Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEST METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Testing military grade magnetics (transformers, inductors and coils).

Engineers and designers are constantly searching for test methods to qualify or 'prove-in' new designs. In the High Reliability world of military parts, design test, qualification tests, in process tests and product characteristic tests, become even more important. The use of in process and function tests has been adopted as a way of demonstrating that parts will operate correctly and survive its 'use' environments. This paper discusses various types of tests to qualify the magnetic components - the current carrying capability of coils, a next assembly 'as used' test, a corona test and inductance at temperature test. Each of these tests addresses a different potential failure on a component. The entire process from design to implementation is described.

36 MATERIALS SCIENCE↗

Characterization and Leaching Tests of the Fluidized Bed Steam Reforming (FBSR) Waste Form for LAW Immobilization

Several supplemental technologies for treating and immobilizing Hanford low activity waste (LAW) have been evaluated. One such immobilization technology is the Fluidized Bed Steam Reforming (FBSR) granular product. The FBSR granular product is composed of insoluble sodium aluminosilicate (NAS) feldspathoid minerals. Production of the FBSR mineral product has been demonstrated both at the industrial and laboratory scale. Pacific Northwest National Laboratory (PNNL) was involved in an extensive characterization campaign. This goal of this campaign was study the durability of the FBSR mineral product and the mineral product encapsulated in a monolith to meet compressive strength requirements. This paper gives an overview of results obtained using the ASTM C 1285 Product Consistency Test (PCT), the EPA Test Method 1311 Toxicity Characteristic Leaching Procedure (TCLP), and the ASTMC 1662 Single-Pass Flow-Through (SPFT) test. Along with these durability tests an overview of the characteristics of the waste form has been collected using Scanning Electron Microscopy (SEM), X-ray Diffraction (XRD), microwave digestions for chemical composition, and surface area from Brunauer, Emmett, and Teller (BET) theory.

FBSR↗

Characterization and Leaching Tests of the Fluidized Bed Steam Reforming (FBSR) Waste Form for LAW Immobilization - 13400

Several supplemental technologies for treating and immobilizing Hanford low activity waste (LAW) have been evaluated. One such immobilization technology is the Fluidized Bed Steam Reforming (FBSR) granular product. The FBSR granular product is composed of insoluble sodium aluminosilicate (NAS) feldspathoid minerals. Production of the FBSR mineral product has been demonstrated both at the industrial and laboratory scale. Pacific Northwest National Laboratory (PNNL) was involved in an extensive characterization campaign. The goal of this campaign was to study the durability of the FBSR mineral product and the encapsulated FBSR product in a geo-polymer monolith. This paper gives an overview of results obtained using the ASTM C 1285 Product Consistency Test (PCT), the EPA Test Method 1311 Toxicity Characteristic Leaching Procedure (TCLP), and the ASTMC 1662 Single-Pass Flow-Through (SPFT) test. Along with these durability tests an overview of the characteristics of the waste form has been collected using Scanning Electron Microscopy (SEM), X-ray Diffraction (XRD), microwave digestions for chemical composition, and surface area from Brunauer, Emmett, and Teller (BET) theory. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Challenge Aerosols for Testing Filters in Spacecraft Air Revitalization Systems

The common means for reducing particle concentrations in air in enclosed spaces, including in space habitats, are source prevention and particle removal by air filters. While air filtration and testing is a well-established discipline and industry, testing and classifying filters according to commonly used standards rely on a test aerosol that is often arbitrary and chosen for the convenience of the test method. In space habitats, the particle size distributions are expected to be quite different than the particle size distributions prescribed in test standards, due to the partial or low gravity environment affecting sedimentation of large particulates like hair or cloth fibers, or the introduction of planetary dust to the pressurized volume. This means that the efficacy of the filter will be quite different in the space habitat than specified according to a prevailing standard. This paper will present a means to specify and generate a “composite” test aerosol that is similar to the measured and reported particle sizes utilizing the International Space Station (ISS) as an example. Application of this test aerosol is expected to yield filter efficiencies and loading effects closer to what one can expect on the ISS and to be useful in determining filter lifetime and replacement cycles. The method can be tuned, within reason, to match other particle size distributions one may encounter, such as the intrusion of Lunar dust for a Lunar lander or habitat.

