Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Spatially resolved gas and stellar kinematics in compact starburst galaxies

The kinematics of galaxies provide valuable insights into their physics and assembly history. Kinematics are governed not only by the gravitational potential, but also by merger events and stellar feedback processes such as stellar winds and supernova explosions. We aim to identify what governs the kinematics in a sample of SDSS-selected nearby starburst galaxies, by obtaining spatially resolved measurements of the gas and stellar kinematics. We obtained near-infrared integral-field K-band spectroscopy with VLT/SINFONI for 15 compact starburst galaxies. We derived the integrated as well as spatially resolved stellar and gas kinematics. The stellar kinematics were derived from the CO absorption bands, and Paα and Brγ emission lines were used for the gas kinematics. Based on the integrated spectra, we find that the majority of galaxies have gas and stellar velocity dispersion that are comparable. A spatially resolved comparison shows that the six galaxies that deviate show evidence for a bulge or stellar feedback. Two galaxies are identified as mergers based on their double-peaked emission lines. In our sample, we find a negative correlation between the ratio of the rotational velocity over the velocity dispersion (v rot /σ) and the star formation rate surface density. We propose a scenario where the global kinematics of the galaxies are determined by gravitational instabilities that affect both the stars and gas. This process could be driven by mergers or accretion events. Effects of stellar feedback on the ionised gas are more localised and detected only in the spatially resolved analysis. The mass derived from the velocity dispersion provides a reliable mass even if the galaxy cannot be spatially resolved. The technique used in this paper is applicable to galaxies at low and high redshift with the next generation of infrared-focussed telescopes (JWST and ELT).

79 ASTRONOMY AND ASTROPHYSICS↗

The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control and Safety Systems during the Second Long Shutdown of the Large Hadron Collider at CERN

The Electromagnetic Calorimeter (ECAL) is one of the subdetectors of the Compact Muon Solenoid (CMS), a general-purpose particle detector at the CERN Large Hadron Collider (LHC). The CMS ECAL Detector Control System (DCS) and the CMS ECAL Safety System (ESS) have supported the detector operations and ensured the detector’s integrity since the CMS commissioning phase, more than 10 years ago. Over this long period, several changes to both systems were necessary to correct issues, extend functionality and keep them in-line with current hardware technologies and the evolution of software platforms. Due to the constraints imposed on significant changes to a running system, major hardware and software upgrades were therefore deferred to the second LHC Long Shutdown (LS2). This paper presents the architectures of the CMS ECAL control and safety systems, discusses the ongoing and planned upgrades, details implementation processes and validation methods and highlights the expectations for the post-LS2 systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact ExB mass separator for heavy ion beams

A compact ExB mass separator that deflects beam by 30 deg. has been designed and built to prove its principle of operation. The main part of the separator is contained in a shielding box of 11 cm long, 9 cm wide, and 1.5 cm high. An electromagnet of 7 cm pole diameter produced variable magnetic field in the mass separation region instead of a couple of permanent magnets which is to be used in the final design. The experimental result agreed well with the theoretical prediction, and larger mass ions is bent with less magnetic field with the aid of the deflection electric field. The reduction in resolving power for mass separation due to the deflection electric field has been investigated experimentally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics of a He{sup +} beam extracted from a compact magnetic bucket-type ion source

Performance of a compact He{sup +} ion source was investigated before installing it to the experiment system developed for studying the efficiency of autodetachment neutralization from He{sup -} to He{sup 0}. Dependence of the extracted ion current upon the plasma parameters and that upon the extraction voltage indicated that the source performance was limited by space charge effect. The beam emittance was measured with a multislit system for various operation conditions. The experimentally determined emittance agreed well with the emittance obtained from ion trajectories calculated with input plasma parameters measured by a Langmuir probe. The beam current density of 60 mA/cm{sup 2} and the emittance of less than 25{pi} mm mrad are expected to deliver enough current to the downstream of the He{sup -} neutralizer system to clarify factors affecting the final He{sup 0} intensity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gluon Vortices and Induced Magnetic Field in Compact Stars

