Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Validation of the AMSU-B Bias Corrections Based on Satellite Measurements from SSM/T-2

The NOAA-15 Advanced Microwave Sounding Unit-B (AMSU-B) was designed in the same spirit as the Special Sensor Microwave Water Vapor Profiler (SSM/T-2) on board the DMSP F11-14 satellites, to perform remote sensing of spatial and temporal variations in mid and upper troposphere humidity. While the SSM/T-2 instruments have a 48 km spatial resolution at nadir and 28 beam positions per scan, AMSU-B provides an improvement with a 16 km spatial resolution at nadir and 90 beam positions per scan. The AMSU-B instrument, though, has been experiencing radio frequency interference (RFI) contamination from the NOAA-15 transmitters whose effect is dependent upon channel, geographic location, and current spacecraft antenna configuration. This has lead to large cross-track biases reaching as high as 100 Kelvin for channel 17 (150 GHz) and 50 Kelvin for channel 19 (183 +/-3 GHz). NOAA-NESDIS has recently provided a series of bias corrections for AMSU-B data starting from March, 1999. These corrections are available for each of the five channels, for every third field of view, and for three cycles within an eight second period. There is also a quality indicator in each data record to indicate whether or not the bias corrections should be applied. As a precursor to performing retrievals of mid and upper troposphere humidity, a validation study is performed by statistically analyzing the differences between the F14 SSM/T-2 and the bias corrected AMSU-B brightness temperatures for three months in the spring of 1999.

Kolodner, Marc A.↗

Total Dissolved Nitrogen and Ammonia Data for the East River Watershed, Colorado (2015-2025)

This data package contains mean values for total dissolved nitrogen (TDN) and ammonia concentrations for water samples taken from the East River Watershed in Colorado. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. TDN was analyzed using a Shimadzu Total Nitrogen Module (TNM-1) combined with the TOC-VCSH analyzer (Shimadzu Corporation, Japan). TNM-1 is a non-specific measurement of total nitrogen (TN). All nitrogen species in samples are combusted to nitrogen monoxide and nitrogen dioxide, then reacted with ozone to form an excited state of nitrogen dioxide. Upon returning to ground state, light energy is emitted. Then, TDN is measured using a chemiluminescence detector. Ammonia was determined using a Lachat's QuikChem 8500 Series 2 Flow Injection Analysis System (LACHAT Instruments, QuckChem 8500 series 2, Automated Ion Analyzer, Loveland, Colorado). When ammonia in water samples is heated (60 degrees C) with salicylate and hypochlorite in an alkaline phosphate buffer, an emerald green color is produced which is proportional to the ammonia concentration. The color is intensified by the addition of nitroprusside. Ethylenediaminetetraacetic acid (EDTA) is added to the buffer to prevent the interference of metal ions (Ca, Mg, and Fe etc.). Ammonia-N is then determined by LACHAT flow injection and a colorimetric assay at an absorbance wavelength 660 nm. (Reference: LACHAT Instruments: QuickChem Method 90-107-06-3-A, Determination of Ammonia by Flow Injection Analysis (High Throughput, Salicylate Method/DCIC) (Multi Matrix method). Written by Lynn Egan (Application group), February 08, 2011.) All files are labeled by location and variable, and data reported are the mean values upon replicate measurements. All samples were analyzed under a rigorous quality assurance and quality control (QA/QC) process as detailed in the methods. This data package contains (1) a zip file (tdn_ammonia_data_2015-2025.zip) containing a total of 299 files: 298 data files of ammonia and TDN data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v7_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v7_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the determination of Method Detection Limits (MDLs) for TDN data, which has been updated in 2026-08; and (5) PDF and docx files for the detemination of Method Detection Limits (MDLs) for Ammonia and the Interferences by LACHAT Flow Injection Analysis. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 105 locations containing TDN and Ammonia-N data. Update 2020-10-07: Updated the data files to remove times from the timestamps, so that only dates remain. The data values have not changed. Update 2021-04-11: Added Determination of Method Detection Limits (MDLs) for DIC, NPOC and TDN Analyses and Determination of Method Detection Limit for Ammonia and the Interferences by LACHAT Flow Injection Analysis documents, which can be accessed as PDFs or with Microsoft Word.Update on 6/10/2022: versioned updates to this dataset was made along with these changes: (1) updated total dissolved nitrogen and ammonia data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) restructure of units to comply with CSV reporting format requirements, (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2022-12-20: Updates were made to both the data files and reporting format specific files. Units were listed incorrectly, but have been fixed to reflect correct units (ug/L). File level metadata (flmd) and data dictionary (dd) files were updated to reflect the updated versions of these files. Available data was added up until 2022-06-01. Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-27. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Revised versions of the PDF and docx files for determination of MDLs for TDN were added to replace previous versions. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-10, of the PDF and docx files for determination of MDLs for TDN data were added to this dataset.