Filtration↗

Measurement of grain boundary strength of Inconel X-750 superalloy using in-situ micro-tensile testing techniques in FIB/SEM system

Grain boundaries (GBs), known as two-dimensional defects, are omnipresent in polycrystalline metallic alloys and thus influence a wide range of mechanical properties under different environmental conditions like irradiation and corrosion. Therefore, quantifying the strength of individual GBs is critical for understanding the degradation of mechanical properties of materials under different conditions. In this study we developed an efficient approach for the fabrication of micro-tensile specimens with a GB almost perpendicular to the tensile direction, which is expected to advance the development of individual GB tensile testing at micro or nanoscale in a wide scope of materials. Further, an in-situ cantilever micro-tensile testing method was developed and used to quantify the strength of a Σ3 GB in Inconel X-750 with the combination of finite element modeling. The average ultimate tensile strength (UTS) of a non-irradiated Σ3 GB is estimated at around 1.4 GPa, comparable to that of a neutron-irradiated Σ3 GB with a dose of ~1.5 dpa (1.3 GPa). Moreover, the in-situ push-to-pull micro-tensile testing technique developed in this work provides valuable insights into the high-angle GB deformation and fracture behavior. This method generates qualitatively similar ductility behavior before and after neutron irradiation as the bulk material testing. However, the ductility and UTS values obtained from this method are different from bulk measurements due to vastly different specimen dimensions.

36 MATERIALS SCIENCE↗

Statistical Sampling Plan for AGR-5/6/7 Fuel Materials

Kernels, coated particles, and compacts will be manufactured to predefined specifications for irradiation in the AGR 5/6/7 experiments. Many tests will be performed for quality assurance and most of these tests correspond to criteria that have to be met with 95% confidence, based on random samples. This report describes the statistical acceptance testing methods and gives minimum sample sizes for kernels to achieve 95% confidence. Coated particles and compacts will be addressed in revisions to this report. The methods used for sample size determination are described in detail in INL/EXT 05 00349, Statistical Methods Handbook for Advanced Gas Reactor Fuel Materials (Einerson 2005). The statistical approach is to collect a representative sample, apply an acceptance test to the sample, and accept or reject the product based on this test for each criterion. The criteria or “product specifications” are contained in SPC-1352, “AGR 5/6/7 Fuel Specification,” Revision 1 and are duplicated in this plan.

ITO-MgF2 Film Development for PowerSphere Polymer Surface Protection

Multi-kilogram class microsatellites with a PowerSphere electric power system are attractive for fulfilling a variety of potential NASA missions. However, PowerSphere polymer surfaces must be coated with a film that has suitable electrical sheet resistivity for electrostatic discharge control, be resistant to atomic oxygen attack, be transparent to ultraviolet light for composite structure curing and resist ultraviolet light induced darkening for efficient photovoltaic cell operation. In addition, the film must be tolerant of polymer layer folding associated with launch stowage of PowerSphere inflatable structures. An excellent film material candidate to meet these requirements is co-sputtered, indium oxide (In2O3) - tin oxide (SnO2), known as 'ITO', and magnesium fluoride (MgF2). While basic ITO-MgF2 film properties have been the subject of research over the last decade, further research is required in the areas of film durability for space-inflatable applications and precise film property control for large scale commercial production. In this paper, the authors present film durability results for a folded polymer substrate and film resistance to vacuum UV darkening. The authors discuss methods and results in the area of film sheet resistivity measurement and active control, particularly dual-channel, plasma emission line measurement of ITO and MgF2 plasma sources. ITO-MgF2 film polymer coupon preparation is described as well as film deposition equipment, procedures and film characterization. Durability testing methods are also described. The pre- and post-test condition of the films is assessed microscopically and electrically. Results show that an approx. 500A ITO-18vol% MgF2 film is a promising candidate to protect PowerSphere polymer surfaces for Earth orbit missions. Preliminary data also indicate that in situ film measurement methods are promising for active film resistivity control in future large scale production. Future film research plans are also discussed.

