Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 06: Investigation of an absorbed dose to water formalism for a miniature low-energy x-ray source

Purpose: We present a formalism for calculating the absorbed dose to water from a miniature x-ray source (The INTRABEAM system, Carl Zeiss), using a parallel-plate ionization chamber calibrated in terms of air-kerma. Monte Carlo calculations were performed to derive a chamber conversion factor (C{sub Q}) from reference air-kerma to dose to water for the INTRABEAM. C{sub Q} was investigated as a function of depth in water, and compared with the manufacturer’s reported value. The effect of chamber air cavity dimension tolerance was also investigated. Methods: Air-kerma (A{sub k}) from a reference beam was calculated using the EGSnrc user code cavity. Using egs-chamber, a model of a PTW 34013 parallel-plate ionization chamber was created according to manufacturer specifications. The dose to the chamber air cavity (D{sub gas}) was simulated both in-air (with reference beam) and in-water (with INTRABEAM source). Dose to a small water voxel (D{sub w}) was also calculated. C{sub Q} was derived from these quantities. Results: C{sub Q} was found to vary by up to 15% (1.30 vs 1.11) between chamber dimension extremes. The agreement between chamber C{sub Q} was found to improve with increasing depth in water. However, in all cases investigated, C{sub Q} was larger than the manufacturer reported value of 1.054. Conclusions: Our results show that cavity dimension tolerance has a significant effect on C{sub Q}, with differences as large as 15%. In all cases considered, C{sub Q} was found to be larger than the reported value of 1.054. This suggests that the recommended calculation underestimates the dose to water.

60 APPLIED LIFE SCIENCES↗

Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry

The purpose of this study is to calculate correction factors for plastic water (PW) and plastic water diagnostic-therapy (PWDT) phantoms in clinical photon and electron beam dosimetry using the EGSnrc Monte Carlo code system. A water-to-plastic ionization conversion factor k{sub pl} for PW and PWDT was computed for several commonly used Farmer-type ionization chambers with different wall materials in the range of 4-18 MV photon beams. For electron beams, a depth-scaling factor c{sub pl} and a chamber-dependent fluence correction factor h{sub pl} for both phantoms were also calculated in combination with NACP-02 and Roos plane-parallel ionization chambers in the range of 4-18 MeV. The h{sub pl} values for the plane-parallel chambers were evaluated from the electron fluence correction factor {phi}{sub pl}{sup w} and wall correction factors P{sub wall,w} and P{sub wall,pl} for a combination of water or plastic materials. The calculated k{sub pl} and h{sub pl} values were verified by comparison with the measured values. A set of k{sub pl} values computed for the Farmer-type chambers was equal to unity within 0.5% for PW and PWDT in photon beams. The k{sub pl} values also agreed within their combined uncertainty with the measured data. For electron beams, the c{sub pl} values computed for PW and PWDT were from 0.998 to 1.000 and from 0.992 to 0.997, respectively, in the range of 4-18 MeV. The {phi}{sub pl}{sup w} values for PW and PWDT were from 0.998 to 1.001 and from 1.004 to 1.001, respectively, at a reference depth in the range of 4-18 MeV. The difference in P{sub wall} between water and plastic materials for the plane-parallel chambers was 0.8% at a maximum. Finally, h{sub pl} values evaluated for plastic materials were equal to unity within 0.6% for NACP-02 and Roos chambers. The h{sub pl} values also agreed within their combined uncertainty with the measured data. The absorbed dose to water from ionization chamber measurements in PW and PWDT plastic materials corresponds to that in water within 1%. Both phantoms can thus be used as a substitute for water for photon and electron dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

A global reference atmospheric model for surface to orbital altitudes

An empirical atmospheric model has been developed which generates values for pressure, density, temperature and winds from surface levels to orbital altitudes. The output parameters consist of components for: (1) latitude, longitude, and altitude dependent monthly means; (2) quasi-biennial oscillations; and (3) random perturbations to partially simulate the variability due to synoptic, diurnal, planetary wave and gravity wave variations. The monthly mean models consist of: NASA's four dimensional worldwide model for height, latitude, and longitude dependent monthly means from the surface to 25 km; and a newly developed latitude-longitude dependent model which is an extension of the Groves latitude dependent model for the region between 25 and 90 km. The Jacchia 1970 model is used above 90 km and is faired with the modified Groves values between 90 and 115 km. Quasi-biennial and random variation perturbations are computed from parameters determined from various empirical studies, and are added to the monthly mean values.

