Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

CrystalPlan: an Experiment Planning Tool for Crystallography

Beam time at large user program based x-ray and neutron scattering facilities is in high demand and always at a premium. CrystalPlan, a highly efficient experiment planning software has been developed to maximize the use of available beamtime per sample per experiment. This program can calculate and optimize the data coverage of a crystal in reciprocal space in a single-crystal diffraction time-of- flight experiment. CrystalPlan can help a user build an experiment plan that will acquire the most data possible, with sufficient coverage but limited redundancy, therefore increasing scientific productivity. A user friendly GUI including a 3D viewer, an automated coverage optimizer, and an option to reorient the crystal for the measurement of selected hkls on specific detector positions are among its useful features. A sample use case of the program with the TOPAZ beamline at SNS will be presented.

data collection strategy↗

A new variable-resolution associative memory for high energy physics

We describe an important advancement for the Associative Memory device (AM). The AM is a VLSI processor for pattern recognition based on Content Addressable Memory (CAM) architecture. The AM is optimized for on-line track finding in high-energy physics experiments. Pattern matching is carried out by finding track candidates in coarse resolution 'roads'. A large AM bank stores all trajectories of interest, called 'patterns', for a given detector resolution. The AM extracts roads compatible with a given event during detector read-out. Two important variables characterize the quality of the AM bank: its 'coverage' and the level of fake roads. The coverage, which describes the geometric efficiency of a bank, is defined as the fraction of tracks that match at least one pattern in the bank. Given a certain road size, the coverage of the bank can be increased just adding patterns to the bank, while the number of fakes unfortunately is roughly proportional to the number of patterns in the bank. Moreover, as the luminosity increases, the fake rate increases rapidly because of the increased silicon occupancy. To counter that, we must reduce the width of our roads. If we decrease the road width using the current technology, the system will become very large and extremely expensive. We propose an elegant solution to this problem: the 'variable resolution patterns'. Each pattern and each detector layer within a pattern will be able to use the optimal width, but we will use a 'don't care' feature (inspired from ternary CAMs) to increase the width when that is more appropriate. In other words we can use patterns of variable shape. As a result we reduce the number of fake roads, while keeping the efficiency high and avoiding excessive bank size due to the reduced width. We describe the idea, the implementation in the new AM design and the implementation of the algorithm in the simulation. Finally we show the effectiveness of the 'variable resolution patterns' idea using simulated high occupancy events in the ATLAS detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extended Virtual Spring Mesh (EVSM): The Distributed Self-Organizing Mobile Ad Hoc Network for Area Exploration

Mobile Ad hoc NETworks (MANETs) are distributed self-organizing networks that can change locations and configure themselves on the fly. This paper focuses on an algorithmic approach for the deployment of a MANET within an enclosed area, such as a building in a disaster scenario, which can provide a robust communication infrastructure for search and rescue operations. While a virtual spring mesh (VSM) algorithm provides scalable, self-organizing, and fault-tolerant capabilities required by aMANET, the VSM lacks the MANET's capabilities of deployment mechanisms for blanket coverage of an area and does not provide an obstacle avoidance mechanism. This paper presents a new technique, an extended VSM (EVSM) algorithm that provides the following novelties: (1) new control laws for exploration and expansion to provide blanket coverage, (2) virtual adaptive springs enabling the mesh to expand as necessary, (3) adapts to communications disturbances by varying the density and movement of mobile nodes, and (4) new metrics to assess the performance of the EVSM algorithm. Simulation results show that EVSM provides up to 16% more coverage and is 3.5 times faster than VSM in environments with eight obstacles.

42 ENGINEERING↗

Real-time scanning tunneling microscopy observations of the oxidation of a Ti/Pt(111)-(2x2) surface alloy using O{sub 2} and NO{sub 2}