Hambourger, Paul D.↗

Development and characterization of an aerosol-generated multi-method analytical particle test material

Ceria (CeO 2 ) particles with low to ultra-low loading of nickel dopant were produced using an aerosol-based, droplet-to-particle synthesis via an in-line calcination technique. This aerosol-based synthesis method enables the production of particles with a monodisperse size distribution. These produced and well-characterized, multi-element, ceria-based particles demonstrate a material exemplar for multi-method analytical testing. They were prepared from a cerium nitrate feedstock where low loading nickel dopant was added at target Ni/(Ni + Ce) atomic percents of 1 %, 0.1 %, and 0.01 %, using a nickel nitrate spike. This methodology proved to produce ceria particles doped with a dynamic range of low to ultra-low loadings of nickel over a 24-h period, with consistent size distribution, morphology, and composition. The successful incorporation of nickel was demonstrated with bulk and single particle inductively coupled plasma mass spectroscopy and revealed notable particle-to-particle elemental homogeneity. X-ray photoelectron spectroscopy demonstrated the presence of a high concentration of nickel dopant incorporated preferentially toward the surface of the particles, and that this dopant aided oxidation of surface Ce(III) atoms to Ce(IV). These particle test materials were then validated through X-ray absorption near edge spectroscopy, comparing the ultra-low 0.01 % Ni and low 1 % Ni-doped ceria samples. This revealed a more-reduced oxidation state of the nickel with an increase in dopant concentration. Finally, this work demonstrates a synthesis and systematic characterization scheme to produce multi-method analytical test particulates.

36 MATERIALS SCIENCE↗

Fire testing in the Boeing 707 cabin section

The goal of a FIREMEN funded contract is the definition of a laboratory test method ranking airplane interior materials by probable performance in post-crash and in-flight fires. A major task is the relation of laboratory results to full scale data. A large test facility for testing materials to the thermal threat of fuel fed and interior fires was developed with quartz lamps and a propane burner in a twenty foot fuselage section. A method was developed to analyze full scale data for the apparent heat, smoke and toxicant release rates of the material tested.

Tustin, E. A.↗

Effects of knock intensity measurement technique and fuel chemical composition on the research octane number (RON) of FACE gasolines: Part 1 – Lambda and knock characterization

The Research and Motor Octane Number (RON and MON) rate the knock propensity of gasoline in the Cooperative Fuel Research (CFR) engine by comparing the knock intensity of sample fuels relative to that of primary reference fuels (PRF), a binary blend of iso-octane and n-heptane. Important differences exist between standard octane testing and automotive spark ignition (SI) engine knock testing including speed, load, air-to-fuel equivalence ratio (lambda), and knock characterization, which lead to a discrepancy between a fuel’s RON rating and its knock resistance characterized on an automotive SI engine based on knock-limited spark advance. This publication is the first of a set of three publications which modify operating parameters of the RON test method (ASTM D2699) to investigate the effects of these differences with automotive SI engine knock-limited spark advance testing. A fuel’s standard RON is evaluated at the lambda of the highest knock intensity, whereas automotive SI engines typically operate at stoichiometry. Here, we analyze the effects of a stoichiometric RON rating methodology. Additionally, the knock intensity response from the standard CFR knockmeter system is compared to a cylinder pressure oscillation-based knock intensity at several lambda settings. All experiments were performed with a set of seven Coordinating Research Council (CRC) Fuels for Advanced Combustion Engines (FACE) gasolines with approximately 95 RON. The fuel chemical composition impacted the lambda of the highest knock intensity, which resulted in fuel-specific offsets between the standard and stoichiometric RON ratings. The knock system comparison showed significant offsets between cylinder pressure-based and knockmeter-based knock intensity levels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of energy weighting using an energy discriminating photon counting detector for breast CT

