Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

In situ monitoring of hydrogen loss during pyrolysis of wood by neutron imaging

Hydrogen is an element of fundamental importance for energy but hard to quantify in bulk materials. Neutron radiography was used to map in situ loss of elemental hydrogen from beech tree wood samples during pyrolysis. The samples consisted of three wood cylinders (finished dowel or cut branch) of approximately 1 cm in length. The samples were pyrolyzed under vacuum in a furnace vessel that was placed inside a cold neutron imaging beamline using a temperature ramp of 5 °C/min from ambient up to 400 °C. Neutron radiographs with exposures of 30 s were sequentially recorded with a charge-coupled device over the course of the experiment. Relative absorbance/scattering of the neutron beam by each sample was based on intensity (or brightness) values as a function of pixel position. The much larger neutron cross section for hydrogen compared to carbon and oxygen enables almost direct conversion of neutron attenuation into sample hydrogen content for each time step during the pyrolysis experiment. Target and vessel temperatures were recorded concurrently with collection of the radiographs so that changes could be directly correlated to different states of pyrolysis. The most visible change appeared at the initial phase of the 400 °C plateau as evidenced by strong hydrogen loss and primarily diametric shrinking of the samples. In conclusion, the loss of elemental hydrogen between initial and final states of pyrolysis was estimated to be about 70%.

08 HYDROGEN↗

Containerless processing of glass

Ground-based research on the containerless melting of glass and experiments performed during a flight on the SPAR 6 are described. Experiments leading to selection of the flight sample composition, a silica-modified gallia/calcia glass, and the preparation of a one quarter inch diameter flight sample are described. During the flight experiment, a sample of the glass was containerless melted and cooled to a clear glass in a single axis acoustic positioning apparatus. The functioning of the flight experimental hardware was evaluated. The evaluation of the sample is presented.

Happe, R. A.↗

MO-FG-204-09: High Spatial Resolution and Artifact-Free CT Bone Imaging at Off-Centered Positions: An Application of Model-Based Iterative Reconstruction

Purpose: Although the anatomy of interest should be positioned as close as possible to the isocenter of CT scanners, off-centering may be inevitable during certain exams in clinical practice such as lumbar spine and elbow imaging. Off-centering degrades image sharpness, generates streak artifacts, and sometimes creates blooming artifacts due to truncation. The purpose of this work was to investigate whether the use of model-based image reconstruction (MBIR) can alleviate the negative impacts of off-centering to achieve high quality CT bone imaging. Methods: Both an anthropomorphic phantom and an ex vivo swine elbow sample were scanned at centered and off-centered positions using clinical CT bone scan protocols. The magnitude of off-centering was determined from localizer radiographs. Both FBP and MBIR reconstructions were performed. For FBP, both standard and Bone Plus kernels commonly used in bone imaging were used. Objective assessment of image sharpness, noise standard deviation, and noise nonuniformity were performed. Additionally, we retrospectively analyzed human subject data acquired under off-centered conditions as a validation study. Results: In FBP images of the phantom, off-centering by 10 cm led to a 14% increase in noise (p<1e-3) and a 68% increase in noise nonuniformity (p<0.02). A visible drop in bone sharpness was observed. In contrast, no significant difference in the noise magnitude or the noise nonuniformity between the centered and off-centered MBIR images was found. The image sharpness of off-centered MBIR images outperformed that of FBP images reconstructed with the Bone Plus kernel. In images of the swine elbow off-centered by 20 cm, not only was the noise and spatial resolution performance improved by MBIR, truncation artifacts were also elliminated. The human subject study generated similar results, in which the visibility of the off-centered lumbar spine was significantly improved. Conclusion: High quality CT bone imaging at off-centered positions can be achieved using MBIR. This work was partially supported by an NIH grant R01CA169331 and GE Healthcare. K. Li, D. Gomez-Cardona: Nothing to disclose. G.-H. Chen: Research funded, GE Healthcare; Research funded, Siemens AX. A. Budde, J. Hsieh: Employee, GE Healthcare.

60 APPLIED LIFE SCIENCES↗

THE REAL ISSUE WITH WALL DEPOSITS IN CLOSED FILTER CASSETTES - WHAT'S THE SAMPLE?

