Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Characterization of SiGe/Si multi-quantum wells for infrared sensing

SiGe epitaxial layers are integrated as an active part in thermal detectors. To improve their performance, deeper understanding of design parameters, such as thickness, well periodicity, quality, and strain amount, of the layers/interfaces is required. Oxygen (2–2500 × 10{sup −9} Torr) was exposed prior or during epitaxy of SiGe/Si multilayers. In this range, samples with 10 nTorr oxygen were processed to investigate layer quality and noise measurements. Temperature coefficient of resistance was also measured to evaluate the thermal response. These results demonstrate sensitivity of SiGe-based devices to size and location of defects in the structure.

36 MATERIALS SCIENCE↗

Tomographic investigation of fermi level pinning at focused ion beam milled semiconductor surfaces

Electron holography in the transmission electron microscope (TEM) offers the spatial and signal resolution for studying effects like Fermi level pinning or dopant concentration variations important for the design of modern electronic devices. To overcome the loss of information along the projection direction, surface effects, and surface damage due to TEM specimen preparation, we apply electron holographic tomography to analyze the 3D potential distribution of semiconductor samples prepared by focused-ion-beam. We observe mid-band gap pinning of the Fermi level at Si surfaces but valence band pinning at Ge surfaces. The pinning extends over tens of nanometers into the bulk.

36 MATERIALS SCIENCE↗

Room temperature multiferroic properties and magnetoelectric coupling in Sm and Ni substituted Bi{sub 4−x}Sm{sub x}Ti{sub 3−x}Ni{sub x}O{sub 12±δ} (x = 0, 0.02, 0.05, 0.07) ceramics

Lead free multiferroic Bi{sub 4−x}Sm{sub x}Ti{sub 3−x}Ni{sub x}O{sub 12±δ} (x = 0.02, 0.05, and 0.07) samples have been synthesized by conventional solid state route. X-ray diffraction analysis reveals single phase up to x = 0.07, and a secondary phase appears at x > 0.07. Raman spectroscopy confirms the local distortions in the crystal. Field emission scanning electron microscopy shows plate like grains. Substitution has increased the orthorhombic distortion, grain size, and hence the ferroelectric transition temperature (T{sub c}). A significant reduction in the values of dielectric constant (ε′) and loss tangent (tan δ) has been observed with the increase of Sm and Ni ions. The increase in dc resistivity at room temperature has been found with substitution. Enhancement in the values of remnant polarization (2P{sub r}) and magnetization (2M{sub r}) is observed. Magnetoelectric coupling coefficient (α) values of 0.60 mV/cm/Oe are achieved in Bi{sub 4−x}Sm{sub x}Ti{sub 3−x}Ni{sub x}O{sub 12±δ} ceramic samples. Hence, we have successfully converted the ferroelectric Bi{sub 4}Ti{sub 3}O{sub 12} into a multiferroic, which is a new lead free multiferroic material, can be useful for future electromagnetic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Liquid-induced damping of mechanical feedback effects in single electron tunneling through a suspended carbon nanotube

In single electron tunneling through clean, suspended carbon nanotube devices at low temperature, distinct switching phenomena have regularly been observed. These can be explained via strong interaction of single electron tunneling and vibrational motion of the nanotube. We present measurements on a highly stable nanotube device, subsequently recorded in the vacuum chamber of a dilution refrigerator and immersed in the {sup 3}He/ {sup 4}He mixture of a second dilution refrigerator. The switching phenomena are absent when the sample is kept in the viscous liquid, additionally supporting the interpretation of dc-driven vibration. Transport measurements in liquid helium can thus be used for finite bias spectroscopy where otherwise the mechanical effects would dominate the current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental quantum Bernoulli factories via Bell-basis measurements

Randomness processing in the Bernoulli factory framework provides a concrete setting in which quantum resources can outperform classical ones. We experimentally demonstrate quantum randomness processing based on Bell-basis measurements of two identical input quoins prepared on IBM superconducting hardware. Using only the measurement outcomes (and no external classical randomness source), we realize the classically inconstructible Bernoulli doubling primitive f(p)=2p, and, as intermediate outputs from the same Bell-measurement statistics, an exact fair coin f(p)=1/2 and the classically inconstructible function f(p)=4p(1−p). We benchmark the measured output biases against ideal predictions and discuss the impact of device noise. Our results establish a simple resource-efficient experimental primitive for quantum-to-classical randomness processing and support the viability of quantum Bernoulli factories for quantum-enhanced stochastic simulation and sampling tasks.

