Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Electrochemical and morphological studies of ionic polymer metal composites as stress sensors

Ionic polymer metal composites (IPMCs) are the backbone of a wide range of ionic devices. IPMC mechanoelectric sensors are advanced nanostructured transducers capable of converting mechanical strain into easily detectable electric signal. Such attribute is realized by ion mobilization in and through IPMC nanostructure. In this study we have investigated electrochemical and morphological characteristics of IPMCs by varying the morphology of their metal composite component (conductive network composite (CNC)). We have demonstrated the dependence of electrochemical properties on CNC nanostructure as well as mechanoelectrical performance of IPMC sensors as a function of CNC morphology. Lastly, it is shown that the morphology of CNC can be used as a means to improve sensitivity of IPMC sensors by 3–4 folds.

36 MATERIALS SCIENCE↗

Design and evaluation of large area strip sensor prototypes for the ATLAS Inner Tracker detector

The ATLAS community is facing the last stages prior to the production of the upgraded silicon strip Inner Tracker for the High-Luminosity Large Hadron Collider. An extensive Market Survey was carried out in order to evaluate the capability of different foundries to fabricate large area silicon strip sensors, satisfying the ATLAS specifications. The semiconductor manufacturing company, Infineon Technologies AG, was one of the two foundries, along with Hamamatsu Photonics K.K., that reached the last stage of the evaluation for the production of the new devices. The full prototype wafer layout for the participation of Infineon, called ATLAS17LS-IFX, was designed using a newly developed Python-based Automatic Layout Generation Tool, able to rapidly design sensors with different characteristics and dimensions based on a few geometrical and technological input parameters. Here we present the layout design process and the results obtained from the evaluation of the new Infineon large area sensors before and after proton and neutron irradiations, up to fluences expected in the inner layers of the future ATLAS detector.

79 ASTRONOMY AND ASTROPHYSICS↗

Correlation of Surface Acoustic Wave (SAW) force myography sensor output with elbow joint torque

Accurate assessment of skeletal muscle forces and net joint torque is essential for preventing fatigue-related injuries, optimizing physical training, and monitoring disease progression in neuromuscular conditions. However, existing joint torque evaluation techniques are hindered by limited portability and high operational costs, confining their use to controlled laboratory or clinical settings. Despite substantial advances in wearable joint torque estimation systems, ongoing challenges such as power constraints, bulky wired setups, and susceptibility to environmental or motion artifacts underscore the urgent need for truly batteryless, wireless solutions deployable in real-world settings. This paper proposes a novel surface acoustic wave (SAW)-based force myography (FMG) system for noninvasive measurement of joint torque, validated against a gold-standard electromechanical dynamometer. The approach uses a single SAW sensor embedded in an armband to detect volumetric biceps brachii changes, with a second-order polynomial mapping sensor output and elbow angle to torque. Seven participants were tested in both isometric (15°–90°) and isokinetic (10°/s and 20°/s) supinated elbow flexion tasks. Under isometric conditions, subject-specific calibration achieved a normalized root-mean-square error (NRMSE) of 13.6% ± 6.0% and R 2 = 0.834 ± 0.180, while a group-level model yielded 14.4% ± 6.8% and 0.808 ± 0.208, respectively. For isokinetic trials, the group model produced an NRMSE of 24.1% ± 6.6% at 10°/s and 24.9% ± 08.9% at 20°/s, highlighting the feasibility of using a single-sensor SAW-FMG setup across different speeds. Because SAW devices support wireless, battery-free operation, the proposed system offers a pathway to portable, real-time monitoring for sports medicine, rehabilitation, and clinical diagnostics.

36 MATERIALS SCIENCE↗

Sensoring hydrogen gas concentration using electrolyte made of proton

Hydrogen gas promises to be a major clean fuel in the near future. Thus, sensors that can measure the concentrations of hydrogen gas over a wide dynamic range (e.g., 1 99.9%) are in demand for the production, storage, and utilization of hydrogen gas. However, it is difficult to directly measure hydrogen gas concentrations greater than 10% using conventional sensor [1 11]. We report a simple sensor using an electrolyte made of proton conductive manganese dioxide that enables in situmeasurements of hydrogen gas concentration over a wide range of 0.1 99.9% at room temperature.

