Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Sensitivity to measure the anomalous gauge couplings of the Higgs boson via W{sup +}W{sup +} scattering at the CERN LHC

A sensitive way to test the anomalous HVV (V=W{sup {+-}},Z{sup 0}) couplings via pp{yields}W{sup +}W{sup +}jj{yields}l{sup +}{nu}l{sup +}{nu}jj at LHC was proposed by Zhang, Kuang, He, and Yuan [Phys. Rev. D 67, 114024 (2003)]. We studied the sensitivity to measure the anomalous gauge couplings of Higgs boson with optimized cuts. In this way, the sensitivity can be enhanced. Based on the optimized cuts and distribution of {delta}Pt(ll), the measurement of the couplings can be further improved with a binned maximum likelihood fit. It shows that, with an integrated luminosity of 300 fb{sup -1}, the anomalous HWW and HZZ couplings can be measured at the level of 0.007-0.032 and 0.007-0.013 TeV{sup -1}, respectively, for the linearly realized effective Lagrangian.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity of neutrino mass experiments to the cosmic neutrino background

The KATRIN neutrino experiment is a next-generation tritium beta decay experiment aimed at measuring the mass of the electron neutrino to better than 200 meV at 90% C.L. Because of its intense tritium source, KATRIN can also serve as a possible target for the process of neutrino capture, {nu}{sub e}+{sup 3}H{yields}{sup 3}He{sup +}+e{sup -}. The latter process, possessing no energy threshold, is sensitive to the cosmic neutrino background (C{nu}B). In this paper, we explore the potential sensitivity of the KATRIN experiment to the relic neutrino density. The KATRIN experiment is sensitive to a C{nu}B overdensity ratio of 2.0x10{sup 9} over standard concordance model predictions (at 90% C.L.), addressing the validity of certain speculative cosmological models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pulsar timing sensitivity to very-low-frequency gravitational waves

We compute the sensitivity, constrained by instrumental, propagation, and other fundamental noises, of pulsar timing to very-low-frequency gravitational waves (GWs). Reaching predicted GW signal strengths will require suppression of time-of-arrival fluctuations caused by interstellar plasma turbulence and a reduction of white rms timing noise to < or approx. 100 ns. Assuming negligible intrinsic pulsar rotational noise, perfect time transfer from time standard to observatory, and stable pulse profiles, the resulting single-pulsar signal-to-noise ratio=1 sensitivity is limited by terrestrial time standards at h{sub rms}{approx}2x10{sup -16} [f/ (1 cycle/year)]-1/2 for f<3x10{sup -8} Hz, where f is the Fourier frequency and a bandwidth of 1 cycle/(10 years) is assumed. Since this sensitivity is comparable to predicted GW signal levels, a reliable detection will require substantial signal-to-noise ratio improvement via pulsar timing array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Laboratory Sensitivity to Variation of the Fine-Structure Constant using Highly Charged Ions

We study atomic systems that are in the frequency range of optical atomic clocks and have enhanced sensitivity to potential time variation of the fine-structure constant {alpha}. The high sensitivity is due to coherent contributions from three factors: high nuclear charge Z, high ionization degree, and significant differences in the configuration composition of the states involved. Configuration crossing keeps the frequencies in the optical range despite the large ionization energies. We discuss a few promising examples that have the largest {alpha} sensitivities seen in atomic systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Traffic-Sensitive Live Migration of Virtual Machines

In this paper we address the problem of network contention between the migration traffic and the VM application traffic for the live migration of co-located Virtual Machines (VMs). When VMs are migrated with pre-copy, they run at the source host during the migration. Therefore the VM applications with predominantly outbound traffic contend with the outgoing migration traffic at the source host. Similarly, during post-copy migration, the VMs run at the destination host. Therefore the VM applications with predominantly inbound traffic contend with the incoming migration traffic at the destination host. Such a contention increases the total migration time of the VMs and degrades the performance of VM application. Here, we propose traffic-sensitive live VM migration technique to reduce the contention of migration traffic with the VM application traffic. It uses a combination of pre-copy and post-copy techniques for the migration of the co-located VMs, instead of relying upon any single pre-determined technique for the migration of all the VMs. We base the selection of migration techniques on VMs' network traffic profiles so that the direction of migration traffic complements the direction of the most VM application traffic. We have implemented a prototype of traffic-sensitive migration on the KVM/QEMU platform. In the evaluation, we compare traffic-sensitive migration against the approaches that use only pre-copy or only post-copy for VM migration. We show that our approach minimizes the network contention for migration, thus reducing the total migration time and the application degradation.