Purpose: Breast CT is an emerging imaging technique that can portray the breast in 3D and improve visualization of important diagnostic features. Early clinical studies have suggested that breast CT has sufficient spatial and contrast resolution for accurate detection of masses and microcalcifications in the breast, reducing structural overlap that is often a limiting factor in reading mammographic images. For a number of reasons, image quality in breast CT may be improved by use of an energy resolving photon counting detector. In this study, the authors investigate the improvements in image quality obtained when using energy weighting with an energy resolving photon counting detector as compared to that with a conventional energy integrating detector.Methods: Using computer simulation, realistic CT images of multiple breast phantoms were generated. The simulation modeled a prototype breast CT system using an amorphous silicon (a-Si), CsI based energy integrating detector with different x-ray spectra, and a hypothetical, ideal CZT based photon counting detector with capability of energy discrimination. Three biological signals of interest were modeled as spherical lesions and inserted into breast phantoms; hydroxyapatite (HA) to represent microcalcification, infiltrating ductal carcinoma (IDC), and iodine enhanced infiltrating ductal carcinoma (IIDC). Signal-to-noise ratio (SNR) of these three lesions was measured from the CT reconstructions. In addition, a psychophysical study was conducted to evaluate observer performance in detecting microcalcifications embedded into a realistic anthropomorphic breast phantom.Results: In the energy range tested, improvements in SNR with a photon counting detector using energy weighting was higher (than the energy integrating detector method) by 30%–63% and 4%–34%, for HA and IDC lesions and 12%–30% (with Al filtration) and 32%–38% (with Ce filtration) for the IIDC lesion, respectively. The average area under the receiver operating characteristic curve (AUC) for detection of microcalcifications was higher by greater than 19% (for the different energy weighting methods tested) as compared to the AUC obtained with an energy integrating detector.Conclusions: This study showed that breast CT with a CZT photon counting detector using energy weighting can provide improvements in pixel SNR, and detectability of microcalcifications as compared to that with a conventional energy integrating detector. Since a number of degrading physical factors were not modeled into the photon counting detector, this improvement should be considered as an upper bound on achievable performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous 3D–2D image registration and C-arm calibration: Application to endovascular image-guided interventions

Purpose: Three-dimensional to two-dimensional (3D–2D) image registration is a key to fusion and simultaneous visualization of valuable information contained in 3D pre-interventional and 2D intra-interventional images with the final goal of image guidance of a procedure. In this paper, the authors focus on 3D–2D image registration within the context of intracranial endovascular image-guided interventions (EIGIs), where the 3D and 2D images are generally acquired with the same C-arm system. The accuracy and robustness of any 3D–2D registration method, to be used in a clinical setting, is influenced by (1) the method itself, (2) uncertainty of initial pose of the 3D image from which registration starts, (3) uncertainty of C-arm’s geometry and pose, and (4) the number of 2D intra-interventional images used for registration, which is generally one and at most two. The study of these influences requires rigorous and objective validation of any 3D–2D registration method against a highly accurate reference or “gold standard” registration, performed on clinical image datasets acquired in the context of the intervention. Methods: The registration process is split into two sequential, i.e., initial and final, registration stages. The initial stage is either machine-based or template matching. The latter aims to reduce possibly large in-plane translation errors by matching a projection of the 3D vessel model and 2D image. In the final registration stage, four state-of-the-art intrinsic image-based 3D–2D registration methods, which involve simultaneous refinement of rigid-body and C-arm parameters, are evaluated. For objective validation, the authors acquired an image database of 15 patients undergoing cerebral EIGI, for which accurate gold standard registrations were established by fiducial marker coregistration. Results: Based on target registration error, the obtained success rates of 3D to a single 2D image registration after initial machine-based and template matching and final registration involving C-arm calibration were 36%, 73%, and 93%, respectively, while registration accuracy of 0.59 mm was the best after final registration. By compensating in-plane translation errors by initial template matching, the success rates achieved after the final stage improved consistently for all methods, especially if C-arm calibration was performed simultaneously with the 3D–2D image registration. Conclusions: Because the tested methods perform simultaneous C-arm calibration and 3D–2D registration based solely on anatomical information, they have a high potential for automation and thus for an immediate integration into current interventional workflow. One of the authors’ main contributions is also comprehensive and representative validation performed under realistic conditions as encountered during cerebral EIGI.

