Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

GlueX a new facility to search for gluonic degrees of freedom in mesons

The GlueX detector facility in Hall-D at Jefferson lab in Newport News is part of the 12 GeV upgrade and dedicated to the search for gluonic degrees of freedom in mesons by scattering high energy linearly polarized real photons of up to 9 GeV from nucleon targets. Civil construction of the Hall-D complex has started as well as the construction of the various detector components. The current status of the project is outlined here.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Continuum model of surface roughening and epitaxial breakdown during low-temperature Ge(001) molecular beam epitaxy

Numerical simulations based on a discrete model describing step edge motion are used to compute the surface morphological evolution of Ge(001) layers deposited by low-temperature (T{sub s} = 45-230 deg. C) molecular beam epitaxy and to probe the relationship between surface roughening and the onset of epitaxial breakdown - the abrupt growth mode transition from epitaxial to amorphous - at temperature-dependent critical film thicknesses h{sub 1}(T{sub s}). Computed surface widths w and in-plane coherence lengths d as a function of layer thickness h exhibit good agreement with experimental values. Inspired by experimental results indicating that epitaxial breakdown is initiated at facetted interisland trenches as the surface roughness reaches a T{sub s}-independent overall aspect ratio, we show that simulated data for w/d = 0.03 correspond to thicknesses h{sub 1{proportional_to}} exp (-E{sub 1}/kT{sub s}) with E{sub 1} = 0.63 eV, a value equal to the Ge adatom diffusion activation energy on Ge(001). Simulated h{sub 1} values agree well with experimental data. Above a critical growth temperature of 170 deg. C, computed w/d values saturate at large film thicknesses, never reaching the critical aspect ratio w/d = 0.03. Thus, the model also predicts that epitaxial breakdown does not occur for T{sub s} > 170 deg. C as observed experimentally.

36 MATERIALS SCIENCE↗

SU-F-J-12: Dosimetrical Characteristics of a 2.5 MV Megavoltage Photon Beam

Purpose: To evaluate the accuracy of modeling scatter factor (SF) and primary off-axis ratio (POAR) for 2.5 MV megavoltage photon beams using an empirical model, which can be used as a dose calculation model for low energy EPID imaging. Methods: Scatter photon parameters were calculated for 2.5 MV photon beam from a Varian TrueBeam by fitting the product of depth dose, PDD, and the phantom scatter factor, Sp, for a range of square field sizes between 2 and 40 cm and depths between 0 and 30 cm. The model is then applied to off-axis profiles measured for a slit field (3cm ×35 cm) for 5 depths: 0.6, 5, 10, and 20, 30 cm. Primary off-axis ratio (POAR) values were determined based on the fitting to data using the empirical model. Results: The fitting to PDD*Sp has a maximum error of 14%, mostly near surface, where backscattering of photons dominate and has a standard deviation of 4.7%. The attenuation coefficient and beam-hardening coefficient of the beam is determined to be 0.095 1/cm and 0.0038 1/cm, respectively. POAR for 2.5 MV has a peak in the center, corresponding to a beam without sufficient material to flatten the beam. Conclusion: This work illustrates a deficiency of the current empirical model to fit SF for a 2.5 MV photon beams. Most of the errors are near the surface region and an improved model that incorporate better modeling of backscattering can be developed to improve the model accuracy.

60 APPLIED LIFE SCIENCES↗

A model-based scatter artifacts correction for cone beam CT

Purpose: Due to the increased axial coverage of multislice computed tomography (CT) and the introduction of flat detectors, the size of x-ray illumination fields has grown dramatically, causing an increase in scatter radiation. For CT imaging, scatter is a significant issue that introduces shading artifact, streaks, as well as reduced contrast and Hounsfield Units (HU) accuracy. The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. Methods: The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain or projection domain. A denoising algorithm designed specifically for Poisson signals is then applied to derive the final scatter distribution. Qualitative and quantitative evaluations using thorax and abdomen phantoms with Monte Carlo (MC) simulations, experimental Catphan phantom data, and in vivo human data acquired for a clinical image guided radiation therapy were performed. Scatter correction in both projection domain and image domain was conducted and the influences of segmentation method, mismatched attenuation coefficients, and spectrum model as well as parameter selection were also investigated. Results: Results show that the proposed algorithm can significantly reduce scatter artifacts and recover the correct HU in either projection domain or image domain. For the MC thorax phantom study, four-components segmentation yields the best results, while the results of three-components segmentation are still acceptable. The parameters (iteration number K and weight β) affect the accuracy of the scatter correction and the results get improved as K and β increase. It was found that variations in attenuation coefficient accuracies only slightly impact the performance of the proposed processing. For the Catphan phantom data, the mean value over all pixels in the residual image is reduced from −21.8 to −0.2 HU and 0.7 HU for projection domain and image domain, respectively. The contrast of the in vivo human images is greatly improved after correction. Conclusions: The software-based technique has a number of advantages, such as high computational efficiency and accuracy, and the capability of performing scatter correction without modifying the clinical workflow (i.e., no extra scan/measurement data are needed) or modifying the imaging hardware. When implemented practically, this should improve the accuracy of CBCT image quantitation and significantly impact CBCT-based interventional procedures and adaptive radiation therapy.