54 ENVIRONMENTAL SCIENCES↗

PLUSWIND Hourly Plant-Level Power

These data contain the hourly plant-level power time series from PLUSWIND. The time series is derived from the HRRR model and corrected for density and losses. The PLUSWIND dataset hosted on the Wind Data Hub here (https://a2e.energy.gov/project/pluswind) contains additional versions with meteorological corrections. Data are provided for years 2018 - 2021. The data hosted at this location include conversion from capacity factor output (normalized output) to total hourly production (units of MW).

17 WIND ENERGY↗

A Public Data Set of Auto-Generated Geotagged PV Site Equipment, Generated via Deep Learning

In this research, we present a data set over 100 photovoltaic (PV) sites in TX, which have been automatically geotagged via a fully autonomous deep learning (DL) pipeline. Specifically, locations of inverters, tracker/fixed tilt rows, batteries, and substations are labeled algorithmically. To ensure high data quality, all systems have been reviewed manually and any deep learning errors have been corrected. This public data set, as well as the open-sourced pipeline used to generate it, is valuable for site planning, modelling, and insurance purposes. Given time and resources, we hope to extend the data set to additional states/regions in the US.

14 SOLAR ENERGY↗

Data reduction, management, and analysis software for CID

In an overview of the Data Reduction System, three major steps are examined. First, the raw data tapes were selected from the onboard recorders. These tapes should provide the best quality data for the data reduction software system. These tapes contained 352 channels of data, plus the monitor channels recorded in 8 bit Pulsed Coded Modulation (PCM) words. The next step consists of transcribing the PCM tapes from 8 bit serial digital data to 8 bit parallel digital data. This puts the data in the correct format for processing. The transcription process was accomplished here at LaRC in the Central Data Transportation Facility (CDTF). The last step in this 3 step process is to process the data through the reduction system developed for the Impact Dynamic Research Facility in the early part of 1980. Processing system criteria, system interface routines, and engineering units program that reads digitized data from tapes, and file management programs are discussed.

Davis, C. W.↗

System for kick detection during a drilling operation

The disclosure provides a kick detection system for use during a drilling operation where wellbore kick warnings are provided based on indications of standoff conditions in a compensated instrument system. The system provides a warning of a potential kick condition by analyzing a current instrument compensation against a time series of past compensations, in order to monitor whether conditions within the standoff region of the wellbore are unexpectedly changing. The system comprises a source, a short-spaced detector, and a long-spaced detector, and a processor receives the short-spaced signal and the long-spaced signal, compensates the long-spaced signal, and generates standoff data reflecting the corrections applied to the long-range signal. The processor determines and maintains the standoff data as a time series and periodically compares a recent data point to a moving average in order to evaluate indications of a potential well kick.

Rose, Kelly K.↗

Joint Non-Parametric Correction Estimator for Excess Relative Risk Regression in Survival Analysis with Exposure Measurement Error

Summary Observational epidemiological studies often confront the problem of estimating exposure–disease relationships when the exposure is not measured exactly. We investigate exposure measurement error in excess relative risk regression, which is a widely used model in radiation exposure effect research. In the study cohort, a surrogate variable is available for the true unobserved exposure variable. The surrogate variable satisfies a generalized version of the classical additive measurement error model, but it may or may not have repeated measurements. In addition, an instrumental variable is available for individuals in a subset of the whole cohort. We develop a non-parametric correction estimator by using data from the subcohort and further propose a joint non-parametric correction estimator using all observed data to adjust for exposure measurement error. An optimal linear combination estimator of the joint non-parametric correction and non-parametric correction is further developed. The estimators proposed are non-parametric, which are consistent without imposing a covariate or error distribution, and are robust to heteroscedastic errors. Finite sample performance is examined via a simulation study. We apply the developed methods to data from the Radiation Effects Research Foundation, in which chromosome aberration is used to adjust for the effects of radiation dose measurement error on the estimation of radiation dose responses.