08 HYDROGEN↗

Pd/SiO 2 and AuPd/SiO 2 nanocomposite-based optical fiber sensors for H 2 sensing applications

The ability to accurately and safely monitor hydrogen concentration is of significant importance for abroad range of energy, defense, aviation, and aerospace applications with one of the most notable appli-cations being leak detection for hydrogen above the lower explosive limit. Optical-based approachesoffer significant safety advantages as compared to electrical-based sensors and Pd or AuPd-alloys arecommonly utilized as the functional sensor layer due to a well-known, characteristic, and selective inter-action with H 2 . In our work, optical fiber-based sensors comprised of Pd and AuPd alloy nanoparticleincorporated SiO 2 thin films deposited onto unclad multimode silica-based optical fiber evanescent waveabsorption spectroscopy sensing elements have been investigated. Selective, sensitive, and monotonic H 2 sensing responses have been demonstrated at levels significantly greater than the lower explosive limitin the presence of CO and O 2 near room temperature. A tendency for partial oxidation of the noble metalnanoparticles upon exposure to oxidizing atmospheres is confirmed directly through X-ray photoelectronspectroscopy, particularly at elevated temperatures. Monotonic H 2 sensing responses are also observedat elevated temperatures in cases where oxygen is not introduced into the atmosphere. However, morecomplex sensing responses in multi-component elevated temperature gas streams containing oxidizingand reducing species can be observed which likely result from oxidation and reduction of noble metalnanoparticles. Finally, these results demonstrate that the incorporation of noble metals such as Pd and Pd-alloynanoparticles into inert dielectric matrices such as SiO 2 can impart new optical sensing functionalitypotentially useful for H 2 sensing applications.

Evanescent wave absorption spectroscopy↗

Metal–Organic Framework Thin Film Coated Optical Fiber Sensors: A Novel Waveguide-Based Chemical Sensing Platform

Integration of optical fiber with sensitive thin films offers great potential for the realization of novel chemical sensing platforms. In this study, we present a simple design strategy and high performance of nanoporous metal–organic framework (MOF) based optical gas sensors, which enables detection of a wide range of concentrations of small molecules based upon extremely small differences in refractive indices as a function of analyte adsorption within the MOF framework. Thin and compact MOF films can be uniformly formed and tightly bound on the surface of etched optical fiber through a simple solution method which is critical for manufacturability of MOF-based sensor devices. The resulting sensors show high sensitivity/selectivity to CO 2 gas relative to other small gases (H 2 , N 2 , O 2 , and CO) with rapid (< tens of seconds) response time and excellent reversibility, which can be well correlated to the physisorption of gases into a nanoporous MOF. We propose a refractive index based sensing mechanism for the MOF-integrated optical fiber platform which results in an amplification of inherent optical absorption present within the MOF-based sensing layer with increasing values of effective refractive index associated with adsorption of gases.

36 MATERIALS SCIENCE↗

Using the Gerchberg-Saxton algorithm to reconstruct nonmodulated pyramid wavefront sensor measurements

Adaptive optics (AO) is a technique to improve the resolution of ground-based telescopes by correcting, in real-time, optical aberrations due to atmospheric turbulence and the telescope itself. With the rise of Giant Segmented Mirror Telescopes (GSMT), AO is needed more than ever to reach the full potential of these future observatories. One of the main performance drivers of an AO system is the wavefront sensing operation, consisting of measuring the shape of the above mentioned optical aberrations. Aims. The non-modulated pyramid wavefront sensor (nPWFS) is a wavefront sensor with high sensitivity, allowing the limits of AO systems to be pushed. The high sensitivity comes at the expense of its dynamic range, which makes it a highly non-linear sensor. We propose here a novel way to invert nPWFS signals by using the principle of reciprocity of light propagation and the Gerchberg-Saxton (GS) algorithm. We test the performance of this reconstructor in two steps: the technique is first implemented in simulations, where some of its basic properties are studied. Then, the GS reconstructor is tested on the Santa Cruz Extreme Adaptive optics Laboratory (SEAL) testbed located at the University of California Santa Cruz. This new way to invert the nPWFS measurements allows us to drastically increase the dynamic range of the reconstruction for the nPWFS, pushing the dynamics close to a modulated PWFS. The reconstructor is an iterative algorithm requiring heavy computational burden, which could be an issue for real-time purposes in its current implementation. However, this new reconstructor could still be helpful in the case of many wavefront control operations. In conclusion, this reconstruction technique has also been successfully tested on the Santa Cruz Extreme AO Laboratory (SEAL) bench where it is now used as the standard way to invert nPWFS signal.