Justus, C. G.↗

Advanced Life Support Research and Technology Development Metric

The Metric is one of several measures employed by the NASA to assess the Agency s progress as mandated by the United States Congress and the Office of Management and Budget. Because any measure must have a reference point, whether explicitly defined or implied, the Metric is a comparison between a selected ALS Project life support system and an equivalently detailed life support system using technology from the Environmental Control and Life Support System (ECLSS) for the International Space Station (ISS). This document provides the official calculation of the Advanced Life Support (ALS) Research and Technology Development Metric (the Metric) for Fiscal Year 2004. The values are primarily based on Systems Integration, Modeling, and Analysis (SIMA) Element approved software tools or reviewed and approved reference documents. For Fiscal Year 2004, the Advanced Life Support Research and Technology Development Metric value is 2.03 for an Orbiting Research Facility and 1.62 for an Independent Exploration Mission.

Hanford, A. J.↗

Aquarius Instrument Science Calibration During the Risk Reduction Phase

This final report presents the results of work performed under NASA Grant NAG512726 during the period 15 January 2003 through 30 June 2004. An analysis was performed of a possible vicarious calibration method for use by Aquarius to monitor and stabilize the absolute and relative calibration of its microwave radiometer. Stationary statistical properties of the brightness temperature (T(sub B)) measured by a low Earth orbiting radiometer operating at 1.4135 GHz are considered as a means of validating its absolute calibration. The global minimum, maximum, and average T(sub B) are considered, together with a vicarious cold reference method that detects the presence of a sharp lower bound on naturally occurring values for T(sub B). Of particular interest is the reliability with which these statistics can be extracted from a realistic distribution of T(sub B) measurements that would be observed by a typical sensor. Simulations of measurements are performed that include the effects of instrument noise and variable environmental factors such as the global water vapor and ocean surface temperature, salinity and wind distributions. Global minima can vary widely due to instrument noise and are not a reliable calibration reference. Global maxima are strongly influenced by several environmental factors as well as instrument noise and are even less stationary. Global averages are largely insensitive to instrument noise and, in most cases, to environmental conditions as well. The global average T(sub B) varies at only the 0.1 K RMS level except in cases of anomalously high winds, when it can increase considerably more. The vicarious cold reference is similarly insensitive to instrument effects and most environmental factors. It is not significantly affected by high wind conditions. The stability of the vicarious reference is, however, found to be somewhat sensitive (at the several tenths of Kelvins level) to variations in the background cold space brightness, T(sub c). The global average is much less sensitive to this parameter and so using two approaches together can be mutually beneficial.

Ruf, Christopher S.↗

The Many Dimensions of Program Management

For the purposes of this paper, program refers to a collection of activities or projects which must be performed according to a plan or schedule. The Space Exploration Initiative within the National Aeronautics and Space Administration (NASA) is an example. Dimensionality refers to both the various perspectives of a program and to the components within that perspective. It is, thus, appropriate to think of dimensions of dimensionality. For example, one dimension or perspective of a program is the projects which perform the program. Within the project dimension, the individual projects are the components of that dimensionality. The number of projects defines the spatial dimensionality of the project dimension. Thus, each perspective or dimension has a dimensionality of its own. The structure and associated values of all the various perspectives of a program define the program. A project refers to the collection of activities required to conceive, sell, design, develop, evaluate, produce, operate, support, evolve, and retire a given system. A project thus effects the life cycle of given system. A project is, thus, the system to conceive, sell, design, develop, evaluate, produce, operate, support, evolve, and retire a system. A program, thus, effects the life cycle of the collection of projects required to effect the collection of systems required to implement the program.