Live Migration↗

Fast Neutron Sensitivity with HPGe

In addition to being excellent gamma-ray detectors, germanium detectors are also sensitive to fast neutrons. Incident neutrons undergo inelastic scattering {Ge(n,n')Ge*} off germanium nuclei and the resulting excited states emit gamma rays or conversion electrons. The response of a standard 140% high-purity germanium (HPGe) detector with a bismuth germanate (BGO) anti-coincidence shield was measured for several neutron sources to characterize the ability of the HPGe detector to detect fast neutrons. For a sensitivity calculation performed using the characteristic fast neutron response peak that occurs at 692 keV, the 140% germanium detector system exhibited a sensitivity of ~175 counts / kg of WGPu metal in 1000 seconds at a source-detector distance of 1 meter with 4 in. of lead shielding between source and detector. Theoretical work also indicates that it might be possible to use the shape of the fast-neutron inelastic scattering signatures (specifically, the end-point energy of the long high energy tail of the resulting asymmetric peak) to gain additional information about the energy distribution of the incident neutron spectrum. However, the experimentally observed end-point energies appear to be almost identical for each of the fast neutron sources counted. Detailed MCNP calculations show that the neutron energy distributions impingent on the detector for these sources are very similar in this experimental configuration, due to neutron scattering in a lead shield (placed between the neutron source and HPGe detector to reduce the gamma ray flux), the BGO anti-coincidence detector, and the concrete floor.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Adaptive Power Flow Approximations With Second-Order Sensitivity Insights

The power flow equations are fundamental to power system planning, analysis, and control. However, the inherent non-linearity and non-convexity of these equations present formidable obstacles in problem-solving processes. To mitigate these challenges, recent research has proposed adaptive power flow linearizations that aim to achieve accuracy over wide operating ranges. The accuracy of these approximations inherently depends on the curvature of the power flow equations within these ranges, which necessitates considering second-order sensitivities. In this paper, we leverage second-order sensitivities to both analyze and improve power flow approximations. We evaluate the curvature across broad operational ranges and subsequently utilize this information to inform the computation of various sample-based power flow approximation techniques. Additionally, we leverage second-order sensitivities to guide the development of rational approximations that yield linear constraints in optimization problems. In conclusion, this approach is extended to enhance accuracy beyond the limitations of linear functions across varied operational scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A New LMP-Sensitivity-Based Heterogeneous Decomposition for Transmission and Distribution Coordinated Economic Dispatch

Transmission and distribution coordinated economic dispatch (TDCED) will be necessary to settle the problems caused by high penetrations of distributed generators in future grids. An efficient heterogeneous decomposition algorithm (HGD) was proposed to solve the TDCED, but it may diverge occasionally. To overcome this shortcoming, a new HGD (N-HGD) with enhanced convergency is proposed and studied in this paper. Compared with the previous HGD, the N-HGD similarly decomposes the TDCED into transmission ED and distribution ED subproblems, but it considers the sensitivity of the boundary locational marginal price to load injections to enhance convergency and avoid divergence. Two kinds of sensitivity computing methods, M-c and M-p, are studied. M-c is based on a centralized sensitivity equation, executed on the transmission side. M-p is based on a probing mechanism and can be executed distributedly on the distribution side. The reason for the N-HGD's improved convergency is theoretically analyzed, and the optimality is proven. Numerical tests show that N-HGD performs better than the original HGD, as well as a penalty-based modified HGD that needs a careful parametertuning process. Furthermore, compared with M-c, an M-p-based N-HGD is preferable because it has a much lower computational cost and no additional communicational cost.