The authors have used scanning tunneling microscopy (STM), low energy electron diffraction (LEED), and Auger electron spectroscopy (AES) to study the nascent oxidation of an ordered Ti/Pt(111)-(2x2) surface alloy exposed to oxygen (O{sub 2}) or nitrogen dioxide (NO{sub 2}) under ultrahigh vacuum conditions. The Ti/Pt(111)-(2x2) surface alloy was formed by depositing an ultrathin Ti film on Pt(111) and annealing to 1050 K. This produces an alloy film in which the surface layer is pure Pt and the second layer contains Ti atoms in a (2x2) structure, which causes the pattern observed by STM and LEED. Real-time imaging of the surface at 300 K was carried out by continuously scanning with the STM while either O{sub 2} or NO{sub 2} was introduced into the chamber. O{sub 2} exposures did not cause any gross structural changes; however oxygen was detected on the surface afterward using AES. Annealing this surface to 950 K resulted in the formation of an ordered TiO{sub x} overlayer as characterized by both LEED and STM. In contrast, NO{sub 2} exposures caused definite changes in the surface morphology at 300 K, and the root-mean-square roughness increased from 3.5 to 7.1 A after a large NO{sub 2} exposure. No ordered structures were produced by this treatment, but annealing the surface to 950 K formed an ordered pattern in LEED and corresponding clear, well-resolved structures in STM images. We account for these observations on the disruption or reconstruction of the Ti/Pt(111)-(2x2) surface alloy by arguments recalling that Ti oxidation is an activated process. The energetic barrier to TiO{sub x} formation cannot be surmounted at room temperature at low oxygen coverages, and annealing the surface was necessary to initiate this reaction. However, the higher oxygen coverages obtained using the more reactive oxidant NO{sub 2} lowered the chemical potential in the system sufficiently to overcome the activation barrier to extract Ti from the alloy at room temperature and form a disordered TiO{sub x} film. These results illustrate the importance of the surface oxygen coverage in nucleating the room temperature oxidation of the Pt-Ti surface alloys and further show the ability of NO{sub 2} in ultrahigh vacuum studies for probing the chemistry that will occur at higher O{sub 2} pressure.

36 MATERIALS SCIENCE↗

High temperature growth of Ag phases on Ge(111)

The growth of the (3 Multiplication-Sign 1) and ({radical}3 Multiplication-Sign {radical}3)R30 Degree-Sign phases of Ag on Ge(111) on substrates at temperatures from 540 to 660 Degree-Sign C is characterized with low energy electron microscopy (LEEM) and low energy electron diffraction (LEED). From 540 Degree-Sign C to the Ag desorption temperature of 575 Degree-Sign C, LEEM images show that growth of the (3 Multiplication-Sign 1) phase begins at step edges. Upon completion of the (3 Multiplication-Sign 1) phase, the ({radical}3 Multiplication-Sign {radical}3)R30 Degree-Sign phase is observed with a dendritic growth morphology that is not much affected by steps. For sufficiently high deposition rates, Ag accumulates on the sample above the desorption temperature. From 575 to 640 Degree-Sign C, the growth proceeded in a manner similar to that at lower temperatures, with growth of the (3 Multiplication-Sign 1) phase to completion, followed by growth of the ({radical}3 Multiplication-Sign {radical}3)R30 Degree-Sign phase. Increasing the substrate temperature to 660 Degree-Sign C resulted in only (3 Multiplication-Sign 1) growth. In addition, for samples with Ag coverage less than 0.375ML, LEEM and LEED images were used to follow a reversible phase transformation near 575 Degree-Sign C, between a mixed high coverage phase of [(4 Multiplication-Sign 4) + (3 Multiplication-Sign 1)] and the high temperature, lower coverage (3 Multiplication-Sign 1) phase.

36 MATERIALS SCIENCE↗

Spatial atomic layer deposition on flexible porous substrates: ZnO on anodic aluminum oxide films and Al{sub 2}O{sub 3} on Li ion battery electrodes

Spatial atomic layer deposition (S-ALD) was examined on flexible porous substrates utilizing a rotating cylinder reactor to perform the S-ALD. S-ALD was first explored on flexible polyethylene terephthalate polymer substrates to obtain S-ALD growth rates on flat surfaces. ZnO ALD with diethylzinc and ozone as the reactants at 50 °C was the model S-ALD system. ZnO S-ALD was then performed on nanoporous flexible anodic aluminum oxide (AAO) films. ZnO S-ALD in porous substrates depends on the pore diameter, pore aspect ratio, and reactant exposure time that define the gas transport. To evaluate these parameters, the Zn coverage profiles in the pores of the AAO films were measured using energy dispersive spectroscopy (EDS). EDS measurements were conducted for different reaction conditions and AAO pore geometries. Substrate speeds and reactant pulse durations were defined by rotating cylinder rates of 10, 100, and 200 revolutions per minute (RPM). AAO pore diameters of 10, 25, 50, and 100 nm were utilized with a pore length of 25 μm. Uniform Zn coverage profiles were obtained at 10 RPM and pore diameters of 100 nm. The Zn coverage was less uniform at higher RPM values and smaller pore diameters. These results indicate that S-ALD into porous substrates is feasible under certain reaction conditions. S-ALD was then performed on porous Li ion battery electrodes to test S-ALD on a technologically important porous substrate. Li{sub 0.20}Mn{sub 0.54}Ni{sub 0.13}Co{sub 0.13}O{sub 2} electrodes on flexible metal foil were coated with Al{sub 2}O{sub 3} using 2–5 Al{sub 2}O{sub 3} ALD cycles. The Al{sub 2}O{sub 3} ALD was performed in the S-ALD reactor at a rotating cylinder rate of 10 RPM using trimethylaluminum and ozone as the reactants at 50 °C. The capacity of the electrodes was then tested versus number of charge–discharge cycles. These measurements revealed that the Al{sub 2}O{sub 3} S-ALD coating on the electrodes enhanced the capacity stability. This S-ALD process could be extended to roll-to-roll operation for the commercialization of S-ALD for coating Li ion battery electrodes.

