Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ambient temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Atmospheric effects on inlets for supersonic cruise aircraft

Time response effects of atmospheric-type disturbances on inlets and some implications regarding inlet controls are considered. A study involving the simulation of a mixed-compression inlet is described. The study employs a linear dynamic analysis, modified for a significant nonlinearity. Transient disturbances in ambient temperature and pressure and wind gusts are considered independently at the inlet cruise Mach number of 2.5. The presented results show the maximum amplitude of a triangular-wave disturbance, that does not cause inlet unstart, as a function of disturbance pulse width.

Cole, G. L.↗

Antarctic topography from balloons

A description is presented of an investigation involving the collection of Antarctic ice sheet surface topography data by means of balloons, floating at an altitude of about 12.5 km, which traversed the Antarctic during its 1975 summer. These balloons were part of 411 constant density balloons launched in the Southern Hemisphere during the Tropical Wind, Energy conversion and Reference Level Experiment. The three sensors carried by each balloon included a radio altimeter, a pressure sensor, and an ambient temperature sensor. Data transmitted by a balloon are received by a measuring system on board the Nimbus-6 satellite. A synoptic map is presented of the 150 mbar pressure surface at 1200 GMT, December 11, 1975.

Levanon, N.↗

Atmospheric effects on inlets for supersonic cruise aircraft

Mixed-compression inlet dynamic behavior in the vicinity of unstart, was simulated and analyzed to investigate time response of an inlet's normal shock to independent disturbances in ambient temperature and pressure and relative velocity (longitudinal gust), with and without inlet controls active. The results indicate that atmospheric disturbances may be more important than internal disturbances in setting inlet controls requirements because they are usually not anticipated and because normal shock response to rapid atmospheric disturbances is not attenuated by the inlet, as it is for engine induced disturbances. However, before inlet control requirements can be fully assessed, more statistics on extreme atmospheric disturbances are needed.

Cole, G. L.↗

Experimental evaluation of the tensor polynomial criterion for designing composite structures

A comprehensive experimental and analytical evaluation of the tensor polynomial failure criterion was undertaken to determine its capability for predicting the ultimate strength of a composite limina subject to a plane stress state. Results are presented demonstrating that a quadratic formulation is too conservative and a cubic representation is required. Strength comparisons with test data derived from glass/epoxy and graphite/epoxy tubular specimens are also provided to validate the cubic strength criterion. Environmental effects including ambient temperature, exposure to vacuum, length of post-cure time, and rate of cool down were also investigated. Behavior changes associated with polymer (epoxy) matrix composites were determined in terms of variations in stiffness and tensile strength.

Tennyson, R. C.↗

Anion exchange membranes for electrochemical oxidation-reduction energy storage system

Oxidation-reduction couples in concentrated solutions separated by appropriate ion selective membranes were considered as an attractive approach to bulk electrical energy storage. A key problem is the development of the membrane. Several promising types of anionic membranes are discussed which were developed and evaluated for redox energy storage systems. The copolymers of ethyleneglycoldimethacrylate with either 2-vinylpyridine or vinylbenzl chloride gave stable resistance values compared to the copolymer of vinylbenzlchloride and divinylbenzene which served as the baseline membrane. A polyvinylchloride film aminated with tetraethylenepentamine had a low resistance but a high ion transfer rate. A slurry coated vinylpyridine had the lowest ion transfer rate. All these membranes functioned well in laboratory cells at ambient temperatures with the acidic chloride oxidant/reductant system, Fe 3, Fe 2/Ti 3, Ti 4.

Odonnell, P. M.↗

An evaluation of grease type ball bearing lubricants operating in various environments

Because many future spacecraft or space stations will require mechanisms to operate for long periods of time in environments which are adverse to most bearing lubricants, a series of tests is continuing to evaluate 29 grease type lubricants in R-4 size bearings in five different environments for a 1 year period. Four repetitions of each test are made to provide statistical samples. These tests have also been used to select four lubricants for 5 year tests in selected environments with five repetitions of each test for statistical samples. At the present time, 65 test sets have been completed and 23 test sets are underway. Two (5 year) tests have already been started in (1) continuous operation and (2) start-stop operation, with both in vacuum at ambient temperatures. To date, in the 1 year tests, the best results in all environments have been obtained with a high viscosity index perfluoroalkylpolyether grease.

