Top-up operation at Pohang Light Source-II

After three years of upgrading work, PLS-II (S. Shin, Commissioning of the PLS-II, JINST, January 2013) is now successfully operating. The top-up operation of the 3 GeV linear accelerator had to be delayed because of some challenges encountered, and PLS-II was run in decay mode at the beginning in March 2012. The main difficulties encountered in the top-up operation of PLS-II are different levels between the linear accelerator and the storage ring, the 14 narrow gap in-vacuum undulators in operation, and the full energy injection by 3 GeV linear accelerator. Large vertical emittance and energy jitter of the linac were the major obstacles that called for careful control of injected beam to reduce beam loss in the storage ring during injection. The following measures were taken to resolve these problems: (1) The high resolution Libera BPM (see http://www.i-tech.si ) was implemented to measure the beam trajectory and energy. (2) Three slit systems were installed to filter the beam edge. (3) De-Qing circuit was applied to the modulator system to improve the energy stability of injected beam. As a result, the radiation by beam loss during injection is reduced drastically, and the top-up mode has been successfully operating since 19th March 2013. In this paper, we describe the experimental results of the PLS-II top-up operation and the improvement plan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Suppression and nonlinear excitation of parasitic modes in second harmonic gyrotrons operating in a very high order mode

In recent years, there was an active development of high-power, sub-terahertz (sub-THz) gyrotrons for numerous applications. For example, a 0.67 THz gyrotron delivering more than 200 kW with about 20% efficiency was developed. This record high efficiency was achieved because the gyrotron operated in a high-order TE{sub 31,8}-mode with the power of ohmic losses less than 10% of the power of outgoing radiation. That gyrotron operated at the fundamental cyclotron resonance, and a high magnetic field of about 27 T was created by a pulse solenoid. For numerous applications, it is beneficial to use gyrotrons at cyclotron harmonics which can operate in available cryomagnets with fields not exceeding 15 T. However, typically, the gyrotron operation at harmonics faces severe competition from parasitic modes at the fundamental resonance. In the present paper, we consider a similar 0.67 THz gyrotron designed for operation in the same TE{sub 31,8}-mode, but at the second harmonic. We focus on two nonlinear effects typical for interaction between the fundamental and second harmonic modes, viz., the mode suppression and the nonlinear excitation of the mode at the fundamental harmonic by the second harmonic oscillations. Our study includes both the analytical theory and numerical simulations performed with the self-consistent code MAGY. The simulations show that stable second harmonic operation in the TE{sub 31,8} mode is possible with only modest sacrifice of efficiency and power.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Steady state plasma operation in RF dominated regimes on EAST

Significant progress has recently been made on EAST in the 2014 campaign, including the enhanced CW H&CD system over 20MW heating power (LHCD, ICRH and NBI), more than 70 diagnostics, ITER-like W-monoblock on upper divertor, two inner cryo-pumps and RMP coils, enabling EAST to investigate long pulse H mode operation with dominant electron heating and low torque to address the critical issues for ITER. H-mode plasmas were achieved by new H&CD system or 4.6GHz LHCD alone for the first time. Long pulse high performance H mode has been obtained by LHCD alone up to 28s at H{sub 98}∼1.2 or by combing of ICRH and LHCD, no or small ELM was found in RF plasmas, which is essential for steady state operation in the future Tokamak. Plasma operation in low collision regimes were implemented by new 4.6GHz LHCD with core Te∼4.5keV. The non-inductive scenarios with high performance at high bootstrap current fraction have been demonstrated in RF dominated regimes for long pulse operation. Near full non-inductive CD discharges have been achieved. In addition, effective heating and decoupling method under multi-transmitter for ICRF system were developed in this campaign, etc. EAST could be in operation with over 30MW CW heating and current drive power (LHCD ICRH NBI and ECRH), enhanced diagnostic capabilities and full actively-cooled metal wall from 2015. It will therefore allow to access new confinement regimes and to extend these regimes towards to steady state operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A multi-scale cognitive interaction model of instrument operations at the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is the world’s first x-ray free electron laser. It is a scientific user facility operated by the SLAC National Accelerator Laboratory, at Stanford, for the U.S. Department of Energy. As beam time at LCLS is extremely valuable and limited, experimental efficiency—getting the most high quality data in the least time—is critical. Our overall project employs cognitive engineering methodologies with the goal of improving experimental efficiency and increasing scientific productivity at LCLS by refining experimental interfaces and workflows, simplifying tasks, reducing errors, and improving operator safety and stress. Here, in this study, we describe a multi-agent, multi-scale computational cognitive interaction model of instrument operations at LCLS. Our model simulates the aspects of human cognition at multiple cognitive and temporal scales, ranging from seconds to hours, and among agents playing multiple roles, including instrument operator, real time data analyst, and experiment manager. The model can roughly predict impacts stemming from proposed changes to operational interfaces and workflows. Example results demonstrate the model’s potential in guiding modifications to improve operational efficiency. We discuss the implications of our effort for cognitive engineering in complex experimental settings and outline future directions for research. The model is open source, and the videos of the supplementary material provide extensive detail.