36 MATERIALS SCIENCE↗

Thermodynamics and kinetics of H adsorption and intercalation for graphene on 6 H -SiC(0001) from first-principles calculations

Previous experimental observations for H intercalation under graphene on SiC surfaces motivate the clarification of configuration stabilities and kinetic processes related to intercalation. From first-principles density-functional-theory calculations, we analyze H adsorption and intercalation for graphene on a 6H-SiC(0001) surface, where the system includes two single-atom-thick graphene layers: the top-layer graphene (TLG) and the underling buffer-layer graphene (BLG) above the terminal Si layer. Our chemical potential analysis shows that in the low-H coverage regime (described by a single H atom within a sufficiently large supercell), intercalation into the gallery between TLG and BLG or into the gallery underneath BLG is more favorable thermodynamically than adsorption on top of TLG. However, intercalation into the gallery between TLG and BLG is most favorable. We obtain energy barriers of about 1.3 and 2.3 eV for a H atom diffusing on and under TLG, respectively. From an additional analysis of the energy landscape in the vicinity of a step on the TLG, we assess how readily one guest H atom on the TLG terrace can directly penetrate the TLG into the gallery between TLG and BLG versus crossing a TLG step to access the gallery. Finally, we also perform density functional theory calculations for higher H coverages revealing a shift in favorability to intercalation of H underneath BLG and characterizing the variation with H coverage in interlayer spacings.

36 MATERIALS SCIENCE↗

Operando study of HfO 2 atomic layer deposition on partially hydroxylated Si(111)

The introduction of atomic layer deposition (ALD), to the microelectronics industry has introduced a large number of new possible materials able to be deposited in layers with atomic thickness control. One such material is the high-κ oxide HfO 2 ; thermally stable and ultrathin HfO 2 films deposited by ALD are a significant contender to replace SiO 2 as the gate oxide in capacitor applications. We present a mechanistic study of the first deposition cycle of HfO 2 on the Si(111) surface using tetrakis(dimethylamido) hafnium (TDMAHf) and water as precursors using operando ambient pressure x-ray photoelectron spectroscopy. Here, we show that the hydroxylation of the clean Si(111) surface by residual water vapor, resulting in a 0.3 monolayer coverage of hydroxyls, leads to instantaneous full surface coverage of TDMAHf. The change in the atomic ratio of Hf to C/N found during the first deposition half-cycle, however, does not match the assumed immediate ligand loss through reaction with surface hydroxyls. One would expect an immediate loss of ligands, indicated by a Hf:N ratio of approximately 1:3 as TDMAHf deposits onto the surface; however, a Hf:N ratio of 1:3.6 is observed. The partial hydroxylation on the Si(111) surface leads to binding through the TDMAHf ligand N atoms resulting in both N and CH 3 being found remaining on the surface post water half-cycle. Although there is evidence of ligand exchange reactions occurring at Si–OH sites, it also seems that N binding can occur on bare Si, highlighting the complexity of the substrate/precursor reaction even when hydroxyls are present. Moreover, the initial low coverage of Si–OH/Si–H appears to severely limit the amount of Hf deposited, which we hypothesize is due to the specific geometry of the initial arrangement of Si–OH/Si–H on the rest- and adatoms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

IMRT planning and delivery incorporating daily dose from mega-voltage cone-beam computed tomography imaging

