Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Analytical workflow dependence of experimental observables for uranium chemistries

In this work, we investigated how the sequencing of laboratory analytical methods used for chemical and morphological characterization influences analytical findings for particulate materials relevant to the nuclear fuel cycle, including UO2, U3O8, studtite (UO2O2·4H2O), and β-UO3, in the context of nuclear forensic analysis. Particles of each chemistry obtained from consistent production batches were exposed to Raman spectroscopy and scanning electron microscopy in varying orders to elucidate how the order in which the techniques are applied influences morphological and chemical observations as a function of particle size. The results indicate that particles from all four chemistries exposed to high-resolution electron imaging before Raman spectral analysis demonstrate optical vibrational spectral changes that reduce accurate interpretation of the underlying chemistry via Raman spectral analysis. We hypothesize that these changes are due to the thermal load of the electron beam imparted to the sample being unable to be dissipated by materials with poor thermal conduction properties. Results from this study will aid in determining best practices for forensic analysis procedures to reduce uncertainty in chemical determination of unknown particulate samples.

Manns, Rebecca [University of Nevada, Las Vegas]↗

A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors

Cluster counting $(dN/dx)$ is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good $π/K$ separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable $dN/dx$ measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/$\sqrt{\textrm{Hz}}$ , surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the $dN/dx$ method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC 4 H 10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.

Drift tube detector↗

Application of motional Stark effect in situ background correction to a superconducting tokamak

A polychrometer-type motional Stark effect (MSE) diagnostic technique, originally developed for the Alcator C-Mod tokamak, has been extended and applied to the Korea Superconducting Advanced Tokamak Research (KSTAR) device, the long-pulse superconducting tokamak, for the first time. It demonstrates a successful in situ subtraction of the polarized reflections off the vacuum vessel wall, sometimes up to half the total signal in some sightlines. To avoid the secondary neutral beam emission that may contaminate conventional beam-into-gas calibrations, a new approach, where the beam-into-gas measurements are made at various torus pressures with fixed vacuum fields, has been devised, which is possible with the stable superconducting coil systems of KSTAR. The validity of this new calibration scheme has been checked via plasma jog experiments. The experimental evidence of the polarized background light and the necessity of its correction in the MSE measurements made in KSTAR are presented as well.

47 OTHER INSTRUMENTATION↗

Advancing Cross-Sectional Scanning Electron Microscopy of Perovskite Solar Cells

Organic–inorganic perovskites are an emerging class of photovoltaic materials. Despite achieving power conversion efficiencies surpassing 26%, the challenge of perovskite stability including degradation during exposure to operational conditions such as light, heat, humidity, water, oxygen, and electric fields is well known. Related, perovskite instability has limited high-resolution electron imaging and characterization techniques that can be used for understanding degradation mechanisms. Furthermore, we demonstrate perovskite device cross-section preparation using mechanical polishing in a water-free environment with cryogenic Ar ion milling. Scanning electron microscopy was then used in both backscattered electron and secondary electron imaging modes to obtain information about layer structure, grain aggregate structure, and compositional heterogeneity. Monte Carlo CASINO simulations inform optimum beam conditions and image acquisition parameters and the effects of accelerating voltage, dwell times, and frame averaging for practical image acquisition are reported.

14 SOLAR ENERGY↗

In-Situ Synchrotron X-Ray Diffraction of Ultrasonic Microstructural Refinement During Solidification in a Commercial Al–Si–Mg Alloy

This study reports the first use of in-situ synchrotron X-ray diffraction (SXRD) to study the effects of ultrasonic melt processing (USMP) on phase and grain size evolution during solidification in a commercial Al–Si–Mg casting alloy. USMP is a technique that, when applied to aluminum as it solidifies, can be used to refine the local microstructure of large-scale castings. Analysis of the in-situ SXRD data to estimate the average grain size of primary α-Al grains during USMP demonstrates that USMP slows the growth rate of α-Al grains and reduces grain size by 36 pct. Furthermore, there is also evidence that USMP causes the primary α-Al grains to move relative to the X-ray beam; such motion increases the probability of primary α-Al grains colliding and fragmenting. This movement becomes constrained at the onset of the Al–Si binary eutectic, suggesting that USMP ceases to effectively refine the microstructure once the Al–Si binary eutectic begins to form. Complementary laboratory-scale X-ray diffraction (XRD) data were used to correlate the lattice parameters of the α-Al and Si (D-A4) phases with temperature to estimate cooling rate during solidification. Thus, this study can guide the design of novel castings with spatially distributed fine-grained regions produced using local ultrasonic processing.

