Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Storage capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Nickel-hydrogen capacity loss on storage

Nickel-hydrogen batteries are rapidly becoming accepted for use in low-earth-orbit and geosynchronous orbit applications. With their increased use it has become evident that the storage procedures commonly used for nickel-cadmium cells are not adequate for the nickel-hydrogen system. The capacity loss exhibited by nickel electrodes from various manufacturers when exposed to different storage conditions was determined. A comprehensive test matrix was developed to evaluate capacity loss in nickel electrodes from four different manufacturers. Two types of tests were run; individual electrode tests, which involved flooded capacity and impedance measurements before and after storage under varied conditions of temperature, hydrogen pressure, and electrolyte concentration; and cell tests which primarily evaluated the effects of state-of-charge on storage. The cell tests evaluated capacity loss on cells stored open circuit, shorted and trickle charged at C/100 following a full charge. The results indicate that capacity loss varies with the specific electrode manufacturing process, storage temperature and hydrogen pressure. In general, electrodes stored at low temperatures or low hydrogen pressures exhibited a smaller loss in capacity over the twenty-eight day storage period than those stored at high pressure and high temperature. The capacity loss appears to correlate with the level of cobalt in the nickel electrode, with the most significant loss of capacity occurring in electrodes with higher cobalt levels. Impedance measurements appear to correlate well with the capacity loss observed for a given type of electrode but do not correlate well with the capacity loss between electrodes fabricated by different manufacturers. There was a definite correlation between the electrode potential measured immediately following storage and the measured capacity loss.

Manzo, Michelle A.↗

High-rate, high-capacity electrochemical energy storage in hydrogen-bonded fused aromatics

Designing materials for electrochemical energy storage with short charging times and high charge capacities is a longstanding challenge. The fundamental difficulty lies in incorporating a high density of redox couples into a stable material that can efficiently conduct both ions and electrons. We report all-organic, fused aromatic materials that store up to 310 mAh g –1 and charge in as little as 33 s. This performance stems from abundant quinone/imine functionalities that decorate an extended aromatic backbone, act as redox-active sites, engage in hydrogen bonding, and enable a delocalized high-rate energy storage with stability upon cycling. Here, the extended conjugation and hydrogen-bonding-assisted bulk charge storage contrast with the surface-confined or hydration-dependent behavior of traditional inorganic electrodes.

36 MATERIALS SCIENCE↗

Toward a Four-Electron Redox Quinone Polymer for High Capacity Lithium Ion Storage

Notwithstanding recent advances, current polymeric organic cathode materials have failed to incorporate a high degree of lithium storage in a small molecular framework, resulting in low capacities relative to monomers. This report discloses the development of a lithium salt polymer of dihydroxyanthraquinone (LiDHAQS) capable of storing four Li + per monomer. The combination of storing four Li + per monomer and a low molecular weight monomer results in a capacity of 330 mA h g –1 , a record for this class of material. The additional redox events responsible for added Li + storage occur between 3.0 and 3.6 V versus Li/Li + resulting in an average discharge potential of 2.5 V versus Li/Li + . These metrics combined yield a high energy density of 825 W h kg –1 which is a 55% improvement over commercial lithium cobalt oxide. As a result, the high performance of LiDHAQS makes it a promising material for next generation Li + cathodes.

25 ENERGY STORAGE↗

Voltage Dependent Charge Storage Modes and Capacity in Subnanometer Pores

Using molecular dynamics simulations, we show that charge storage in subnanometer pores follows a distinct voltage-dependent behavior. Specifically, at lower voltages, charge storage is achieved by swapping co-ions in the pore with counterions in the bulk electrolyte. As voltage increases, further charge storage is due mainly to the removal of co-ions from the pore, leading to a capacitance increase. The capacitance eventually reaches a maximum when all co-ions are expelled from the pore. At even higher electrode voltages, additional charge storage is realized by counterion insertion into the pore, accompanied by a reduction of capacitance. The molecular mechanisms of these observations are elucidated and provide useful insight for optimizing energy storage based on supercapacitors.

Chemistry↗

The Potential for Energy Storage to Provide Peaking Capacity in California Under Increased Penetration of Solar Photovoltaics

In this report, we examine the potential for replacing conventional peaking capacity in California with energy storage, including analysis of the changing technical potential with increased storage deployment and the effect of PV deployment. We examine nine years of historic load data, a range of storage durations (2-8 hours), and a range of PV penetration levels (0%-30%). We demonstrate how PV increases the ability of storage to reduce peak net demand. In the scenarios analyzed, the expected penetration of PV in California in 2020 could more than double the potential for 4-hour energy storage to provide capacity services.