The natural candidates for the realization of color superconductivity are the extremely dense cores of compact stars, many of which have very large magnetic fields, especially the so called magnetars. In this paper we discuss how a color superconducting core can serve to generate and enhance the stellar magnetic field without appealing to a magnetohydrodynamic dynamo mechanism.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compact cantilever force probe for plasma pressure measurements

A simple, compact cantilever force probe (CFP) has been developed for plasma pressure measurements. It is based on the pull-in phenomenon well known in microelectromechanical-system electrostatic actuators. The probe consists of a thin (25 {mu}m) titanium foil cantilever (38 mm of length and 14 mm of width) and a fixed electrode separated by a 0.75 mm gap. The probe is shielded by brass box and enclosed into boron nitride housing with a 9 mm diameter window for exposing part of cantilever surface to the plasma. When the voltage is applied between the cantilever and the electrode, an attractive electrostatic force is counterbalanced by cantilever restoring spring force. At some threshold (pull-in) voltage the system becomes unstable and the cantilever abruptly pulls toward the fixed electrode until breakdown occurs between them. The threshold voltage is sensitive to an additional externally applied force, while a simple detection of breakdown occurrence can be used to measure that threshold voltage value. The sensitivity to externally applied forces obtained during calibration is 0.28 V/{mu}N (17.8 V/Pa for pressure). However, the resolution of the measurements is {+-}0.014 mN ({+-}0.22 Pa) due to the statistical scattering in measured pull-in voltages. The diagnostic temporal resolution is {approx}10 ms, being determined by the dynamics of pull-in process. The probe has been tested in the tokamak ISTTOK edge plasma, and a plasma force of {approx}0.07 mN (plasma pressure {approx}1.1 Pa) has been obtained near the leading edge of the limiter. This value is in a reasonable agreement with the estimations using local plasma parameters measured by electrical probes. The use of the described CFP is limited by a heat flux of Q{approx}10{sup 6} W/m{sup 2} due to uncontrollable rise of the cantilever temperature ({delta}T{approx}20 deg. C) during CFP response time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of compact electron cyclotron resonance ion source

The compact electron cyclotron resonance (ECR) ion source with a permanent magnet configuration (Kei2 source) has been developed at National Institute of Radiological Sciences for a new carbon therapy facility. The Kei2 source was designed for production of C{sup 4+} ions; its performance such as beam intensity and stability has already reached the medical requirements. Therefore, the prototype development of the source for medical use is essentially finished. Recently, we have started a few studies on other applications of the source. One is the production of fullerenes in the ECR plasma and modified fullerenes with various atoms for new materials. A second application is the production of multiply charged ions (not only carbon) for ion implantation. In this paper, some basic experiments for these applications are reported.

36 MATERIALS SCIENCE↗

Compact 2.45 GHz microwave ion/atom source

Characteristics of a microwave driven 3.4 cm diameter compact ion/atom source equipped with permanent magnets were tested. The source can be mounted to a standard copper gasket flange, and microwave power is supplied through an N-type microwave connector. The ion source plasma was observed through an ion extraction hole with an optical emission spectrometer. Peak height of an optical line spectrum emission corresponding to atomic nitrogen increased in proportion to the microwave input power. Quadrupole mass spectrometer showed that N{sup +} and N{sub 2}{sup +} were the dominant species in the extracted ion beam. Nitrogen ion current density of 0.23 mA/cm{sup 2} was obtained with only 10 W discharge power and 6x10{sup -3} Pa source surrounding pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact soft x-ray spectrometer for plasma diagnostics at the Heidelberg Electron Beam Ion Trap

