Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “attenuator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Microstructural Characterization of Nb$_3$Sn Thin Films Using FIB Tomography

The accelerating gradient of N b3Sn superconducting radiofrequency (SRF) cavities is currently limited, and the underlying cause remains an open question in the field. One leading hypothesis attributes this limitation to the presence of tin-deficient regions within the N b3Sn coating, which can suppress the superheating field. Due to the relatively large coherence length of N b3Sn, defects near the surface may significantly interact with the RF field. However, these subsurface defects have proven difficult to characterize. This research aims to investigate the structure and distribution of subsurface Sn deficient regions to better understand their influence on cavity performance. We employ focused ion beam (FIB) tomography to analyze the subsurface microstructure of N b3Sn thin films. This technique enables threedimensional reconstruction of both the tin distribution and the grain structure within the film. By correlating Sn content with grain structure, we find that Sn deficient regions are more prevalent that previously thought. However, the Sn deficient regions are consistently located below the surface of the film where RF fields are strongly attenuated by supercurrent screening and are likely not a limiting factor for cavity performance

Viklund, Eric [Fermilab]↗

Identification of the Liquid Argon Scattering Experimental Discrepancies Using Simulation

Scintillation light analysis in liquid argon based neutrino detectors is restrained in capability due to uncertainty in fundamental constants critical to the analysis process. One such property is the Rayleigh scattering length of liquid argon. In the fall of 2023, the TallBo cryostat, located in the Proton Assembly Building at Fermilab, was used to study the scattering length of liquid argon in the Liquid Argon Scattering (LArS) experiment. Due to systematic errors unknown during measurement analysis, LArS’s measurements were quite uncertain. By simulating the LArS experiment, we found that the downturn in detector count rate as a function of liquid argon height at low heights was caused by a misplaced photo multiplier. With concentrated effort, we may be able to successfully correct this effect by understanding the relationship between the specified Rayleigh scattering length and the measured attenuation length. With this information and further progression in analysis, we may be able to extract corrected measurements from the LArS data and attain a tangible experimental measurement of the scattering length of liquid argon.

Breaux, Auto D. [Tulane U.; Fermilab]↗

Embedding of Fiber Optic Sensors in Stainless Steel for Sensing in Harsh Environments

Structural health monitoring is critical for components working in harsh environments to assess their safety and integrity. This can be realized with advanced sensors, such as fiber optic sensors, embedded in these components. Recent studies have used ultrasonic consolidation (UC) and laser-based additive manufacturing (AM) techniques to embed fiber optic sensors in metals. However, sensor embedding using these techniques has been challenging, with gaps and voids around the embedded fiber. Successful embedding of fiber optic sensors requires good contact between the fiber and the matrix to eliminate potential gas/liquid leaks in critical systems such as in nuclear and aerospace services. Defect-free fiber/matrix bond is also essential for accurate measurement of parameters of interest, such as temperature and strain. This study developed a novel fiber embedding technique based on electric field-assisted sintering (EFAS). Sapphire optical fibers with diameters of 125 µm and 250 µm were embedded in stainless steel (SS) 316L using EFAS. The embedding was completed by sintering SS 316L powders at a pressure of 50MPa, hold time of 5 min, and temperatures of 1000°C, 1100°C, and 1200°C. Joule heating mechanism during EFAS enabled rapid sintering of the SS 316L powder with resulting sample densities over 99%. Microscopy analysis performed on the cross-sections revealed a defect-free bond between the embedded fiber and SS 316L. The good integrity of the embedded fiber was evidenced by optical transmittance measurement. Optical attenuation of the fiber before and after embedment was examined in the near-infrared region. Scanning electron microscopy was employed to investigate the grain morphology of SS 316L near the embedded fiber. Hardness distribution in the sintered part was also investigated to study the effect of the embedded fiber on the mechanical properties of the as-fabricated component. The results indicated that EFAS was able to embed fiber in SS with good fiber functionality and part quality.