The technology of online mega-voltage cone-beam (CB) computed tomography (MV-CBCT) imaging is currently used in many institutions to generate a 3D anatomical dataset of a patient in treatment position. It utilizes an accelerator therapy beam, delivered with 200 deg. gantry rotation, and captured by an electronic portal imager to account for organ motion and setup variations. Although the patient dose exposure from a single volumetric MV-CBCT imaging procedure is comparable to that from standard double-exposure orthogonal portal images, daily image localization procedures can result in a significant dose increase to healthy tissue. A technique to incorporate the daily dose, from a MV-CBCT imaging procedure, in the IMRT treatment planning optimization process was developed. A composite IMRT plan incorporating the total dose from the CB was optimized with the objective of ensuring uniform target coverage while sparing the surrounding normal tissue. One head and neck cancer patient and four prostate cancer patients were planned and treated using this technique. Dosimetric results from the prostate IMRT plans optimized with or without CB showed similar target coverage and comparable sparing of bladder and rectum volumes. Average mean doses were higher by 1.6{+-}1.0 Gy for the bladder and comparable for the rectum (-0.3{+-}1.4 Gy). In addition, an average mean dose increase of 1.9{+-}0.8 Gy in the femoral heads and 1.7{+-}0.6 Gy in irradiated tissue was observed. However, the V{sub 65} and V{sub 70} values for bladder and rectum were lower by 2.3{+-}1.5% and 2.4{+-}2.1% indicating better volume sparing at high doses with the optimized plans incorporating CB. For the head and neck case, identical target coverage was achieved, while a comparable sparing of the brain stem, optic chiasm, and optic nerves was observed. The technique of optimized planning incorporating doses from daily online MV-CBCT procedures provides an alternative method for imaging IMRT patients. It allows for daily treatment modifications where other volumetric tomographic imaging techniques may not be feasible and/or available and where accurate patient localization with a high degree of precision is required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A strategy to objectively evaluate the necessity of correcting detected target deviations in image guided radiotherapy

Image guided radiotherapy technologies are being increasingly utilized in the treatment of various cancers. These technologies have enhanced the ability to detect temporal and spatial deviations of the target volume relative to planned radiation beams. Correcting these detected deviations may, in principle, improve the accuracy of dose delivery to the target. However, in many situations, a clinical decision has to be made as to whether it is necessary to correct some of the deviations since the relevant dosimetric impact may or may not be significant, and the corresponding corrective action may be either impractical or time consuming. Ideally this decision should be based on objective and reproducible criteria rather than subjective judgment. In this study, a strategy is proposed for the objective evaluation of the necessity of deviation correction during the treatment verification process. At the treatment stage, without any alteration from the planned beams, the treatment beams should provide the desired dose coverage to the geometric volume identical to the planning target volume (PTV). Given this fact, the planned dose distribution and PTV geometry were used to compute the dose coverage and PTV enclosure of the clinical target volume (CTV) that was detected from imaging during the treatment setup verification. The spatial differences between the detected CTV and the planning CTV are essentially the target deviations. The extent of the PTV enclosure of the detected CTV as well as its dose coverage were used as criteria to evaluate the necessity of correcting any of the target deviations. This strategy, in principle, should be applicable to any type of target deviations, including both target deformable and positional changes and should be independent of how the deviations are detected. The proposed strategy was used on two clinical prostate cancer cases. In both cases, gold markers were implanted inside the prostate for the purpose of treatment setup verification and were used to determine potential target deviations. To derive the detected CTV geometry from the planning CTV based on the locations of the gold markers, the CTV was approximated with an elastic semirigid body model. The derived CTV geometry and shape were confirmed with CBCT imaging. The evaluation results and the related mathematical equations and computational algorithm are presented. It is concluded that the proposed strategy is potentially useful in establishing objective criteria for the necessity of correction of the target deviations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The use of directional interstitial sources to improve dosimetry in breast brachytherapy

The purposes of this study were to investigate the feasibility of improving dosimetry with temporary low-dose-rate (LDR) multicatheter breast implants using directional {sup 125}I (iodine) interstitial sources and to provide a comparison of a patient treatment plan to that achieved by conventional high-dose-rate (HDR) interstitial breast brachytherapy. A novel {sup 125}I source emitting radiation in a specified direction has been developed. The directional sources contain an internal radiation shield that greatly reduces the intensity of radiation in the shielded direction. The sources have a similar dose distribution to conventional nondirectional sources on the unshielded side. The treatment plan for a patient treated with HDR interstitial brachytherapy with {sup 192}Ir (iridium) was compared with a directional {sup 125}I treatment plan using the same data set. Several dosimetric parameters are compared including target volume coverage, volume receiving 50%, 100%, and 150% of the prescription dose (V50, V100, and V150, respectively), dose homogeneity index (DHI), and the skin surface areas receiving 30%, 50%, and 80% of the prescription dose (S30, S50, and S80, respectively). The HDR and LDR prescription doses were 34 Gy in ten fractions delivered over five days and 45 Gy in 108 h, respectively. Similar and excellent target volume coverage was achieved by both directional LDR and HDR plans (99.2% and 97.5%, respectively). For a 170 cm{sup 3} target volume, the dosimetric parameters were similar for LDR and HDR: DHI was 0.82 in both cases, V100 was 214.4 cm{sup 3} and 225.7 cm{sup 3}, and V150 was 39.1 cm{sup 3} and 40.4 cm{sup 3}, respectively. However, with directional LDR, significant reductions in skin dose were achieved: S30 was reduced from 100.6 to 62.5 cm{sup 2}, S50 from 50.6 to 16.1 cm{sup 2}, and S80 from 2 cm{sup 2} to zero. The reduction in V50 for the whole breast was more than 100 cm{sup 3} (386.1 cm{sup 3} for LDR versus 489.2 cm{sup 3} for HDR). In this case study, compared with HDR, directional interstitial LDR {sup 125}I sources allow similar dose coverage to the subcutaneous target volume while lowering the skin dose due to a more conformal dose distribution and quicker falloff beyond the target. The improved dose distribution provided by directional interstitial brachytherapy might enable partial breast treatment to tumors closer to the skin or chest wall or in relatively small breasts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-specific dose estimation for pediatric chest CT