47 OTHER INSTRUMENTATION↗

Hydroacoustic Assessment of Behavioral Responses by Fish Passing Near an Operating Tidal Turbine in the East River, New York

An important environmental issue facing the marine and hydrokinetic energy industry is whether fish that encounter underwater energy devices are likely to be struck and injured by moving components, primarily rotating turbine blades. The automated analysis of nearly 3 weeks of multibeam hydroacoustics data identified about 35,000 tracks of fish passing a tidal turbine in the East River, New York. These tracks included both individual fish and schools during periods with the turbine absent, the turbine present and operating, and the turbine present but not operating. The density of fish in the sampled area when the turbine was absent was roughly twice the density observed when the turbine was in place, particularly when the turbine was operating. This suggests that some avoidance occurred before fish were close enough to the turbine to be observed by the hydroacoustics system. Various measures of swimming behavior (direction, velocity, and linearity) were calculated for each track and evaluated for indication of behavioral responses to turbine presence and operation. Fish tracks were grouped based on tidal cycle, current velocity, and swimming direction and were evaluated with respect to turbine presence and operation and with respect to distance from the turbine. Nonparametric tests (Kolmogorov–Smirnov test) and multivariate analysis (canonical discriminant analysis) found significant differences among groups with respect to turbine presence and operation, suggesting that some fish responded to the turbine by adjusting swimming behavior, such as making small adjustments to swimming direction and velocity as they passed near the turbine. We found no evidence that fish were being struck by rotating blades, but there did appear to be large-scale avoidance initiated out of the range of the hydroacoustics detection system. Furthermore, more study is needed to determine whether such avoidance behavior has significant ramifications for normal fish movement patterns, bioenergetics, seasonal migrations, and predator exposure.

13 HYDRO ENERGY↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 1: Particulate and gaseous emissions

This study investigated how heat demand and fuel loading affect the emissions from outdoor wood-fired hydronic heaters by testing two such appliances using an integrated-duty cycle test method. This test included transient operating conditions, such as cold and hot-starts and modulation between 15 and 100% of maximum rated output. Emission values indicate transient operating conditions produce higher emissions than steady state operation. Cold starts resulted in elevated particulate matter emission factors for both appliances; in one case the particulate matter emission factor for this period was >3500 mg/MJ, which represented emissions 20 times the average value. Additionally, when heat demand was cycled—elevated CO emission factors were measured, with values >5000 mg/MJ for both appliances and more than 3 times the appliance averages, respectively. It follows that the appliance average particulate matter emission factors and CO emission factors were not representative of the actual EF values during these transient periods. In contrast, methane emission factors were relatively stable throughout all tested combustion conditions; however, they were much higher than oil-fired appliances are therefore should not be ignored. These findings demonstrate that wood-fired hydronic heater emissions during transient operating conditions can be significantly greater than emissions during steady-state test conditions, such as those used in typical certification tests. Consequently, certification test values for particulate matter and CO emission factors may significantly underestimate the actual emissions of these appliances when operated in a home. Use of integrated duty-cycle test protocols that capture cold-starts and reloading are better for representing in-use operations of wood-fired hydronic heaters and provide more realistic emissions and delivered efficiency measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of nonlinear control performance of air handling units under variable operation conditions using root distribution approach

