Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerated beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Bunch Shaping in Electron Linear Accelerators

Modern electron linear accelerators are often designed to produce smooth bunch distributions characterized by their macroscopic ensemble-average moments. However, an increasing number of accelerator applications call for finer control over the beam distribution, such as by requiring specific shapes for its projection along one coordinate. Ultimately, the control of the beam distribution at the single-particle level could enable new opportunities in accelerator science. This review discusses the recent progress toward controlling electron beam distributions on the “mesoscopic” scale with an emphasis on shaping the beam or introducing complex correlations required for some applications. This review emphasizes experimental and theoretical developments of electron-bunch shaping methods based on bounded external electromagnetic fields or via interactions with the self-generated velocity and radiation fields.

Ha, G.↗

O(+) acceleration due to resistive momentum transfer in the auroral field line plasma

An analytical model is defined to demonstrate that parallel acceleration of an O(+) ion beam in the ionosphere can occur naturally due to the presence of a quasi-static parallel electric field. Momentum equations are defined for friction between hydrogen ions and electrons, which produces a quasi-static electric field. The field can accelerate ions, e.g., the O(+) ions, which do not participate in the frictional momentum exchange. The conditions are shown to be applicable to the auroral field line plasma if a current is present along the magnetic field. A simulation performed with the equations shows that the field line plasma exhibits dynamic behavior after a field-aligned current appears. The resulting momentum gain by O(+) ions can be sufficient for causing a potential drop of several kilovolts along the field line.

Mitchell, H. G., Jr.↗

Advanced focusing system for secondary electrons in a bunch shape monitor

Non-destructive measurements of longitudinal beam profile in non-relativistic hadron accelerators are usually performed with Bunch Shape Monitors that utilize secondary electron emission to reproduce the shape of a primary ion beam. The existing devices, however, have poor electron collection efficiency from the wire and are limited to one dimensional measurements of the phase coordinate. Here, we present the development of a bunch shape monitor with improved performance for proton beams to be used in the Spallation Neutron Source accelerator. This improvement was achieved by adding focusing optics between the wire and the entrance slit, which will also allow measurements over a much higher dynamic range. Here we present the design, simulation and experimental test results of the developed new electron beam guidance system for the existing SNS bunch shape monitor that allowed significant improvement in the collection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration Development and Testing of Rear Transition Monitor for Beam Current Monitoring System

Addressing baseline effects in accelerator environments is crucial for accurate data acquisition and analysis, since baseline effects can obscure signal clarity and impact the reliability of beam current monitoring systems. There are many potential contributors to baseline noise, such as variations in beam dynamics, electromagnetic interference from nearby equipment, or RF interference. Previous applications of noise reduction systems don t sufficiently filter sources of asynchronous noise, so a new algorithm was implemented. A simulation dataset was created to replicate beam conditions and a Red Pitaya FPGA was used to collect data through the streaming application. A Python script was developed to implement noise reduction algorithms and efforts were made to integrate real-time data streaming with the Redis platform and Acnet Front End infrastructure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doses and fluxes in the proton-irradiated Big Target: A MARS15 analysis

This work is aimed at determination of secondary particle fluxes, prompt and residual doses as well as energy deposition in and around the Big Target, a 20-tonnes cylindrical target made of natural uranium with the lead core and a stainless-steel yoke, which is being considered to be irradiated by a 0.16-μA 600-MeV proton beam of the JINR Phasotron accelerator. The simulations were performed with the use of the MARS15 particle transport code employing the LAQGSM and CEM generators and based on the ENDFB-VIII neutron cross section library. The calculations for 12-hour, 100-hour, and 3-day irradiations with the aforementioned conditions indicate that temperature rise due to the beam does not require target cooling, the target can be safely handled soon after the end of irradiation, and its decommissioning is possible three years past the irradiation. Doses

43 PARTICLE ACCELERATORS↗

Development of a Platform at the Matter in Extreme Conditions End Station for Characterization of Matter Heated by Intense Laser-Accelerated Protons

