Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “USED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Search for Strangeonia in Photoproduction using CLAS

The HyCLAS experiment at Jefferson Lab is a program to search for new and unusual mesons produced via photoproduction. The strangeonia sector is poorly known and a main component of this program is a search for new strangeonium states. The reaction {gamma}p{yields}p{phi}{eta} is an ideal channel to look for strangeonium states due to the strangeness content of both the {phi} and {eta}. The data was acquired at the JLAB CLAS facility using a 4-5.5 GeV tagged photon beam. The {phi} meson is identified via the K{sup +}K- decay. The recoil proton is observed in the CLAS spectrometer and the {eta} meson is identified through the missing mass. Also of interest is the search for strangeonia decaying to {phi}{pi}{sup 0} and {phi}{omega}. These channels are OZI suppressed for qq-bar mesons and an observation of a meson decaying to these channels would provide a strong evidence of mesons beyond qqa-bar. Preliminary results describing the data quality, kinematics and dynamics will be shown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of the Polarization Observables I{sup s} and I{sup c} for {gamma}{sup {yields}p{yields}}p{pi}{sup +{pi}-} using the CLAS Spectrometer

Model predictions regarding the excited baryon spectrum provided by Constituent Quark Models show good agreement with experimental measurements in the low-energy region less than {approx_equal}1.8 GeV. The mass region above {approx_equal}1.8 GeV, however, contains many resonances which are predicted to exist by these models but have not been experimentally verified. The analysis of a double meson final state using linearly polarized photoproduction data allows access to two polarization observables, I{sup s} and I{sup c}(also known as the beam asymmetry {Sigma} for a single meson final state). It has been shown that measurements of these polarizaton observables can provide insight into this missing resonance problem. This analysis was carried out on data taken from the CLAS-g8b data run period conducted at Jefferson Lab in Newport News, Virginia. The analysis of this data and preliminary measurements of these obsevables will be dicussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-resolved spectra of dense plasma focus using spectrometer, streak camera, and CCD combination

A time-resolving spectrographic instrument has been assembled with the primary components of a spectrometer, image-converting streak camera, and CCD recording camera, for the primary purpose of diagnosing highly dynamic plasmas. A collection lens defines the sampled region and couples light from the plasma into a step index, multimode fiber which leads to the spectrometer. The output spectrum is focused onto the photocathode of the streak camera, the output of which is proximity-coupled to the CCD. The spectrometer configuration is essentially Czerny-Turner, but off-the-shelf Nikon refraction lenses, rather than mirrors, are used for practicality and flexibility. Only recently assembled, the instrument requires significant refinement, but has now taken data on both bridge wire and dense plasma focus experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of self-propagating formation reactions in Ni/Zr multilayered foils using reaction heats, velocities, and temperature-time profiles

We report on intermetallic formation reactions in vapor-deposited multilayered foils of Ni/Zr with 70 nm bilayers and overall atomic ratios of Ni:Zr, 2 Ni:Zr, and 7 Ni:2 Zr. The sequence of alloy phase formation and the stored energy is evaluated at slow heating rates (~1 K/s) using differential scanning calorimetry (DSC) traces to 725ºC. All three chemistries initially form a Ni-Zr amorphous phase which crystallizes first to the intermetallic NiZr. The heat of reaction to the final phase is 34-36 kJ/mol atom for all chemistries. Intermetallic formation reactions are also studied at rapid heating rates (greater than 10 5 K/s) in high temperature, self-propagating reactions which can be ignited in these foils by an electric spark. We find that reaction velocities and maximum reaction temperatures (T max ) are largely independent of foil chemistry at 0.6 ± 0.1 m/s and 1220 ± 50 K, respectively, and that the measured T max is more than 200 K lower than predicted adiabatic temperatures (T ad ). The difference between T max and T ad is explained by the prediction that transformation to the final intermetallic phases occurs after T max and results in the release of 20-30 % of the total heat of reaction and a delay in rapid cooling.