Roy, Tanay [Fermilab] (ORCID:000000019442862X)↗

ChatGPT and Other Large Language Models for Cybersecurity of Smart Grid Applications

Cybersecurity breaches targeting electrical substations constitute a significant threat to the integrity of the power grid, necessitating comprehensive defense and mitigation strategies. Any anomaly in information and communication technology (ICT) should be detected for secure communications between devices in digital substations. This paper proposes large language models (LLMs), e.g., ChatGPT, for the cybersecurity of IEC 61850-based communications. Multi-cast messages such as generic object oriented system events (GOOSE) and sampled values (SV) are used for case studies. The proposed LLM-based cybersecurity framework includes, for the first time, data pre-processing of communication systems and human-in-the-loop (HITL) training (considering the cybersecurity guidelines recommended by humans). The results show a comparative analysis of detected anomaly data carried out based on the performance evaluation metrics for different LLMs. A hardware-in-the-loop (HIL) testbed is used to generate and extract a dataset of IEC 61850 communications.

ChatGPT↗

Characterizations of Aged Glass/Ethylene Vinyl Acetate/Glass Using Fluorescence Spectroscopy and Instrumented Indentation

Ethylene vinyl acetate (EVA) is widely used as an encapsulant in photovoltaic devices, which are exposed to simultaneous UV irradiation, thermal, and humidity conditions. Aging behaviors of the EVA were characterized using confocal fluorescence spectroscopy with submicron scale resolutions of cross-sections of aged EVA samples. Additionally, mechanical properties of fluorescing regions in the aged EVAs where fluorescence emission was measured were investigated using a nanoindentation technique. In this study, we characterized two different formulations of EVA in glass/EVA/glass specimens after UV irradiation at 40 degrees C, 60 degrees C and 80 degrees C with 50 % relative humidity for 180 days. The fluorescence intensities on the UV irradiated sides of EVA samples were higher than those for the unexposed sides over wavelengths from 400 nm to 800 nm, and intensity differences between the two sides became more pronounced when the specimens were aged at higher temperatures. Elastic moduli of UV irradiated side for samples measured by instrumented indentation decreased, compared to unaged EVA samples, while fluorescent intensity increased with increasing the aging temperature.

14 SOLAR ENERGY↗

Developments and Challenges in the Design of the ITER DRGA

We report the ITER Diagnostic Residual Gas Analyzer (DRGA) will measure the distribution of gas species, i.e., deuterium (D), tritium (T), and impurities, in the divertor exhaust stream and in the plasma periphery, with time resolution relevant to fusion plasma–wall particle dynamics. The uniqueness of the DRGA, over previous implementations of plasma dynamics residual gas analysis, is an integrated approach, combining mass and low-temperature plasma-activated optical spectroscopy, in a differentially pumped analysis station. A further unique feature of the ITER divertor-specific DRGA is an ~8-m separation of the analysis station from the sampled pumping duct, while still maintaining a ~1-s response time for hydrogen isotopic concentrations. ITER DRGA final design activities are strongly benefiting from testing of prototypical DRGA components and methods on present fusion devices, most currently on JET and W7-X. DRGA systems are implemented on both these devices and include sensors (and pumping methods) that are directly relevant to the ITER DRGA design. The recent JET-DTE2 campaign has provided the first experience on operating the combined ITER DRGA sensors with D-T plasmas. While enhancing system design for ITER, this experience on operating devices has also revealed additional engineering challenges, which further guide the continuing final design project. Meanwhile, the recent determination that the ITER DRGA, with slight optimization, will resolve the helium isotopes well enough to support an ITER pre-DT, He-3-based heating scheme, has greatly increased ITER Research Program interest in the DRGA and its implementation well ahead of the DT phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Isotopic Ratios of Samarium by TIMS for Nuclear Forensic Application

The isotopic ratio of Nd, Sm, and Gd can provide important information regarding fissile material (nuclear devices, reactors), neutron environment, and device yield. These studies require precise measurement of Sm isotope ratios, by either TIMS or MC-ICP-MS. There has been an increasing trend to measure smaller and smaller quantities of Sm bearing samples. In nuclear forensics 10-100 ng of Sm are needed for precise measurement. To measure sub-ng Sm samples using TIMS for nuclear forensic analysis.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Results from Accelerated Environmental Testing of Barcoded Identifiers for UF 6 Cylinders

This report provides the qualitative and quantitative results from the accelerated environmental testing campaign. A total of 444 samples were subjected to 10 tests that included UV, salt fog, temperature, blowing dust, high pressure and temperature water, and impact exposure. Each sample included a two-dimensional barcode and an alphanumeric string representing the cylinder identification number. When evaluating the results, primary attention was placed on the decodability of the barcodes using a barcode verifier device, since machine scanning a barcode offers the greatest efficiency and accuracy gains when reading cylinder identification numbers during safeguards activities. Contrast was considered the critical test parameter because maintaining contrast under a wide range of environmental conditions is of fundamental importance to decoding the identification number of the barcodes. Additionally, manual readability of the alphanumeric string was considered an important factor in determining whether an inspector or operator could still read the identification number of the cylinder if the barcode proved to be undecodable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Inchfab – A ultra-low-cost micro and nanofabrication platform (CRADA Final Report)