Mcmurtrey, E. L.↗

Preliminary evaluation of Glass Resin materials for solar cell cover use

The glass resins were deposited by several techniques on 200 micron thick cells and on 50 microns thick wafers. The covered cells were exposed to ultraviolet light in vacuum to an intensity of 10 UV energy-equivalent solar constants at air mass zero for 728 hr. The exposure was followed by a single long thermal cycle from ambient temperature to -150 C. Visual inspection of the samples indicated that all samples had darkened to varying degrees. The loss in short-circuit current was found to range from 8 to 24%, depending on the resin formulation. In another test over 40 glass resin-coated silicon wafers withstood 15 thermal cycles from 100 to-196 C in one or more of the thicknesses tested. Several of the resin-coated wafers were tested at 65 C and 90% relative humidity for 170 hr. No change in physical appearance was detected.

Marsik, S. J.↗

The correlation of sodium and potassium metabolism with the level of energy consumption in man during adaptation to heat

The sodium and potassium metabolism was studied in a thermal chamber at 35 deg and 80 percent relative humidity in 8 men for a period of 6 days. The control group (3 subjects) were outside of the chamber at a comfortable ambient temperature. The intracellular sodium and potassium metabolism were assessed based on their content in the erythrocytes. The finding was that during adaptation to heat, a considerable amount of sodium was excreted by the body in the sweat and urine (about 1/3 of the sodium content of the human body) as compared with its intake and the amount of potassium retained in the body. Changes in the concentration of sodium and potassium may serve as indexes of the state of adaptation processes during constant exposure to heat.

Afanasyev, B. G.↗

Auto-ignition of hydrazine by engineering materials

Hydrazine, being a monopropellant, can explode and/or detonate in contact with some materials. This has been generally recognized and minimized by testing the compatibility of engineering materials with hydrazine at ambient temperature. Very limited tests have been done at elevated temperatures. To assess the potential hazard of hydrazine leakage into a propulsion compartment (boattail), autoignition characteristics of hydrazine were tested on 18 engineering materials and coatings at temperatures of 120 C to over 330 C. Furthermore, since hydrazine can decompose violently in nitrogen or helium, common purging cannot assure safety. Therefore tests were also made in nitrogen. Detonations occurred on contact with five materials in air. Similar tests in nitrogen did not lead to ignition.

Perkins, J. H.↗

Thermoregulation is impaired in an environment without circadian time cues

Thirteen adult male squirrel monkeys were restrained to a metabolism chair for periods of two or more weeks within an isolation chamber having controlled environmental lighting and ambient temperature. The monkeys were subjected to mild 6-hour cold exposures at all circadian phases of the day. It was found that a prominent circadian rhythm in body temperature, regulated against mild cold exposure, was present in those monkeys synchronized in a 24-hour light-dark cycle. Cold exposures were found to produce decreased core body temperatures when the circadian rhythms were free running or when environmental time indicators were not present. It is concluded that the thermoregulating system depends on the internal synchronization of the circadian time-keeping system.

Fuller, C. A.↗

Influence of high pressure hydrogen on cyclic load crack growth in metals

The effect of high pressure hydrogen on the crack growth rate of various nickel-base alloys was studied at ambient temperature. Considerable enhancement of the cyclic flaw growth rate was observed for Inconel 718, wrought and cast, and Waspaloy, a nickel-base alloy similar to Inconel 718. Only slight enhancement of the flaw growth rate for Alloy 903 was observed.

Jewett, R. P.↗

A multiple pulse zero crossing NMR technique, and its application to F-19 chemical shift measurements in solids

A simple multiple-pulse 'zero crossing technique' for accurately determining the first moment of a solid-state NMR spectrum is introduced. This technique was applied to obtain the F-19 chemical shift versus pressure curves up to 5 kbar for single crystals of CaF2 (0.29 + or - 0.02 ppm/kbar) and BaF2 (0.62 + or - 0.05 ppm/kbar). Results at ambient temperature and pressure are also reported for a number of other fluorine compounds. Because of its high data rate, this technique is potentially several orders of magnitude more sensitive than similar CW methods.