The control systems at Air handling units (AHUs) have nonlinear nature, resulting potentially in sluggish, aggressive, or oscillatory responses under variable operation conditions. This paper is to develop an approach for evaluating the nonlinear control performance of AHUs under variable operation conditions and for identifying the impact of varying multiple operation parameters which guides controller design. To do so, an operation parameter-based root distribution technique, intended to sketch the paths traced by closed-loop poles as multiple operation parameters are varied, is first introduced. The technique—which may be viewed as an extension of conventional, single-variable root locus—is then applied to a fan speed control system that includes a motor with a variable frequency drive and a supply fan with an air duct under variable fan speed and duct static pressure. Using the technique, the system’s stability region is graphically identified. The system is also found to be aggressive and gradually lose its stability as the fan speed decreases and the duct static pressure increases, which is validated by the field tests. Here, the root distribution approach is an effective tool to evaluate the performance of any nonlinear control systems at AHUs with multiple variable operation parameters without requiring time-domain simulations.

42 ENGINEERING↗

Memory cell operation based on small Josephson junctions arrays

Here in this article we analyze a cryogenic memory cell circuit based on a small coupled array of Josephson junctions. All the basic memory operations (e.g., write, read, and reset) are implemented on the same circuit and different junctions in the array can in principle be utilized for these operations. The presented memory operation paradigm is fundamentally different from conventional single quantum flux operation logics (SFQ). As an example, we demonstrate memory operation driven by a SFQ pulse employing an inductively coupled array of three Josephson junctions. We have chosen realistic Josephson junction parameters based on state-of-the-art fabrication capabilities and have calculated access times and access energies for basic memory cell operations. We also implemented an optimization procedure based on the simulated annealing algorithm to calculate the optimized and typical values of access times and access energies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of ITER non-activation phase operation scenarios

Non-activation phase operations in ITER in hydrogen (H) and helium (He) will be important for commissioning of tokamak systems, such as diagnostics, heating and current drive (HCD) systems, coils and plasma control systems, and for validation of techniques necessary for establishing operations in DT. The assessment of feasible HCD schemes at various toroidal fields (2.65–5.3 T) has revealed that the previously applied assumptions need to be refined for the ITER non-activation phase H/He operations. A study of the ranges of plasma density and profile shape using the JINTRAC suite of codes has indicated that the hydrogen pellet fuelling into He plasmas should be utilized taking the optimization of IC power absorption, neutral beam shine-through density limit and H-mode access into account. The EPED1 estimation of the edge pedestal parameters has been extended to various H operation conditions, and the combined EPED1 and SOLPS estimation has provided guidance for modelling the edge pedestal in H/He operations. The availability of ITER HCD schemes, ranges of achievable plasma density and profile shape, and estimation of the edge pedestal parameters for H/He plasmas have been integrated into various time-dependent tokamak discharge simulations. In this paper, various H/He scenarios at a wide range of plasma current (7.5–15 MA) and field (2.65–5.3 T) have been developed for the ITER non-activation phase operation, and the sensitivity of the developed scenarios to the used assumptions has been investigated to provide guidance for further development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long plasma duration operation analyses with an international multi-machine (tokamaks and stellarators) database

Combined high-fusion performance and long-pulse operation is one of the key integration challenges for fusion energy development in magnetic devices. Addressing these challenges requires an integrated vision of physics and engineering aspects with the purpose of simultaneously increasing time duration and fusion performance. Significant progress has been made in tokamaks and stellarators, including very recent achievement in duration and/or performance. This progress is reviewed by analyzing the experimental data (109 plasma pulses with a total of 3200 data points, i.e. on average 29 data per pulse) provided by ten tokamaks (in alphabetical order: Axially Symmetric Divertor Experiment Upgrade, DIII-D, Experimental Advanced Superconducting Tokamak, Joint European Torus, JT-60 Upgrade, Korea Superconducting Tokamak Advanced Research, tokamak à configuration variable, Tokamak Fusion Test Reactor, Tore Supra, W Environment in Steady-State Tokamak) and two stellarators (Large Helical Device and Wendelstein 7-X) expanding the pioneering work of Kikuchi (Kikuchi M. and Azumi M. 2015 Frontiers in Fusion Research II: Introduction to Modern Tokamak Physics (Springer)). Data have been gathered up to January 2022 and coordination has been provided by the recently created International Energy Agency-International Atomic Energy Agency international Coordination on International Challenges on Long duration OPeration group. By exploiting the multi-machine international database, recent progress in terms of injected energies (e.g. 1730 MJ in L-mode, 425 MJ in H-mode), durations (1056 s in L-mode, 101 s in H-mode), injected powers, and sustained performance will be reviewed. Progress has been made to sustain long-pulse operation in tokamaks and stellarators with superconducting coils, actively cooled components, and/or with metallic walls. The graph of the fusion triple products as a function of duration shows a dramatic reduction of, at least two orders of magnitude when increasing the plasma duration from less than 1 s to 100 s. Indeed, long-pulse operation is usually reached in dominant electron-heating modes at reduced density (current drive optimization) but with low ion temperatures ranging from 1 to 3 keV for discharges above 100 s. Difficulties in extending the duration may arise from coupling high heating powers over long durations and the evolving plasma-wall interaction towards an unstable operational domain. Possible causes limiting the duration and critical issues to be addressed prior to ITER operation and DEMO design are reported and analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developing the hybrid scenario in DIII-D and KSTAR for W-compatible long-pulse operation