47 OTHER INSTRUMENTATION↗

A Digital Twin Approach to Study Additive Manufacturing Processing Using Embedded Optical Fiber Sensors and Numerical Modeling

One of the major challenges for metal-powder-based additive manufacturing is measuring and mitigating residual strain induced during the manufacturing processes. This article reports distributed fiber optic sensors embedded in Inconel alloy components as experimental means to validate numerical models of additive manufacturing process. Electroplating was used to deposit a metal protective jacket onto standard telecom single-mode fibers for strain measurements, Fiber sensors were embedded in an Inconel alloy substrate using the laser engineered net shaping (LENS) process. Here by using a Rayleigh-scattering optical frequency domain reflectometer (OFDR), temperature changes, and residual strain in the metal substrate were monitored with 5 mm spatial resolution during the LENS process. Using finite element analysis, temperature and strain profiles induced by the LENS deposition processes were also numerically studied. Discrepancies between the simulated temperature and strain profiles and those measured directly were less than 10%. Results presented in this article demonstrates a digital twin approach to fuse modeling results with distributed fiber sensor measurement data to study additive manufacturing process toward design and fabrication process optimization.

36 MATERIALS SCIENCE↗

RuralAI in Tomato Farming: Integrated Sensor System, Distributed Computing, and Hierarchical Federated Learning for Crop Health Monitoring

Precision horticulture is evolving due to scalable sensor deployment and machine learning (ML) integration. These advancements boost the operational efficiency of individual farms, balancing the benefits of analytics with autonomy requirements. However, given concerns that affect wide geographic regions (e.g., climate change), there is a need to apply models that span farms. Federated learning (FL) has emerged as a potential solution. FL enables decentralized ML across different farms without sharing private data. Traditional FL assumes simple two-tier network topologies and, thus, falls short of operating on more complex networks found in real-world agricultural scenarios. Networks vary across crops and farms and encompass various sensor data modes, extending across jurisdictions. New hierarchical FL (HFL) approaches are needed for more efficient and context-sensitive model sharing, accommodating regulations across multiple jurisdictions. Here, we present the RuralAI architecture deployment for tomato crop monitoring, featuring sensor field units for soil, crop, and weather data collection. HFL with personalization is used to offer localized and adaptive insights. Model management, aggregation, and transfers are facilitated via a flexible approach, enabling seamless communication between local devices, edge nodes, and the cloud.

60 APPLIED LIFE SCIENCES↗

Advanced Optical Sensors to Minimize Energy Consumption in Polymer Extrusion Processes (Final Technical Report)

Project Objective: The objectives of this study are to develop an accurate and stable on-line sensor system to monitor color and composition on-line in polymer melts, to develop a scheme for using the output to control extruders to eliminate the energy, material and operational costs of off-specification product, and to combine or eliminate some extrusion processes. Background: Polymer extrusion processes are difficult to control because the quality achieved in the final product is complexly affected by the properties of the extruder screw, speed of extrusion, temperature, polymer composition, strength and dispersion properties of additives, and feeder system properties. Extruder systems are engineered to be highly reproducible so that when the correct settings to produce a particular product are found, that product can be reliably produced time after time. However market conditions often require changes in the final product, different products or grades may be processed in the same equipment, and feed materials vary from lot to lot. All of these changes require empirical adjustment of extruder settings to produce a product meeting specifications. Optical sensor systems that can continuously monitor the composition and color of the extruded polymer could detect process upsets, drift, blending oscillations, and changes in dispersion of additives. Development of an effective control algorithm using the output of the monitor would enable rapid corrections for changes in materials and operating conditions, thereby eliminating most of the scrap and recycle of current processing. This information could be used to identify extruder systems issues, diagnose problem sources, and suggest corrective actions in real-time to help keep extruder system settings within the optimum control region. Using these advanced optical sensor systems would give extruder operators real-time feedback from their process. They could reduce the amount of off-spec product produced and significantly reduce energy consumption. Also, because blending and dispersion of additives and components in the final product could be continuously verified, we believe that, in many cases, intermediate compounding steps could be eliminated (saving even more time and energy).