36 MATERIALS SCIENCE↗

Measurement of Hard X-ray Lens Wavefront Aberrations using Phase Retrieval

Measuring the deviation of a wavefront from a sphere provides valuable feedback on lens alignment and manufacturing errors. We demonstrate that these aberrations can be accurately measured at hard x-ray wavelengths, from far-field intensity measurements, using phase retrieval with a moveable structure in the beam path. We induce aberrations on a hard x-ray kinoform lens through deliberate misalignment and show that the reconstructed wavefronts are in good agreement with numerical simulations. Reconstructions from independent data, with the structure at different longitudinal positions and significantly separated from the beam focus, agreed with a root mean squared error of 0.006 waves.

42 ENGINEERING↗

Oxygen-Atom Defects In 6H Silicon Carbide Implanted Using 24- MeV O{sup 3+} Ions Measured Using Three-Dimensional Positron Annihilation Spectroscopy System (3DPASS)

Three dimensional electron-positron (e{sup -}-e{sup +}) momentum distributions were measured for single crystal 6H silicon carbide (SiC); both virgin and having implanted oxygen-atom defects. 6H SiC samples were irradiated by 24- MeV O{sup 3+} ions at 20 particle-nanoamps at the Sandia National Laboratory's Ion Beam Facility. O{sup 3+} ions were implanted 10.8 {mu}m deep normal to the (0001) face of one side of the SiC samples. During positron annihilation measurements, the opposite face of the 254.0-{mu}m thick SiC samples was exposed to positrons from a {sup 22}Na source. This technique reduced the influence on the momentum measurements of vacancy-type defects resulting from knock-on damage by the O{sup 3+} ions. A three-dimensional positron annihilation spectroscopy system (3DPASS) was used to measure e{sup -}-e{sup +} momentum distributions for virgin and irradiated 6H SiC crystal both before and following annealing. 3DPASS simultaneously measures coincident Doppler-broadening (DBAR) and angular correlation of annihilation radiation (ACAR) spectra. DBAR ratio plots and 2D ACAR spectra are presented. Changes in the momentum anisotropies relative to crystal orientation observed in 2D ACAR spectra for annealed O-implanted SiC agree with the local structure of defect distortion predicted using Surface Integrated Molecular Orbital/Molecular Mechanics (SIMOMM). Oxygen atoms insert between Si and C atoms increasing their separation by 0.9 A forming a Si-O-C bond angle of {approx}150 deg.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct simulation of electron transfer using ring polymer molecular dynamics: Comparison with semiclassical instanton theory and exact quantum methods

The use of ring polymer molecular dynamics (RPMD) for the direct simulation of electron transfer (ET) reaction dynamics is analyzed in the context of Marcus theory, semiclassical instanton theory, and exact quantum dynamics approaches. For both fully atomistic and system-bath representations of condensed-phase ET, we demonstrate that RPMD accurately predicts both ET reaction rates and mechanisms throughout the normal and activationless regimes of the thermodynamic driving force. Analysis of the ensemble of reactive RPMD trajectories reveals the solvent reorganization mechanism for ET that is anticipated in the Marcus rate theory, and the accuracy of the RPMD rate calculation is understood in terms of its exact description of statistical fluctuations and its formal connection to semiclassical instanton theory for deep-tunneling processes. In the inverted regime of the thermodynamic driving force, neither RPMD nor a related formulation of semiclassical instanton theory capture the characteristic turnover in the reaction rate; comparison with exact quantum dynamics simulations reveals that these methods provide inadequate quantization of the real-time electronic-state dynamics in the inverted regime.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous sample and spatial coherence characterisation using diffractive imaging

We demonstrate an algorithm that reconstructs the complex transmission function of an object from experimental X-ray diffraction data using partially coherent 1.4 keV X-rays that does not require a priori input of the coherence function. The quality of the reconstruction is significantly better than that obtained by assuming that the illumination is fully coherent. Our approach can be readily applied to diffraction imaging problems where a model for the spatial coherence can be assumed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling of 10 GeV-1 TeV laser-plasma accelerators using Lorentz boosted simulations