Current methods for organ and effective dose estimations in pediatric CT are largely patient generic. Physical phantoms and computer models have only been developed for standard/limited patient sizes at discrete ages (e.g., 0, 1, 5, 10, 15 years old) and do not reflect the variability of patient anatomy and body habitus within the same size/age group. In this investigation, full-body computer models of seven pediatric patients in the same size/protocol group (weight: 11.9-18.2 kg) were created based on the patients' actual multi-detector array CT (MDCT) data. Organs and structures in the scan coverage were individually segmented. Other organs and structures were created by morphing existing adult models (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. Organ and effective dose of these patients from a chest MDCT scan protocol (64 slice LightSpeed VCT scanner, 120 kVp, 70 or 75 mA, 0.4 s gantry rotation period, pitch of 1.375, 20 mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated to simulate radiation transport in the same CT system. The seven patients had normalized effective dose of 3.7-5.3 mSv/100 mAs (coefficient of variation: 10.8%). Normalized lung dose and heart dose were 10.4-12.6 mGy/100 mAs and 11.2-13.3 mGy/100 mAs, respectively. Organ dose variations across the patients were generally small for large organs in the scan coverage (<7%), but large for small organs in the scan coverage (9%-18%) and for partially or indirectly exposed organs (11%-77%). Normalized effective dose correlated weakly with body weight (correlation coefficient: r=-0.80). Normalized lung dose and heart dose correlated strongly with mid-chest equivalent diameter (lung: r=-0.99, heart: r=-0.93); these strong correlation relationships can be used to estimate patient-specific organ dose for any other patient in the same size/protocol group who undergoes the chest scan. In summary, this work reported the first assessment of dose variations across pediatric CT patients in the same size/protocol group due to the variability of patient anatomy and body habitus and provided a previously unavailable method for patient-specific organ dose estimation, which will help in assessing patient risk and optimizing dose reduction strategies, including the development of scan protocols.

61 RADIATION PROTECTION AND DOSIMETRY↗

Planning tools for modulated electron radiotherapy

Purpose: To develop tools to plan modulated electron radiotherapy (MERT) and to compare the MERT plans to conventional or intensity modulated radiotherapy (IMRT) treatment plans. Methods: Monte Carlo dose calculations of electron fields shaped with the inherent photon multileaf collimators (MLCs) were investigated in this study. Treatment plans for four postmastectomy breast cancer patients were generated using MERT. The distances from the patient skin surfaces to the distal planning target volume surfaces were computed along the beam axis direction to determine the physical depth. Electron beam energies were selected to provide target coverage at these depths and energy bins were generated. A custom built MERT treatment planning graphical user interface (MERTgui) was used to shape the electron bins into deliverable electron segments. Monte Carlo dose distribution simulations were performed using the MLC-defined segments generated from the MERTgui. A custom built superposition gui was used to combine doses for each segment using relative weights and final MERT treatment plans were compared to the conventional or IMRT treatment plans. In addition, a demonstration of combined MERT and IMRT treatment plans was performed. Results: The MERT treatment plans provided acceptable target organ coverage in all cases. Relative to 3D conventional or IMRT treatment plans, the MERT plans predicted lower heart doses in all cases; average of the heart D{sub 20} of all plans was reduced from 14.1 to 3.3 Gy. The contralateral breast and contralateral lung doses decreased substantially with MERT planning compared to IMRT (on average, contralateral breast heart D{sub 20} was reduced from 8.7 to 0.7 Gy and contralateral lung D{sub 20} was reduced from 8.4 to 1.2 Gy with MERT). Ipsilateral lung D{sub 20} was lower with MERT than with the conventional plans (44.6 vs 29.2 Gy with MERT), but greater when compared against IMRT treatment plans (25.4 vs 28.9 Gy with MERT). A MERT and IMRT combination plan was generated to benefit from the complementary advantages of MERT and IMRT, resulting in satisfactory target coverage and reduced organ at risk doses. Conclusions: MERT tools can facilitate treatment planning and provide plans for treatment of shallow targets such as the postmastectomy chest wall.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of the dosimetric impact of interfractional anatomical variations on prostate proton therapy using daily in-room CT images