47 OTHER INSTRUMENTATION↗

Multi-Sensor Optimal Motion Planning for Radiological Contamination Surveys by Using Prediction-Difference Maps

Distributed and networked mobile sensor platforms using unmanned aerial and/or ground vehicles to survey areas of interest offer a safer and more efficient method for radiological contamination mapping; however, most applications rely on uniformly sweeping of the area in a raster-type motion without utilizing the information available in a dynamic sense. We have developed a fully autonomous optimal motion planning procedure for networks with two or more mobile sensors. The procedure utilizes well-established concepts of Gaussian processes in combination with control laws based on centroidal Voronoi tessellations to achieve optimal next-iteration sensor movements. A new method of informing optimal motion planning is proposed, whereby the absolute difference between the prior and current full-map prediction, referred to as the prediction-difference map, is used as the spatial density function within each Voronoi cell, providing immediate and iterative feedback for dynamic use of available information. The Gaussian process regression model used to estimate the contamination in unvisited locations also provides prediction uncertainties, and can be used as a quantitative metric to assess the confidence in the calculated contamination map; these estimates and prediction uncertainties are unavailable for standard uniform survey routines as they can only produce maps in the vicinity of observed locations. We present through simulation the achievable performance gains from using this new method by directly comparing to a uniform survey method. Results show that using the prediction-difference maps to inform motion planning procedures offers a faster rate of producing an accurate and convergent map relative to a uniform survey route.

47 OTHER INSTRUMENTATION↗

Leak Detection and Sensor Importance Within a Solvent Extraction Process Abstract

In anticipation of the Special Nuclear Material test bed (Beartooth), Idaho National Laboratory has developed a smaller, multi-sensor system for analyzing the solvent extraction process. These systems will allow for research into nuclear fuel processing operations. The multi-sensor system consists of a row of centrifugal contactors and allows for measurement sources that are not traditionally used in the solvent extraction process to be explored including temperature, vibration, acoustics, pH, color, flow, and motor current. Currently, the solvent extraction process is very labor intensive and requires vigilant operators to identify the occurrence of leaks, which can be common during startup or after any change to the system. This study aims to locate leaks using non-traditional measurement sources then to identify which signals were of greatest importance in making this classification using Local Interpretable Model-agnostic Explanations. These results can be used to help solvent extraction process operators detect leaks and to inform future test beds designers to which sensors contain relevant, actionable information in this scenario.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessing a Spectroelectrochemical Sensor's Performance for Detecting [Ru(bpy)3]2+ in Natural and Treated Water

A spectroelectrochemical sensor that combines three modes of selectivity in a single device was evaluated in natural and treated water samples using tris-(2,2’-bipyridyl) ruthenium(II) dichloride hexahydrate, [Ru(bpy)3]2+, as a model analyte. The sensor was an optically transparent indium tin oxide (ITO) electrode coated with a thin film of partially sulfonated polystyrene-block-poly(ethylene-ran-butylene)-block-polystyrene (SSEBS). As the potential of the ITO electrode was cycled from +0.7 to +1.3 V, the analyte changed from the colored [Ru(bpy)3]2+ complex to colorless [Ru(bpy)3]3+ complex and the change in absorbance at 450 nm was used as the optical signal for quantification. Calibration curves were obtained for [Ru(bpy)3]2+ in natural well water, river water and treated tap water with detection limits of 108, 139 and 264 nM, respectively. A standard addition method was developed to determine an *unknown* spike addition concentration of [Ru(bpy)3]2+ in well water. The spectroelectrochemical sensor determined the concentration of [Ru(bpy)3]2+ spiked into a sample of Hanford well water to be 0.39*0.03 mM versus the actual concentration of 0.40 mM.

ITO electrode↗

Machine Learning Discrimination and Ultrasensitive Detection of Fentanyl Using Gold Nanoparticle-Decorated Carbon Nanotube-Based Field-Effect Transistor Sensors

The opioid overdose crisis is a global health challenge. Fentanyl, an exceedingly potent synthetic opioid, has emerged as a leading contributor to the surge in opioid-related overdose deaths. The surge in overdose fatalities, particularly due to illicitly manufactured fentanyl and its contamination of street drugs, emphasizes the urgency for drug-testing technologies that can quickly and accurately identify fentanyl from other drugs and quantify trace amounts of fentanyl. In this paper, gold nanoparticle (AuNP)-decorated single-walled carbon nanotube (SWCNT)-based field-effect transistors (FETs) are utilized for machine learning-assisted identification of fentanyl from codeine, hydrocodone, and morphine. The unique sensing performance of fentanyl led to use machine learning approaches for accurate identification of fentanyl. Employing linear discriminant analysis (LDA) with a leave-one-out cross-validation approach, a validation accuracy of 91.2% is achieved. Meanwhile, density functional theory (DFT) calculations reveal the factors that contributed to the enhanced sensitivity of the Au-SWCNT FET sensor toward fentanyl as well as the underlying sensing mechanism. Finally, fentanyl antibodies are introduced to the Au-SWCNT FET sensor as specific receptors, expanding the linear range of the sensor in the lower concentration range, and enabling ultrasensitive detection of fentanyl with a limit of detection at 10.8 fg mL –1 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ sensor monitoring of multi-class gas porosity formation in laser powder bed fusion using convolutional neural network