36 - MATERIALS SCIENCE↗

Embedding Fiber Optic Sensors in Stainless Steel using Spark Plasma Sintering for Structural Health Monitoring in Harsh Environments

Embedded fiber optic sensors such as fiber Bragg gratings (FBGs) offer a unique route for distributed real-time in-situ imaging of various engineering parameters for numerous purposes. This study advanced the current sensor embedding approaches by exploring a spark plasma sintering (SPS)-assisted technology to embed FBGs in high-temperature structural materials and demonstrated the capability of temperature measurement. In this approach, single-mode FBGs were integrated into stainless steel (SS) 316L components using SPS, followed by the evaluation of the bonding quality between the FBGs and matrix, the optical attenuation of the fibers induced by embedding, and the sensing characters of the FBGs under temperature stimuli. The results demonstrated that superior bonding was achieved between the FBGs and highly-densified SS316L. Examination of the behavior of Bragg gratings validated signal fidelity after embedding. Real-time thermal imaging under temperature cycling using the FBGs demonstrated the effectiveness of the technique for smart materials manufacturing.

36 - MATERIALS SCIENCE↗

AGC-4 As-Run Uncertainty Analysis

The concept of measuring neutron flux (or fluence rate) with activation foils has existed since the late 1940s and is a well-used methodology. Activation foils are selected for their unique isotopic cross sections that create reaction products with desirable properties: relatively simple radioactive decay scheme, measurable quantities of gamma-rays or betas, and half-lives appropriate for the irradiation and decay durations of the experiment. The activation materials, deemed flux wires, fluence wires, dosimeters, or flux foils, are fabricated to have a mass appropriate for the irradiation as well so the measurement using a radiation detector following the irradiation is sufficient but not overwhelming in terms of total activity. Activation measurement results are expressed in terms of reaction rate, which can then be used to “adjust” the neutron spectrum. The Advanced Graphite Creep (AGC)-4 experiment contained 26 flux wire packages, each containing an iron and a niobium wire inside a vanadium capsule. For all stackup positions, the value of fast to thermal neutrons is higher than expected, but the total neutron fluence is near the predicted value of ~2 x 1022 n/cm2. As compared to the predicted neutron spectrum, there are four takeaways in the results as compared to the predicted ATR irradiation: 1) Additional fast (fission) neutrons present, 2) Spectrum hardening due to temperature, 3) Spectrum hardening due to container attenuation, 4) Total neutron fluence is close to predicted values. Since the neutron energy spectrum is a key parameter when attributing neutron damage in materials, the adjusted energy-dependent spectrum and the total neutron fluence results from the dosimeters can be incorporated for future calculations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benefits and challenges of vibroacoustic process monitoring to support operators in nuclear research facilities

According to the International Atomic Energy Agency in 2024, global nuclear energy capacity is projected to increase by 2.5 times by 2050 in their high-case scenario. Research on the laboratory scale of innovative processes within nuclear facilities is ongoing to improve nuclear fuel cycle capabilities. Vibroacoustic process monitoring of these techniques has potential to inform operators regarding process specific metrics, predictive maintenance, and anomalous event detection. Additionally, this type of monitoring has the potential to aid in nuclear safeguards. Challenges regarding vibroacoustic monitoring in these environments include high temperature, high radiation, limited access, and shielded equipment limiting sensor type and placement. Microphones, accelerometers, and temperature sensors were deployed both inside and near these environments during operation to determine environment driven limitations, sound attenuation of containment enclosures, process specific metrics, and future potential of vibroacoustic monitoring in these environments. Overall, this work highlights the benefits and limitations of vibroacoustic process monitoring in nuclear research facilities.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detection of scintillation light in noble gases with wavelength-shifting optical fibers

Wavelength-shifting (WLS) techniques enable particle detectors based on noble gases, whose scintillation light is predominantly emitted in the vacuum-ultraviolet. We investigate WLS fibers coated with tetraphenyl butadiene (TPB) for scintillation light detection in gaseous xenon and argon at pressures up to 8.5 bar, motivated by future high-pressure xenon time-projection chambers of the NEXT program. Two detector configurations are studied: an elongated high-pressure vessel with four PTFE panels equipped with WLS fibers read by temperature-stabilized SiPMs, and a compact box-shaped detector operated at 1 bar Xe with WLS fibers read out by PMTs. Both operate with continuous gas purification. The detector response is characterized using cosmic muons and alpha particles from a $^{241}$Am source. With the SiPM setup, we measure a light collection efficiency (LCE) of ${1.18 \pm 0.01~\mathrm{(sta.)}~^{+0.07}_{-0.09}~\mathrm{(sys.)}~\%}$ for xenon and ${1.07 \pm 0.01~\mathrm{(sta.)}~^{+0.06}_{-0.08}~\mathrm{(sys.)}~\%}$ for argon. With PMT readout, we measure a LCE of ${0.45 \pm 0.01~\mathrm{(sta.)} \pm 0.05~\mathrm{(sys.)}~\%}$ in xenon, in agreement with the SiPM result once photon detection efficiency is accounted for. Average scintillation waveforms in xenon and argon are studied to assess the time structure of the emitted light. Cosmic-muon measurements yield a mean energy required to produce a scintillation photon $45\pm7~\mathrm{(sta.)}~^{+4}_{-5}~\mathrm{(sys.)}~\mathrm{eV}$ at 1.5 bar, in agreement with the literature. The results demonstrate that TPB-coated WLS fiber systems can reliably detect scintillation light in high-pressure gaseous noble detectors, with a LCE representing an upper limit for realistic large-scale TPCs, where additional photon losses from materials and fiber attenuation are expected.

