Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Low temperature diffusion coefficients in the Fe-Ni and FeNiP systems: Application to meteorite cooling rates

The interdiffusion coefficient of FeNi in fcc taenite (gamma) of Fe-Ni and Fe-Ni-0.2 P alloys was measured as a function of temperature between 600 and 900 C. This temperature range is directly applicable to the nucleation and growth of the Widmanstatten pattern in iron meteorites and metal regions of stony and stony-iron meteorites. Diffusion couples were made from FeNi or FeNiP alloys which ensured that the couples were in the taenite phase at the diffusion temperature. The presence or absence of grain boundary diffusion was determined by measuring the Ni profile normal to the existing grain boundaries with the AEM. Ignoring any variation of interdiffusion coefficient with composition, the measured data was plotted versus the reciprocal of the diffusion temperature. The FeNi data generally follow the extrapolated Goldstein, et al. (1965) data from high temperatures. The FeNiP data indicates that small additions of P (0.2 wt%) cause a 3 to 10 fold increase in the FeNi interdifussion coefficient increasing with decreasing temperature. This increase is about the same as that predicted by Narayan and Goldstein (1983) at the Widmanstatten growth temperature.

Dean, D. C.↗

Germanium resistance thermometer calibration at superfluid helium temperatures

The rapid increase in resistance of high purity semi-conducting germanium with decreasing temperature in the superfluid helium range of temperatures makes this material highly adaptable as a very sensitive thermometer. Also, a germanium thermometer exhibits a highly reproducible resistance versus temperature characteristic curve upon cycling between liquid helium temperatures and room temperature. These two factors combine to make germanium thermometers ideally suited for measuring temperatures in many cryogenic studies at superfluid helium temperatures. One disadvantage, however, is the relatively high cost of calibrated germanium thermometers. In space helium cryogenic systems, many such thermometers are often required, leading to a high cost for calibrated thermometers. The construction of a thermometer calibration cryostat and probe which will allow for calibrating six germanium thermometers at one time, thus effecting substantial savings in the purchase of thermometers is considered.

Mason, F. C.↗

Limb effects in satellite temperature sounding

To date, operational satellite temperature retrievals from the TIROS-N/NOAA A-G series of satellites and a large percentage of those produced for research purposes have used statistical techniques to estimate limb effects in satellite-observed radiances. In this study, temperature profiles were derived using the radiative transfer equation in a form which properly takes into account the angle of observation. These temperature profiles were then compared to those derived using the radiative transfer equation with 'nadir radiances' produced by a statistical limb correction technique similar to those now used operationally. This comparison revealed significant differences in the derived temperature profiles at large viewing angles, particularly in the case of strong meridional temperature gradients. Overall, the results suggest that for the calculation of temperature profiles from nonnadir observations, the more proper physical solution is the preferred procedure for deriving temperature fields.

Le Marshall, J. F.↗

Temperature-Sensitive Oscillator

Ingestible thermometer consists of oscillator with temperature-dependent frequency. Device is quartz-crystal oscillator, frequency of which changes in proportion to change in temperature. Temperature-Sensitive Oscillator with nearly linear temperature coefficient of frequency obtained by using high-speed, high-gain, programable operational amplifier such as OP-32 to produce temperature-varying reflected capacitance across quartz crystal. New, small, inexpensive, low-power, temperature-sension circuit suitable for use as ingestible thermometer for measuring internal body temperature.

Kleinberg, L. L.↗

High temperature, short term tensile strength of C6000/PMR-15 composites

Tensile tests were conducted on 0 unidirectionally reinforced Celion 6000 graphite fibers in PMR-15 polyimide matrix. Tensile strengths for coupons subjected to short and long term uniform temperatures were obtained. Thick coupons, heated on one side to produce significant transient through thickness temperature gradients, were tested and compared to the strength of specimens with uniform temperature distributions. All coupons were radiantly heated and reached maximum test temperatures within 15 sec. Tensile loads were applied to the coupons after 15 sec of elevated temperature exposure. Loading rates were selected so that specimen failures occurred within a maximum of 45 sec after reaching the test temperature. Results indicate that significant tensile strength remains beyond the material post cure temperature.

Digiovanni, P. R.↗

Temperature effects on the universal equation of state of solids

Recently it has been argued based on theoretical calculations and experimental data that there is a universal form for the equation of state of solids. This observation was restricted to the range of temperatures and pressures such that there are no phase transitions. The use of this universal relation to estimate pressure-volume relations (i.e., isotherms) required three input parameters at each fixed temperature. It is shown that for many solids the input data needed to predict high temperature thermodynamical properties can be dramatically reduced. In particular, only four numbers are needed: (1) the zero pressure (P=0) isothermal bulk modulus; (2)it P=0 pressure derivative; (3) the P=0 volume; and (4) the P=0 thermal expansion; all evaluated at a single (reference) temperature. Explicit predictions are made for the high temperature isotherms, the thermal expansion as a function of temperature, and the temperature variation of the isothermal bulk modulus and its pressure derivative. These predictions are tested using experimental data for three representative solids: gold, sodium chloride, and xenon. Good agreement between theory and experiment is found.