Dean, Edwin B.↗

An Algal Nutrient‐Replete, Optimized Medium for Fast Growth and High Triacylglycerol Accumulation

Microalgae are promising sources to sustainably meet the global needs for energy and products. Algae grow under different trophic conditions, where nutritional status regulates biosynthetic pathways, energy production, and growth. The green alga Chromochloris zofingiensis has strong economic potential because it co-produces biofuel precursors and the high-value antioxidant astaxanthin while accumulating biomass when grown mixotrophically. As an emerging reference alga for photosynthesis, metabolism, and bioproduction, C. zofingiensis needs a defined, optimized medium to standardize experiments during fast growth for batch cultivation. Because the interplay of glucose treatment (+Glc) and mineral deficiency influences photosynthesis, growth, and the production of lipids and astaxanthin, we designed a replete nutrient medium tailored to the C. zofingiensis cellular ionome. We combined inductively coupled plasma mass spectrometry (ICP-MS) and +Glc growth curves to determine a medium that is nutrient replete for at least 5 days of +Glc logarithmic growth. We found that there are high nutritional needs for phosphorus and sulfur during mixotrophy. Iron was the only element measured for which the cellular concentration correlated with exogenous concentration and was iteratively adjusted until the cellular ionome was consistent through the logarithmic growth phase. This Chromochloris-Optimized Ratio of Elements (CORE) medium supports fast growth and high biomass and lipid accumulation without causing excess nutrient toxicity. This defined, nutrient-replete standard is important for future C. zofingiensis investigations and can be adapted for other species to support high biomass for batch cultivation. The method used to develop CORE medium shows how ionomics informs replicable media design and may be applied in industrial settings to inform cost-effective biofuel production.

Jeffers, Tim L. [University of California, Berkele↗

Post-occupancy evaluation of indoor environmental quality in ten nonresidential buildings in Chongqing, China

Indoor environmental quality (IEQ) is an essential element of sustainable building performance. To advance knowledge of indoor environmental quality in Chinese nonresidential buildings, this study conducted post-occupancy evaluation (POE) in varied use areas within schools, hospitals, offices, hotels and shopping malls through environmental measurements and occupant surveys in 10 buildings over four seasons in Chongqing, China. Measured thermal conditions were more frequently within comfort standards in winter than in summer according to the predicted mean vote – predicted percentage dissatisfied model; but the model did not reliably predict thermal satisfaction. There was insufficient illuminance in 28% of studied areas and high illuminance in shopping malls led to complaints about glare. Sound pressure exceeded the Chinese guideline in all buildings with shopping malls having significantly higher levels than other buildings. CO 2 was generally below the Chinese national guideline of 1000 ppm; the two percent of measurements that exceeded the guideline occurred in classrooms, hospital wards and underground supermarkets. Formaldehyde did not exceed the limit level of 0.1 mg/m3 in any space. Most of the buildings did not provide effective protection from outdoor fine particulate matter (PM2.5), and infiltration from outdoors was the main factor for exceeding health-based guidelines indoors. Shopping malls had lower IEQ satisfaction than offices, schools and hospitals. Sound was the factor with the lowest satisfaction level among the four principal environmental factors. Overall, this study demonstrates value of POE on identifying deficiencies in indoor environment and provides a reference for assessment of IEQ in nonresidential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Performance and Long Term Stability of the D0 Run II Forward Muon Scintillation Counters

The performance of the D0 experiment forward muon scintillation counters system during Run II of the Tevatron from 2001 to 2011 is described. The system consists of 4214 scintillation counters in six layers. The long term stability of the counters amplitude response determined using LED calibration system and muons produced in proton-antiproton collisions is presented. The average signal amplitude for counters of all layers has gradually decreased over ten years by 11%. The reference timing, determined using LED calibration, was stable within 0.26 ns. Average value of muon timing peak position was used for periodic D0 clock signal adjustments to compensate seasonal drift caused by temperature variations. Counters occupancy for different triggers in physics data collection runs and for minimum bias triggers are presented. The single muon yields versus time and the luminosity dependence of yields were stable for the forward muon system within 1% over 10 years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On spectral synthesis on element-wise compact Abelian groups