Purpose: To quantify interfractional anatomical variations and their dosimetric impact during the course of fractionated proton therapy (PT) of prostate cancer and to assess the robustness of the current treatment planning techniques. Methods: Simulation and daily in-room CT scans from ten prostate carcinoma patients were analyzed. PT treatment plans (78 Gy in 39 fractions of 2 Gy) were created on the simulation CT, delivering 25 fractions to PTV1 (expanded from prostate and seminal vesicles), followed by 14 boost fractions to PTV2 (expanded from prostate). Plans were subsequently applied to daily CT, with beams aligned to the prostate center in the sagittal plane. For five patients having a sufficiently large daily imaging volume, structure contours were manually drawn, and plans were evaluated for all CT sets. For the other five patients, the plans were evaluated for six selected fractions. The daily CT was matched to the simulation CT through deformable registration. The registration accuracy was validated for each fraction, and the three patients with a large number of accurately registered fractions were used for dose accumulation. Results: In individual fractions, the coverage of the prostate, seminal vesicles, and PTV1 was generally maintained at the corresponding prescription dose. For PTV2, the volume covered by the fractional prescription dose of 2 Gy (i.e., V2) was, on average, reduced by less than 3% compared to the simulation plan. Among the 225 (39 x 5 + 6 x 5) fractions examined, 15 showed a V2 reduction larger than 5%, of which ten were caused by a large variation in rectal gas, and five were due to a prostate shift in the craniocaudal direction. The fractional dose to the anterior rectal wall was found to increase for one patient who had large rectal gas volume in 25 of the 39 fractions, and another who experienced significant prostate volume reduction during the treatment. The fractional bladder dose generally increased with decreasing fullness. In the total accumulated dose for the three patients after excluding a few fractions with inaccurate registration due to a large amount of rectal gas (a condition inconsistent with RTOG protocol), 98.5%, 96.6%, and 98.2% of the PTV2 received the prescription dose of 78 Gy. The V75 and V70 of the anterior rectal wall and bladder both remained within tolerance. Conclusions: The results confirm that the PT planning techniques and dose constraints used at our institution ensure that target coverage to the prescription dose is maintained in the presence of interfractional anatomical variations. Dose coverage in individual fractions can be compromised, and normal tissue dose increased, due to deviations in the bladder and rectal volume compared to the simulation plans or progressive changes in the prostate volume during the treatment. Deviations from the plan can be reduced with efforts aimed at maintaining consistent daily patient anatomy.

61 RADIATION PROTECTION AND DOSIMETRY↗

High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array

Purpose: The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array, which generates all the projection images needed for tomosynthesis reconstruction by electronically activating individual x-ray sources without any mechanical motion. The stationary digital breast tomosynthesis (s-DBT) design aims to (i) increase the system spatial resolution by eliminating image blurring due to x-ray tube motion and (ii) reduce the scanning time. Low spatial resolution and long scanning time are the two main technical limitations of current DBT technology. Methods: A CNT x-ray source array was designed and evaluated against a set of targeted system performance parameters. Simulations were performed to determine the maximum anode heat load at the desired focal spot size and to design the electron focusing optics. Field emission current from CNT cathode was measured for an extended period of time to determine the stable life time of CNT cathode for an expected clinical operation scenario. The source array was manufactured, tested, and integrated with a Selenia scanner. An electronic control unit was developed to interface the source array with the detection system and to scan and regulate x-ray beams. The performance of the s-DBT system was evaluated using physical phantoms. Results: The spatially distributed CNT x-ray source array comprised 31 individually addressable x-ray sources covering a 30 angular span with 1 pitch and an isotropic focal spot size of 0.6 mm at full width at half-maximum. Stable operation at 28 kV(peak) anode voltage and 38 mA tube current was demonstrated with extended lifetime and good source-to-source consistency. For the standard imaging protocol of 15 views over 14, 100 mAs dose, and 2 x 2 detector binning, the projection resolution along the scanning direction increased from 4.0 cycles/mm [at 10% modulation-transfer-function (MTF)] in DBT to 5.1 cycles/mm in s-DBT at magnification factor of 1.08. The improvement is more pronounced for faster scanning speeds, wider angular coverage, and smaller detector pixel sizes. The scanning speed depends on the detector, the number of views, and the imaging dose. With 240 ms detector readout time, the s-DBT system scanning time is 6.3 s for a 15-view, 100 mAs scan regardless of the angular coverage. The scanning speed can be reduced to less than 4 s when detectors become faster. Initial phantom studies showed good quality reconstructed images. Conclusions: A prototype s-DBT scanner has been developed and evaluated by retrofitting the Selenia rotating gantry DBT scanner with a spatially distributed CNT x-ray source array. Preliminary results show that it improves system spatial resolution substantially by eliminating image blur due to x-ray focal spot motion. The scanner speed of s-DBT system is independent of angular coverage and can be increased with faster detector without image degration. The accelerated lifetime measurement demonstrated the long term stability of CNT x-ray source array with typical clinical operation lifetime over 3 years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of MLC leaf width on treatment adaptation and accuracy for concurrent irradiation of prostate and pelvic lymph nodes