Long-pulse, high-performance operation with tungsten plasma-facing components is a crucial challenge for achieving steady-state (SS) goals in ITER and future fusion devices. This paper presents a joint international effort between the DIII-D and KSTAR tokamaks aimed at demonstrating the compatibility of the high q 95 ~ 6 hybrid scenario with a tungsten divertor and superconducting coils. A DIII-D hybrid scenario recipe is successfully tailored to KSTAR’s operational constraints, which facilitates cross-device studies. The results show successful 30 s long-pulse operation in KSTAR at a normalized beta (β N = 2.4) with a benign m/n = 4/3 mode and effective mitigation of tungsten accumulation. Despite this success, the KSTAR scenario exhibits a greater than 25% reduction in thermal confinement compared to the DIII-D reference. To investigate this discrepancy, we performed a predictive TGYRO validation study, which suggests that the difference is likely caused by a weaker temperature pedestal in the KSTAR discharge due to a higher and narrower density pedestal. In addition, such lower thermal confinement leads to higher impurity accumulation, possibly due to a change in neoclassical transport with increased inward pinch, which further degrades global confinement. We also report that stationary, long-pulse operation with sustained thermal confinement requires consistent fueling and wall conditioning. These findings highlight the importance of optimized fueling and real-time wall conditioning in achieving a high temperature pedestal and strong global confinement during stable long-pulse operation. We propose potential approaches toward fully SS, long-pulse operation, including real-time wall conditioning using an impurity dropper in KSTAR and future tokamaks.

DIII-D↗

γ 5 schemes and the interplay of SMEFT operators in the Higgs-gluon coupling

We calculate the four-top-quark operator contributions to Higgs production via gluon fusion in the Standard Model effective field theory. The four-top operators enter for the first time via two-loop diagrams. Owing to their chiral structure they contain γ 5 , so special care needs to be taken when using dimensional regularization for the loop integrals. We use two different schemes for the continuation of γ 5 to D space-time dimensions in our calculations and present a mapping for the parameters in the two schemes. This generically leads to an interplay of different operators, such as four-top operators, chromomagnetic operators, or Yukawa-type operators at the loop level. We validate our results by examples of matching onto UV models. Published by the American Physical Society 2024

Di Noi, Stefano (ORCID:0000000211404073)↗

Quantum Simulation of Open Quantum Systems Using a Unitary Decomposition of Operators

Electron transport in realistic physical and chemical systems often involves the nontrivial exchange of energy with a large environment, requiring the definition and treatment of open quantum systems. Because the time evolution of an open quantum system employs a nonunitary operator, the simulation of open quantum systems presents a challenge for universal quantum computers constructed from only unitary operators or gates. Here, we present a general algorithm for implementing the action of any nonunitary operator on an arbitrary state on a quantum device. We show that any quantum operator can be exactly decomposed as a linear combination of at most four unitary operators. We demonstrate this method on a two-level system in both zero and finite temperature amplitude damping channels. Furthermore, the results are in agreement with classical calculations, showing promise in simulating nonunitary operations on intermediate-term and future quantum devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

Global Experiences with HPC Operational Data Measurement, Collection and Analysis

As we move into the exascale era, supercomputers grow larger, denser, more heterogeneous, and ever more complex. Operating such machines reliably and efficiently requires deep insight into the operational parameters of the machine itself as well as its supporting infrastructure. To fulfill this need, early adopter sites have started the development and deployment of Operational Data Analytics (ODA) frameworks allowing the continuous monitoring, archiving, and analysis of near realtime performance data from the machine and infrastructure levels, providing immediately actionable information for multiple operational uses. To understand their ODA goals, requirements, and use cases, we have conducted a survey among eight early adopter sites from the US, Europe, and Japan that operate top 50 high-performance computing systems. We have assessed the technologies leveraged to build their ODA frameworks, identified use cases and other push and pull factors that drive the sites' ODA activities, and report on their operational lessons.