Let G be an arbitrary locally compact Abelian group and let C(G) be the space of all continuous complex-valued functions on G. A closed linear subspace H⊆C(G) is referred to as an invariant subspace if it is invariant with respect to the shifts τ{sub y}:f(x)↦f(xy), y∈G. By definition, an invariant subspace H⊆C(G) admits strict spectral synthesis if H coincides with the closure in C(G) of the linear span of all characters of G belonging to H. We say that strict spectral synthesis holds in the space C(G) on G if every invariant subspace H⊆C(G) admits strict spectral synthesis. An element x of a topological group G is said to be compact if x is contained in some compact subgroup of G. A group G is said to be element-wise compact if all elements of G are compact. The main result of the paper is the proof of the fact that strict spectral synthesis holds in C(G) for a locally compact Abelian group G if and only if G is element-wise compact. Bibliography: 14 titles.

97 MATHEMATICS AND COMPUTING↗

Multiscale analysis of the CMB temperature derivatives

We study the Planck CMB temperature at different scales through its derivatives up to second order, which allows one to characterize the local shape and isotropy of the field. The problem of having an incomplete sky in the calculation and statistical characterization of the derivatives is addressed in the paper. The analysis confirms the existence of a low variance in the CMB at large scales, which is also noticeable in the derivatives. Moreover, deviations from the standard model in the gradient, curvature and the eccentricity tensor are studied in terms of extreme values on the data. As it is expected, the Cold Spot is detected as one of the most prominent peaks in terms of curvature, but additionally, when the information of the temperature and its Laplacian are combined, another feature with similar probability at the scale of 10{sup o} is also observed. However, the p -value of these two deviations increase above the 6% when they are referred to the variance calculated from the theoretical fiducial model, indicating that these deviations can be associated to the low variance anomaly. Finally, an estimator of the directional anisotropy for spinorial quantities is introduced, which is applied to the spinors derived from the field derivatives. An anisotropic direction whose probability is <1% is detected in the eccentricity tensor.

79 ASTRONOMY AND ASTROPHYSICS↗

A viscoelastic model for seismic attenuation using fractal mechanical networks

SUMMARY Seismic attenuation (quantified by the quality factor Q) has a significant impact on the seismic waveforms, especially in the fluid-saturated rocks. This dissipative process can be phenomenologically represented by viscoelastic models. Previous seismological studies show that the Q value of Earth media exhibits a nearly frequency-independent behaviour (often referred to as constant-Q in literature) in the seismic frequency range. Such attenuation can be described by the mathematical Kjartansson constant-Q model, which lacks of a physical representation in the viscoelastic sense. Inspired by the fractal nature of the pore fluid distribution in patchy-saturated rocks, here we propose two fractal mechanical network (FMN) models, that is, a fractal tree model and a quasi-fractal ladder model, to phenomenologically represent the frequency-independent Q behaviour. As with the classic viscoelastic models, the FMN models are composed of mechanical elements (spring and dashpots) arranged in different hierarchical patterns. A particular parametrization of each model can produce the same complex modulus as in the Kjartansson model, which leads to the constant-Q. Applying the theory to several typical rock samples, we find that the seismic attenuation signature of these rocks can be accurately represented by either one of the FMN models. Besides, we demonstrate that the ladder model in particular exhibits the realistic multiscale fractal structure of the saturated rocks. Therefore, the FMN models as a proxy could provide a new way to estimate the microscopic rock structure property from macroscopic seismic attenuation observation.