Modeling of laser-plasma wakefield accelerators in an optimal frame of reference [J.-L. Vay, Phys. Rev. Lett. 98, 130405 (2007)] allows direct and efficient full-scale modeling of deeply depleted and beam loaded laser-plasma stages of 10 GeV-1 TeV (parameters not computationally accessible otherwise). This verifies the scaling of plasma accelerators to very high energies and accurately models the laser evolution and the accelerated electron beam transverse dynamics and energy spread. Over 4, 5, and 6 orders of magnitude speedup is achieved for the modeling of 10 GeV, 100 GeV, and 1 TeV class stages, respectively. Agreement at the percentage level is demonstrated between simulations using different frames of reference for a 0.1 GeV class stage. Obtaining these speedups and levels of accuracy was permitted by solutions for handling data input (in particular, particle and laser beams injection) and output in a relativistically boosted frame of reference, as well as mitigation of a high-frequency instability that otherwise limits effectiveness.

43 PARTICLE ACCELERATORS↗

A compact neutron generator using a field ionization source

Field ionization as a means to create ions for compact and rugged neutron sources is pursued. Arrays of carbon nano-fibers promise the high field-enhancement factors required for efficient field ionization. We report on the fabrication of arrays of field emitters with a density up to 10{sup 6} tips/cm{sup 2} and measure their performance characteristics using electron field emission. The critical issue of uniformity is discussed, as are efforts towards coating the nano-fibers to enhance their lifetime and surface properties.

43 PARTICLE ACCELERATORS↗

Conformal growth of Mo/Si multilayers on grating substrates using collimated ion beam sputtering

Deposition of multilayers on saw-tooth substrates is a key step in the fabrication of multilayer blazed gratings (MBG) for extreme ultraviolet and soft x-rays. Growth of the multilayers can be perturbed by shadowing effects caused by the highly corrugated surface of the substrates, which results in distortion of the multilayer stack structure and degradation of performance of MBGs. In this study, to minimize the shadowing effects, we used an ion-beamsputtering machine with a highly collimated atomic flux to deposit Mo/Si multilayers on saw-tooth substrates. The sputtering conditions were optimized by finding a balance between smoothening and roughening processes in order to minimize degradation of the groove profile in the course of deposition and at the same time to keep the interfaces of a multilayer stack smooth enough for high efficiency. An optimal value of energy of 200 eV for sputtering Kr + ions was found by deposition of test multilayers on flat substrates at a range of ion energies. Two saw-tooth substrates were deposited at energies of 200 eV and 700 eV for the sputtering ions. It was found that reduction of the ion energy improved the blazing performance of the MBG and resulted in a 40% gain in the diffraction efficiency due to better replication of the groove profile by the multilayer. As a result of the optimization performed, an absolute diffraction efficiency of 28.8% was achieved for the 2nd blaze order of the MBG with a groove density of 7350 lines/mm at a wavelength of 13.5 nm. Lastly, details of the growth behavior of the multilayers on flat and saw-tooth substrates are discussed in terms of the linear continuous model of film growth.

36 MATERIALS SCIENCE↗

Demonstration of high efficiency elastocaloric cooling with large Delta T using NiTi wires

Vapor compression (VC) is by far the most dominant technology for meeting all cooling and refrigeration needs around the world. It is a mature technology with the efficiency of modern compressors approaching the theoretical limit, but its environmental footprint remains a global problem. VC refrigerants such as hydrochloroflurocarbons (HCFCs) and hydrofluorocarbons (HFCs) are a significant source of green house gas emissions, and their global warming potential (GWP) is as high as 1000 times that of CO2 [Buildings Energy Data Book (Building Technologies Program, Department of Energy, 2009)]. There is an urgent need to develop an alternative high-efficiency cooling technology that is affordable and environmentally friendly [A. D. Little, Report For Office of Building Technology State and Community Programs, Department of Energy, 2001]. Here, we demonstrate that elastocaloric cooling (EC), a type of solid-state cooling mechanism based on the latent heat of reversible martensitic transformation, can have the coefficient of performance as high as 1 1, with a directly measured Delta T of 17 degrees C. The solid-state refrigerant of EC completely eliminates the use of any GWP refrigerants including HCFCs/HFCs. (C) 2012 American Institute. of Physics. [http://dx.doiorg/10.1063/1.4746257]