Wang, Ching-Yun↗

Structure Corrections in Modeling VLBI Delays for RDV Data

Since 1997, bimonthly S- and X-band observing sessions have been carried out employing the VLBA (Very Long Baseline Array) and as many as ten additional antennas. Maps of the extended structures have been generated for the 160 sources observed in ten of these experiments (approximately 200,000 observations) taking place during 1997 and 1998. This paper reports the results of the first massive application of such structure maps to correct the modeled VLBI (Very Long Baseline Interferometry) delay in astrometric data analysis. For high-accuracy celestial reference frame work, proper choice of a reference point within each extended source is crucial. Here the reference point is taken at the point of maximum emitted flux. Overall, the weighted delay residuals (approximately equal to 30 ps) are reduced by 8 ps in quadrature upon introducing source maps to model the structure delays of the sources. Residuals of some sources with extended or fast-varying structures improve by as much as 40 ps. Scatter of 'arc positions' about a time-linear model decreases substantially for most sources. Based on our results, it is also concluded that source structure is presently not the dominant error source in astrometric/geodetic VLBI.

Sovers, Ojars J.↗

Data Product: Ka ARM Zenith Radar (KAZR), in CfRadial format: moderate sensitivity mode, corrected

The KAZRCFRCOR Value Added Product (VAP) performs several corrections to the ingested KAZR data and also creates a significant detection mask for each radar mode. The VAP computes gaseous attenuation as a function of time and radial distance from the radar antenna, based on ambient relative humidity, and corrects observed reflectivities for that effect. KAZR reflectivities are also corrected in the antenna ‘nearfield’ range to compensate for the near-field antenna pattern and gain. KAZRCFRCOR also dealiases mean Doppler velocities, to correct velocities whose magnitudes exceed the radar’s Nyquist velocity. This dataset contains the 'kazrmd' (moderate sensitivity) mode output from this VAP.

54 ENVIRONMENTAL SCIENCES↗

Less-Complex Method of Classifying MPSK

An alternative to an optimal method of automated classification of signals modulated with M-ary phase-shift-keying (M-ary PSK or MPSK) has been derived. The alternative method is approximate, but it offers nearly optimal performance and entails much less complexity, which translates to much less computation time. Modulation classification is becoming increasingly important in radio-communication systems that utilize multiple data modulation schemes and include software-defined or software-controlled receivers. Such a receiver may "know" little a priori about an incoming signal but may be required to correctly classify its data rate, modulation type, and forward error-correction code before properly configuring itself to acquire and track the symbol timing, carrier frequency, and phase, and ultimately produce decoded bits. Modulation classification has long been an important component of military interception of initially unknown radio signals transmitted by adversaries. Modulation classification may also be useful for enabling cellular telephones to automatically recognize different signal types and configure themselves accordingly. The concept of modulation classification as outlined in the preceding paragraph is quite general. However, at the present early stage of development, and for the purpose of describing the present alternative method, the term "modulation classification" or simply "classification" signifies, more specifically, a distinction between M-ary and M'-ary PSK, where M and M' represent two different integer multiples of 2. Both the prior optimal method and the present alternative method require the acquisition of magnitude and phase values of a number (N) of consecutive baseband samples of the incoming signal + noise. The prior optimal method is based on a maximum- likelihood (ML) classification rule that requires a calculation of likelihood functions for the M and M' hypotheses: Each likelihood function is an integral, over a full cycle of carrier phase, of a complicated sum of functions of the baseband sample values, the carrier phase, the carrier-signal and noise magnitudes, and M or M'. Then the likelihood ratio, defined as the ratio between the likelihood functions, is computed, leading to the choice of whichever hypothesis - M or M'- is more likely. In the alternative method, the integral in each likelihood function is approximated by a sum over values of the integrand sampled at a number, 1, of equally spaced values of carrier phase. Used in this way, 1 is a parameter that can be adjusted to trade computational complexity against the probability of misclassification. In the limit as 1 approaches infinity, one obtains the integral form of the likelihood function and thus recovers the ML classification. The present approximate method has been tested in comparison with the ML method by means of computational simulations. The results of the simulations have shown that the performance (as quantified by probability of misclassification) of the approximate method is nearly indistinguishable from that of the ML method (see figure).