distribution↗

Sensitivity Analysis of a Polyphase Wireless Power Transfer System under Off-Nominal Conditions

Misaligned and/or variable coil airgaps cause coupling coefficient variation in wireless power transfer (WPT) systems, resulting in a decrease in the system’s transmitted power and efficiency. This paper presents sensitivity analyses of a three-phase, Y-Y connected, series-tuned WPT system in the frequency domain in terms of several different electric vehicle wireless charging off-nominal conditions (misalignments in Δ x and Δ y directions, change of airgap Δ z , and the roll Δψ, pitch Δθ, and yaw ΔΦ angles) as specified in Society of Automotive Engineers (SAE) J2954 Standard. Coil inductance matrices were obtained by measuring the self- and mutual inductances of the primary and secondary coil phase windings at variable airgap classes (from 5 cm to 30 cm) for five different charging positions as identified in SAE J2954. These 6 × 6 inductance matrices were used in sensitivity and Plexim/PLECS simulation analyses. The sensitivity of the WPT system was analyzed analytically using the input impedance and phase angle, voltage gain, current gain, quality factor, and coupling coefficient parameters of the series-tuned WPT system. The results were confirmed experimentally on a 50 kW WPT system.

42 ENGINEERING↗

Global synthesis of the temperature sensitivity of leaf litter breakdown in streams and rivers

Streams and rivers are important conduits of terrestrially derived carbon (C) to atmospheric and marine reservoirs. Leaf litter breakdown rates are expected to increase as water temperatures rise in response to climate change. The magnitude of increase in breakdown rates is uncertain, given differences in litter quality and microbial and detritivore community responses to temperature, factors that can influence the apparent temperature sensitivity of breakdown and the relative proportion of C lost to the atmosphere vs. stored or transported downstream. We synthesized 1025 records of litter breakdown in streams and rivers to quantify its temperature sensitivity, as measured by the activation energy (Ea, in eV). Temperature sensitivity of litter breakdown varied among twelve plant genera for which Ea could be calculated. Higher values of Ea were correlated with lower-quality litter, but these correlations were influenced by a single, N-fixing genus (Alnus). Ea values converged when genera were classified into three breakdown rate categories, potentially due to continual water availability in streams and rivers modulating the influence of leaf chemistry on breakdown. Across all data representing 85 plant genera, the Ea was 0.34 ± 0.04 eV, or approximately half the value (0.65 eV) predicted by metabolic theory. Our results indicate that average breakdown rates may increase by 5–21% with a 1–4 °C rise in water temperature, rather than a 10–45% increase expected, according to metabolic theory. Differential warming of tropical and temperate biomes could result in a similar proportional increase in breakdown rates, despite variation in Ea values for these regions (0.75 ± 0.13 eV and 0.27 ± 0.05 eV, respectively). The relative proportions of gaseous C loss and organic matter transport downstream should not change with rising temperature given that Ea values for breakdown mediated by microbes alone and microbes plus detritivores were similar at the global scale.

54 ENVIRONMENTAL SCIENCES↗

Substrate availability and not thermal acclimation controls microbial temperature sensitivity response to long-term warming

Microbes are responsible for cycling carbon (C) through soils, and predicted changes in soil C stocks under climate change are highly sensitive to shifts in the mechanisms assumed to control the microbial physiological response to warming. Two mechanisms have been suggested to explain the long-term warming impact on microbial physiology: microbial thermal acclimation and changes in the quantity and quality of substrates available for microbial metabolism. Yet studies disentangling these two mechanisms are lacking. To resolve the drivers of changes in microbial physiology in response to long-term warming, we sampled soils from 13- and 28-year-old soil warming experiments in different seasons. We performed short-term laboratory incubations across a range of temperatures to measure the relationships between temperature sensitivity of physiology (growth, respiration, carbon use efficiency, and extracellular enzyme activity) and the chemical composition of soil organic matter. We observed apparent thermal acclimation of microbial respiration, but only in summer, when warming had exacerbated the seasonally-induced, already small dissolved organic matter pools. Irrespective of warming, greater quantity and quality of soil carbon increased the extracellular enzymatic pool and its temperature sensitivity. We propose that fresh litter input into the system seasonally cancels apparent thermal acclimation of C-cycling processes to decadal warming. Our findings reveal that long-term warming has indirectly affected microbial physiology via reduced C availability in this system, implying that earth system models including these negative feedbacks may be best suited to describe long-term warming effects on these soils.