In-situ monitoring of defect formation remains a significant challenge in the laser powder bed fusion (LPBF) process. Recent advances have enabled real-time defect detection with machine learning and in-situ sensing technologies; however, most studies focus on binary classification of keyhole pores, limiting nuanced multi-class pore differentiation and formation mechanisms. This work introduces a multi-class pore detection framework (no pore, small pores < 15 µm, and large pores > 15 µm) by leveraging photodiode sensor data alongside high-fidelity synchrotron X-ray imaging. The 15 µm threshold is selected to distinguish between two fundamentally different defect mechanisms, following the physical size-mechanism boundary established by prior high-resolution synchrotron X-ray characterization of Al6061 LPBF. Distinguishing these classes is critical because large keyhole pores are structurally detrimental, whereas small gas pores are often benign, requiring different process control strategies. Thermal emission monitoring data collected simultaneously with high-speed X-ray imaging at the Stanford Synchrotron Radiation Lightsource (SSRL), are correlated with subsurface melt pool dynamics to establish ground truth. Continuous Wavelet Transform (CWT) with optimized parameters converts the photodiode time-series signals into time–frequency images, facilitating feature extraction. Convolutional Neural Networks (CNN) are then applied for real-time multi-class pore classification in an average inference time of 1 ms per signal window. It achieves 79% accuracy and an Area Under the Receiver Operating Characteristic curve (AUC ROC) score of 0.89 with five-fold cross-validation. The results demonstrate that coupling CWT-based feature engineering with CNN architecture enables reliable multi-class pore detection in Al6061 builds using affordable in-situ sensors. This approach advances scalable and affordable quality assurance in additive manufacturing by moving beyond binary defect detection toward more nuanced classification of porosity mechanisms with in-situ sensors and machine learning.

Laser powder bed fusion, Multi-class pores, In-sit↗

Enhanced sensitivity of hemoglobin sensor using dual-core photonic crystal fiber

A Hemoglobin (Hb) biosensor based on dual-core photonic crystal fiber is proposed and analyzed. In this paper, the effective refractive index dependency on the Hb concentration within a blood sample is utilized in obtaining the transmission spectrum variation. The results are calculated using full vectorial finite element method. Through this study, the effect of the structure geometrical parameters on the sensor performance is optimized to maximize the sensor sensitivity. The numerical results show a sensitivity of 8.013 nm/g/dL for the X-polarized mode at 3.7 cm fiber length and 7.68 nm/g/dL for the Y-polarized mode at 3.2 cm fiber length of the proposed sensor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitivity enhancement of surface plasmon resonance sensor with 2D material covered noble and magnetic material (Ni)

In this paper, surface plasmon resonance (SPR) sensor on 2D materials such as MoS{sub 2} and graphene on Au and magnetic material Ni in Kretschmann configuration is analyzed using transfer matrix method. Here we noted that by sandwiching the MoS{sub 2} layer between the Au and Ni film and adding graphene over Ni film improved the sensitivity as high as 229°/RIU. We also noted that the sensitivity of the proposed sensor changes with the addition of no. of layers of graphene and MoS{sub 2}. We expect that such a high sensitivity SPR sensor could find optional application in chemical examination, medical diagnostic and biological detections.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A method for the characterization of intra-pixel response of infrared sensor

Due to the response variations within a pixel, response of sensor varies with the positions of the point target. The accurate measurement of intra-pixel response of the sensor is the key to high-precision centroid estimation and radiometric calibration. In this paper, we establish an intra-pixel response model based on the pixel structure and use Gauss function to describe the beam spot profile. We further calculate the full width at half maximum (FWHM) of the Gauss function and the fill factor of the infrared sensor using the grid search algorithm. Experimental results show that the Gauss function FWHM differences among different pixels using the same radius could be less than 6%. The fill factors are not constant in different pixels because of errors in the process of manufacture and assembly, and the error between model and measured values is less than 3.6%. This work could be useful for stellar calibration and centroid estimation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