Hamkins, Jon↗

LANDSAT data preprocessing

The effect on LANDSAT data of a Sun angle correction, an intersatellite LANDSAT-2 and LANDSAT-3 data range adjustment, and the atmospheric correction algorithm was evaluated. Fourteen 1978 crop year LACIE sites were used as the site data set. The preprocessing techniques were applied to multispectral scanner channel data and transformed data were plotted and used to analyze the effectiveness of the preprocessing techniques. Ratio transformations effectively reduce the need for preprocessing techniques to be applied directly to the data. Subtractive transformations are more sensitive to Sun angle and atmospheric corrections than ratios. Preprocessing techniques, other than those applied at the Goddard Space Flight Center, should only be applied as an option of the user. While performed on LANDSAT data the study results are also applicable to meteorological satellite data.

Austin, W. W.↗

Clinical introduction of image lag correction for a cone beam CT system

Purpose: Image lag in the flat-panel detector used for Linac integrated cone beam computed tomography (CBCT) has a degrading effect on CBCT image quality. The most prominent visible artifact is the presence of bright semicircular structure in the transverse view of the scans, known also as radar artifact. Several correction strategies have been proposed, but until now the clinical introduction of such corrections remains unreported. In November 2013, the authors have clinically implemented a previously proposed image lag correction on all of their machines at their main site in Amsterdam. The purpose of this study was to retrospectively evaluate the effect of the correction on the quality of CBCT images and evaluate the required calibration frequency. Methods: Image lag was measured in five clinical CBCT systems (Elekta Synergy 4.6) using an in-house developed beam interrupting device that stops the x-ray beam midway through the data acquisition of an unattenuated beam for calibration. A triple exponential falling edge response was fitted to the measured data and used to correct image lag from projection images with an infinite response. This filter, including an extrapolation for saturated pixels, was incorporated in the authors’ in-house developed clinical CBCT reconstruction software. To investigate the short-term stability of the lag and associated parameters, a series of five image lag measurement over a period of three months was performed. For quantitative analysis, the authors have retrospectively selected ten patients treated in the pelvic region. The apparent contrast was quantified in polar coordinates for scans reconstructed using the parameters obtained from different dates with and without saturation handling. Results: Visually, the radar artifact was minimal in scans reconstructed using image lag correction especially when saturation handling was used. In patient imaging, there was a significant reduction of the apparent contrast from 43 ± 16.7 to 15.5 ± 11.9 HU without the saturation handling and to 9.6 ± 12.1 HU with the saturation handling, depending on the date of the calibration. The image lag correction parameters were stable over a period of 3 months. The computational load was increased by approximately 10%, not endangering the fast in-line reconstruction. Conclusions: The lag correction was successfully implemented clinically and removed most image lag artifacts thus improving the image quality. Image lag correction parameters were stable for 3 months indicating low frequency of calibration requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electron beam recorder image correction for ERTS

Video data from the Earth Resources Technology Satellite (ERTS) are entered into the initial image generation system and placed on film using an electron beam to correct for both radiometric and geometric errors, a hardware unit called EBRIC was designed, fabricated, and incorporated in the image processing system. It operates under the control of a process control computer, as it varies video signal and the x and y deflection signals of the EBR.

Heffner, P.↗

Precise terrestrial time: A means for improved ballistic missile guidance analysis

An approach developed to improve the ground instrumentation time tagging accuracy and adapted to support the Minuteman ICBM program is desired. The Timing Insertion Unit (TIU) technique produces a telemetry data time tagging resolution of one tenth of a microsecond, with a relative intersite accuracy after corrections and velocity data (range, azimuth, elevation and range rate) also used in missile guidance system analysis can be correlated to within ten microseconds of the telemetry guidance data. This requires precise timing synchronization between the metric and telemetry instrumentation sites. The timing synchronization can be achieved by using the radar automatic phasing system time correlation methods. Other time correlation techniques such as Television (TV) Line-10 and the Geostationary Operational Environmental Satellites (GEOS) terrestial timing receivers are also considered.