Aluminum Alloys↗

Flying focus with arbitrary directionality for spatiotemporal control of laser intensity

Flying focus techniques produce laser pulses whose focal points travel at arbitrary, controllable velocities. While this flexibility can enhance a broad range of laser-based applications, existing techniques constrain the motion of the focal point to the propagation direction of the pulse. Here, we introduce a flying focus configuration that decouples the motion of the focus from the propagation direction. Here, a chirped laser pulse focused and diffracted by a diffractive lens and grating creates a focal point that can move both along and transverse to the propagation direction. The focal length of the lens, grating period, and chirp can be tuned to control the direction and velocity of the focus. Simulations demonstrate this control for a holographic configuration suited to high-power pulses, in which two off-axis pump beams with different focal lengths encode the equivalent phase of a chromatic lens and grating in a gas or plasma. For low-power pulses, conventional solid-state or adaptive optics can be used instead. Multi-dimensional control over the focal trajectory enables new configurations for applications, including laser wakefield acceleration of ions, nonlinear Thomson scattering, and surface-plasmon emission of THz radiation.

Classical optics↗

Proton Therapy for Breast Cancer: A Consensus Statement From the Particle Therapy Cooperative Group Breast Cancer Subcommittee

Radiation therapy plays an important role in the multidisciplinary management of breast cancer. Recent years have seen improvements in breast cancer survival and a greater appreciation of potential long-term morbidity associated with the dose and volume of irradiated organs. Proton therapy reduces the dose to nontarget structures while optimizing target coverage. However, there remain additional financial costs associated with proton therapy, despite reductions over time, and studies have yet to demonstrate that protons improve upon the treatment outcomes achieved with photon radiation therapy. There remains considerable heterogeneity in proton patient selection and techniques, and the rapid technological advances in the field have the potential to affect evidence evaluation, given the long latency period for breast cancer radiation therapy recurrence and late effects. In this consensus statement, we assess the data available to the radiation oncology community of proton therapy for breast cancer, provide expert consensus recommendations on indications and technique, and highlight ongoing trials’ cost-effectiveness analyses and key areas for future research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High spatial resolution and contrast radiography of hydrodynamic instabilities at the National Ignition Facility

In this work, we are developing techniques for studying the Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high-energy-densities at the National Ignition Facility (NIF). In particular, through the improvement of experimental imaging quality, we are progressing toward the study of the turbulent regime of the mixing regions in capsule implosion experiments for inertial confinement fusion, which requires few micrometers resolution. Using 60 NIF beams, a solid shock tube is driven launching a shock wave that crosses the interface between a dense and a light material pre-machined in the target to obtain sinusoidal ripples, which results in RM and RT instabilities that are imaged using the NIF Crystal Backlighter Imager. High-quality images were obtained with a mean resolution of 7 μm and improved contrast. While the obtained resolution does not allow the observation of the smallest scale of the “turbulent” energy spectrum, the generated image encompasses 63% of the total flow energy, a 50% improvement over previous studies, which is observed for the first time a roll-up feature in a high energy density-type RT experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mapping the frontiers of the nuclear mass surface

Nuclear masses play a central role in nuclear astrophysics, significantly impacting the origin of the elements and observables used to constrain ultradense matter. A variety of techniques are available to meet this need, varying in their emphasis on precision and reach from stability. Here I briefly summarize the status of and near-future for the time-of-flight magnetic-rigidity (TOF-Bρ) mass measurement technique, emphasizing the complementary and interconnectedness with higher-precision mass measurement methods. This includes of recent examples from TOF-Bρ mass measurements that map the evolution of nuclear structure across the nuclear landscape and significantly impact the results and interpretation of astrophysical model calculations. I also forecast expected expansion in the known nuclear mass surface from future measurement at the Facility for Rare Isotope Beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neural network emulation of flow in heavy-ion collisions at intermediate energies

Applications of new techniques in machine learning are speeding up progress in research in various fields. In this work, we construct and evaluate a deep neural network (DNN) to be used within a Bayesian statistical framework as a faster and more reliable alternative to the Gaussian process (GP) emulator of an isospin-dependent Boltzmann-Uehling-Uhlenbeck (IBUU) transport model simulator of heavy-ion reactions at intermediate beam energies. We found strong evidence of the DNN being able to emulate the IBUU simulator's prediction on the strengths of protons' directed and elliptical flow very efficiently even with small training datasets and with accuracy about ten times higher than the GP. Here, limitations of our present work and future improvements are also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of liquid-phase thermometry in impinging jet sprays using synchrotron x-ray scattering