Geochemistry & Geophysics↗

Stabilization of Solitons Generated by a Supersonic Flow of Bose-Einstein Condensate Past an Obstacle

The stability of dark solitons generated by supersonic flow of a Bose-Einstein condensate past an obstacle is investigated. It is shown that in the reference frame attached to the obstacle a transition occurs at some critical value of the flow velocity from absolute instability of dark solitons to their convective instability. This leads to the decay of disturbances of solitons at a fixed distance from the obstacle and the formation of effectively stable dark solitons. This phenomenon explains the surprising stability of the flow picture that has been observed in numerical simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Cooperative Game Theory-based Approach to Under-frequency Load Shedding Control

This paper proposes a cooperative game theory-based under-frequency load shedding (UFLS) approach for frequency stability and control in power systems. UFLS is a crucial factor for frequency stability and control especially in power grids with high penetration of renewable energy sources and restructured power systems. Conventional UFLS methods, most of which are off-line, usually shed fixed amounts of predetermined loads based on a predetermined schedule which can lead to over or under curtailment of load. This paper presents a co-operative game theory-based two-stage strategy to effectively and precisely determine locations and amounts of loads to be shed for UFLS control. In the first stage, the total amount of loads to be shed, also referred to as deficit in generation or the disturbance power, is computed using the initial rate of change of frequency (ROCOF) referred to the equivalent inertial center. In the second stage, the Shapley value, one of the solution concepts of cooperative game theory, is used to determine load shedding amounts and locations. The proposed method is implemented on the reduced 9-bus 3-machine Western Electricity Coordinating Council (WECC) system and simulated on Real-time Digital Simulators (RTDS). The results show that the proposed UFLS approach can effectively return the system to normal state after disturbances.

42 ENGINEERING↗

Replacement correction factors for cylindrical ion chambers in electron beams

Purpose: In the TG-21 dosimetry protocol, for cylindrical chambers in electron beams the replacement correction factor P{sub repl} (or the product p{sub dis}p{sub cav} in the IAEA's notation), was conceptually separated into two components: the gradient correction (P{sub gr}) accounting for the effective point of measurement and the fluence correction (P{sub fl}) dealing with the change in the electron fluence spectrum. At the depth of maximum dose (d{sub max}), P{sub gr} is taken as 1. There are experimental data available at d{sub max} for the values of P{sub fl} (or P{sub repl}). In the TG-51 dosimetry protocol, the calibration is at the reference depth d{sub ref}=0.6R{sub 50}-0.1 (cm) where P{sub gr} is required for cylindrical chambers and P{sub fl} is unknown and so the measured values at d{sub max} are used with the corresponding mean electron energy at d{sub ref}. Monte Carlo simulations are employed in this study to investigate the replacement correction factors for cylindrical chambers in electron beams. Methods: Using previously established Monte Carlo calculation methods, the values of P{sub repl} and P{sub fl} are calculated with high statistical precision (<0.1%) for cylindrical cavities of a variety of diameters and lengths in a water phantom irradiated by various electron beams. The values of P{sub gr} as defined in the TG-51 dosimetry protocol are also calculated. Results: The calculated values of the fluence correction factors P{sub fl} are in good agreement with the measured values when the wall correction factors are taken into account for the plane-parallel chambers used in the measurements. An empirical formula for P{sub fl} for cylindrical chambers at d{sub ref} in electron beams is derived as a function of the chamber radius and the beam quality specifier R{sub 50}. Conclusions: The mean electron energy at depth is a good beam quality specifier for P{sub fl}. Thus TG-51's adoption of P{sub fl} at d{sub max} with the same mean electron energy for use at d{sub ref} is proven to be accurate. The values of P{sub gr} for a Farmer-type chamber as defined in the TG-51 dosimetry protocol may be wrong by 0.3% for high-energy electron beams and by more than 1% for low-energy electron beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-65: Estimation of Tagging Efficiency in Pseudo-Continuous Arterial Spin Labeling (pCASL) MRI