Purpose: The aim of the study was to evaluate the impact of multileaf collimator (MLC) leaf width on treatment adaptation and delivery accuracy for concurrent treatment of the prostate and pelvic lymph nodes with intensity modulated radiation therapy (IMRT). Methods: Seventy-five kilovoltage cone beam CTs (KV-CBCT) from six patients were included for this retrospective study. For each patient, three different IMRT plans were created based on a planning CT using three different MLC leaf widths of 2.5, 5, and 10 mm, respectively. For each CBCT, the prostate displacement was determined by a dual image registration. Adaptive plans were created by shifting selected MLC leaf pairs to compensate for daily prostate movements. To evaluate the impact of MLC leaf width on the adaptive plan for each daily CBCT, three MLC shifted plans were created using three different leaf widths of MLCs (a total of 225 adaptive treatment plans). Selective dosimetric endpoints for the tumor volumes and organs at risk (OARs) were evaluated for these adaptive plans. Using the planning CT from a selected patient, MLC shifted plans for three hypothetical longitudinal shifts of 2, 4, and 8 mm were delivered on the three linear accelerators to test the deliverability of the shifted plans and to compare the dose accuracy of the shifted plans with the original IMRT plans. Results: Adaptive plans from 2.5 and 5 mm MLCs had inadequate dose coverage to the prostate (D99 < 97%, or D{sub mean} < 99% of the planned dose) in 6%-8% of the fractions, while adaptive plans from 10 mm MLC led to inadequate dose coverage to the prostate in 25.3% of the fractions. The average V{sub 56Gy} of the prostate over the six patients was improved by 6.4% (1.6%-32.7%) and 5.8% (1.5%-35.7%) with adaptive plans from 2.5 and 5 mm MLCs, respectively, when compared with adaptive plans from 10 mm MLC. Pelvic lymph nodes were well covered for all MLC adaptive plans, as small differences were observed for D99, D{sub mean}, and V{sub 50.4Gy}. Similar OAR sparing could be achieved for the bladder and rectum with all three MLCs for treatment adaptation. The MLC shifted plans can be accurately delivered on all three linear accelerators with accuracy similar to their original IMRT plans, where gamma (3%/3 mm) passing rates were 99.6%, 93.0%, and 92.1% for 2.5, 5, and 10 mm MLCs, respectively. The percentages of pixels with dose differences between the measurement and calculation being less than 3% of the maximum dose were 85.9%, 82.5%, and 70.5% for the original IMRT plans from the three MLCs, respectively. Conclusions: Dosimetric advantages associated with smaller MLC leaves were observed in terms of the coverage to the prostate, when the treatment was adapted to account for daily prostate movement for concurrent irradiation of the prostate and pelvic lymph nodes. The benefit of switching the MLC from 10 to 5 mm was significant (p Much-Less-Than 0.01); however, switching the MLC from 5 to 2.5 mm would not gain significant (p= 0.15) improvement. IMRT plans with smaller MLC leaf widths achieved more accurate dose delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental validation of the van Herk margin formula for lung radiation therapy