Burum, D. P.↗

Primary lithium battery technology and its application to NASA missions

A description is given of the components, overall cell reactions, and performance characteristics of promising new ambient temperature lithium primary systems based on the Li-V205, Li-SO2, and Li-SOC12 couples. Development status of these systems is described in regard to availability and uncertainties in the areas of safety and selected performance characteristics. Studies show that use of lithium batteries would enhance a variety of missions and applications by decreasing power sytems weight and thereby increasing payload weight. In addition, the lithium batteries could enhance cost effectiveness of the missions.

Frank, H. A.↗

Full-coverage film cooling: 3-dimensional measurements of turbulence structure and prediction of recovery region hydrodynamics

Hydrodynamic measurements were made with a triaxial hot-wire in the full-coverage region and the recovery region following an array of injection holes inclined downstream, at 30 degrees to the surface. The data were taken under isothermal conditions at ambient temperature and pressure for two blowing ratios: M = 0.9 and M = 0.4. Profiles of the three main velocity components and the six Reynolds stresses were obtained at several spanwise positions at each of the five locations down the test plate. A one-equation model of turbulence (using turbulent kinetic energy with an algebraic mixing length) was used in a two-dimensional computer program to predict the mean velocity and turbulent kinetic energy profiles in the recovery region. A new real-time hotwire scheme was developed to make measurements in the three-dimensional turbulent boundary layer over the full-coverage surface.

Yavuzkurt, S.↗

Area scaling investigations of charging phenomena

The charging and discharging behavior of square, planar samples of silvered, fluorinated ethylene-propylene (FEP) Teflon thermal control tape was measured. The equilibrium voltage profiles scaled with the width of the sample. A wide range of discharge pulse characteristics was observed, and the area dependences of the peak current, charge, and pulse widths are described. The observed scaling of the peak currents with area was weaker than that previously reported. The discharge parameters were observed to depend strongly on the grounding impedance and the beam voltage. Preliminary results suggest that measuring only the return-current-pulse characteristics is not adequate to describe the spacecraft discharging behavior of this material. The seams between strips of tape appear to play a fundamental role in determining the discharging behavior. An approximate propagation velocity for the charge cleanoff was extracted from the data. The samples - 232, 1265, and 5058 square centimeters in area - were exposed at ambient temperature to a 1- to 2-nA/sq cm electron beam at energies of 10, 15, and 20 kilovolts in a 19-meter-long by 4.6-meter-diameter simulation facility at the Lewis Research Center.

Aron, P. R.↗

HEAP: Heat Energy Analysis Program, a computer model simulating solar receivers

A computer program which can distinguish between different receiver designs, and predict transient performance under variable solar flux, or ambient temperatures, etc. has a basic structure that fits a general heat transfer problem, but with specific features that are custom-made for solar receivers. The code is written in MBASIC computer language. The methodology followed in solving the heat transfer problem is explained. A program flow chart, an explanation of input and output tables, and an example of the simulation of a cavity-type solar receiver are included.

Lansing, F. L.↗

A transmission line phase stabilizer

To meet the phase stability requirements of certain experiments performed with the Deep Space Network, transmission lines carrying reference signals must be stabilized to reduce changes in their electrical length due to mechanical movement or changes in ambient temperature. A transmission line phase stabilizer being developed at JPL to perform this function is described.

Lutes, G. F.↗

Electrical Characterization of Hughes HCMP 1853D and RCA CDP1853D N-bit, CMOS, 1-of-8 Decoder Microcircuits

Electrical characterization tests were performed on two different manufactured types of integrated circuits. The devices were subjected to functional and AC and DC parametric tests at ambient temperatures of -55 C, -20 C, 25 C, 85 C, and 125 C. The data were analyzed and tabulated to show the effect of operating conditions on performance and to indicate parameter deviations among devices in each group. Accuracy was given precedence over test time efficiency where practical, and tests were designed to measure worst case performance.

Stokes, R. L.↗