A compact flat-field soft x-ray grazing-incidence grating spectrometer equipped with a cryogenically cooled back-illuminated charge-coupled device camera was built and implemented at the Heidelberg Electron Beam Ion Trap. The instrument spans the spectral region from 1 to 37 nm using two different gratings. In slitless operation mode, it directly images a radiation source, in this case ions confined in an electron beam ion trap, with high efficiency and reaching hereby a resolving power of {lambda}/{delta}{lambda} congruent with 130 at 2 nm and of {lambda}/{delta}{lambda} congruent with 600 at 28 nm. Capable of automatized operation, its low noise and excellent stability make it an ideal instrument not only for spectroscopic diagnostics requiring wide spectral coverage but also for precision wavelength measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VELOCE: A compact pulser for dynamic material characterization and hypervelocity impact of flyer plates

Sharing similarities with the GEPI pulser which is dedicated to Isentropic Compression Experiments (ICE), VELOCE, an even more compact electrical pulser, has been designed and built in duplicate for SNL and WSU. This type of machine complements gun and laser facilities in the study of material response. In order to achieve a broad loading capability and fast turn around, the design is built around a solid dielectric transmission line to couple current from low inductance capacitors and electrically triggered switches. Peaking capacitors enhanced by a low inductance, multi-channel sharpening switch reduce the quarter period of the pulser to about 470 ns (0-100%). Gas mixtures in the switch cavity and inductances in parallel allow modification of the shape of the induced pressure wave. At 80 kV of charge voltage, the peak current can reach 3.5 MA. Design of the pulser, range of pressures and velocities, as well as potential applications are presented. A consistent numerical tool developed for pulsers design based on a circuit code coupled to a 1D MHD code is also introduced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of magnetic configuration effects on plasma boundary and measurement of edge electron density in the spherical tokamak compact plasma wall interaction experimental device using Li sheet beam

Two-dimensional lithium beam imaging technique has been applied in the spherical tokamak CPD (compact plasma wall interaction experimental device) to study the effects of magnetic field configurations on rf plasma boundary in the absence of any plasma current, and also for the measurement of a two-dimensional edge electron density profile. With the present working condition of the diagnostics, the minimum measured electron density can be {approx}1.0x10{sup 16} m{sup -3}; this is considered to be the definition for the plasma boundary. The performance of the lithium sheet beam is absolutely calibrated using a quartz crystal monitor. Experimental results reveal that magnetic field configuration, either mirror or so-called null, critically affects the rf plasma boundary. A sharp lower boundary is found to exist in magnetic null configuration, which is quite different from that in the weak mirror configuration. Theoretical calculations of particle drift orbit and magnetic connection length (wall-to-wall) suggest that only mirror trapped particles are confined within a region where the magnetic connection length is {approx}4.0 m or more. A two-dimensional edge electron density profile is obtained from the observed Li I intensity profile. Overdense plasma formation is discussed from the viewpoint of mode conversion of rf wave into electron Bernstein wave and its dependence on the electron density profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strange Stars : An interesting member of the compact object family

We have studied strange star properties both at zero temperature and at finite temperatures and searched signatures of strange stars in gamma-ray, x-ray and radio astronomy. We have a set of Equations of State (EoS) for strange quark matter (SQM) and solving the TOV equations, we get the structure of strange stars. The maximum mass for a strange star decreases with the increase of temperature, because at high temperatures, the EoS become softer. One important aspect of strange star is that, surface tension depends on the size and structure of the star and is significantly larger than the conventional values. Moment of inertia is another important parameter for compact stars as by comparing theoretical values with observed estimate, it is possible to constrain the dense matter Equation of State. We hope that this approach will help us to decide whether the members of the double pulsar system PSR J0737-3039 are neutron stars or strange stars.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Novel design of a compact 'cylindrical mirror analyzer' array