Soleti, S. R. [Donostia Intl. Phys. Ctr., San Seba↗

Selective Amnesia using Contrastive Subnet Erasure for Class Level Unlearning in Vision Models

We study concept-level forgetting in pretrained vision models: removing an entire semantic category so the system no longer recognizes that object in unseen images and contexts, rather than merely forgetting specific training examples. Prior work either applies blunt global projections or fine-tunes parameters, which can introduce collateral damage to unrelated features, add compute, and become unstable as forgetting strength increases. We introduce Contrastive Subnet Erasure (CSE), a training-free, encoder-centric edit that targets a compact set of channels most responsible for the class and attenuates them in a calibrated manner. The modification is algebraically folded into the subsequent layer, yielding no inference-time overhead and leaving task heads unchanged. To evaluate whether forgetting generalizes beyond the data used to specify the class, we introduce a cross dataset protocol in which the class is defined on a source dataset and performance is measured on a disjoint target dataset drawn from a different distribution with no shared images. This setup tests whether the model still fails to recognize the object when it looks different or appears in new scenes, and it helps avoid overfitting to patterns in the source dataset. Across CIFAR 10, CIFAR 100, and ImageNet under this protocol, CSE achieves stronger forgetting of the target class while better preserving non target utility than existing baselines in both single class and multi class settings. Overall, CSE provides a simple, stable, and deployment-ready mechanism for class-level unlearning in vision.

Kotevska, Olivera [ORNL] (ORCID:0000000316772243)↗

An upgraded frequency-selectable laser source (FLS) calibrator for CMB bandpass characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from the uncertainty in instrument bandpass calibration. Uncertainties in bandpass can limit foreground removal and spectral fitting, which are critical for inflationary and galaxy cluster measurements. CMB experiments currently use Fourier Transform Spectrometers (FTSes) to measure instrument bandpasses. However, FTS systems are currently systematics-limited, so significant improvements in bandpass measurements require novel calibrators. To this end, we developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency coupled to a system that allows for laser power attenuation. Following initial testing with the first FLS prototype, we developed an upgraded version of the calibrator with improved performance. We present the upgrades to the FLS calibrator, the characterization of the upgraded calibrator and new laser source, and plans for testing with microwave instruments in the field.

Saunders, Lauren J. [Fermilab] (ORCID:000000016367↗

Quality and Loss Factor Characterization of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons under a strong magnetic field through resonant cavity techniques. The conversion produces an extremely small signal, requiring a cryogenic environment to reduce thermal noise, and low-loss superconducting transmission lines for minimal attenuation in the readout chain. Yttrium barium copper oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss cryogenic cables such as niobium (Nb) and niobium titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We characterized the quality and loss of five stripline resonators from the Brookhaven Technology Group: three YBCO, a copper reference, and a silver reference. Experimental methodology included collecting scattering parameter data on a vector network analyzer for the samples at 77 K along with room temperature baseline measurements, and employing both Lorentzian-fit and circle-fitting techniques to confirm the coupling regime and corroborate results. We achieved quality factors on the order of $10^3$ with corresponding loss factors on the order of $10^{-1}$ dB/m. Trends were comparable with literature data on Nb and NbTi at 4 K, which did have lower loss under these conditions, but suggested similar or perhaps better loss for YBCO when accounting for the temperature difference. We also developed a cryogenic probe for future measurements in a 14 T applied field at 30 mK. This will serve to directly evaluate YBCO's durability in magnetic fields, and we expect significantly improved performance at millikelvin temperatures.