Inchfab Inc. is developing an ultra-low cost suite of micro- and nanofabrication platforms which allows greater process flexibility and short development cycles. In traditional manufacturing environments, virtually all fabrication happens on 6-12” substrates–which requires prohibitively expensive fabrication facilities (“fabs”). By scaling the substrate size down to 1-2”, Inchfab reduces the capital cost and physical footprint of a fab by two to three orders of magnitude, while still retaining a similar level of performance. Additionally, the design of the Inchfab will allow users to develop fully-customizable fabrication processes, accommodating non-traditional materials and process diversity. Ultimately, the Inchfab platform will enable innovative device designs which currently have limited possibility of being realized. This CRADA project worked on preliminary research to test the feasibility of the Inchfab platform by utilizing equipment at Berkeley Lab to evaluate test samples and characterize equipment performance.

42 ENGINEERING↗

Performance Improvement of LTS Undulators for Synchrotron Light Sources

The joint expertise of ANL and FNAL has led to the production of $\text{Nb}_{3}\text{Sn}$ undulator magnets in operation in the ANL Advanced Photon Source (APS). These magnets showed performance reproducibility close to the short sample limit, and a design field increase of 20% at 820 A. However, the long training did not allow obtaining the expected 50% increase of the on-axis magnetic field with respect to the ∼1 T produced at 450 A current in the ANL NbTi undulator. To address this, 10-pole long undulator prototypes were fabricated, and CTD-101K was replaced as impregnation material with TELENE, an organic olefin-based thermosetting dicyclopentadiene resin produced by RIMTEC Corporation, Japan. Training and magnet retraining after a thermal cycle were nearly eliminated, with only a couple of quenches needed before reaching short sample limit at over 1,100 A. TELENE will enable operation of $\text{Nb}_{3}\text{Sn}$ undulators much closer to their short sample limit, expanding the energy range and brightness intensity of light sources. TELENE is Co-60 gamma radiation resistant up to 7–8 MGy, and therefore already applicable to impregnate planar, helical and universal devices operating in lower radiation environments than high energy colliders.

43 PARTICLE ACCELERATORS↗

Manipulating Ferroelectrics through Changes in Surface and Interface Properties

Ferroelectric materials are used in many applications of modern technologies including information storage, transducers, sensors, tunable capacitors, and other novel device concepts. In many of these applications, the ferroelectric properties, such as switching voltages, piezoelectric constants, or stability of nanodomains, are crucial. For any application, even for material characterization, the material itself needs to be interfaced with electrodes. On the basis of the structural, chemical, and electronic properties of the interfaces, the measured material properties can be determined by the interface. This is also true for surfaces. However, the importance of interfaces and surfaces and their effect on experiments are often neglected, which results in many dramatically different experimental results for nominally identical samples. Therefore, it is crucial to understand the role of the interface and surface properties on internal bias fields and the domain switching process. Here, the nanoscale ferroelectric switching process and the stability of nanodomains for Pb(Zr,Ti)O 3 thin films are investigated by using scanning probe microscopy. Interface and surface properties are modulated through the selection/redesign of electrode materials as well as tuning the surface-near oxygen vacancies, which both can result in changes of the electric fields acting across the sample, and consequently this controls the measured ferroelectric and domain retention properties. By understanding the role of surfaces and interfaces, ferroelectric properties can be tuned to eliminate the problem of asymmetric domain stability by combining the effects of different electrode materials. Lastly, this study forms an important step toward integrating ferroelectric materials in electronic devices.

30 DIRECT ENERGY CONVERSION↗

Microfluidic Cell-based Assays in Stem Cell and Other Rare Cell Type Research

Microfluidics is a technology defined by the engineered precise manipulation of minute amount of liquids through channels with dimensions in the micron scale. Much of microfluidic devices used for biomedical purposes are produced in the form of so called “lab-on-a-chip” format, where multiple steps of conventional biochemical analyses such as staining, washing, and signal collection are miniaturized and integrated into chips fabricated from polymer or glass. Cell-based microfluidic lab-on-achip technology provides some obvious advantages: 1) drastically reduced sample and reagent requirement, and 2) separation and detection with improved sensitivity due to fluid properties at the microscale, i.e. laminar flow. Based on these two advantages, the obvious place where microfluidic cell assays will provide the most benefit is wherescientists must gather much information from precious little sample. Stem cells and other precious cell types such as circulating tumor cells (CTCs), and rare immune subsets are the perfect match for microfluidic multiplex assays. The recent demonstration that multiple cellular changes such as surface receptor activation, protein translocation, long and short RNA, and DNA changes can all be extracted from intact single cells paves the way to systems level understanding of cellular states during development or disease. Finally, with the ability to preserve cell integrity in a microfluidic device during multiplexed analysis, one also preserves the single cell resolution, where information regarding the cell-to-cell heterogeneity during differentiation or response to stimuli is vitally important.