The measurement of aerosol dusts has long been utilized to assess the exposure of workers to metals. Tools used to sample and measure aerosol dusts have gone through many transitions over the past century. In particular, there have been several different techniques used to sample for beryllium, not all of which might be expected to produce the same result. Today, beryllium samples are generally collected using filters housed in holders of several different designs, some of which are expected to produce a sample that mimics the human capacity for dust inhalation. The presence of dust on the interior walls of cassettes used to hold filters during metals sampling has been discussed in the literature for a number of metals, including beryllium, with widely varying data. It appears that even in the best designs, particulates can enter the sampling cassette and deposit on the interior walls rather than on the sampling medium. The causes are not well understood but are believed to include particle bounce, electrostatic forces, particle size, particle density, and airflow turbulence. Historically, the filter catch has been considered to be the sample, but the presence of wall deposits, and the potential that the filter catch is not representative of the exposure to the worker, puts that historical position into question. This leads to a fundamental question: What is the sample? This article reviews the background behind the issue, poses the above-mentioned question, and discusses options and a possible path forward for addressing that question.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beam position monitor gate functionality implementation and applications

We introduce a novel technique to implement gate functionality for the beam position monitors (BPM) at the National Synchrotron Light Source II (NSLS-II). The functionality, now implemented in FPGA, allows us to acquire two separated bunch-trains’ synchronized turn-by-turn (TBT) data simultaneously with the NSLS-II in-house developed BPM system. The gated position resolution is improved about 3 times by narrowing the sampling width. Experimentally we demonstrated that the machine lattice could be transparently characterized with the gated TBT data of a short diagnostic bunch-train Cheng et al., 2017; Li et al., 2017. Other applications, for example, precisely characterizing storage ring impedance/wake-field through recording the beam positions of two separated bunch trains has been experimentally demonstrated.

43 PARTICLE ACCELERATORS↗

Environmental effects on the UV upturn in local clusters of galaxies

ABSTRACT We explore the dependence of ultraviolet (UV) upturn colours in early-type cluster galaxies on the properties of their parent clusters (such as velocity dispersion and X-ray luminosity) and on the positions and kinematics of galaxies within them. We use a sample of 24 nearby clusters with highly complete spectroscopy and optical/infrared data to select a suitable sample of red-sequence galaxies, whose far-ultraviolet and NUV magnitudes we measure from archival GALEX data. Our results show that the UV upturn colour has no dependence on cluster properties and has the same range in all clusters. There is also no dependence on the projected position within clusters or on line-of-sight velocity. Therefore, our conclusion is that the UV upturn phenomenon is an intrinsic feature of cluster early-type galaxies, irrespective of their cluster environment.

Ali, Sadman S.↗

THE OPTICALLY UNBIASED GAMMA-RAY BURST HOST (TOUGH) SURVEY. I. SURVEY DESIGN AND CATALOGS

Long-duration gamma-ray bursts (GRBs) are powerful tracers of star-forming galaxies. We have defined a homogeneous subsample of 69 Swift GRB-selected galaxies spanning a very wide redshift range. Special attention has been devoted to making the sample optically unbiased through simple and well-defined selection criteria based on the high-energy properties of the bursts and their positions on the sky. Thanks to our extensive follow-up observations, this sample has now achieved a comparatively high degree of redshift completeness, and thus provides a legacy sample, useful for statistical studies of GRBs and their host galaxies. In this paper, we present the survey design and summarize the results of our observing program conducted at the ESO Very Large Telescope (VLT) aimed at obtaining the most basic properties of galaxies in this sample, including a catalog of R and K{sub s} magnitudes and redshifts. We detect the host galaxies for 80% of the GRBs in the sample, although only 42% have K{sub s} -band detections, which confirms that GRB-selected host galaxies are generally blue. The sample is not uniformly blue, however, with two extremely red objects detected. Moreover, galaxies hosting GRBs with no optical/NIR afterglows, whose identification therefore relies on X-ray localizations, are significantly brighter and redder than those with an optical/NIR afterglow. This supports a scenario where GRBs occurring in more massive and dusty galaxies frequently suffer high optical obscuration. Our spectroscopic campaign has resulted in 77% now having redshift measurements, with a median redshift of 2.14 {+-} 0.18. TOUGH alone includes 17 detected z > 2 Swift GRB host galaxies suitable for individual and statistical studies-a substantial increase over previous samples. Seven hosts have detections of the Ly{alpha} emission line and we can exclude an early indication that Ly{alpha} emission is ubiquitous among GRB hosts, but confirm that Ly{alpha} is stronger in GRB-selected galaxies than in flux-limited samples of Lyman break galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THE RADIAL STELLAR CONTENT OF EARLY-TYPE GALAXIES AS A FUNCTION OF MASS AND ENVIRONMENT