High intensity short-pulse lasers have made possible the generation of energetic proton beams, unlocking numerous applications in high energy density science. One such application is uniform and isochoric heating of materials to the warm dense matter (WDM) state. We have developed a new experimental platform to simultaneously create and probe warm dense matter at the Matter in Extreme Conditions (MEC) end station at the Linac Coherent Light Source (LCLS). The short pulse optical laser (delivering up to 1 J in 45 fs) and the ultra-bright LCLS x-ray laser with tunable frequency respectively deliver high power required to heat materials to WDM and precision-timed high-resolution x-rays to probe them. The laser-accelerated proton beam driven from a flat 1.5 μm Cu foil was first measured then directed to a secondary sample of Al or polypropylene, typically 300-400 μm away. The time evolution of the sample electron temperature was measured using streaked optical pyrometry, where we observed a peak temperature of 0.9 0.15 eV on the rear surface of an Al sample heated by the proton beam. Here, the simulations using the hybrid-PIC code LSP and the rad-hydro code HELIOS show that a measured proton beam can heat Al to approximately 4 eV and polypropylene to 1 eV if instead focused by a hemispherical Cu target. Through additional LSP simulations, we anticipate creating hotter warm dense matter states (20 eV) by increasing the laser energy to 10 J and keeping the other laser parameters fixed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron Cooling in NICA Acceleration Complex

The Nuclotron-based Ion Collider fAcility (NICA) is under assembling at JINR. NICA will provide colliding beams for study of hot strongly interacting baryonic matter and spin physics. The NICA injection complex includes a tandem of 2 superconducting synchrotrons: Booster (up to 600 MeV/u) and Nuclotron (up 3.9 GeV/u fully stripped heavy ions). Since the start of injection complex commissioning in 2020 its four Runs were carried out. To the present time the beams of He, Fe, C and Xe were accelerated. Booster electron cooling was first used for cooling of continuous Fe¹⁴⁺ beam at the energy of 3.2 MeV/u in Run II. In the last Run we demonstrated longitudinal cooling of Xe²⁸⁺ in the presence of RF voltage at the Booster injection energy. This regime is required for accumulation in Booster the intensity required for Collider operation. The cooling enabled a 2 times intensity increase of slow extracted beam from Nuclotron. Optimization of Booster electron cooling for beam accumulation will be carried out in the next Run. Another (high voltage) electron cooling system will be used in the NICA Collider rings for ion accumulation in a barrier bucket and consecutive bunch formation.

43 PARTICLE ACCELERATORS↗

Reliability assessment of multiple quantum well avalanche photodiodes

The reliability of doped-barrier AlGaAs/GsAs multi-quantum well avalanche photodiodes fabricated by molecular beam epitaxy is investigated via accelerated life tests. Dark current and breakdown voltage were the parameters monitored. The activation energy of the degradation mechanism and median device lifetime were determined. Device failure probability as a function of time was computed using the lognormal model. Analysis using the electron beam induced current method revealed the degradation to be caused by ionic impurities or contamination in the passivation layer.

Yun, Ilgu↗

Acceleration, radiation and precession in SS 433

Some theoretical problems posed by the observations of SS 433 are considered. The monoenergetic beams point toward a gas-dynamic acceleration process. In this model the collimation implies that the acceleration occurs in a region of slab symmetry, possibly the surface layers of an accretion disk. The 164 day rotation of the beam pattern may be explained as a precession period.

Katz, J. I.↗

Strategy for Modernizing a 40-Year-Old Accelerator Control System

Modernizing the Fermilab accelerator control system is essential to future operations of the laboratory's accelerator complex. The existing control system has evolved over four decades and uses hardware that is no longer available and software that uses obsolete frameworks. The Accelerator Controls Operations Research Network (ACORN) Project will modernize the control system and replace end-of-life power supplies to enable future accelerator complex operations with megawatt particle beams. The project team is evaluating three design concepts, and the future deployment of artificial intelligence capabilities for accelerator operations is an important consideration. An overview of the ACORN Project will be presented, including R&D used for evaluating the conceptual designs in the context of requirements for future accelerator operations.

43 PARTICLE ACCELERATORS↗

Method of cold welding using ion beam technology

A method for cold welding metal joints is described. In order to remove the contamination layer on the surface of the metal, an ion beam generator is used in a vacuum environment. A gas, such as xenon or argon, is ionized and accelerated toward the metal surface. The beam of gas effectively sputters away the surface oxides and contamination layer so that clean underlying metal is exposed in the area to be welded. The use of this method allows cold welding with minimal deformation. Both similar and dissimilar metals can be cold welded with this method.