Marinos, Z. [UCLA]↗

Synchrotron X-ray based particle image velocimetry to measure multiphase streamflow and densitometry

Synchrotron-based radiation techniques are increasingly used in the field of flow condition measurements. As a complicated multiphase flow, cavitation has been investigated in a wide variety of industrial fields, to prevent damages on spillways at large dams or intensify the bacteria eradication rate during water treatments. To control the detrimental effects of cavitating flows, the dynamics of and mechanisms affecting cavitation development shall be visualized and identified in real-time. Due to the large reflection and scattering effects of multiphase flow, standard visible-light imaging technologies cannot penetrate vapor bubbles and provide extremely limited information. In this study, the synchrotron source emitted high-flux X-ray pulses are used to capture flow motion and visualize internal structures with sufficiently high spatial and temporal resolutions. The image processing procedures on raw x-ray images are developed using 2D Fourier transform (FT) and wavelet transform (WT) to implement the contrast enhancement and de-noising. Through the edge detection algorithm, tracking either seeded particles or phase interfaces inside the opaque multiphase flow can be achieved to perform the particle image velocimetry. Further, with decomposing particle-only and particle-eliminated subplots from the X-ray phase-contrast image, the time-resolved velocity and void fraction fields are obtained simultaneously, paving a way for further flow condition analysis such as densitometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Seismic constraints from a Mars impact experiment using InSight and Perseverance

NASA’s InSight (Interior Exploration using Seismic Investigations, Geodesy and Heat Transport) mission has operated a sophisticated suite of seismology and geophysics instruments on the surface of Mars since its arrival in 2018. On 18 February 2021, we attempted to detect the seismic and acoustic waves produced by the entry, descent and landing of the Perseverance rover using the sensors onboard the InSight lander. Similar observations have been made on Earth using data from both crewed and uncrewed spacecraft, and on the Moon during the Apollo era, but never before on Mars or another planet. This was the only seismic event to occur on Mars since InSight began operations that had an a priori known and independently constrained timing and location. It therefore had the potential to be used as a calibration for other marsquakes recorded by InSight. Here we report that no signal from Perseverance’s entry, descent and landing is identifiable in the InSight data. Nonetheless, measurements made during the landing window enable us to place constraints on the distance–amplitude relationships used to predict the amplitude of seismic waves produced by planetary impacts and place in situ constraints on Martian impact seismic efficiency (the fraction of the impactor kinetic energy converted into seismic energy).

79 ASTRONOMY AND ASTROPHYSICS↗

An intranasal recombinant NDV-BRSV F opt vaccine is safe and reduces lesion severity in a colostrum-deprived calf model of RSV infection

Human respiratory syncytial virus (HRSV) is a major cause of severe lower respiratory tract disease in infants and the elderly, yet no safe, effective vaccine is commercially available. Closely related bovine RSV (BRSV) causes respiratory disease in young calves, with many similar features to those seen in HRSV. We previously showed that a Newcastle disease virus (NDV)-vectored vaccine expressing the F glycoprotein of HRSV reduced viral loads in lungs of mice and cotton rats and protected from HRSV. However, clinical signs and pathogenesis of disease in laboratory animals following HRSV infection differs from that observed in human infants. Thus, we examined whether a similar vaccine would protect neonatal calves from BRSV infection. Codon-optimized rNDV vaccine (rNDV-BRSV F opt ) was constructed and administered to colostrum-deprived calves. The rNDV-BRSV F opt vaccine was well-tolerated and there was no evidence of vaccine-enhanced disease in the upper airways or lungs of these calves compared to the non-vaccinated calves. We found two intranasal doses reduces severity of gross and microscopic lesions and decreases viral load in the lungs. Furthermore, serum neutralizing antibodies were generated in vaccinated calves. Finally, reduced lung CXC chemokine levels were observed in vaccinated calves after BRSV challenge. In summary, we have shown that rNDV-BRSV F opt vaccine is safe in colostrum-deprived calves, and is effective in reducing lung lesions, and decreasing viral load in upper respiratory tract and lungs after challenge.