Cui, J↗

ELMy H-mode linear simulation with 3-field model on experimental advanced superconducting tokamak using BOUT++

H-mode plasmas with ELM (edge localized mode) have been realized on experimental advanced superconducting tokamak (EAST) with 2.45 GHz low hybrid wave at P{sub LHW}{approx}1 MW in 2010. Data from EAST experiments including magnetic geometry, measured pressure profiles, and calculated current profiles are used to investigate the physics of ELM utilizing the BOUT++ code. Results from linear simulations show that the ELMs in EAST are dominated by resistive ballooning modes. When the Lundquist number (dimensionless ratio of the resistive diffusion time to the Alfven time) is equal to or less than 10{sup 7}, the resistive ballooning modes are found to become unstable in the ELMy H-mode plasma. For a fixed pedestal pressure profile, increasing plasma current generates more activities of low-n ELMs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation of electron bunches with tailored current profiles using multi-frequency linacs

Tailoring an electron bunch with specific current profile can provide substantial enhancement of the transformer ratio in beam-driven acceleration methods. We present a method relying on the use of a linac with accelerating sections operating at different frequencies followed by a magnetic bunch compressor. The experimental verfification of the technique in a two-frequency linac is presented. The compatibility of the proposed technique with the formation and acceleration of a drive and witness bunches is numerically demonstrated.

43 PARTICLE ACCELERATORS↗

Note: Alignment/focus dependent core-line sensitivity for quantitative chemical analysis in hard x-ray photoelectron spectroscopy using a hemispherical electron analyzer

X-ray photoelectron spectroscopy is an established technique for quantitative chemical analysis requiring accurate peak intensity analysis. We present evidence of focus/alignment dependence of relative peak intensities for peaks over a broad kinetic energy range with a hemispherical electron analyzer operated in a position imaging mode. A decrease of over 50% in the Ag 2p{sub 3/2} to Ag 3d ratio is observed in a Ag specimen. No focus/alignment dependence is observed when using an angular imaging mode, necessitating the use of angular mode for quantitative chemical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic data of tungsten for current and future uses in fusion and plasma science

Atomic physics has played an important role throughout the history of experimental plasma physics. For example, accurate knowledge of atomic properties has been crucial for understanding the plasma energy balance and for diagnostic development. With the shift in magnetic fusion research toward high-temperature burning plasmas like those expected to be produced in the ITER tokamak, the atomic physics of tungsten has become important. Tungsten will be a constituent of ITER plasmas because of its use as a plasma-facing material able to withstand high heat loads with lower tritium retention than other possible materials. Already, ITER diagnostics are being developed based on using tungsten radiation. In particular, the ITER Core Imaging X-ray Spectrometer (CIXS), which is designed to measure the core ion temperature and bulk plasma motion, is being based on the x-ray emission of neonlike tungsten ions (W{sup 64+}). In addition, tungsten emission will at ITER be measured by extreme ultraviolet (EUV) and optical spectrometers to determine its concentration in the plasma and to assess power loss and tungsten sputtering rates. On present-day tokamaks tungsten measurements are therefore being performed in preparation of ITER. Tungsten has very complex spectra and most are still unknown. The WOLFRAM project at Livermore aims to produce data for tungsten in various spectral bands: Lshell x-ray emission for CIXS development, soft x-ray and EUV M- and N-shell tungsten emission for understanding the edge radiation from ITER plasmas as well as from contemporary tokamaks, and O-shell emission for developing spectral diagnostics of the ITER divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control of focusing forces and emittances in plasma-based accelerators using near-hollow plasma channels

A near-hollow plasma channel, where the plasma density in the channel is much less than the plasma density in the walls, is proposed to provide independent control over the focusing and accelerating forces in a plasma accelerator. In this geometry the low density in the channel contributes to the focusing forces, while the accelerating fields are determined by the high density in the channel walls. The channel also provides guiding for intense laser pulses used for wakefield excitation. Both electron and positron beams can be accelerated in a nearly symmetric fashion. Near-hollow plasma channels can effectively mitigate emittance growth due to Coulomb scattering for high-energy physics applications.

43 PARTICLE ACCELERATORS↗