59 BASIC BIOLOGICAL SCIENCES↗

Photochemical deterioration of the organic/metal contacts in organic optoelectronic devices

We study the effect of exposure to light on a wide range of organic/metal contacts that are commonly used in organic optoelectronic devices and found that irradiation by light in the visible and UV range results in a gradual deterioration in their electrical properties. This photo-induced contact degradation reduces both charge injection (i.e., from the metal to the organic layer) and charge extraction (i.e., from the organic layer to the metal). X-ray photoelectron spectroscopy (XPS) measurements reveal detectable changes in the interface characteristics after irradiation, indicating that the photo-degradation is chemical in nature. Changes in XPS characteristics after irradiation suggests a possible reduction in bonds associated with organic-metal complexes. Measurements of interfacial adhesion strength using the four-point flexure technique reveal a decrease in organic/metal adhesion in irradiated samples, consistent with a decrease in metal-organic bond density. The results shed the light on a new material degradation mechanism that appears to have a wide presence in organic/metal interfaces in general, and which likely plays a key role in limiting the stability of various organic optoelectronic devices such as organic light emitting devices, organic solar cells, and organic photo-detectors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-T-77: A Novel Test for Coincidence Between Light Fields and Electron Radiation Fields

Purpose: To validate a novel real time quality assurance device, as a means to test coincidence of light fields to electron radiation fields. Method and Materials: Use a Raven™ (LAP of America Laser Applications) detector, both light fields and electron radiation fields of various electron cones and cutouts from two Clinacs (Varian Medical) were sensed by the phosphor screen and registered by a CCD camera of the device. During measurements, the screen surface of Raven was placed at ISO center level facing the radiation field at any setup angle. Subsequently the light field and the electron radiation field (with 100 MU) were captured separately by the device. The measurements were then analyzed using the Raven software with a maximal 25 by 25 cm^2 field size and 0.25 mm resolution. The results were further compared against those using chromic graphic film (EBT3). To ensure consistence only the dimensions through the central axis were recorded. All the films were analyzed with Dose Lab Pro™ v6.70. Coincidence comparisons were done within the tests on one Clinac and between the two Clinacs. Results: The similar difference means of the field coincidence are indicated from the 18 samples by EBT films and 34 by the Raven as 1.33 ± 0.87 mm verses 1.06 ± 0.58 mm (p = 0.74). The mean differences of the field coincidence between the two Clinacs, 1.16 ± 0.68 mm (n=16) and 1.16 ± 0.48 mm (n=18) respectively, also suggest no statistical difference (p= 0.40). Conclusion: The Raven™ is a comparable quality verification device to the chromic graphic film (EBT3) in checking the coincidence between light and electron radiation fields. In this investigation, the Raven device provided highly reproducible results with real time analysis. Further improvements in its resolution and automatic analyzing capability are warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-258: Development of a New Patient Set-Up Monitoring System Using Force Sensing Resistor (FSR) Sensor for the Radiation Therapy

Purpose: The purpose of this work is to develop a new patient set-up monitoring system using force sensing resistor (FSR) sensors that can confirm pressure of contact surface and evaluate its feasibility. Methods: In this study, we focused on develop the patient set-up monitoring system to compensate for the limitation of existing optical based monitoring system, so the developed system can inform motion in the radiation therapy. The set-up monitoring system was designed consisting of sensor units (FSR sensor), signal conditioning devices (USB cable/interface electronics), a control PC, and a developed analysis software. The sensor unit was made by attaching FSR sensor and dispersing pressure sponge to prevent error which is caused by concentrating specific point. Measured signal from the FSR sensor was sampled to arduino mega 2560 microcontroller, transferred to control PC by using serial communication. The measured data went through normalization process. The normalized data was displayed through the developed graphic user interface (GUI) software. The software was designed to display a single sensor unit intensity (maximum 16 sensors) and display 2D pressure distribution (using 16 sensors) according to the purpose. Results: Changes of pressure value according to motion was confirmed by the developed set-up monitoring system. Very small movement such as little physical change in appearance can be confirmed using a single unit and using 2D pressure distribution. Also, the set-up monitoring system can observe in real time. Conclusion: In this study, we developed the new set-up monitoring system using FSR sensor. Especially, we expect that the new set-up monitoring system is suitable for motion monitoring of blind area that is hard to confirm existing optical system and compensate existing optical based monitoring system. As a further study, an integrated system will be constructed through correlation of existing optical monitoring system. This work was supported by the Industrial R&D program of MOTIE/KEIT. [10048997, Development of the core technology for integrated therapy devices based on real-time MRI guided tumor tracking] and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