories and sub-directories. The "RDC_WT_SC_RAW" folder contains raw data for streamflow, water temperature, and specific conductance in a ".h5" file. The "NLCD_RAW" folder contains ".csv" files with annual land cover percentages for counties within the UCRB. The "MET_RAW" folder contains a ".csv" file with monthly meteorological data (air temperature and precipitation) for the sites in the UCRB which was obtained from code in the climatic_variables folder. The "GAGESII" folder contains ".csv" files with physical catchment attribute variables for catchments across the country. The "WT_LSTM_data" folder contains ".csv" files with calculated WT (Willard, 2023) and the associated RMSEs. The "Upper_Colorado_River_Basin_Boundary" folder contains geographic data including a shapefile for plotting in the UCRB_Drought_Workflow.ipynb. The "RESERVOIRS_RAW" folder contains ".csv" files for each reservoir in the UCRB with daily reservoir storage. There are also two files in the INPUTS folder that have combined reservoir storage data and reservoir metadata. The OUTPUTS folder is organized into the following major directories and sub-directories. The "RDC_WT_SC_data" folder contains a folder "Water_year" with the associated cleaned data, metadata, and data availability information in ".csv" files, a folder "Median_Relchange" with the relative change comparing drought to non-drought years in ".csv" files, and a folder "Peak95_Min5_Relchange" that has ".csv" files for the relative change in peak (95th %) and minimum (5th %) variables. The "NLCD_data" folder contains the difference in land cover from the beginning to end of the study period and the percentage of the county that is within UCRB bounds can be found in Nagamoto et al (2025)). The "MET_data" folder contains separated monthly air temperature and precipitation data and the calculated PET in ".csv" files. The "SPEI_data" folder contains ".csv" files with calculated SPEI values (one restricted to the study period and the other with information from the entire MET data period). The "Paper_Tables" folder contains two ".csv" files containing site information and data availability and information about the GAGESII trait aggregated categories. The base directory includes the file “flmd.csv” for a list and description of all files and the file “dd.csv” for data dictionaries. Scripts for preprocessing, analysis, and figure generation are located in the associated GitHub repository found at [https://github.com/iNAIADS/drought-impacts/tree/develop/UCRB-drought]. UPDATE 1: Title and code file updated to match submitted manuscript 10-15-2025. UPDATE 2: Code and data files updated to match revised manuscript 3-4-2026. UPDATE 3: Code and data files updated to match revised manuscript 6-7-2026. ** NOTE: DD and FLMD have not been updated yet. UPDATE 4: Added associated Manuscript information and DD and FLMD have been updated. To cite this code, please use the following BibTeX: @misc{nagamoto2025drought, author = {Emily Nagamoto and Fabio Ciulla and Mohammad Ombadi and Jared Willard and Rosemary Carroll and Charuleka Varadharajan}, title = {Dataset: "Widespread Drought-driven Declines in Streamflows and Water quality in the Upper Colorado River Basin (1998-2022)"}, year = {2025}, doi = {10.15485/2551894}, publisher = {ESS-DIVE Repository}, url = {https://data.ess-dive.lbl.gov/datasets/doi:10.15485/2551894} }

54 ENVIRONMENTAL SCIENCES↗

Electrical substation grid testbed for DLT applications of electrical fault detection, power quality monitoring, DERs use cases and cyber-events

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation, and are associated with customer-owned distributed energy resources (DERs). The integrity and confidentiality of data from these IEDs, like power meters and protective relays, is crucial. Blockchain technology could improve the resilience of microgrids by improving the security of data sharing. The penetration of customer-owned DERs (renewable energy sources) and the increasing deployment of IEDs can lead to integrate power system applications with Distributed Ledger Technology (DLT). In this study, we implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in-the-loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results had shown the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, the ESGT with DERs and the CGG system will be used in other power system applications, based on implementing smart contracts between electrical utilities with customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary results of an assessment of FGGE 'special effort' data and its impact on GLAS model analyses and forecasts

Attempts to improve the handling of satellite temperature and cloud-derived data during the FGGE experiment are compared with results gained during the trials. The satellite data were edited by assigning quality indicators to temperature soundings by means of the IR TV camera on the Tiros-N spacecraft, and to cloud-tracked wind data from GEO satellites. The data quality were assayed on the basis of horizontal, vertical, and temporal consistency of observed synoptic conditions. The data interpreter-operator retrieved all available data for an area, determined which regions were data-sparse, then used data-rich areas nearby to supply smoothed gradients into the zones with insufficient data. Results are presented for measurements taken during Jan.-Feb., and May 1979 over Alaska. It was found that enhanced and operational IR soundings were mostly equivalent. Some improvements were implemented in the 1000-300 mb layer thickness and intensification of atmospheric thermal gradients. Interactive processing was concluded to be an aid to processing Tiros-N data. The data-improvements treatment was found to significantly modify large scale analyses.