14 SOLAR ENERGY↗

West Africa Battery Energy Storage Systems (BESS) Capacity Building - Discussion of BESS Tariffs: Payment Structures and Case Studies [Slides]

Battery Energy Storage Systems (BESS) are emerging as critical assets for enhancing grid reliability, integrating renewable energy, and enabling system flexibility. Yet, the regulatory and financial frameworks that determine how BESS projects are compensated vary widely across jurisdictions. This presentation explores international case studies - from Honduras, Costa Rica, Chile, South Africa, Mexico, and Brazil - to illustrate how tariff design and payment structures are evolving to support large-scale BESS deployment. The cases highlight a range of ownership and revenue models, including cost-of-service mechanisms, energy and capacity payments, and market-based arbitrage, as well as hybrid approaches under development. The discussion will examine key challenges such as defining remuneration for ancillary services, addressing double charging, and accounting for efficiency losses and degradation over time. By comparing experiences across markets, the presentation identifies emerging best practices for valuing BESS and designing tariffs that align technical performance with economic incentives, providing insights for regulators, utilities, and policymakers pursuing storage integration.

25 ENERGY STORAGE↗

The Potential for Energy Storage to Provide Peaking Capacity in California under Increased Penetration of Solar Photovoltaics: Report Summary

Opportunities to provide peaking capacity with low-cost energy storage are emerging. But adding storage changes the ability of subsequent storage additions to meet peak demand. Increasing photovoltaic (PV) deployment also affects storage's ability to provide peak capacity. This study examines storage's potential to replace conventional peak capacity in California.

14 SOLAR ENERGY↗

Capacity Expansion Modeling for Storage Technologies

The Resource Planning Model (RPM) is a capacity expansion model designed for regional power systems and high levels of renewable generation. Recent extensions capture value-stacking for storage technologies, including batteries and concentrating solar power with storage. After estimating per-unit capacity value and curtailment reduction potential, RPM co-optimizes investment decisions and reduced-form dispatch, accounting for planning reserves; energy value, including arbitrage and curtailment reduction; and three types of operating reserves. Multiple technology cost scenarios are analyzed to determine level of deployment in the Western Interconnection under various conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Potential for Battery Energy Storage to Provide Peaking Capacity in the United States

Providing peaking capacity could be a significant U.S. market for energy storage. Of particular focus are batteries with 4-hour duration due to rules in several regions along with these batteries potential to achieve life-cycle cost parity with combustion turbines compared to longer-duration batteries. However, whether 4-hour energy storage can provide peak capacity depends largely on the shape of electricity demand and under historical grid conditions, beyond about 28 GW nationally, the ability of 4-hour batteries to provide peak capacity begins to fall. We find that the addition of renewable generation can significantly increase storage potential by changing the shape of net demand patterns; for example, beyond about 10% penetration of solar photovoltaics, the national practical potential for 4-hour storage to provide peak capacity doubles. The impact of wind generation is less clear and likely requires more detailed study considering the exchange of wind power across multiple regions.

25 ENERGY STORAGE↗

Capacity Assessment and Cost Analysis of Geologic Storage of Hydrogen: A Case Study in Intermountain-West Region USA

Hydrogen is an integral component of the current energy transition roadmap to decarbonize the economy and create an environmentally-sustainable future. However, surface storage options (e.g., tanks) do not provide the required capacity or durability to deploy a regional or nationwide hydrogen economy. In this study, we have analyzed the techno-economic feasibility of the geologic storage of hydrogen in depleted gas reservoirs, salt caverns, and saline aquifers in the Intermountain-West (I-WEST) region. We have identified the most favorable candidate sites for hydrogen storage and estimated the volumetric storage capacity. Our results show that the geologic storage of hydrogen can provide at least 72% of total energy consumption of the I-WEST region in 2020. We also calculated the capital and levelized costs of each storage option. We found that a depleted gas reservoir is the most cost-effective candidate among the three geologic storage options. Interestingly, the cushion gas type plays a significant role in the storage cost when we consider hydrogen storage in saline aquifers. The levelized costs of hydrogen storage in depleted gas reservoirs, salt caverns, and saline aquifers with large-scale storage capacity are approximately $\$$1.15, $\$$2.50, and $\$$3.27 per kg of H 2 , respectively. Here, this work provides essential guidance for the geologic hydrogen storage in the I-WEST region.