Liquid thermometry during primary and secondary breakup of liquid sprays is challenging due to the presence of highly dynamic, optically complex flow features. This work evaluates the use of x-ray scattering from a focused, monochromatic beam of the Advanced Photon Source at Argonne National Laboratory for the measurement of liquid temperatures within the mixing zone of an impinging jet spray. The measured scattering profiles are converted to temperature through a previously developed two-component partial least squares (PLS) regression model. Transmitive mixing during jet merging is inferred through spatial mapping of temperatures within the impingement region. In this work, the technique exhibits uncertainties of ±2K in temperature and 2% in capturing the correct scattering profile, showing its potential utility for probing liquid temperature distributions in multiphase flows.

42 ENGINEERING↗

Carbon nanofibers based carbon–carbon composite fibers

Textile grade polyacrylonitrile (PAN) was used as a precursor material for carbon fiber preparation. E-beam irradiated polyacrylonitrile grafted carbon nanofibers were dispersed in polyacrylonitrile solution (dissolved in dimethyl formamide). Carbon nanofibers (CNF) infused polyacrylonitrile solution was wet spun on a lab-scale wet-spinning setup to form 50 to 70 µm diameter fibers with 3.2 wt.% CNF-PAN, 6.4 wt.% CNF-PAN, and neat PAN. Precursor fibers were characterized for thermal, mechanical and morphological properties using various techniques. Drawing the precursor fibers further enhanced polymer chain orientation and coalesced the voids, enhancing tensile strength and modulus by more than 150% compared to those of the undrawn fibers. Precursor composite fibers on carbonization showed enhanced strength, compared to that of pristine PAN fibers, by four times and stiffness by 14 times. The carbon–carbon composite fibers were further characterized with SEM/FIB, XRD and tensile strength. The property improvements were dependent on the uniform distribution of carbon nanofibers, and surface modification of carbon nanofibers further enabled their dispersion in the composite fibers. Furthermore, 3.2 wt.% CNFs in PAN fibers showed maximum improvement in properties compared to 6.4 wt.% CNF in PAN fibers, indicating that the property enhancements go through a maximum and then drop off due to challenge in getting uniform distribution of nanofibers.

36 MATERIALS SCIENCE↗

Plasma Mirrors For High Power Lasers: A new approach for high repetition rates combined with realistic PIC simulations

We describe a research program to develop high quality plasma mirrors for use with high repetition rate, high power laser facilities to greatly facilitate experiments in high energy density physics, particularly when using solid density targets. A system delivering ultrathin, free standing liquid crystal films that could handle PW class laser pulses was developed that preserved the laser beam image quality and improved pulse contrast by over two orders of magnitude. The pulse contrast improvement was measured using a high dynamic range cross-correlation. The system operated at a repetition rate of several PMs formed in situ per minute. Extension to 1 Hz repetition rates should be possible. As a practical application, a PM system was used to separate laser accelerated electrons from the ultrashort pulse drive laser so that the electron beam emittance could be directly measured. The 20 nm thick PMs did not contribute significantly to emittance degradation. It was also demonstrated that the films could operate in the difficult plasma and laser environment present for GeV laser based electron acceleration. PM operation is still not well understood and much work with PMs is done empirically. Accordingly, we also demonstrated a particle-in-cell based simulation technique that would model PM operation, tracking the PM operation from cold, neutral atoms to a hot dense plasma by accounting for multiphoton ionization, plasma collisionality, and the dynamically changing index of refraction. Simulations in 3D were compared to a 2D based approach that was comparable. Finally, we developed a simpler model that can predict the intensity at which a plasma mirror will have its peak reflectivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent results from MicroBooNE

Modelling and reconstructing neutrino-nucleus scattering is difficult, but it is crucial to do it precisely to enable next-generation oscillation measurements. Liquid argon time projection chambers (LArTPCs), such as MicroBooNE, can be the tool for this job as they are excellent precision neutrino detectors with their ability to produce detailed three-dimensional interaction images and precise energy and spatial resolution. MicroBooNE currently possesses the world's largest neutrino-argon scattering data set collected over five years using the BNB and NuMI neutrino beams at Fermilab. The experiment has performed measurements over a broad range of physics topics including neutrino argon cross sections, searches for BSM physics, and investigations of the MiniBooNE LEE excess. Many of these measurements are essential for improving the modelling of nuclear effects for both MicroBooNE and future LArTPC neutrino experiments, such as DUNE. This talk will give an overview of recent MicroBooNE results, the analysis techniques that enable them, and prospects for future measurements.