60 APPLIED LIFE SCIENCES↗

MARS15 Simulation of Radiation Environment at the ESS Linac

Comprehensive studies with the MARS15(2016) Monte-Carlo code are described on evaluation of prompt and residual radiation levels induced by nominal and accidental beam losses in the 5-MW, 2-GeV European Spallation Source (ESS) Linac. These are to provide a basis for radiation shielding design verification through the accelerator complex. The calculation model is based on the latest engineering design and includes a sophisticated algorithm for particle tracking in the machine RF cavities as well as a well-established model of the beam loss. Substantial efforts were put in solving the deep-penetration problem for the thick shielding around the tunnel with numerous complex penetrations. It allowed us to study in detail not only the prompt dose, but also component and air activation, radiation loads on the soil outside the tunnel, and skyshine studies for the complicated 3-D surface above the machine. Among the other things, the newest features in MARS15 (2016), such as a ROOT-based beamline builder and a TENDL-based event generator for nuclear interactions below 100 MeV, were very useful in this challenging application

Mokhov, N. V.↗

Bending strength model for internal spur gear teeth

Internal spur gear teeth are normally stronger than pinion teeth of the same pitch and face width since external teeth are smaller at the base. However, ring gears which are narrower have an unequal addendum or are made of a material with a lower strength than that of the meshing pinion may be loaded more critically in bending. In this study, a model for the bending strength of an internal gear tooth as a function of the applied load pressure angle is presented which is based on the inscribed Lewis constant strength parabolic beam. The bending model includes a stress concentration factor and an axial compression term which are extensions of the model for an external gear tooth. The geometry of the Lewis factor determination is presented, the iteration to determine the factor is described, and the bending strength J factor is compared to that of an external gear tooth. This strength model will assist optimal design efforts for unequal addendum gears and gears of mixed materials.

Savage, Michael↗

Classical trajectory Monte Carlo code for simulating ion beam focusing or defocusing with magnetic elements modeled as current loops or current lines

A computational tool is described that can be used for designing magnetic focusing or defocusing systems. A fully three-dimensional classical trajectory Monte Carlo simulation has been developed. Ion trajectories are simulated in the presence of magnetic elements that can be modeled as any combination of current loops and current lines. Each current loop or line may be located anywhere in the system and oriented along any of the three coordinate axes. The configuration need not be axisymmetric. The solutions are obtained using normalized parameters, which can be used for easily scaling the results. Examples are provided of the utility of the code.

43 PARTICLE ACCELERATORS↗

Size-distribution evolution of ion-beam-synthesized nanoclusters in silica

A model to describe the growth of nanoclusters in silica via ion-beam synthesis is introduced. Kinetic Monte Carlo simulations indicate that nucleation, growth, coarsening, and fragmentation occur throughout implantation, leading to a steady-state size-distribution shape that agrees with experimental observations. A set of coupled rate equations are derived and solved within a self-consistent mean-field approximation. An intermediate asymptotic scaling analysis helps to identify the important experimentally accessible parameters that control ion-beam-synthesized nanocluster size distributions. The model predicts that the shape of the as-implanted size distribution depends only on a characteristic length governed by the effective diffusivity, effective ion solubility, and the volumetric flux while the average cluster size is determined by the solute/matrix interface energy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fusion by beam ions in a low collisionality, high mirror ratio magnetic mirror

Abstract The classical problem of neutral beam ions slowing down in a magnetic mirror geometry is revisited to provide predictive capability for the new Wisconsin HTS Axisymmetric Mirror under development at the University of Wisconsin. A Fokker–Planck model named fast beam ion solver (FBIS) is developed to include the spatial non-uniformity of a physical mirror geometry. The mathematical framework allows for efficient orbit averaging of the pitch-angle scattering operator, and permits a determination of the axial profile of the ambipolar potential confining the electrons. The numerical results from FBIS are consistent with earlier work, but further show how mirror-ratio and a near square magnetic well optimizes the fusion gain. The numerical results are also applied to inform the conceptual design of WHAM++, a low capital-cost breakeven-class magnetic mirror device.