08 HYDROGEN↗

The potential for battery energy storage to provide peaking capacity in the United States

Providing peaking capacity could be a significant U.S. market for energy storage. Of particular focus are batteries with 4-h duration due to rules in several regions along with these batteries' potential to achieve life-cycle cost parity with combustion turbines compared to longer-duration batteries. However, whether 4-h energy storage can provide peak capacity depends largely on the shape of electricity demand. Under historical grid conditions, beyond about 28 GW nationally the ability of 4-h batteries to provide peak capacity begins to fall. We find that the addition of renewable generation can significantly increase storage's potential by changing the shape of net demand patterns; for example, beyond about 10% penetration of solar photovoltaics, the national practical potential for 4-h storage to provide peak capacity doubles. Furthermore, the impact of wind generation is less clear and likely requires more detailed study considering the exchange of wind power across multiple regions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ab initio Design of Ca-Decorated Organic Frameworks for High Capacity Molecular Hydrogen Storage with Enhanced Binding

Ab initio calculations show that Ca can decorate organic linkers of metal-organic framework, MOF-5, with a binding energy of 1.25 eV. The Ca-decorated MOF-5 can store molecular hydrogen (H{sub 2}) in both high gravimetric (4.6 wt %) and high volumetric (36 g/l) capacities. Even higher capacities (5.7 wt % and 45 g/l) can be obtained in a rationally designed covalent organic framework system, COF-{alpha}, with decorated Ca. Both density functional theory and second-order Moller-Plesset perturbation calculations show that the H{sub 2} binding in these systems is significantly stronger than the van der Waals interactions, which is required for H{sub 2} storage at near ambient conditions.

08 HYDROGEN↗

Balloon-borne video cassette recorders for digital data storage

A high speed, high capacity digital data storage system was developed for a new balloon-borne gamma-ray telescope. The system incorporates economical consumer products: the portable video cassette recorder (VCR) and a relatively newer item - the digital audio processor. The in-flight recording system employs eight VCRs and will provide a continuous data storage rate of 1.4 megabits/sec throughout a 40 hour balloon flight. Data storage capacity is 25 gigabytes and power consumption is only 10 watts.

Althouse, W. E.↗

Africa Battery Energy Storage Systems (BESS) Capacity Building Li-Ion Battery Degradation and Performance [Slides]

This presentation is intended for power system engineers, operators, and planners who work on isolated power systems that have (or may soon have) high levels of power generation coming from wind turbines, solar farms, and battery energy storage, which are collectively referred to as inverter-based resources. It describes the basics of lithium-ion battery energy storage systems and lithium-ion battery degradation. Battery degradation at the cell-level is explained, and then the structure and degradation of battery energy storage systems is also explained. This is intended to help power system engineers, operators, and planners to understand and effectively utilize battery energy storage systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coaxial Carbon Nanotube Supported TiO 2 @MoO 2 @Carbon Core–Shell Anode for Ultrafast and High-Capacity Sodium Ion Storage

The sluggish kinetic in electrode materials is one of the critical challenges in achieving high-power sodium ion storage. We report a coaxial core-shell nanostructure composed of carbon nanotube (CNT) as the core and TiO 2 @MoO 2 @C as shells for a hierarchically nanoarchitectured anode for improved electrode kinetics. The 1D tubular nanostructure can effectively reduce ion diffusion path, increase electrical conductivity, accommodate the stress due to volume change upon cycling, and provide additional interfacial active sites for enhanced charge storage and transport properties. Significantly, a synergistic effect between TiO 2 and MoO 2 nanostructures is investigated through ex-situ solid state nuclear magnetic resonance. Furthermore, the electrode exhibits a good rate capability (150 mAh g –1 at 20 A g –1 ) and superior cycling stability with a reversibly capacity of 175 mAh g –1 at 10 A g –1 for over 8000 cycles.

25 ENERGY STORAGE↗

Optimized Renewable Energy Integration for EV High-Power Dynamic Wireless Charging Systems

Dynamic wireless charging for electric vehicles is an emerging technology to reduce on-board battery size and extend driving range. Due to its unique characteristic of vehicle-speed-related pulse-like load profile, the high-power dynamic wireless charging system (DWCS) introduces high stress to the utility grid. In this paper, an optimization model for renewable energy integration in the DWCS is proposed to mitigate the grid impact and minimize the operation costs of the whole system. As the load profile of DWCS is related to the traffic volume and various approaching vehicle speeds, the annual average daily traffic data and a stochastic model are used to develop 24-hour load profile of DWCS. To find a tradeoff between grid impact mitigation and operation costs minimization, relationships among power demand from power grid, photovoltaic (PV) capacity, wind energy (WE) capacity and energy storage (ES) capacity are analyzed, and the optimization objective and constraints are developed. Numerical simulation results demonstrate that energy storage integration can greatly mitigate the grid impact of DWCS, and optimal ratio of PV and WE can significantly reduce the operation cost of DWCS.

Zeng, Rong↗