60 APPLIED LIFE SCIENCES↗

Graphite Oxidation Rate Study on ET-10 and ETU-10 Grades - Task 4: QA Support and Testing for Structural Graphite Oxidation

INL performed targeted oxidation tests to measure oxidation rates for samples of ET-10 and ETU-10 graphite under CRADA No. 21CRA22 Mod. 3, Annex A, “Tritium Testing to Support Kairos Power Advanced Reactor Demonstration” (04/02/2024). All testing was conducted within INL’s Carbon Characterization Laboratory (CCL) using test standard ASTM D7542-21 "Standard Test Method for Air Oxidation of Carbon and Graphite in the Kinetic Regime" [ASTM International, 2021]. Kairos Power provided all test specimens through its graphite vendor Ibiden, Inc. to INL and ASTM specimen specified dimensions. Information within this report only provides the Arrhenius oxidation rate plots as a function of temperature for each graphite grade tested. The raw mass loss per time data will be provided on the Nuclear Data Management and Analysis System (NDMAS) portal located on the INL information system.

36 MATERIALS SCIENCE↗

Hydrogen environment embrittlement

Hydrogen embrittlement is classified into three types: internal reversible hydrogen embrittlement, hydrogen reaction embrittlement, and hydrogen environment embrittlement. Characteristics of and materials embrittled by these types of hydrogen embrittlement are discussed. Hydrogen environment embrittlement is reviewed in detail. Factors involved in standardizing test methods for detecting the occurrence of and evaluating the severity of hydrogen environment embrittlement are considered. The effect of test technique, hydrogen pressure, purity, strain rate, stress concentration factor, and test temperature are discussed. Additional research is required to determine whether hydrogen environment embrittlement and internal reversible hydrogen embrittlement are similar or distinct types of embrittlement.

Gray, H. R.↗

Hydrogen environment embrittlement.

Hydrogen embrittlement is classified into three types: internal reversible hydrogen embrittlement, hydrogen reaction embrittlement, and hydrogen environment embrittlement. Characteristics of and materials embrittled by these types of hydrogen embrittlement are discussed. Hydrogen environment embrittlement is reviewed in detail. Factors involved in standardizing test methods for detecting the occurrence of and evaluating the severity of hydrogen environment embrittlement are considered. The effects of test technique, hydrogen pressure, purity, strain rate, stress concentration factor, and test temperature are discussed.

Gray, H. R.↗

Testing for hydrogen environment embrittlement - Experimental variables

Hydrogen embrittlement is classified into three types: internal reversible hydrogen embrittlement, hydrogen reaction embrittlement, and hydrogen environment embrittlement. Characteristics of and materials embrittled by these types of hydrogen embrittlement are discussed. Hydrogen environment embrittlement is reviewed in detail. Factors involved in standardizing test methods for detecting the occurrence of and evaluating the severity of hydrogen environment embrittlement are considered. The effects of test technique, hydrogen pressure, gas purity, strain rate, stress concentration factor, and test temperature are discussed.

Gray, H. R.↗

The design and development of a constant-speed solar array drive

The design and development of a constant-speed solar array drive system for use in high power communications satellites is described. The relationship between continuity of motion in the solar array drive and spacecraft attitude disturbance is investigated. The selection of the system design based on the design requirements including spacecraft disturbance is discussed. The system comprises two main parts: the drive mechanism including small angle stepper motor and reduction gearing and the control electronics including ministepping drive circuits, such that a very small output step size is achieved. Factors contributing to discontinuities in motion are identified and discussed. Test methods for measurement of very small amplitudes of discontinuity at low rotational rates are described to assist in the testing of similar mechanisms.

Jones, H. M.↗

Frequency-Domain Identification Of Aeroelastic Modes

Report describes flight measurements and frequency-domain analyses of aeroelastic vibrational modes of wings of XV-15 tilt-rotor aircraft. Begins with description of flight-test methods. Followed by brief discussion of methods of analysis, which include Fourier-transform computations using chirp z transformers, use of coherence and other spectral functions, and methods and computer programs to obtain frequencies and damping coefficients from measurements. Includes brief description of results of flight tests and comparisions among various experimental and theoretical results. Ends with section on conclusions and recommended improvements in techniques.

Acree, C. W., Jr.↗