Egedal, J. (ORCID:0000000177531529)↗

Recent advances in control of nonlinear and distributed parameter systems, robust control, and aerospace control applications; Proceedings of the Symposium, ASME Winter Annual Meeting, Chicago, IL, Nov. 27-Dec. 2, 1988

Papers are presented on the control of distributed parameter systems using the coprime factorization approach, a hierarchy of geometrically exact models of rotating beams, and the temperature stability of a flux modulated radiant slab. Also considered are a network representation for robots, recovery from controller bounding, and the design of controllers for robust tracking and model following. Other topics include an active control law synthesis for flexible aircraft, the low-order control of large aerospsace structures using residual model filters, and a comparison of component cost methods for component model reduction.

Bentsman, Joseph↗

Start-to-End Tracking Simulations of the Compact Linear Collider

We present the current status of the beam tracking simulations of the Compact Linear Collider (CLIC) from the exit of the damping ring to the interaction point, including the ring to main linac (RTML) section, main linac, beam delivery system (BDS) and beam-beam interactions. This model introduces realistic alignment survey errors, dynamic imperfections and also the possibility to study collective effects in the main linac and the BDS. Special emphasis is put on low emittance transport and beam stabilisation studies, applying beam based alignment methods and feedback systems. The aim is to perform realistic integrated simulations to obtain reliable luminosity predictions.

43 PARTICLE ACCELERATORS↗

Fabrication and test of model superconducting inflector for g-2 at FNAL

The new FNAL g-2 experiment is based on the muon storage ring previously used at BNL. The 1.45 T dipole magnetic field in the storage ring is required to have very high (1 ppm) homogeneity. The muon beam injected into the ring must be transported through the magnet yoke and the main superconducting coil cryostat with minimal distortions. The old inflector magnet shielded the main dipole fringe field inside the muon transport beam pipe, with an outer NbTi superconducting screen, and did not disturb the field in the area of circulating beam. Nevertheless, this magnet had coils with closed ends in which a large fraction of muon beam particles were lost. A new magnet is envisioned utilizing the same cross section as the original with open ends for improved beam transport. A model magnet has been wound utilizing 3d printed parts to verify the magnetic behavior of the magnet at room temperature and validate winding of the complicated geometry required for the magnet ends. Finally, room temperature magnetic measurements have been performed and confirm the magnetic design

43 PARTICLE ACCELERATORS↗

Observation of a J{sup PC}=1{sup -+} Exotic Resonance in Diffractive Dissociation of 190 GeV/c {pi}{sup -} into {pi}{sup -{pi}-{pi}+}

The COMPASS experiment at the CERN SPS has studied the diffractive dissociation of negative pions into the {pi}{sup -{pi}-{pi}+} final state using a 190 GeV/c pion beam hitting a lead target. A partial wave analysis has been performed on a sample of 420 000 events taken at values of the squared 4-momentum transfer t{sup '} between 0.1 and 1 GeV{sup 2}/c{sup 2}. The well-known resonances a{sub 1}(1260), a{sub 2}(1320), and {pi}{sub 2}(1670) are clearly observed. In addition, the data show a significant natural-parity exchange production of a resonance with spin-exotic quantum numbers J{sup PC}=1{sup -+} at 1.66 GeV/c{sup 2} decaying to {rho}{pi}. The resonant nature of this wave is evident from the mass-dependent phase differences to the J{sup PC}=2{sup -+} and 1{sup ++} waves. From a mass-dependent fit a resonance mass of (1660{+-}10{sub -64}{sup +0}) MeV/c{sup 2} and a width of (269{+-}21{sub -64}{sup +42}) MeV/c{sup 2} are deduced, with an intensity of (1.7{+-}0.2)% of the total intensity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fluorescence-type Monochromatic X-ray Beam-position Monitor with High-spatial Resolution for the NSLS-II Beamlines

We developed a fluorescence-type monochromatic X-ray beam-position monitor (X-BPM) with high-spatial resolution for end-station experiments at the initial project beamlines of the NSLS-II. We designed a ring array of multi-segmented Si PIN-junction photodiodes to use as a position sensor. Further, we integrated a low-noise charge-preamplification HERMES4 ASIC chip into an electronic readout system for photon-counting application. A series of precision measurements to characterize electronically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise from the detector system is sufficiently low to meet our stringent requirements. Using a Gaussian beam, we parametrically modeled the optimum working distance to ensure the detector's best performance. Based upon the results from the parametric modeling, prototypes of the next versions of the X-BPM are being developed. In this paper, we describe the methodology for developing the new compact monochromatic X-ray BPM, including its instrumentation, detector modeling, and future plan.