Sater, B. L.↗

Atomic References for Measuring Small Accelerations

Accelerometer systems that would combine the best features of both conventional (e.g., mechanical) accelerometers and atom interferometer accelerometers (AIAs) have been proposed. These systems are intended mainly for use in scientific research aboard spacecraft but may also be useful on Earth in special military, geological, and civil-engineering applications. Conventional accelerometers can be sensitive, can have high dynamic range, and can have high frequency response, but they lack accuracy and long-term stability. AIAs have low frequency response, but they offer high sensitivity, and high accuracy for measuring small accelerations. In a system according to the proposal, a conventional accelerometer would be used to perform short-term measurements of higher-frequency components of acceleration, while an AIA would be used to provide consistent calibration of, and correction of errors in, the measurements of the conventional accelerometer in the lower-frequency range over the long term. A brief description of an AIA is prerequisite to a meaningful description of a system according to the proposal. An AIA includes a retroreflector next to one end of a cell that contains a cold cloud of atoms in an ultrahigh vacuum. The atoms in the cloud are in free fall. The retroreflector is mounted on the object, the acceleration of which is to be measured. Raman laser beams are directed through the cell from the end opposite the retroreflector, then pass back through the cell after striking the retroreflector. The Raman laser beams together with the cold atoms measure the relative acceleration, through the readout of the AIA, between the cold atoms and the retroreflector.

Maleki, Lute↗

Human Factors Design for Particle Accelerator Control Room Interfaces

Fermilab, the birthplace of many scientific discoveries in physics and particle accelerator sciences, is in the midst of a widescale modernization effort. The Accelerator Control Operations Research Network (ACORN project’s goal is to modernize the accelerator control system by replacing end-of-life power supplies and enhance future operations of the Fermilab accelerator complex with megawatt particle beams. Within ACORN, opportunities for process improvement concerning software development, human-system interface design, and task performance are also being considered. Human factors researchers from Idaho National Laboratory in collaboration with usability experts from Fermilab, are currently investigating human-centered design improvements for the accelerator control system. For example, substantial tribal knowledge and memory recall are required to effectively operate the accelerator system. This contributes to high cognitive workload and potential burnout of accelerator operators. Developing guidance for consistent visual and functional design enables a more intuitive interaction and relieves operators of cognitive burden. Additionally, developing more intuitive and integrated interfaces can also lead to improved accelerator efficacy by empowering operators with greater understanding and control of the systems. The challenge in developing such interfaces is in designing for a wide variety of user goals, system specifications, and level of experience in users. The challenges need to be met while e also considering the maintainability of the control system. The purpose of this paper is to detail the human factors process and design within the ACORN project, describe results gathered thus far, and discuss the larger implications for this work.

43 PARTICLE ACCELERATORS↗

Collider-quality electron bunches from an all-optical plasma photoinjector

We present an approach for generating collider-quality electron bunches using a plasma photoinjector. The approach leverages recently developed techniques for the spatiotemporal control of laser pulses to produce a moving ionization front in a nonlinear plasma wave. The moving ionization front generates an electron bunch with a current profile that balances the longitudinal electric field of an electron beam-driven plasma wave, creating a uniform accelerating field across the bunch. Particle-in-cell (PIC) simulations of the ionization stage show the formation of an electron bunch with 220 pC charge and low emittance (ɛ 𝑥 = 171 nm rad, ɛ 𝑦 = 76 nm rad). Quasistatic PIC simulations of the acceleration stage show that the bunch is efficiently accelerated to 24 GeV over 2 m with a final energy spread of less than 1% and emittances of ɛ 𝑥 = 189 nm rad and ɛ 𝑦 = 80 nm rad. This high-quality electron bunch meets the requirements outlined by the Snowmass process for intermediate-energy colliders and compares favorably to the beam quality of proposed and existing accelerator facilities. The results establish the feasibility of plasma photoinjectors for future collider applications making a significant step toward the realization of high-luminosity, compact accelerators for particle physics research.