Using optical-optical and optical-NIR colors, we analyze the radial dependence of age and metallicity inside massive (M{sub *} {approx}> 10{sup 10.5} M{sub sun}), low-redshift (z < 0.1), early-type galaxies (ETGs), residing in both high-density group regions and the field. On average, internal color gradients of ETGs are mainly driven by metallicity, consistent with previous studies. However, we find that group galaxies feature positive age gradients, {nabla} {sub t}, i.e., a younger stellar population in the galaxy center, and steeper metallicity gradients, compared to the field sample, whose {nabla} {sub t} ranges from negative in lower mass galaxies to positive gradients at higher mass. These dependencies yield new constraints on models of galaxy formation and evolution. We speculate that age and metallicity gradients of group ETGs result from (either gas-rich or minor-dry) mergers and/or cold-gas accretion, while field ETGs exhibit the characteristic flatter gradients expected from younger, more metal-rich stars formed inside-out by later gas cooling.

79 ASTRONOMY AND ASTROPHYSICS↗

Continuous Flow Liquid Microjunction Surface Sampling Probe Connected On-line with HPLC/MS for Spatially Resolved Analysis of Small Molecules and Proteins

RATIONALE: A continuous flow liquid microjunction surface sampling probe extracts soluble material from surfaces for direct ionization and detection by MS. Demonstrated here is the on-line coupling of such a probe with HPLC/MS enabling extraction, separation and detection of small molecules and proteins from surfaces in a spatially resolved (~0.5 mm diameter spots) manner. Methods: A continuous flow liquid microjunction surface sampling probe was connected to a 6-port, 2-position valve for extract collection and injection to an HPLC column. A QTRAP 5500 hybrid triple quadrupole linear ion trap equipped with a Turbo V ion source operated in positive ESI mode was used for all experiments. System operation was tested with extraction, separation and detection of propranolol and associated metabolites from drug dosed tissues and proteins from dried sheep blood spots on paper. Results: Confirmed in the tissue were the parent drug and two different hydroxypropranolol glucuronides. The mass spectrometric response for these compounds from different locations in the liver showed an increase with increasing extraction time (5, 20 and 40 s extractions). For on-line separation and detection/identification of extracted proteins from dried sheep blood spots, two major protein peaks dominated the chromatogram and could be correlated with the expected masses for the hemoglobin and chains. Conclusions: Spatially resolved sampling, separation, and detection of small molecules and proteins from surfaces can be accomplished using a continuous flow liquid microjunction surface sampling probe coupled on-line with HPLC/MS detection.

dried blood spots↗

Sampling problems

Precipitation estimates from satellites are subject to a number of uncertainties involving design characteristics, satellite positioning, natural variability of precipitation, and the noncontinuous acquisition of data. The sources and sizes of these uncertainties are in need of proper evaluation and estimation. The present sampling and estima-theory seems to be adequate for some measurement problems (e.g., determining precipitation at a point), while others require further theoretical work (e.g., determining the time history of precipitation over large areas).