Atlas, R.↗

Comparative Performance of Three Eye-Tracking Devices in Detection of Mild Traumatic Brain Injury in Acute Versus Chronic Subject Populations

ABSTRACT Introduction Presently, traumatic brain injury (TBI) triage in field settings relies on symptom-based screening tools such as the updated Military Acute Concussion Evaluation. Objective eye-tracking may provide an alternative means of neurotrauma screening due to sensitivity to neurotrauma brain-health changes. Previously, the US Army Medical Research and Development Command Non-Invasive NeuroAssessment Devices (NINAD) Integrated Product Team identified 3 commercially available eye-tracking devices (SyncThink EYE-SYNC, Oculogica EyeBOX, NeuroKinetics IPAS) as meeting criteria toward being operationally effective in the detection of TBI in service members. We compared these devices to assess their relative performance in the classification of mild traumatic brain injury (mTBI) subjects versus normal healthy controls. Materials and Methods Participants 18 to 45 years of age were assigned to Acute mTBI, Chronic mTBI, or Control group per study criteria. Each completed a TBI assessment protocol with all 3 devices counterbalanced across participants. Acute mTBI participants were tested within 72 hours following injury whereas time since last injury for the Chronic mTBI group ranged from months to years. Discriminant analysis was undertaken to determine device classification performance in separating TBI subjects from controls. Area Under the Curves (AUCs) were calculated and used to compare the accuracy of device performance. Device-related factors including data quality, the need to repeat tests, and technical issues experienced were aggregated for reporting. Results A total of 63 participants were recruited as Acute mTBI subjects, 34 as Chronic mTBI subjects, and 119 participants without history of TBI as controls. To maximize outcomes, poorer quality data were excluded from analysis using specific criteria where possible. Final analysis utilized 49 (43 male/6 female, mean [x̅] age = 24.3 years, SD [s] = 5.1) Acute mTBI subjects, and 34 (33 male/1 female, x̅ age = 38.8 years, s = 3.9) Chronic mTBI subjects were age- and gender-matched as closely as possible with Control subjects. AUCs obtained with 80% of total dataset ranged from 0.690 to 0.950 for the Acute Group and from 0.753 to 0.811 for the Chronic mTBI group. Validation with the remaining 20% of dataset produced AUCs ranging from 0.600 to 0.750 for Acute mTBI group and 0.490 to 0.571 for the Chronic mTBI group. Conclusions Potential eye-tracking detection of mTBI, per training model outcomes, ranged from acceptable to excellent for the Acute mTBI group; however, it was less consistent for the Chronic mTBI group. The self-imposed targeted performance (AUC of 0.850) appears achievable, but further device improvements and research are necessary. Discriminant analysis models differed for the Acute versus Chronic mTBI groups, suggesting performance differences in eye-tracking. Although eye-tracking demonstrated sensitivity in the Chronic group, a more rigorous and/or longitudinal study design is required to evaluate this observation. mTBI injuries were not controlled for this study, potentially reducing eye-tracking assessment sensitivity. Overall, these findings indicate that while eye-tracking remains a viable means of mTBI screening, device-specific variability in data quality, length of testing, and ease of use must be addressed to achieve NINAD objectives and DoD implementation.

General & Internal Medicine↗

Data from : "Warming promotes loss of subsoil carbon through accelerated degradation of plant-derived organic matter". Blodgett warming experiment

This dataset contains data used for the paper: Warming promotes loss of subsoil carbon through accelerated degradation of plant-derived organic matter. Soil Biology and Biochemistry 156, 108185. doi:10.1016/j.soilbio.2021.108185On April 2018 (after 4.5 years of warming), we collected O-horizon (organic horizon) material and soil core down to 90 cm depth from a whole-soil warming experiment in a mixed-coniferous temperate forest, located at the University of California Blodgett experimental forest in the foothills of the Sierra Nevada, CA USA. The goal was to assess how 4.5 years of +4 °C whole-soil warming affected the quantity and quality of soil organic matter. Cores were collected from 6 experimental plots (three replicated blocks); samples were collected in 10 cm increments from 0 to 90 cm depth.This dataset contains a compressed (.zip) archive of the data used for this manuscript. The dataset includes files in .xlsx format, which can be accessed and processed using MS Excel or R. Carbon and nitrogen concentrations, as well as stable carbon isotope composition ((δ13C) and solvent extractable lipid biomarker (alkanoic acids and alkanes) data are provided as processed data files. Diffuse reflectance infrared Fourier transform (DRIFT) spectroscopy data are provided as raw output and processed data files.The dataset files "Blodgett_warming_Data" and "Blodgett_warming_raw_data.xlsx" were updated on July 7, 2021. The following updates were made: (1) specification of the units of measurements in the dataset (the unit of measurement was missing in some parameters) and (2) the column name "pulled depth" was changed to "pooled depth" in the updated data files.

54 ENVIRONMENTAL SCIENCES↗

An Assessment of and Access to NASA CERES Hourly Solar Irradiance Data Products Using POWER Web Services

The National Aeronautics and Space Administration’s (NASA) Clouds and Earth’s Radiant Energy System (CERES) Mission has been providing surface solar irradiance data products since March 2000. With an emphasis on global climate quality data products, CERES produces a suite of data parameters related to both the inputs and the observed and measured solar irradiance components at the top-of-atmosphere and at the surface. This paper discusses the global CERES SYN1Deg (Synoptic 1x1 degree resolution) solar irradiance data products, shows that the accuracy of the global horizontal irradiance (GHI) at the hourly time scale is <1% for bias and 24% RMS compared to the Baseline Surface Radiation Network (BSRN) measurements. This paper then shows the accuracy of the direct and diffuse components and a proposed “bias” correction based upon the solar zenith angle dependence that provides accuracy useful for solar applications on a global basis for all sunlit conditions. Lastly, a brief description of how to obtain these hourly solar irradiance products based upon SYN1Deg using the NASA’s Prediction of Worldwide Energy Resource (POWER) web services portal is given so users can utilize these estimates for testing and evaluation.

Surface solar irradiance↗