60 APPLIED LIFE SCIENCES↗

Conceptual study on using Doppler backscattering to measure magnetic pitch angle in tokamak plasmas

We introduce a new approach to measure the magnetic pitch angle profile in tokamak plasmas with Doppler backscattering (DBS), a technique traditionally used for measuring flows and density fluctuations. The DBS signal is maximised when its probe beam's wavevector is perpendicular to the magnetic field at the cutoff location, independent of the density fluctuations [Hillesheim \emph{et al} 2022 \emph{Nucl. Fusion} \textbf{55} 073024]. Hence, if one could isolate this effect, DBS would then yield information about the magnetic pitch angle. By varying the toroidal launch angle, the DBS beam reaches cutoff with different angles with respect to the magnetic field, but with other properties remaining similar. Hence, the toroidal launch angle which gives maximum backscattered power is thus that which is matched to the pitch angle at the cutoff location, enabling inference of the magnetic pitch angle. We performed systematic scans of the DBS toroidal launch angle for repeated DIII-D tokamak discharges. Experimental DBS data from this scan were analysed and combined with Gaussian beam-tracing simulations using the Scotty code [Hall-Chen \emph{et al} 2022 \emph{Plasma Phys. Control. Fusion} \textbf{64} 095002]. The pitch-angle inferred from DBS is consistent with that from magnetics-only and motional-Stark-effect-constrained (MSE) equilibrium reconstruction in the edge. In the core, the pitch angles from DBS and magnetics-only reconstructions differ by one to two degrees, while simultaneous MSE measurements were not available. The uncertainty in these measurements was under a degree; we show that this uncertainty is primarily due to the error in toroidal steering, the number of toroidally separated measurements, and shot-to-shot repeatability. We find that the error of pitch-angle measurements can be reduced by optimising the poloidal launch angle and initial beam properties. Since DBS has high spatial and temporal resolutions, is non-perturbative, does not require neutral beams, and is likely robust to neutron damage of and debris on the first mirrors, using DBS to measure the pitch angle in future fusion energy systems is especially appealing.

beam tracing↗

Laboratory investigation of hydraulic fracturing in granitic rocks using active and passive seismic monitoring

SUMMARY Knowledge of the fracturing processes can be important for the optimization of pressurized fluid injection operations in the deep underground rock mass. Active and passive seismic monitoring techniques have been used in the field for tracking or mapping the propagating hydraulic fracture. Although both these monitoring techniques provide valuable information about the generated fracture network, it is difficult for either technique to comprehensibly identify the different processes associated with hydraulic fracturing. The combined active and passive monitoring has the potential for better characterization of the complex hydraulic fracturing phenomena. In this study, laboratory hydraulic fracturing experiments with combined active and passive seismic monitoring were conducted on true triaxially loaded Barre granite cubes with different fluid injection rates. The seismic inelastic fracturing was detected by 16 passive acoustic emission sensors, where 3678 and 2370 seismic source events were detected for the high and low injection rate experiments, respectively. For active monitoring, strong variations in the attributes of signals were observed which were transmitted through four source–receiver pairs, placed both perpendicular and parallel to the generated hydraulic fracture. Positive velocity changes were observed for active sensor pairs with ray paths passing through the generated hydraulic fracture indicating fluid permeation, whereas isolated dry deformation was characterized by a slight but permanent velocity decrease. Compared to velocity, the energy of the active signals was 1–2 orders of magnitude more sensitive to different hydraulic fracturing processes. However, the sensitivity and signatures of the active signal attributes were found to be dependent on the frequency range and direction of ray path with respect to the location of the generated fracture network. Using the coupled evaluation of the active and passive signals we were able to systematically identify various hydraulic fracturing processes including: (1) aseismic deformation, (2) fracture initiation and fluid permeation, (3) pressure build-up, (4) fracture propagation and (5) pressure release and leak-off. The results of this study showed that combining the respective advantages of active and passive seismic techniques and using both of them to monitor the failure processes can facilitate a more comprehensive understanding and better control of the hydraulic stimulations in subsurface operations.

Geochemistry & Geophysics↗

Optimal Control for X-Ray Mircroscopes

In this article, a systematic framework for designing the control for fine positioning (scanning) stages of X-ray microscopes is presented. This framework facilitates designs that simultaneously achieve specifications on positioning resolution and tracking bandwidth while guaranteeing robustness of the closed loop device to unmodeled uncertainties. We use robust optimal control techniques for modeling, quantifying design objectives and system-specific challenges, and designing the control laws. The control designs were implemented on a three degree of freedom piezoactuated flexure stages dedicated for fine positioning of X-ray optics. Experimental results demonstrate significant improvements in positioning performance of 134%, 150%, and 132% in tracking bandwidths along the lateral (X), vertical (Y), and beam (Z) directions, respectively, when compared to proportional-integral-derivative controller designs. This was achieved while keeping similar or better positioning resolution and robustness measures. Fast scanning for X-ray imaging was demonstrated in both the step scan and flyscan modes, where bandwidth was improved by over 450 times with flyscan compared to the step scan.

42 ENGINEERING↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Additionally, key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