Flueck, J. A.↗

The CN–CH Positive Correlation in the Globular Cluster NGC 5286

We performed low-resolution spectroscopy of the red giant stars in the Galactic globular cluster (GC) NGC 5286, which is known to show intrinsic heavy element abundance variations. We found that the observed stars in this GC are clearly divided into three subpopulations by CN index (CN-weak, CN-intermediate, and CN-strong). The CN-strong stars are also enhanced in the calcium HK′ (7.4 σ ) and CH (5.1 σ ) indices, while the CN-intermediate stars show no significant difference in the strength of the HK′ index from the CN-weak stars. From the comparison with high-resolution spectroscopic data, we found that the CN- and HK′-strong stars are also enhanced in the abundances of Fe and s -process elements. It appears, therefore, that these stars are later-generation stars affected by some supernova enrichment in addition to the asymptotic giant branch ejecta. In addition, unlike normal GCs, sample stars in NGC 5286 show the CN–CH positive correlation, strengthening our previous suggestion that this positive correlation is only discovered in GCs with heavy element abundance variations, such as M22 and NGC 6273.

79 ASTRONOMY AND ASTROPHYSICS↗

Lunar surface dynamics: Some general conclusions and new results from Apollo 16 and 17

Exposure ages of Apollo 17 rocks as measured by tracks and the Kr-Kr rare gas method are reported. Concordant ages of 22 - or + 1 million year (my) are obtained for the station 6 boulder sample 76315. This value is interpreted as the time when the station 6 boulder was emplaced in its present position. Reasonable agreement is also obtained by the two methods for another station 6 boulder, sample 76015. Discordant ages (respectively 5 and 28 my by the track and rare gas methods) are obtained for the station 7 boulder sample, 77135, indicating that the boulder was emplaced at least 5 my ago. The 72 my exposure age of 75035, in general agreement with previous measurements of approximately 85 my for another Camelot boulder, may well date the formation of Camelot. Rock 76015 was split and one surface exposed to the sky through a very small solid angle.

Crozaz, G.↗

Distributed Spatiotemporal Motion Planning for Spacecraft Swarms in Cluttered Environments

This paper focuses on trajectory planning for spacecraft swarms in cluttered environments, like debris fields or the asteroid belt. Our objective is to reconfigure the spacecraft swarm to a desired formation in a distributed manner while minimizing fuel and avoiding collisions among themselves and with the obstacles. In our prior work we proposed a novel distributed guidance algorithm for spacecraft swarms in static environments.1 In this paper, we present the Multi-Agent Moving-Obstacles Spherical Expansion and Sequential Convex Programming (MAMO SE–SCP) algorithm that extends our prior work to include spatiotemporal constraints such as time-varying, moving obstacles and desired time-varying terminal positions. In the MAMO SE–SCP algorithm, each agent uses a spherical-expansion-based sampling algorithm to cooperatively explore the time-varying environment, a distributed assignment algorithm to agree on the terminal position for each agent, and a sequential-convex-programming-based optimization step to compute the locally-optimal trajectories from the current location to the assigned time-varying terminal position while avoiding collision with other agent and the moving obstacles. Simulations results demonstrate that the proposed distributed algorithm can be used by a spacecraft swarm to achieve a time-varying, desired formation around an object of interest in a dynamic environment with many moving and tumbling obstacles.

Hadaegh, Fred Y.↗

4D-STEM of Beam-Sensitive Materials

We report that a scanning electron nanobeam diffraction, or 4D-STEM (four-dimensional scanning transmission electron microscopy), is a flexible and powerful approach to elucidate structure from "soft" materials that are challenging to image in the transmission electron microscope because their structure is easily damaged by the electron beam. In a 4D-STEM experiment, a converged electron beam is scanned across the sample, and a pixelated camera records a diffraction pattern at each scan position. This four-dimensional data set can be mined for various analyses, producing maps of local crystal orientation, structural distortions, crystallinity, or different structural classes. Holding the sample at cryogenic temperatures minimizes diffusion of radicals and the resulting damage and disorder caused by the electron beam. The total fluence of incident electrons can easily be controlled during 4D-STEM experiments by careful use of the beam blanker, steering of the localized electron dose, and by minimizing the fluence in the convergent beam thus minimizing beam damage. This technique can be applied to both organic and inorganic materials that are known to be beam-sensitive; they can be highly crystalline, semicrystalline, mixed phase, or amorphous. One common example is the case for many organic materials that have a π-π stacking of polymer chains or rings on the order of 3.4-4.2 Å separation. If these chains or rings are aligned in some regions, they will produce distinct diffraction spots (as would other crystalline spacings in this range), though they may be weak or diffuse for disordered or weakly scattering materials. We can reconstruct the orientation of the π-π stacking, the degree of π-π stacking in the sample, and the domain size of the aligned regions. This Account summarizes illumination conditions and experimental parameters for 4D-STEM experiments with the goal of producing images of structural features for materials that are beam-sensitive. We will discuss experimental parameters including sample cooling, probe size and shape, fluence, and cameras. 4D-STEM has been applied to a variety of materials, not only as an advanced technique for model systems, but as a technique for the beginning microscopist to answer materials science questions. It is noteworthy that the experimental data acquisition does not require an aberration-corrected TEM but can be produced on a variety of instruments with the right attention to experimental parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of Lubricant Additive Interactions on Gasoline Particulate Filters