Parkinson, Holly B. [U. Edinburgh (main)] (ORCID:0↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Review and Perspective on Cathodoluminescence Analysis of Halide Perovskites

Halide perovskite solar cells have achieved a certified efficiency of 25.2%, surpassing CdTe and CuInGaSe 2 , which have long been regarded as the most-efficient thin-film photovoltaic materials. As this exciting class of materials continues to mature, researchers will require characterization techniques capable of exposing the interplay among structure, chemistry, and optoelectronic properties to inform processing strategies and increase both device efficiencies and long-term stability. Cathodoluminescence microscopy is an ideal technique to provide such information due to the high spatial resolution and robust optical information acquired. Here, the current body of work related to cathodoluminescence analysis of halide perovskite materials for optoelectronic applications is surveyed. This review demonstrates how cathodoluminescence can monitor degradation due to environmental stressors, phase segregation resulting from material processing, and other halide perovskite-centric material issues. A persistent concern associated with e-beam-based analysis of halide perovskites is what effect the electron beam has on the material properties being probed. Addressing this, a detailed discussion is provided on the origin of the cathodoluminescence signal and a review of studies focused on revealing changes in the properties of halide perovskites resulting from e-beam excitation. Finally, a perspective on future opportunities to expand the role of cathodoluminescence analysis for halide perovskites is provided.

14 SOLAR ENERGY↗

Density Measurement of NaCl-MgCl 2 -PuCl 3 and NaCl-UCl 3 -PuCl 3 Molten Salt Systems by Neutron Radiographic Dilatometry

A novel neutron radiographic technique was developed and implemented to measure the change in volume as a function of temperature of select plutonium-containing liquid chloride mixtures from melt to 1250 K. These measurements were performed at Los Alamos National Laboratory by members of the molten salt research group under support from Gateway for Accelerated Innovation in Nuclear (GAIN) voucher NE-21-25117: “Density Measurements of Plutonium Bearing Salts via Neutron Beam Dilatometry”. This technical report contains a description of the experimental method and a summary of the results. Initial characterization of the {NaCl, MgCl 2 , UCl 3 , PuCl 3 } salts used in this experiment includes a combination of x-ray diffraction, differential scanning calorimetry, gamma ray spectroscopy, and inductively coupled plasma mass spectrometry. Four samples of NaCl + MgCl 2 + x mol% PuCl 3 and four samples of NaCl + UCl 3 + x mol% PuCl 3 were prepared at the Plutonium Facility, shipped to the Los Alamos Neutron Science Center (LANSCE), and radiographed with the density via neutron radiography (DvNR) apparatus. Density data in the form of meniscus heights were recorded as a function of temperature. The results show a linear dependence of density with temperature and a third order polynomial dependence of density with composition as a function of PuCl 3 addition in the corresponding halide salt mixture. Additions of PuCl 3 result in a significant increase in density of the salt mixture and a slight reduction in the coefficient of volumetric expansion. These results represent a first measurement of the density of plutonium chloride salt mixtures and, in combination with additional measurements, may lead to a generalized description of the density of such salt systems for arbitrary compositions and temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nanoaperture fabrication in ultra-smooth single-grain gold films with helium ion beam lithography

In this paper, we demonstrate a simple three-step gold thin-film sample preparation process to enhance the morphology and lithographic precision using helium ion based direct-writing. The procedure includes metal deposition, heat treatment and template stripping, which produce smooth monocrystalline gold grains with sizes up to 500 nm and an average surface roughness of 0.267 nm. By using a helium ion microscope, we can fabricate structures with feature sizes less than 20 nm in a 100 nm thick gold film with high-quality sidewalls. We demonstrate the efficacy of this technique by producing high-quality double nanohole (DNH) nanoapertures for single nanoparticle trapping in a single grain of 100 nm thick gold. This procedure can be applied to a wide range of antenna geometries and features that need to be fabricated producing optical and or electronic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