The design of a compact multiangle electron analyzer array for simultaneous detection of scattered and ejected electrons at nine different angles is described. It consists of eight slim 'simulated' cylindrical mirror analyzers (CMAs) providing electron detection for scattering/ejected angles of 14 deg. apart from each other. A ninth analyzer is arranged to a scattering angle on the opposite side. A single analyzer has cylindrical symmetry equipotential lines in the region of the beam trajectories, whereas its electrodes are noncylindrical, except for the inner cylinder. The new spectrometer is easy to build because only a few electrodes of simple shape are needed for each of the analyzers. The electron optical properties of the new device are very close to those of a true CMA. Its geometric width, however, is only less than one-fifth of that of a conventional CMA, which allows one to arrange several analyzers close to each other. Example results with the new device are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental studies of zonal flow and field in compact helical system plasma

The experimental studies on zonal flows and turbulence have been carried out in Compact Helical System [K. Matsuoka, S. Kubo, M. Hosokawa et al., in Plasma Physics and Controlled Nuclear Fusion Research, Proc. 12th Int. Conf., Nice, 1988 (International Atomic Energy Agency, Vienna, 1989, Vol. 2, p. 411] using twin heavy ion beam probes. The paper presents the experimental observations of stationary zonal flow, nonlinear couplings between zonal flow and turbulence, and the role of zonal flow in the improved confinement, together with the recent discovery of zonal magnetic field. The presented experimental results strongly support the new paradigm that the plasma transport should be considered as a system of drift wave and zonal flows, and provides the first direct evidence for turbulence dynamo that the structured magnetic field can be really generated by turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Double planar wire array as a compact plasma radiation source

Magnetically compressed plasmas initiated by a double planar wire array (DPWA) are efficient radiation sources. The two rows in a DPWA implode independently and then merge together at stagnation producing soft x-ray yields and powers of up to 11.5 kJ/cm and more than 0.4 TW/cm, higher than other planar arrays or low wire-number cylindrical arrays on the 1 MA Zebra generator. DPWA, where precursors form in two stages, produce a shaped radiation pulse and radiate more energy in the main burst than estimates of implosion kinetic energy. High radiation efficiency, compact size (as small as 3-5 mm wide), and pulse shaping show that the DPWA is a potential candidate for ICF and radiation physics research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-line phase-contrast imaging of a biological specimen using a compact laser-Compton scattering-based x-ray source

Laser-Compton scattering (LCS) x-ray sources have recently attracted much attention for their potential use at local medical facilities because they can produce ultrashort pulsed, high-brilliance, and quasimonochromatic hard x rays with a small source size. The feasibility of in-line phase-contrast imaging for a 'thick' biological specimens of rat lumbar vertebrae using the developed compact LCS-X in AIST was investigated for the promotion of clinical imaging. In the higher-quality images, anatomical details of the spinous processes of the vertebrae are more clearly observable than with conventional absorption radiography. The results demonstrate that phase-contrast radiography can be performed using LCS-X.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact high-speed high-sensitivity second-harmonic interferometer for electron density measurement

A second-harmonic interferometer based on a CW Nd:YAG laser is presented. The device is extremely compact and versatile and is developed for line-integrated electron density measurements in large plasma machines. A sensitivity in measuring line-integrated electron density of 4x10{sup 13} cm{sup -2} with time resolution of 8 {mu}s, and 10{sup 13} cm{sup -2} with time resolution of 50 {mu}s, is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The use of a macroscopic formulation describing the effects of dynamic compaction and porosity on plasma sprayed copper

Coatings processed by thermal deposition techniques involve porosity. The Laser adhesion test developed for testing bond strength of a coating on its substrate requires a good knowledge of shock wave propagation in such media. Experiments carried out on plasma sprayed copper samples, about 14% porous, with velocity interferometer system for any reflector measurements display the discrepancy of previously used models. Hence, a one-dimensional formulation of the compaction process, based on a simple P-{alpha} model, is proposed to improve the correlation between experimental and computed data signals obtained on a plasma sprayed copper under dynamic loading. Besides, this improvement allows the estimation of the bond strength of a plasma sprayed copper on aluminum substrate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