59 BASIC BIOLOGICAL SCIENCES↗

The sensitivity of patient specific IMRT QC to systematic MLC leaf bank offset errors

Purpose: Patient specific IMRT QC is performed routinely in many clinics as a safeguard against errors and inaccuracies which may be introduced during the complex planning, data transfer, and delivery phases of this type of treatment. The purpose of this work is to evaluate the feasibility of detecting systematic errors in MLC leaf bank position with patient specific checks. Methods: 9 head and neck (H and N) and 14 prostate IMRT beams were delivered using MLC files containing systematic offsets ({+-}1 mm in two banks, {+-}0.5 mm in two banks, and 1 mm in one bank of leaves). The beams were measured using both MAPCHECK (Sun Nuclear Corp., Melbourne, FL) and the aS1000 electronic portal imaging device (Varian Medical Systems, Palo Alto, CA). Comparisons with calculated fields, without offsets, were made using commonly adopted criteria including absolute dose (AD) difference, relative dose difference, distance to agreement (DTA), and the gamma index. Results: The criteria most sensitive to systematic leaf bank offsets were the 3% AD, 3 mm DTA for MAPCHECK and the gamma index with 2% AD and 2 mm DTA for the EPID. The criterion based on the relative dose measurements was the least sensitive to MLC offsets. More highly modulated fields, i.e., H and N, showed greater changes in the percentage of passing points due to systematic MLC inaccuracy than prostate fields. Conclusions: None of the techniques or criteria tested is sufficiently sensitive, with the population of IMRT fields, to detect a systematic MLC offset at a clinically significant level on an individual field. Patient specific QC cannot, therefore, substitute for routine QC of the MLC itself.

60 APPLIED LIFE SCIENCES↗

Performance of a high-sensitivity dedicated cardiac SPECT scanner for striatal uptake quantification in the brain based on analysis of projection data

Purpose: The authors have previously reported the advantages of high-sensitivity single-photon emission computed tomography (SPECT) systems for imaging structures located deep inside the brain. DaTscan (Isoflupane I-123) is a dopamine transporter (DaT) imaging agent that has shown potential for early detection of Parkinson disease (PD), as well as for monitoring progression of the disease. Realizing the full potential of DaTscan requires efficient estimation of striatal uptake from SPECT images. They have evaluated two SPECT systems, a conventional dual-head gamma camera with low-energy high-resolution collimators (conventional) and a dedicated high-sensitivity multidetector cardiac imaging system (dedicated) for imaging tasks related to PD. Methods: Cramer-Rao bounds (CRB) on precision of estimates of striatal and background activity concentrations were calculated from high-count, separate acquisitions of the compartments (right striata, left striata, background) of a striatal phantom. CRB on striatal and background activity concentration were calculated from essentially noise-free projection datasets, synthesized by scaling and summing the compartment projection datasets, for a range of total detected counts. They also calculated variances of estimates of specific-to-nonspecific binding ratios (BR) and asymmetry indices from these values using propagation of error analysis, as well as the precision of measuring changes in BR on the order of the average annual decline in early PD. Results: Under typical clinical conditions, the conventional camera detected 2 M counts while the dedicated camera detected 12 M counts. Assuming a normal BR of 5, the standard deviation of BR estimates was 0.042 and 0.021 for the conventional and dedicated system, respectively. For an 8% decrease to BR = 4.6, the signal-to-noise ratio were 6.8 (conventional) and 13.3 (dedicated); for a 5% decrease, they were 4.2 (conventional) and 8.3 (dedicated). Conclusions: This implies that PD can be detected earlier with the dedicated system than with the conventional system; therefore, earlier identification of PD progression should be possible with the high-sensitivity dedicated SPECT camera.