Vinet, P.↗

Volume and density changes of biological fluids with temperature

The thermal expansion of human blood, plasma, ultrafiltrate, and erythrocycte concentration at temperatures in the range of 4-48 C is studied. The mechanical oscillator technique which has an accuracy of 1 x 10 to the -5 th g/ml is utilized to measure fluid density. The relationship between thermal expansion, density, and temperature is analyzed. The study reveals that: (1) thermal expansion increases with increasing temperature; (2) the magnitude of the increase declines with increasing temperature; (3) thermal expansion increases with density at temperatures below 40 C; and (4) the thermal expansion of intracellular fluid is greater than that of extracellular fluid in the temperature range of 4-10 C, but it is equal at temperatures greater than or equal to 40 C.

Hinghofer-Szalkay, H.↗

Temperature fluctuations and infrared emission from dust particles in a hot gas

In this paper, the effect of temperature fluctuations in very small dust particles caused by electronic collisions with an ambient hot gas, is calculated. The dust-temperature distribution differs strongly from that derived on the basis of equilibrium heating models, peaking at lower temperatures in the stochastically heated case. The resulting infrared spectrum is broadened at short wavelengths, giving much more emission than expected from equilibrium calculations, and at long wavelengths exhibits a lower color temperature. Dust-temperature fluctuations are thus expected to play an important role in determining the infrared spectrum of dusty, X-ray-emitting plasmas. A power-law distribution of grain radii extended to very small grain sizes will have a distinct infrared spectrum characterized by an infrared excess at the Wien side of the spectrum. This excess emission represents a high-temperature component in the spectrum, resulting from the stochastic heating of very small dust particles. Its magnitude depends on the grain-size distribution and the temperature and density of the ambient hot gas. This excess emission may be observed by IRAS in supernova remnants and rich clusters of galaxies.

Dwek, E.↗

Methods for computing comet core temperatures

The temperature profile within the comet nucleus provides the key to an understanding of the history of the volatiles within a comet. Certain difficulties arise in connection with current cometary temperature models. It is shown that the constraint of zero net heat flow can be used to derive general analytical expressions which will allow for the determination of comet core temperature for a spherically symmetric comet, taking into account information about the surface temperature and the thermal conductivity. The obtained results are compared with the expression for comet core temperatures considered by Klinger (1981). Attention is given to analytical results, an example case, and numerical models. The formalization developed makes it possible to determine the core temperature on the basis of the numerical models of the surface temperature.

Mckay, C. P.↗

High temperature monotonic and cyclic deformation in a directionally solidified nickel-base superalloy

Directionally solidified (DS) MAR-M246+Hf was tested in tension and fatigue, at temperatures from 20 C to 1093 C. Tests were performed on (001) oriented specimens at strain rates of 50 % and 0.5 % per minute. In tension, the yield strength was constant up to 704 C, above which the strength dropped off rapidly. A strong dependence of strength on strain rate was seen at the higher temperatures. The deformation mode was observed to change from heterogeneous to homogeneous with increasing temperature. Low Cycle Fatigue tests were done using a fully reversed waveform and total strain control. For a given plastic strain range, lives increased with increasing temperature. For a given temperature strain rate had a strong effect on life. At 704 C, decreasing strain rates decreased life, while at the higher temperatures, decreasing strain rates increased life, for a given plastic strain range. These results could be explained through considerations of the deformation modes and stress levels. At the higher temperatures, marked coarsening caused beneficial stress reductions, but oxidation limited the life. The longitudinal grain boundaries were found to influence slip behavior. The degree of secondary slip adjacent to the boundaries was found to be related to the degree of misorientation between the grains.

Huron, Eric S.↗

Temperature effects on the universal equation of state of solids

Recently it has been argued based on theoretical calculations and experimental data that there is a universal form for the equation of state of solids. This observation was restricted to the range of temperatures and pressures such that there are no phase transitions. The use of this universal relation to estimate pressure-volume relations (i.e., isotherms) required three input parameters at each fixed temperature. It is shown that for many solids the input data needed to predict high temperature thermodynamical properties can be dramatically reduced. In particular, only four numbers are needed: (1) the zero pressure (P = 0) isothermal bulk modulus; (2) its P = 0 pressure derivative; (3) the P = 0 volume; and (4) the P = 0 thermal expansion; all evaluated at a single (reference) temperature. Explicit predictions are made for the high temperature isotherms, the thermal expansion as a function of temperature, and the temperature variation of the isothermal bulk modulus and its pressure derivative. These predictions are tested using experimental data for three representative solids: gold, sodium chloride, and xenon. Good agreement between theory and experiment is found.