43 PARTICLE ACCELERATORS↗

TH-CD-201-03: A Real-Time Method to Simultaneously Measure Linear Energy Transfer and Dose for Proton Therapy Using Organic Scintillators

Purpose: The light generated in organic scintillators depends on both the radiation dose and the linear energy transfer (LET). The LET dependence leads to an under-response of the detector in the Bragg peak of proton beams. This phenomenon, called ionization quenching, must be corrected to obtain accurate dose measurements of proton beams. This work exploits the ionization quenching phenomenon to provide a method of measuring LET and auto correcting quenching. Methods: We exposed simultaneously four different organic scintillators (BCF-12, PMMA, PVT, and LSD; 1mm in diameter) and a plane parallel ionization chamber in passively scattered proton beams to doses between 32 and 43 cGy and fluence averaged LET values from 0.47 to 1.26 keV/µm. The LET values for each irradiation condition were determined using a validated Monte Carlo model of the beam line. We determined the quenching parameter in the Birk’s equation for scintillation in BCF-12 for dose measurements. One set of irradiation conditions was used to correlate the scintillation response ratio to the LET values and plot a scintillation response ratio versus LET calibration curve. Irradiation conditions independent from the calibration ones were used to validate this method. Comparisons to the expected values were made on both the basis of dose and LET. Results: Among all the scintillators investigated, the ratio of PMMA to BCF-12 provided the best correlation to LET values and was used as the LET calibration curve. The expected LET values in the validation set were within 2%±6%, which resulted in dose accuracy of 1.5%±5.8% for the range of LET values investigated in this work. Conclusion: We have demonstrated the feasibility of using the ratio between the light output of two organic scintillators to simultaneously measure LET and dose of therapeutic proton beams. Further studies are needed to verify the response in higher LET values.

60 APPLIED LIFE SCIENCES↗

Remote laser speckle interferometry: A speckle pattern formation model

A mathematical model of laser radiation scattering from a remote rough surface illuminated by a focused laser beam is proposed. The model can be used to estimate the mean number and size of speckles and their mean and maximum intensity. Fluctuations of the speckle intensity were observed upon focusing radiation in the object plane. The magnitude of fluctuations achieves 50%-70% and depends on the object roughness and the laser beam parameters. (laser radiation scattering)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Filamentation and focusing of electron beams due to interactions with plasma waves

Results of numerical modeling of the interaction of an electron beam propagating across relativistic plasma waves indicate that electron beam filamentation and focusing may occur under certain conditions. The model is based on solving the relativistic equation of motion in three dimensions for the individual electrons in a tenuous Gaussian beam, as they pass through a relativistic plasma wave. Several electron beam and plasma wave parameters were varied, and the results are summarized. One of the results is that the spacing of the electron beam filaments correlates with the wavelength of the plasma wave. The electron beam filaments appear as vertical slabs after the beam exits the plasma waves. The electron beam also compresses to a focus after it exits the plasma, and the focal distance depends on several parameters including the electron beam energy and phase velocity of the relativistic plasma wave. It is suggested that these focusing and filamentation phenomena may be the basis for diagnostics schemes for laser plasma interactions. The parameters used in the model were electron beam energies in the 5–50 keV range and plasma wave properties typical for the beat-wave produced by CO2 lasers, which correspond to the facilities available in our laboratory. The limitations of these results to lower energy density beam and plasma regimes and to higher energy density regimes will be discussed.

47 OTHER INSTRUMENTATION↗

Fermilab Booster loss modelling and rebalancing using Bayesian methods

To meet PIP-II upgrade requirements, Fermilab Booster losses need to be reduced by 50% compared to present levels. So far, simulations are not good enough to predict loss patterns. Thus, an extensive Booster tune up will be necessary to achieve required performance. In this paper we present an effort to build a data-driven loss model using Bayesian techniques, and subsequently to rebalance losses for higher trip margins. We first created several sets of spatially and temporally isolated orbit and optics knobs, and trained Gaussian process models for each beam loss monitor as well as beam current. Novel techniques of uncertainty constraints and approximate GP fitting were introduced to handle safety and timing requirements. We then performed single and multi-objective tuning using scalarized objectives comprised of critical beam loss locations. We achieved significant rebalancing of losses, increasing margins by 25%, as well as an overall improvement in transmission efficiency of 0.4%. Automated data collection is being developed so that more accurate surrogate models can be trained over time.

Kuklev, N. [Fermilab]↗