Purpose: pCASL was recommended as a potent approach for absolute cerebral blood flow (CBF) quantification in clinical practice. However, uncertainties of tagging efficiency in pCASL remain an issue. This study aimed to estimate tagging efficiency by using short quantitative pulsed ASL scan (FAIR-QUIPSSII) and compare resultant CBF values with those calibrated by using 2D Phase Contrast (PC) MRI. Methods: Fourteen normal volunteers participated in this study. All images, including whole brain (WB) pCASL, WB FAIR-QUIPSSII and single-slice 2D PC, were collected on a 3T clinical MRI scanner with a 8-channel head coil. DeltaM map was calculated by averaging the subtraction of tag/control pairs in pCASL and FAIR-QUIPSSII images and used for CBF calculation. Tagging efficiency was then calculated by the ratio of mean gray matter CBF obtained from pCASL and FAIR-QUIPSSII. For comparison, tagging efficiency was also estimated with 2D PC, a previously established method, by contrast WB CBF in pCASL and 2D PC. Feasibility of estimation from a short FAIR-QUIPSSII scan was evaluated by number of averages required for obtaining a stable deltaM value. Setting deltaM calculated by maximum number of averaging (50 pairs) as reference, stable results were defined within ±10% variation. Results: Tagging efficiencies obtained by 2D PC MRI (0.732±0.092) were significantly lower than which obtained by FAIRQUIPPSSII (0.846±0.097) (P<0.05). Feasibility results revealed that four pairs of images in FAIR-QUIPPSSII scan were sufficient to obtain a robust calibration of less than 10% differences from using 50 pairs. Conclusion: This study found that reliable estimation of tagging efficiency could be obtained by a few pairs of FAIR-QUIPSSII images, which suggested that calibration scan in a short duration (within 30s) was feasible. Considering recent reports concerning variability of PC MRI-based calibration, this study proposed an effective alternative for CBF quantification with pCASL.

60 APPLIED LIFE SCIENCES↗

SU-E-T-582: On-Line Dosimetric Verification of Respiratory Gated Volumetric Modulated Arc Therapy Using the Electronic Portal Imaging Device

Purpose: To investigate the clinical utility of on-line verification of respiratory gated VMAT dosimetry during treatment. Methods: Portal dose images were acquired during treatment in integrated mode on a Varian TrueBeam (v. 1.6) linear accelerator for gated lung and liver patients that used flattening filtered beams. The source to imager distance (SID) was set to 160 cm to ensure imager clearance in case the isocenter was off midline. Note that acquisition of integrated images resulted in no extra dose to the patient. Fraction 1 was taken as baseline and all portal dose images were compared to that of the baseline, where the gamma comparison and dose difference were used to measure day-to-day exit dose variation. All images were analyzed in the Portal Dosimetry module of Aria (v. 10). The portal imager on the TrueBeam was calibrated by following the instructions for dosimetry calibration in service mode, where we define 1 calibrated unit (CU) equal to 1 Gy for 10×10 cm field size at 100 cm SID. This reference condition was measured frequently to verify imager calibration. Results: The gamma value (3%, 3 mm, 5% threshold) ranged between 92% and 100% for the lung and liver cases studied. The exit dose can vary by as much as 10% of the maximum dose for an individual fraction. The integrated images combined with the information given by the corresponding on-line soft tissue matched cone-beam computed tomography (CBCT) images were useful in explaining dose variation. For gated lung treatment, dose variation was mainly due to the diaphragm position. For gated liver treatment, the dose variation was due to both diaphragm position and weight loss. Conclusion: Integrated images can be useful in verifying dose delivery consistency during respiratory gated VMAT, although the CBCT information is needed to explain dose differences due to anatomical changes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Synthetic Biology PacBio/JAWS QC Analysis (PBJ) v3.0

This software was designed as a sequence validation tool for the assembly of synthetic constructs. It analyzes FASTQ files against a list of reference sequences, combining the results from eight sequencing libraries to generate a summary, and the files needed to view the results in the Integrative Genomics Viewer (IGV) application for manual verification. This was developed for FASTQ files generated by PacBio sequencing, but could be used on any FASTQ files that do not have paired end reads. It can be used to analyze one - eight libraries at a time, and assumes that each construct sequence in the reference will be in each pool, however, this is not a requirement. This is used to identify which libraries of pooled sequences contains a perfect match, or fixable match to the reference file. This pipeline uses many freely available open source libraries, the value added is that in our application the steps of the pipeline are defined in Workflow Description Language (WDL) and run through the Cromwell workflow engine in Docker containers, for easy distribution and set up, as well as the user friendly html summary that is generated.

Simirenko, Lisa↗