60 APPLIED LIFE SCIENCES↗

WE-D-BRE-07: Variance-Based Sensitivity Analysis to Quantify the Impact of Biological Uncertainties in Particle Therapy

Purpose: In particle therapy, treatment planning and evaluation are frequently based on biological models to estimate the relative biological effectiveness (RBE) or the equivalent dose in 2 Gy fractions (EQD2). In the context of the linear-quadratic model, these quantities depend on biological parameters (α, β) for ions as well as for the reference radiation and on the dose per fraction. The needed biological parameters as well as their dependency on ion species and ion energy typically are subject to large (relative) uncertainties of up to 20–40% or even more. Therefore it is necessary to estimate the resulting uncertainties in e.g. RBE or EQD2 caused by the uncertainties of the relevant input parameters. Methods: We use a variance-based sensitivity analysis (SA) approach, in which uncertainties in input parameters are modeled by random number distributions. The evaluated function is executed 10{sup 4} to 10{sup 6} times, each run with a different set of input parameters, randomly varied according to their assigned distribution. The sensitivity S is a variance-based ranking (from S = 0, no impact, to S = 1, only influential part) of the impact of input uncertainties. The SA approach is implemented for carbon ion treatment plans on 3D patient data, providing information about variations (and their origin) in RBE and EQD2. Results: The quantification enables 3D sensitivity maps, showing dependencies of RBE and EQD2 on different input uncertainties. The high number of runs allows displaying the interplay between different input uncertainties. The SA identifies input parameter combinations which result in extreme deviations of the result and the input parameter for which an uncertainty reduction is the most rewarding. Conclusion: The presented variance-based SA provides advantageous properties in terms of visualization and quantification of (biological) uncertainties and their impact. The method is very flexible, model independent, and enables a broad assessment of uncertainties. Supported by DFG grant WI 3745/1-1 and DFG cluster of excellence: Munich-Centre for Advanced Photonics.

60 APPLIED LIFE SCIENCES↗

Sensitivity of the diagnostic radiological index of protection to procedural factors in fluoroscopy

Purpose: To evaluate the sensitivity of the diagnostic radiological index of protection (DRIP), used to quantify the protective value of radioprotective garments, to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams to be used in measuring the DRIP. Methods: Monte Carlo simulations were performed to determine the shape of the scattered x-ray spectra incident on the operator in different clinical fluoroscopy scenarios, including interventional radiology and interventional cardiology (IC). Two clinical simulations studied the sensitivity of the scattered spectrum to gantry angle and patient size, while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial simulations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size, and beam quality for constant technical factors. Average energy (E{sub avg}) was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affect the scattered spectrum indirectly through their effect on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in IC, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusions: The scattered spectrum striking the operator in fluoroscopy is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle.

60 APPLIED LIFE SCIENCES↗

SU-F-J-40: Evaluation of Sensitivity of the Automatic Matching Between Cone-Beam CT Image and Simulation CT Image in TrueBeam 2.0 Imaging System 6DoF Considering Different Uncertainty Sources