To understand how the composition of novel lubricant additives and their ash interact with gasoline particulate filters (GPFs), an accelerated aging protocol was conducted using three lubricant additive formulations and two GPF types. The additive packages (adpaks) consisted of Ca+Mg detergent in a 3:1 or 0:1 ratio and an anti-wear component—either zinc dialkyl dithiophosphate (ZDDP) or a novel phosphonium-phosphinate ionic liquid (IL) substitute. The particulate sampling captured amount/compositions of particulate matter (PM) generated, total particulate number, and size distribution. Five ash loadings were completed. GPF position and adpak composition affected the backpressure, ash composition, ash morphology, and captured mass. The particulate sampling indicated that the ash component consisted primarily of particles less than 50 nm in size and that the Mg-only adpak resulted in more particulate of 50–400 nm in size. Postmortem materials characterization indicated GPFs in the underfloor position had deeper penetration of ash into the walls compared to the close-coupled position. Additionally, the Mg-only adpak had a higher filter collection efficiency (>90%) and the ash particles consisted of a higher concentration of dense ash material. In contrast, four of the 3:1 Ca:Mg lubricant adpaks resulted in a collection efficiency of only 40–50%. Although the collection efficiency was higher with the Mg-only adpak, the ash layer in the GPF was not thicker, nor was the penetration into the wall more significant, and surprisingly the full useful life (FUL) backpressure was lower than with Ca:Mg adpaks. The higher density of the Mg-derived ash was the only detectable difference. A possible explanation of this observation is that Mg ash has a lower melting point and is more susceptible to densification during combustion or GPF regeneration. The substitution of IL in place of the ZDDP did not lead to any notable changes in collection efficiency or location of the ash.

42 ENGINEERING↗

High-precision measurement of magnetic penetration depth in superconducting films

We report that the magnetic penetration depth (λ) in thin superconducting films is usually measured by the mutual inductance technique. The accuracy of this method has been limited by uncertainties in the geometry of the solenoids and in the film position and thickness, by parasitic coupling between the coils, etc. Here, we present several improvements in the apparatus and the method. To ensure the precise thickness of the superconducting layer, we engineer the films at atomic level using atomic-layer-by-layer molecular beam epitaxy. In this way, we also eliminate secondary-phase precipitates, grain boundaries, and pinholes that are common with other deposition methods and that artificially increase the field transmission and thus the apparent λ. For better reproducibility, the thermal stability of our closed-cycle cryocooler used to control the temperature of the mutual inductance measurement has been significantly improved by inserting a custom-built thermal conductivity damper. Next, to minimize the uncertainties in the geometry, we fused a pair of small yet precisely wound coils into a single sapphire block machined to a high precision. Lastly, the sample is spring-loaded to exactly the same position with respect to the solenoids. Altogether, we can measure the absolute value of λ with the accuracy better than ±1%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diversity in the Visible-NIR Absorption Band Characteristics of Lunar and Asteroidal Plagioclase

Studying the visible and near-infrared (VNIR) spectral properties of plagioclase has been challenging because of the difficulty in obtaining good plagioclase separates from pristine planetary materials such as meteorites and returned lunar samples. After an early study indicated that the 1.25 m band position of plagioclase spectrum might be correlated with the molar percentage of anorthite (An#) [1], there have been few studies which dealt with the band center behavior. In this study, the VNIR absorption band parameters of plagioclase samples have been derived using the modified Gaussian model (MGM) [2] following a pioneering study by [3].

Hiroi, T.↗