Ott, Michael↗

Inverter Controls for Smooth Transition Operation and Voltage Balancing of Networked Microgrids

With increasing penetrations of distributed energy resources (DERs), researchers have extensively studied the formation and networking of microgrids to improve reliability during distribution system outages. However, these operations might require DERs in the microgrids to switch between grid-following (GFL) and grid-forming (GFM) modes of operation. A smooth transition between the operation modes should be ensured to have a stable system operation and to avoid nuisance tripping. Additionally, as we network microgrids, inverter control schemes with voltage-balancing controls are needed for unbalanced distribution networks. This paper presents the design of a GFM and GFL capable inverter control scheme for reliable operation in networked microgrids with mechanisms for 1) smooth transition between the GFL and GFM modes, and 2) negative sequence voltage control for voltage balancing. Using electromagnetic transient (EMT) simulations, the control scheme is first tested on a simple two-source power system using a digital real-time simulator. Next, a real-world distribution feeder with unbalanced loading and multiple DERs is used to demonstrate stable operation during the networking of microgrids with voltage balance support.

distributed energy resources↗

Intelligent Hierarchical Resilient Operation of Distribution Systems: Implementation and Validation in a Power Hardware-in-the-Loop Simulation Testbed

This paper reports on the structure of a power hardware-in-the-loop (PHIL) simulation testbed that implements, tests, and validates a novel AI-based hierarchical resilient operation model for distribution systems. The testbed implements the central and distributed controllers of the hierarchical resilient operation model and integrates a Digital Real-Time Simulator (DRTS), protective relays, a Real-Time Automation Controller (RTAC), a Software Defined Network (SDN) switch, and a battery energy storage (BES) system. The testbed provides comprehensive real-time visualization and monitoring capability as an advanced situational awareness and operator interface solution. The IEEE 33-node system is used as a test case to test and validate the operation of the model in normal operation and recovery operation after major outages in a fully automated fashion.

Ganjkhani, Mehdi↗

A Non-Exhaustive Search Algorithm to Identify Distribution Grid Operational Topology

Distribution grid, in general, is constructionally loopy but a radially operated network. Opening and closing of suitable tie-switches allow transition from one topology to another. Identifying the operational topology of a distribution system is essential for accurate control actions. This paper proposes a non-exhaustive search approach to detect the operational topology of the distribution feeder by estimating the switch statuses. In this work, a mixed-integer linear programming approach is proposed that finds the correct operational topology by identifying the system load demand and power flow variables that are closest to the corresponding measured values. The problem is constrained by distribution power flow and radial structure of the feeder. This formulation allows the inclusion of errors in power/line flow measurements making it more suitable for a practical distribution system. The proposed approach finds the correct operational topology without exhaustively searching for all possible topologies. We thoroughly validate the accuracy and effectiveness of the proposed approach in identifying correct operational topology using IEEE 123-node feeder with the help of numerous simulations studies. It is observed that the approach performs well even at very high percentages of load and flow measurement errors.

Missed detection ratio (MDR), Mixed-integer linear↗

An Analysis of Grid Operator Survey Responses: Inexperience, Workload and Fatigue in the Control Room

Although a wide array of tools and technologies have been developed over the last decade to support power grid operators, deployment of these tools has been less successful. One reason for unsuccessful deployment may be an inadequate understanding of the factors that contribute to operator error in the control room. An analysis of operators’ current vulnerabilities may provide the baseline understanding needed to inform new technology integration. In an attempt to learn more about these vulnerabilities and their perceived impact on human error we collected and analyzed survey data from 20 electric grid control room operators. We asked survey respondents to consider the various operator, technology and interaction vulnerabilities that may arise during work in the control room and record their attitudes and experiences toward each. Results suggest operator inexperience, high mental workload and fatigue are the most common vulnerabilities experienced during a shift. Survey results were analyzed to explore these vulnerabilities in greater depth.

Inexperience, Workload, Fatigue↗