Scanning transmission electron microscopy analysis of Ge(O)/(graphitic carbon nitride) nanocomposite powder
Analytical electron microscopy has revealed the structure of particles that were synthesized by chemical reaction of GeO{sub 2} with NaBH{sub 4} in the basic solution including graphitic carbon nitride (g-C{sub 3}N{sub 4}) powders. The g-C{sub 3}N{sub 4} was arranged by recrystallization of melamine at 600 °C under N{sub 2} gas atmosphere. The samples were dried at 60 °C or 180 °C for 4 h. The g-C{sub 3}N{sub 4} was observed as lamellae of several ten nm or less in size and had an amorphous-like structure with a distorted lattice in an area as small as a few hundred pm in size. The reaction product was Ge(O) particles as fine as several nm in size and composed of Ge and O atoms. Most of the particles must be of GeO{sub 2−x} with the amorphous-like structure that has also a distorted lattice in an area of a few hundred pm in size. In the sample dried at 60 °C, the particles were found to be dispersed in a wide area on the g-C{sub 3}N{sub 4} lamella. It is hard to recognize those particles in TEM images. The particles in the sample dried at 180 °C became larger and were easily observed as isolated lumps. Hence, these powders can be regarded as GeO{sub 2}/g-C{sub 3}N{sub 4} or Ge/GeO{sub 2}/g-C{sub 3}N{sub 4} nanocomposites, and expected to be applicable to anode materials for high energy Li-ion batteries due to Ge catalysis effect, accordingly. - Graphical abstract: STEM analysis of Ge(O)/(graphitic carbon nitride) nanocomposite powder. - Highlights: • Graphitic (g)-C{sub 3}N{sub 4} powder was prepared at 600 °C by recrystallization of melamine. • Ge(O) was prepared by chemical reaction in a solution including the g-C{sub 3}N{sub 4} powders. • The products can be regarded as GeO{sub 2}/g-C{sub 3}N{sub 4} or Ge/GeO{sub 2}/g-C{sub 3}N{sub 4} nanocomposites. • GeO{sub 2} was amorphous several-nm particles and g-C{sub 3}N{sub 4} was amorphous lamella of several 10 nm in size. • We expect them to be applicable for high energy Li-ion battery anode materials.
Plastic deformation and material transfer on steel gage blocks during low force mechanical probing
Contact probing of gaging surfaces is enabled throughout dimensional metrology. Probe tips such as ruby, sapphire, or diamond are commonly employed as styli for universal length measuring machines (ULMs) and coordinate measuring machines (CMMs) due to the hardness, durability, and wear resistance. Gaging surfaces of gage blocks are precision ground or lapped, with very low surface roughness to enable wringing. Damage or contamination of these surfaces can prevent wringing and lead to measurement error. Experimental investigations using a horizontal ULM and CMM have revealed that even at low force settings (≤0.16 N), probe materials such as ruby and sapphire can cause plastic deformation to hardened carbon chrome steel (such as AISI 52,100) gage block surfaces at the microscale, likely attributed to fretting-associated wear. Under some conditions, permanent transfer of material from the probe stylus to the gaging surface is possible. Results show irreversible changes and damage to gaging surfaces with repeated probe contact on a ULM and CMM. Optical microscopy, optical profilometry, and scanning electron microscopy (SEM) provide a semi-quantitative assessment of microscale plastic deformation and material transfer. X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), and Raman techniques validate chemical constituency of reference materials used (gage blocks and probes) and also identify makeup of deposits on gaging surfaces following probe contact.
Field retrieved photovoltaic backsheet survey from diverse climate zones: Analysis of degradation patterns and phenomena
Understanding the impact of climate stressors on photovoltaic (PV) backsheet degradation in real-use conditions is critical to improve the accelerated testing exposures, extend the backsheet lifetime, and increase the confidence in PV reliability. Here, in this work, a total of 33 PV module backsheets were retrieved from six climatic zones worldwide with 2 - 28 years of exposure. These modules included five types of backsheet air-side materials (or outer layer): poly(vinylidene fluoride) (PVDF), poly(tetrafluoroethylene-co-hexafluoropropylene-co-vinylidene fluoride) (THV), poly(vinyl fluoride) (PVF), poly(ethylene terephthalate) (PET), and polyamide (PA). Attenuated total reflection Fourier-transform infrared spectroscopy (ATR-FTIR) was used to identify air-side materials. The degradation induced color change, gloss loss, and chemical material changes analyzed using optical microscopy, differential scanning calorimetry (DSC), scanning electron microscopy (SEM), colorimetry (yellowness index (YI)), and gloss measurements. PVDF, THV, and PVF air-side layer backsheets, in particular PVF, had minimal degradation in the air-side layer appearance and chemical structures after exposure in different climatic zones. The PET air-side backsheets exhibited obvious color increase (22.55 YI units after about 9 years exposure) and the PA/PA/PA backsheets showed large gloss loss (up to 76.4 %) relative to the unexposed backsheets. Severe cracks between cells that penetrated through the entire thickness of backsheets are observed on PA/PA/PA backsheets after 4-6 years of exposure in 6 climatic zones. The current indoor exposure standards were not sufficient to identify this degradation type. However, fluoropolymer based PV backsheets showed lower levels of degradation predictors and increased climatic resistance. Specific samples (PVF) showed little change from baseline after 28 years of outdoor exposure.
Scanning transmission electron microscopy: Albert Crewe s vision and beyond
Explore the source record for details and available documents.
Identification of light elements in silicon nitride by aberration-corrected scanning transmission electron microscopy
Explore the source record for details and available documents.
Oxidation-state sensitive imaging of cerium dioxide by atomic-resolution low-angle annular dark field scanning transmission electron microscopy
Not Available
Extended Depth of Field for High-Resolution Scanning Transmission Electron Microscopy
Explore the source record for details and available documents.
Accurate Nanoscale Crystallography in Real-Space Using Scanning Transmission Electron Microscopy
Abstract not provided
Study of Effects of Cl and Se in CdSeTe Solar Cells Using Scanning Transmission Electron Microscopy
Solar cells based on poly-crystalline CdTe thin films are a leading candidate for low-cost conversion of solar energy due to their near optimum band gap, high absorption coefficient and ease of manufacturing. Due to non-radiative Shockley-Read-Hall (SRH) recombination at grain boundaries (GBs), dislocations, and point defects, current CdTe-based solar cell efficiency appears to be limited to ~22%, which is still below the theoretical limit (~30%). It is well known that CdCl 2 annealing is essential for high performing CdTe solar cells due to grain recrystallization and passivation of defect states within the band gap by Cl atoms. Incorporating Se into CdTe to form an alloyed CdSeTe solar cells also shows a high overall efficiency. Simultaneous addition of Cl and Se can further improve the efficiencies of CdTe solar cells, but yet a comprehensive experimental and theoretical study of effects of Cl and Se in CdSeTe solar cell is absent.
Optimizing Nonrigid Registration for Scanning Transmission Electron Microscopy Image Series
Abstract
In-Plane Anisotropy in Mono- and Few-Layer ReS 2 Probed by Raman Spectroscopy and Scanning Transmission Electron Microscopy
Explore the source record for details and available documents.
Visualizing Gold Nanoparticle Uptake in Live Cells with Liquid Scanning Transmission Electron Microscopy
Not Available
Three-dimensional location of a single dopant with atomic precision by aberration-corrected scanning transmission electron microscopy
Explore the source record for details and available documents.