Purpose: To estimate the sensitivity of TrueBeam 2.0 Imaging System 6DoF automatic matching tool through the acquisition of cone-beam CT images in different phantoms applying submillimeter translations and rotations of tenths of a degree and registered with image simulation CT. Methods: To evaluate overall system-wide image, we consider two uncertainties source; First, the uncertainty of the manual phantom displacement (ε-m). This uncertainty is calculated by a digital caliper (0.01 mm) for vertical (Vrt), lateral (Lat) and longitudinal (Lng). A digital inclinometer (0.01°) for the pitch and roll and the own phantom scale to evaluate the coordinate rotation (Rtn). The second uncertainty is the displacement detected by the algorithm system of matching (σ-d) that we obtain from the standard deviations of the different measurements. We use three different phantoms. The BrainLab Radiosurgery system for supporting masks with an anthropomorphic dummy adapted to allow displacements of 0.1 mm in Vrt, Lat and Lng dimensions and rotations of 0.1° in Pitch dimension. For the analysis of the Rtn and Roll dimensions we use two homemade phantoms (RinoRot and RinoRoll, La Fe Hospital, Valencia, Spain) that allow rotations of 0.3°. Results: In the case of manual displacement of 0.10 ± 0.03 mm in the translations, the system detect 0.10 ± 0.07 mm, 0.12 ± 0.07 mm and 0.13 ± 0.07 mm (mean ± SD) in Lat, Vrt and Lng respectively. In the case of rotational dimension, manual displacement of 0.3 ± 0.1° was detected with 0.19 ± 0.06°, 0.29 ± 0.03° and 0.27 ± 0.06° in Pitch, Roll and Rtn. Conclusion: We conclude that the sensitivity of the automatic matching system is within 0.10 mm in translations and 0.3° in rotations. These values are under the own sensitivity of the software.

60 APPLIED LIFE SCIENCES↗

WE-DE-201-11: Sensitivity and Specificity of Verification Methods Based On Total Reference Air Kerma (TRAK) Or On User Provided Dose Points for Graphically Planned Skin HDR Brachytherapy

Purpose: To investigate the sensitivity and specificity of a novel verification methodology for image-guided skin HDR brachytherapy plans using a TRAK-based reasonableness test, compared to a typical manual verification methodology. Methods: Two methodologies were used to flag treatment plans necessitating additional review due to a potential discrepancy of 3 mm between planned dose and clinical target in the skin. Manual verification was used to calculate the discrepancy between the average dose to points positioned at time of planning representative of the prescribed depth and the expected prescription dose. Automatic verification was used to calculate the discrepancy between TRAK of the clinical plan and its expected value, which was calculated using standard plans with varying curvatures, ranging from flat to cylindrically circumferential. A plan was flagged if a discrepancy >10% was observed. Sensitivity and specificity were calculated using as a criteria for true positive that >10% of plan dwells had a distance to prescription dose >1 mm different than prescription depth (3 mm + size of applicator). All HDR image-based skin brachytherapy plans treated at our institution in 2013 were analyzed. Results: 108 surface applicator plans to treat skin of the face, scalp, limbs, feet, hands or abdomen were analyzed. Median number of catheters was 19 (range, 4 to 71) and median number of dwells was 257 (range, 20 to 1100). Sensitivity/specificity were 57%/78% for manual and 70%/89% for automatic verification. Conclusion: A check based on expected TRAK value is feasible for irregularly shaped, image-guided skin HDR brachytherapy. This test yielded higher sensitivity and specificity than a test based on the identification of representative points, and can be implemented with a dedicated calculation code or with pre-calculated lookup tables of ideally shaped, uniform surface applicators.

60 APPLIED LIFE SCIENCES↗

Crystal Structure of the Human K2P TRAAK, a Lipid- and Mechano-Sensitive K[superscript +] Ion Channel

TRAAK channels, members of the two-pore domain K{sup +} (potassium ion) channel family K2P, are expressed almost exclusively in the nervous system and control the resting membrane potential. Their gating is sensitive to polyunsaturated fatty acids, mechanical deformation of the membrane, and temperature changes. Physiologically, these channels appear to control the noxious input threshold for temperature and pressure sensitivity in dorsal root ganglia neurons. We present the crystal structure of human TRAAK at a resolution of 3.8 angstroms. The channel comprises two protomers, each containing two distinct pore domains, which create a two-fold symmetric K{sup +} channel. The extracellular surface features a helical cap, 35 angstroms tall, that creates a bifurcated pore entry way and accounts for the insensitivity of two-pore domain K{sup +} channels to inhibitory toxins. Two diagonally opposed gate-forming inner helices form membrane-interacting structures that may underlie this channel's sensitivity to chemical and mechanical properties of the cell membrane.

59 BASIC BIOLOGICAL SCIENCES↗