43 PARTICLE ACCELERATORS↗

R&D toward design for a pion-production target for Mu2e-II

The Mu2e experiment at Fermilab will search for evidence of charged lepton flavor violation by observing the conversion of a negative muon into an electron in the Coulomb field of a nucleus without emission of neutrinos and will probe effective new-physics mass scales in the 103-104 TeV range. One of the main parts of the Mu2e experimental setup is its target station in which negative pions are generated in interactions of the 8 GeV primary proton beam with a tungsten target, which will be capable of producing $2\times10^{17}$ negative muons per year. Mu2e can be extended by a next generation experiment, Mu2e-II, with a sensitivity improved by another factor of 10 or more as enabled by the PIP-II accelerator upgrade project. PIP-II is a 250-meter-long linac capable of accelerating a 2 mA proton beam to a kinetic energy of 800 MeV corresponding to 1.6 MW of power. To achieve another factor of ten improvement in sensitivity, Mu2e-II will require about 100 kW of proton beam on target, and the added power requires a new target design. We will present our progress in RD of a target station conceptual design for Mu2e-II, using the MARS15 and G4beamline Monte-Carlo codes toward a selection between granular, conveyor, and rotating cylindrical target options.

Lynch, Kevin Richard↗

Photon phase-space dynamics in a plasma wakefield accelerator

Frequency up-shifting of laser light in a beam-driven plasma wakefield has the potential to provide high-intensity sources of short wavelength radiation. Simulations have demonstrated that a laser pulse can undergo large frequency shifts, limited only by the drive beam energy, when the plasma density is tailored to match the accelerating phase of the wake to the group velocity of the pulse. Here, we study the dynamical evolution of photons in the 1D1P phase-space vicinity of the plasma wake-phase matching condition. Numerical calculations using a photon kinetic model are validated by direct comparison with 1D and quasi-3D particle-in-cell simulations. These calculations form the basis of a linear theory of the photon dynamics which reveals several important results, including scalings for the properties of the witness pulse and a self-similar solution for the photon phase-space dynamics. One prediction of the analytic theory is that the pulse can be compressed indefinitely, though the amount of compression would ultimately be limited by practical constraints. These results suggest that photon acceleration can provide a novel source of sub-femtosecond, short wavelength radiation.

XUV generation↗

Initial Assessment of Availability and Reliability for the PIP-II Superconducting Radio Frequency Linear Accelerator Facility

The Proton Improvement Plan -II (PIP-II) is a high intensity and high energy proton accelerator which will be used to support the neutrino program at Fermilab. The accelerator will deliver a 2 mA average beam current at a kinetic energy of 800 MeV. Due to the requirements from experiments, this accelerator is designed to be a highly reliable and available system. A target availability of the complete accelerator facility was prescribed to be 90%. An availability and reliability assessment of the accelerator was carried out to ascertain that the design can meet the target availability specification. The results were estimated for the nominal operational mode, when an 800 MeV beam is delivered on the target and for the critical operational mode, when a 600 MeV output beam was incident on the target. The design of a complete accel-erator system is a complex arrangement of a large number of components. To simplify the analysis, a few components were shortlisted and based on their functions, an accelerator model was created. The model is represented in the form of reliability block diagrams. Availability and reliability were estimated for each operational mode. To increase the availa-bility and reliability of the overall accelerator, redundancy of one cavity per section in the superconducting portion of the Linac was introduced.

43 PARTICLE ACCELERATORS↗

Funduscopic alterations in the rhesus monkey induced by exposure to heavy ions /0+8/ 250 MeV/nucleon

A heavy-ion, high-energy beam has been extracted from the Lawrence Radiation Laboratory Bevatron, making controlled exposure of biological systems feasible, and a series of experiments have been undertaken to determine the possible deleterious effects of such irradiation upon the primate retina. The left eyes of 54 rhesus monkeys have been exposed to accelerated 0+8 (250 MeV/nucleon). Beam flux ranged from 1.3 x 10 to the 7th particles/ sq cm (171 rads) to 5.9 x 10 to the 8th particles/sq cm (7740 rads). Fundus photography was performed immediately prior to and immediately following exposure, at 24 to 48 hours postexposure and at 1, 2, and 5 weeks postexposure. Punctate hemorrhages of the retina were visible at 1.3 x 10 to the 7th particles/sq cm (171 rads), the lowest exposure level utilized in this study. Acute radiation retinopathy, consisting of geographic retinal hemorrhage and ischemic necrosis of the retina, was not seen until total flux reached 7.7 x 10 to the 7th particles/sq cm (1000 rads).

Beckman, F. N.↗