Purpose: To validate the van Herk margin formula for lung radiation therapy using realistic dose calculation algorithms and respiratory motion modeling. The robustness of the margin formula against variations in lesion size, peak-to-peak motion amplitude, tissue density, treatment technique, and plan conformity was assessed, along with the margin formula assumption of a homogeneous dose distribution with perfect plan conformity.Methods: 3DCRT and IMRT lung treatment plans were generated within the ORBIT treatment planning platform (RaySearch Laboratories, Sweden) on 4DCT datasets of virtual phantoms. Random and systematic respiratory motion induced errors were simulated using deformable registration and dose accumulation tools available within ORBIT for simulated cases of varying lesion sizes, peak-to-peak motion amplitudes, tissue densities, and plan conformities. A detailed comparison between the margin formula dose profile model, the planned dose profiles, and penumbra widths was also conducted to test the assumptions of the margin formula. Finally, a correction to account for imperfect plan conformity was tested as well as a novel application of the margin formula that accounts for the patient-specific motion trajectory.Results: The van Herk margin formula ensured full clinical target volume coverage for all 3DCRT and IMRT plans of all conformities with the exception of small lesions in soft tissue. No dosimetric trends with respect to plan technique or lesion size were observed for the systematic and random error simulations. However, accumulated plans showed that plan conformity decreased with increasing tumor motion amplitude. When comparing dose profiles assumed in the margin formula model to the treatment plans, discrepancies in the low dose regions were observed for the random and systematic error simulations. However, the margin formula respected, in all experiments, the 95% dose coverage required for planning target volume (PTV) margin derivation, as defined by the ICRU; thus, suitable PTV margins were estimated. The penumbra widths calculated in lung tissue for each plan were found to be very similar to the 6.4 mm value assumed by the margin formula model. The plan conformity correction yielded inconsistent results which were largely affected by image and dose grid resolution while the trajectory modified PTV plans yielded a dosimetric benefit over the standard internal target volumes approach with up to a 5% decrease in the V20 value.Conclusions: The margin formula showed to be robust against variations in tumor size and motion, treatment technique, plan conformity, as well as low tissue density. This was validated by maintaining coverage of all of the derived PTVs by 95% dose level, as required by the formal definition of the PTV. However, the assumption of perfect plan conformity in the margin formula derivation yields conservative margin estimation. Future modifications to the margin formula will require a correction for plan conformity. Plan conformity can also be improved by using the proposed trajectory modified PTV planning approach. This proves especially beneficial for tumors with a large anterior–posterior component of respiratory motion.

61 RADIATION PROTECTION AND DOSIMETRY↗

Three independent one-dimensional margins for single-fraction frameless stereotactic radiosurgery brain cases using CBCT

Purpose: Setting a proper margin is crucial for not only delivering the required radiation dose to a target volume, but also reducing the unnecessary radiation to the adjacent organs at risk. This study investigated the independent one-dimensional symmetric and asymmetric margins between the clinical target volume (CTV) and the planning target volume (PTV) for linac-based single-fraction frameless stereotactic radiosurgery (SRS).Methods: The authors assumed a Dirac delta function for the systematic error of a specific machine and a Gaussian function for the residual setup errors. Margin formulas were then derived in details to arrive at a suitable CTV-to-PTV margin for single-fraction frameless SRS. Such a margin ensured that the CTV would receive the prescribed dose in 95% of the patients. To validate our margin formalism, the authors retrospectively analyzed nine patients who were previously treated with noncoplanar conformal beams. Cone-beam computed tomography (CBCT) was used in the patient setup. The isocenter shifts between the CBCT and linac were measured for a Varian Trilogy linear accelerator for three months. For each plan, the authors shifted the isocenter of the plan in each direction by ±3 mm simultaneously to simulate the worst setup scenario. Subsequently, the asymptotic behavior of the CTV V{sub 80%} for each patient was studied as the setup error approached the CTV-PTV margin.Results: The authors found that the proper margin for single-fraction frameless SRS cases with brain cancer was about 3 mm for the machine investigated in this study. The isocenter shifts between the CBCT and the linac remained almost constant over a period of three months for this specific machine. This confirmed our assumption that the machine systematic error distribution could be approximated as a delta function. This definition is especially relevant to a single-fraction treatment. The prescribed dose coverage for all the patients investigated was 96.1%± 5.5% with an extreme 3-mm setup error in all three directions simultaneously. It was found that the effect of the setup error on dose coverage was tumor location dependent. It mostly affected the tumors located in the posterior part of the brain, resulting in a minimum coverage of approximately 72%. This was entirely due to the unique geometry of the posterior head.Conclusions: Margin expansion formulas were derived for single-fraction frameless SRS such that the CTV would receive the prescribed dose in 95% of the patients treated for brain cancer. The margins defined in this study are machine-specific and account for nonzero mean systematic error. The margin for single-fraction SRS for a group of machines was also derived in this paper.

61 RADIATION PROTECTION AND DOSIMETRY↗