Vinet, Pascal↗

Development of an electronically-scanned pressure module for operation at cryogenic temperatures

Pressure and temperature characteristics were measured for a number of multichannel electronically scanned pressure sensors. The tests were made on commercially available units designed to operate in a controlled temperature environment. Measurements of zero shift, sensitivity, and nonlinearity for each transducer were taken over a temperature range from 100 K to 340 K using a computer controlled data acquisition system. The units tested failed to meet accuracy specifications over the complete temperature range, which was expected. However, the sensors showed acceptable and predictable behavior over the temperature range from approximately -40 C (233 K) to 70 C (343 K). It was determined that a combination of local heating and accurate temperature monitoring can result in a device that can be compensated for temperature as well as its other physical properties. The design of a prototype for operation in a cryogenic environment is proposed, and a method for compensation is developed.

Johnson, Preston B.↗

Noncontact temperature pattern measuring device

This invention relates to a noncontact imagine pyrometer system for obtaining the true temperature image of a given substance in a contactless fashion without making assumptions about localized emissivity of the substance or the uniformity of the temperature distribution. Such a contactless temperature imaging system has particular application in the study and production of many materials where the physical contact required to make a conventional temperature measurement drastically effects or contaminates the physical process being observed. Two examples where accurate temperature profiles are of critical interest are: (1) the solid-liquid phase change interface in the production of electronic materials and (2) metastable materials in the undercooling region. The apparent novelty resides in the recognition that an active pyrometer system may be advantageously adapted to perform contactless temperature imaging so that an accurate temperature profile can be obtained.

Elleman, D. D.↗

Temperature control in wafer-level testing of large multi-segment electromigration test structures

The paper describes two methods for maintaining a constant metallization temperature throughout a wafer-level isothermal electromigration test of large multisegment test structures where Joule-heating is high and chip to chuck thermal contact is poor. In the first method, an initial calibration of Joule heating versus metal temperature is carried out. During the isothermal electromigration test, the Joule heating is continuously monitored and the chuck temperature is adjusted based on the calibration results to maintain a constant metal temperature. In the second method, temperature sensors are fabricated on the chip and then the sensors are used to monitor the chip temperature directly. The chuck temperature is then adjusted as needed.

Zamani, Nasser↗

Land-surface temperature measurement from space - Physical principles and inverse modeling

To apply the multiple-wavelength (split-window) method used for satellite measurement of sea-surface temperature from thermal-infrared data to land-surface temperatures, the authors statistically analyze simulations using an atmospheric radiative transfer model. The range of atmospheric conditions and surface temperatures simulated is wide enough to cover variations in clear atmospheric properties and surface temperatures, both of which are larger over land than over sea. Surface elevation is also included in the simulation as the most important topographic effect. Land covers characterized by measured or modeled spectral emissivities include snow, clay, sands, and tree leaf samples. The empirical inverse model can estimate the surface temperature with a standard deviation less than 0.3 K and a maximum error less than 1 K, for viewing angles up to 40 degrees from nadir under cloud-free conditions, given satellite measurements in three infrared channels. A band in the region from 10.2 to 11.0 microns will usually give the most reliable single-band estimate of surface temperature. In addition, a band in either the 3.5-4.0-micron region or in the 11.5-12.6-micron region must be included for accurate atmospheric correction, and a band below the ozone absorption feature at 9.6 microns (e.g., 8.2-8.8 microns) will increase the accuracy of the estimate of surface temperature.

Wan, Zhengming↗

Dielectric determination of the glass transition temperature (T sub g)

The objective is to determine the glass transition temperature of a polymer using a dielectric dissipation technique. A peak in the dissipation factor versus temperature curve is expected near the glass transition temperature T sub g. It should be noted that the glass transition is gradual rather than abrupt, so that the glass transition temperature T sub g is not clearly identifiable. In this case, the glass transition temperature is defined to be the temperature at the intersection point of the tangent lines to the dissipation factor versus temperature curve above and below the transition region, as illustrated.

Ries, Heidi R.↗

Temperature determination of shock layer using spectroscopic techniques

Shock layer temperature profiles are obtained through analysis of radiation from shock layers produced by a blunt body inserted in an arc jet flow. Spectral measurements of N2(+) have been made at 0.5 inch, 1.0 inch, and 1.4 inches from the blunt body. A technique is developed to measure the vibrational and rotational temperatures of N2(+). Temperature profiles from the radiation layers show a high temperature near the shock front and decreasing temperature near the boundary layer. Precise temperature measurements could not be made using this technique due to the limited resolution. Use of a high resolution grating will help to make a more accurate temperature determination. Laser induced fluorescence technique is much better since it gives the scope for selective excitation and a better spacial resolution.

Akundi, Murty A.↗

Nonintrusive Measurement Of Temperature Of LED Junction

Temperature inferred from spectrum of emitted light. Method of determining temperature of junction based on two relevant characteristics of LED. Gap between valence and conduction electron-energy bands in LED material decreases with increasing temperature, causing wavelength of emitted photon to increase with temperature. Other, as temperature increases, non-radiative processes dissipate more of input electrical energy as heat and less as photons in band-gap wavelenth region; optical and quantum efficiencies decrease with increasing temperature. In principal, either characteristic alone used to determine temperature. However, desirable to use both to obtain indication of uncertainty.

Leidecker, Henning↗