Ehrsam, E. E.↗

Radiometric performance of the Voyager cameras

The Voyager Imaging Experiment provided high-quality data of Jupiter and the Galilean satellites with the two flyby trajectories in March and July of 1979. Moderately accurate radiometric measurements have been made using these data. This paper evaluates the radiometric results and describes the inflight and ground geometric and radiometric correction factors. The radiometric quantities of intensity I and geometric albedo I/F are derived, and scaling factors for each of the filters are tabulated for correcting the 'calibrated' data from the Image Processing Laboratory at JPL. In addition, the key characteristics of both Voyager I and Voyager 2 cameras are tabulated.

Danielson, G. E.↗

Testing of 3-D models in 2-D adaptive wall test sections

Considerable effort was devoted to the development of two-dimensional adaptive wall test sections. The development of fully three-dimensional test sections, however, has not had this same level of effort expended. The limitations on three-dimensional research are the result of the complexity of both the mechanical design and operational aspects. Typical of the mechanical complexities are lack of readily available model and flow visualization access, and problems of sealing between adjacent walls for multi-wall types of test sections. The operational aspects are complicated by the necessity for many measurements of the boundary conditions which can be very time consuming. In three-dimensional testing, it is impossible to remove all of the boundary interference. It will be necessary, therefore, to apply residual corrections to the data. The more complex the test section shape, the more complex the calculation of the residual corrections becomes. From both the viewpoint of test section complexity and of ease of residual corrections, a simplified test section geometry is desirable. To aid in the design of simplified test sections, several researchers investigated the capability of using two-dimensional adaptive wall test sections to perform three-dimensional testing. By use of this type of design, the inherent complications and limitations of the fully three-dimensional design are avoided. Strategies of adaptation used for this application are described, as well as, sample results and a discussion of some limitations of the technique.

Wedemeyer, Erich H.↗

Evolution of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) flight and ground data processing system

The modifications made to both the AVIRIS instrument and the data processing facility since the instrument made its initial flight in the summer of 1987 are described. Historical development of the data system is discussed and attention is given to enhancements to instrument stability and noise performance. AVIRIS data facility objectives include rapid and automated decommutation and archiving of data, the ability to assess the quality of the data and health of the instrument, and the provision of an automated procedure for applying radiometric corrections to the data and providing responsive processing of data requests from investigators. The modifications described have resulted in an overall radiometric stability of better than 10 percent, with stability of only a few percent during a single flight.

Porter, Wallace M.↗

Validation of SO2 Retrievals from the Ozone Monitoring Instrument over NE China

The Dutch-Finnish Ozone Monitoring Instrument (OMI) launched on the NASA Aura satellite in July 2004 offers unprecedented spatial resolution, coupled with contiguous daily global coverage, for space-based UV measurements of sulfur dioxide (SO2). We present a first validation of the OMI SO2 data with in situ aircraft measurements in NE China in April 2005. The study demonstrates that OMI can distinguish between background SO2 conditions and heavy pollution on a daily basis. The noise (expressed as the standard deviation,sigma) is approximately 1.5 DU (Dobson units; 1 DU = 2.69 10 (exp 16) molecules/cm (exp 2)) for instantaneous field of view boundary layer (PBL) SO2 data. Temporal and spatial averaging can reduce the noise to sigma approximetly 0.3 DU over a remote region of the South Pacific; the long-term average over this remote location was within 0.1 DU of zero. Under polluted conditions collection 2 OMI data are higher than aircraft measurements by a factor of two. Improved calibrations of the radiance and irradiance data (collection 3) result in better agreement with aircraft measurements on polluted days. The air mass corrected collection 3 data still show positive bias and sensitivity to UV absorbing aerosols. The difference between the in situ data and the OMI SO2 measurements within 30 km of the aircraft profiles was about 1 DU, equivalent to approximately 5 ppb from 0 to 3000 m altitude. Quantifying the SO2 and aerosol profiles and spectral dependence of aerosol absorption between 310 and 330 nm are critical for an accurate estimate of SO2 from satellite UV measurements.

Krotkov, Nickolay A.↗